"Nothing Seems to Work!" Flow Chart If nothing seems to work, follow Troubleshooting Flow Chart below to identify the problem:
yes
no
For 240 VAC systems:
Verify if keypad is connected correctly to board. All eight pins must be plugged in and black wire must be on top of the plug.
Do you read ≈ 240 VAC between line 1 & line 2, ≈ 120 VAC between line 1 & neutral, ≈ 120 VAC between line 2 & neutral on the board? For 120 VAC systems: Do you read ≈ 120 VAC between line 1 & neutral?
There is an electrical wiring problem. Call an electrician.
Is there a jumper cable connected between line 2 & neutral?
Replace Spa Pack if there is still nothing on keypad display.
SC-CF & SC-MP Service Manual
37