2 minute read
5Parameters
Valid from serial number T-code C-code/Section
555494AA- 675 5000
Order number Date Version
208587-040 2002-06-04 001
5 Parameters
The following parameters can be changed.
NOTE !
Truck handling.
Modifying specific truck parameters will change the driving characteristics of the truck.
Do not change any parameters without the necesarry know-how.
5.1Parameters
Parameter Min Max Std Description
ACC. DELAY 0 9 6 Determines the acceleration ramp MAX SP BACK 0 9 7 Maximum speed, fork direction, adjustment MAX SP FORW 0 9 7 Maximum speed, steer wheel direction, adjustment INVERSION BRAKING 0 9 9 Determines the deceleration ramp when the direction switch is inverted during driving
RELEASE BRAKING
0 9 5 Determines the deceleration ramp when the travel request is released DECELER DELAY 0 9 5 Determines the deceleration ramp according to the speed controller position CHECK UP DONE OFF Resets the hour meter of the service counter.
CHECK UP TYPE 0 3 0 Allows setting of the service counter CHECK UP HOURS 0 9 2 Indicates the time when the next service visit is required
ACC.DELAY
The higher the parameter value, the longer it takes for the truck to reach the maximum speed.
MAX SPEED BACK
The maximum speed in the fork direction can be adjusted as a percentage of maximum speed. 0 = 100 % 9 = 62 %
C-code/Section T-code Valid from serial number
5000 675 555494AA-
Version Date Order number
001 2002-06-04 208587-040
MAX SPEED FORW
The maximum speed in the drive wheel direction can be adjusted as a percentage of maximum speed. 0 = 100 % 9 = 62 %
INVERSION BRAKING
Determines the retardation when the accelerator control is shifted to the opposite direction while driving. 0 = Softer retardation 9 = Harder retardation
RELEASE BRAKING
Determines motor braking efficiency when the accelerator control is released to the neutral position. 0 = Softer retardation 9 = Harder retardation
DECELER DELAY
Determines retardation in relation to the position of the accelerator control. Changing this parameter results in limited change.
CHECK UP DONE
ON/OFF parameter. Resets the hour meter of the service counter. Automatically set to OFF when the hour meter is reset.
CHECK UP TYPE
It is possible to programme the Next Service function: 0 = No service warning 1 = Service warning after the set number of hours in the parameter CHECK UP HOURS. 2 = Service warning after the set number of hours in the parameter CHECK UP HOURS. Speed reduction when the time has been exceeded by 10 hours. 3 = Service warning after the set number of hours in the parameter CHECK UP HOURS. Speed reduction when the time has been exceeded by 10 hours. Blocking of all functions when the time has been exceeded by 20 hours. The service warning results in an alarm on the transistor panel: 3 + 8 CHECK UP NEEDED Quick blinking of the BDI battery indicator.
CHECK UP HOURS
Determines "After number of hours" when the service warning is displayed. The parameter can be set from 0 to 9. Each step increments the time by 50 hours. 0 = 200 hours 9 = 650 hours.