Page 48 ยง 5.2.4. Diagnostic Test Check to ensure that every function of the splicer is normal by performing the diagnostic test. See ยง 6.6.2 'Diagnostic Test Function' on Page73.

ยง 5.2.5. Complete Discharge of Battery Pack It is necessary to completely discharge the battery pack every month in order to prevent its degradation. See ยง 6.6.5 'Battery Pack Discharging Function' on Page78.

ยง 5.2.6. Rotating Cleave Blade If the cleaver does not cleave properly, rotate the blade 1/16th of a turn to replace the worn out blade position with a sharp blade position. 1. Remove the blade cover. I Note r Be careful not to touch the blade as this could cause damage to the blade. 2. Using a small slotted screwdriver, loosen the blade lock screw. 3. Rotate the circular blade 1/16th of a turn. Notez: When rotating the blade, do not touch the cutting edge. Move the blade with a thin cotton swab for eas ' and safe rotation. 4. Tighten the blade lock screw. 5. Attach the blade cover. Blade Height Adjustment After the circular blade has been rotated a complete revolution (16 positions), its height needs to be adjusted to compensate for the wear. 1. Loosen the blade lock screw. 2. Using a .89mm hex wrench, loosen the adjuster lock screw. 3. Using a 1.5mm hex wrench, turn the adjuster clockwise so that the reference dot aligns with the next position mark. Never attempt to rotate the adjuster more than 2 position marks. 4. Tighten the adjuster lock screw. 5. Tighten the blade lock screw. Now the 16 blade positions may be used again. If the cleaver does not cleave properly, rotate the blade.

Adjuster initial position

I i I I

irection of rotation

Fig. 5-1. Rotating Cleave Blade & Figure. Blade Height Adjustment Blade Replacement After the circular blade has been raised 3 times it needs to be replaced. Contact your Fujikura splicer distributor.


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.