Zone of use....................................................................................................................................................................A1
Inlet and exhaust
Zone of use
The "EGR" system is active when all the following conditions are met: – Engine hot. – Engine speed > 1400rpm. – charge > 40%.
y 1
40 % A B
(~ 10 %)
60ahsm22
Description
1 Progressive opening zone. A "EGR" system inactive. B "EGR" active.
In zone(B), the recycling rate is about10%. The recycling rate is monitored using 3pieces of information: compressed fresh air temperature, recycled exhaust gas temperature, and mixed air temperature. Variation in the quantity of gas recycled is controlled by turbocharger control. In case of effectiveness problem with the recycling system, an error code is announced.
1 500 x
Fig. 34
X Engine speed in rpm. Y Torque in%.