Basic Operation 2. Inserting Power Supply to Splicer For AC operation or DC operation with external battery, use AC adapter (ADC-13). For battery operation, use detachable battery (BTR-08). The Power Unit Dock, located on the splicer body, can accommodate both power supplies (ADC-13 and BTR-08).

2-1. Inserting or detaching power unit Inserting power supply unit Insert power unit into Power unit dock until it clicks into place. Detaching power supply unit. Turn off the splicer before removing the power unit. Press the release button, located on the side of the splicer body, and remove the unit from the other side of the release button.

Insert

Release button

2-2. AC Operation Plug the supplied AC cord into the AC inlet of the AC adapter. The power ON LED in the AC adapter turns on (green color) when suitable AC voltage is supplied. If high AC Voltage is supplied, the AC adapter will immediately be damaged. AC generators commonly produce abnormally high AC output voltage or irregular frequencies. Measure the Insert Power ON LED output AC voltage with a circuit tester before connecting (Green) the AC power cord. Such abnormally high voltage or frequency from a generator may cause fuming, electric shock or equipment damage and may result in personal injury, death or fire. Make sure the generator is regularly checked and serviced.