1 minute read

OPERATING INSTRUCTIONS RH 340

Inspection and servicing

Radiators

The radiators are located on the superstructure in the counterweight module.

Weekly checks:

" Check radiator fins for dirt and clean, if required.

Cooling-liquid level

An insufficient cooling-liquid level is displayed on the BCS screen (2, Fig. 3-30:).

Risk of scalding from hot cooling liquid. Open radiator cap cautiously.

" Turn radiator cap (1) back to the first notch.

" When the pressure has been released turn cap into the "open" position and remove.

The cooling-liquid level should reach up to the lower edge of the filler tube. Top up with cooling liquid, if required.

The level indicator (4, Fig. 3-31:) shows the liquid level.

The radiator caps (1, Fig. 3-30:) are accessible from above.