FHGraham | BA Hons. Architecture, Newcastle University | Stage 2 Portfolio

Page 66

tectonic / constructional study – critical junctions (2) window detail-1:10

window head+sill details – 1:5

Timber Lintel

Damp Proof Course - Cavity Tray Cavity barrier, provides drainage and allows Breather Membrane to fold under cladding.

Breather Membrane

Com-­‐ pressible Filler

Fire Insulate Vapour Control Layer

Folds under cladding

Folds under to window

Insula ng cavity tray

Sealant Window Head & Lintel Need to be level (stop air infiltra on)

Triple Glazing

Insula on for Window Reveal Air Tightness Tape

Argon Filled

Sealant Compressible Filler Vapour Control Layer

Breather Membrane Folds under window to in-­‐ ternal window reveal

Folds over to win-­‐ dow

Protects junc on & allows water to run off

Cill Solid to close cavity

Insula on Compact fit

Damp Proof Course (below window and under sill)

Sealant Internal Window Sill

Insula on for Window Reveal