2014 Sisgeo Catalogue - Geotechnical instruments and structural health monitoring

Page 15

level Pressure Transducers

Water Level Logger (WLL)

seepage measurements weir Monitoring

The model P252R is a level transducer equipped with a relative vented piezoresistive pressure sensor which provides automatic compensation of the barometric changes. This transducer provides ground water table monitoring in standpipe and Casagrande piezometers.

Water Level Logger (WLL) is an integrated system designed for automatic monitoring of water level and temperature inside wells, standpipes and Casagrande piezometers. WLL with its integrated datalogger must be programmed and lowered in the open pipe below the water level. It has to be periodically retrieved for downloading data.

V-notch weirs are typically installed in open channels such as streams to determine discharge (flowrate). The basic principle is that the discharge is directly related to the water depth above the bottom of the “V”. Leakage measuremenst is one of the most important indicators of the overall performance of dikes and dams.

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

V-NOTCH WEIRS

Standard ranges

100, 200, 500 kPa, 1.0 MPa

Water level range*

4, 9, 30, 76 m of water

The purpose of the weir is to transform the instantaneous flow

Signal output

4-20 mA (current loop)

Temp. measurem. range

-20°C +50°C

values into the pressure/level by means of specific measuring

Sensitivity

0.01% FS

Accuracy:

Total accuracy (*)

< 0.25% FS

- water level**

±0.05% F.S.

Power supply

12 - 24 Vdc

- temperature

±0.5°C

Overload

30%

Memory type

Non-volatile

Thermal zero shift

0.00025 % /°C

Memory capacity

64k-byte

Temp. Operating range

-10°C +55°C

Filter unit

syntherized stainless steel

Body material

stainless steel

Diameter / length

28 mm / 200 mm

Communication port

Optical USB interface

Cable

0WE203KEO00

Diameter / length

24.6 mm / 150 mm

Battery life

5 years typical with min.

equipment. 0QV45LS1000

10 litre/sec, V-angle 45°

0QV60LS2000

20 litre/sec, V-angle 60°

0QV90LS5000

50 litre/sec, rectangular V-notch weirs are preferred for

>21.000 combined measurements Measuring Interval

low discharges as the head above

Programmable

the weir crest is more sensitive

min 1 sec, max 18 hours

measuring interval 1 min.

to changes in flow compared to rectangular weirs.

0QVLIV10000 LEVEL TRANSDUCER

* nominal value based on using WLL at sea level ** typical error using reference level measurement and

Transducer type

Accessories

0WSBHW10000 manager software

support head

Lockable support head assembly

This software permits to check the logger status: verify logger

0P200CH1000

with data plate. Positioned on the

set-up before launch, verify logger operation while logging,

top of the standpipe permits to

display real-time sensor readings and display memory used and

suspend the transducer by a secure

battery voltage. Software’s powerful graphing features allows

cable stop.

plot and filter data for a customized data presentation.

floating unit with high sensitivity load cell

the barometric compensation Measuring range

1000 mm of water level

Sensor resolution

1 mm

Accuracy

< 0.3% FS

Output signal

4-20 mA (current loop)

0P251Q10000 LEVEL TRANSDUCER Transducer type

pressure transmitter

Measuring range

1000 mm of water level

VENTED BOX

Vented IP67 plastic box equipped

Accuracy

< 0.5% FS

0EPDP002W00

with overvoltage protections and

Output signal

4-20 mA (current loop)

cable glands.

STAFF GAUGES (*) including hysteresis and repeatability, calculated with 3rd

0QVHI030000

300mm long, millimetre division

degree polynomial

0QVHI050000

500mm long, millimetre division

sisgeo.com

piezometers

17