1 minute read

FILLING

Next Article
MACHINE STORAGE

MACHINE STORAGE

RINSING

STEP 1

Close the drain valve once the radiator is completely empty. Close the plug on the engine block. Fill the system with clean water. Install the radiator cap.

STEP 2

Start and run the engine at a speed slightly higher than low idle for ten minutes to bring the engine temperature to approximately 80°C.

STEP 3

Drain the system once more.

STEP 4

Repeat Steps 1 to 3 until the water drained is clear.

STEP 1 STEP 2

BD00M223 Fill the expansion reservoir to the “FULL” mark and install the cap. IMPORTANT: Use the correct coolant solution.

STEP 3

Run the engine at idle speed for about five minutes. Add coolant solution if the level in the expansion reservoir drops. IMPORTANT: Do not fill the expansion reservoir above the “FULL” mark.

CD00E171 Fill with coolant solution via the radiator until overflowing and install the radiator cap.