7.1General notes
Please observe strictly the safety regulations in the corresponding section of these operating and maintenance instructions.
Malfunctions are frequently caused by incorrect operation of the machine or insufficient maintenance. Whenever a fault occurs you should therefore thoroughly read these instruction on correct operation and maintenance.
If you cannot locate the cause of a fault or rectify it yourself by following the trouble shooting chart, you should contact our customer service department.
7.2Starting with jump wires
Note i
Choose this type of starting if the starter battery is exhausted and the machine cannot be started manually with the safety crank handle.
Caution !
A wrong connection will cause severe damage in the electric system. The auxiliary battery must have the same voltage as the starter battery.
l Loosen the hood fastening screws (1) on both sides and remove the hood fastening screws (2) on both sides (Fig. 84).
l Fold the hood back to open.
l Remove the battery holder and take off the vibration damping mat.
l Check insulation mats, brackets and screw connections, replace if necessary.
l Join the plus poles on external battery and starter battery with the jump wire (Fig. 85).
l Use the second jump start cable to connect the negative poles on external battery and starter battery.
l Perform the starting process as described before.
l When the engine is running remove the jump start cable from the two negative poles first and from the positive poles after.
Note i
This work sequence is necessary to avoid short circuit caused by contact between positive and negative cables.
l Close the hood again and ´fasten it with bolts.