¿µ¹®Ä«´Ù·Ï_New09_Á¤¸®

Page 1




We, at DENTIS, strive to build a “Safe & Clean Implant�image to our dental professionals and patients. We aim to manufacture the safest & cleanest implant products in the world.


Cleanlant System

CONTENTS

Ⅰ. Cleanlant System Selection 1. Fixture System 2. Abutment System

06

II. Features of Cleanlant 1. Surface Treatment 2. Cleaning System 3. Features of Implant

12

III. Uses of Cleanlant Abutment System 1. Uses of i-Clean Abutment 2. Uses of s-Clean Abutment 3. Uses of e-Clean Abutment

24

IV. Cleanlant System Flow _ i-Clean System(Tapered & Straight) & SAVE _ s-Clean System(Tapered & Straight) & SAVE _ e-Clean System(Tapered) _ I-Fix System

30

Ⅴ. Cleanlant Surgical KIT _ Features of Surgical Kit _ Combined KIT _ Straight KIT _ SAVE KIT _ I-Fix KIT _ PROKIT _ Surgical Tools _ SAVE Surgical Tools _ I-Fix Surgical Tools

88

08 10

14 15 18

26 28 29

32 52 72 84

90 92 94 96 97 98 99 104 105


A crystal of engineering skills with a soul Cleanlant


I

Cleanlant System Selection



08 | 09

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit



10 | 11

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


“Safe�- Cleanlant A Gift of the Top Engineering Skills Comfortable and strong natural looking teeth manufactured with pinpoint precision and accuracy without room for the slightest gap. Cleanlant System has improved through innovation to overcome many obstacles existing in other products during surgery such as ensuring the range of vision and the distance between the upper and lower teeth.


II

Features of Cleanlant System


1. Surface Treatment 1.Surface Treatment Using RBM Treatment, the surface of the implant is blasted using CaP powder to increase cohesion of osseo tissue, followed by thorough cleaning of the surface. The roughness is 1.5±0.2um and the surface magnification power is about 192% after surface treatment.

Dimensional Interactive Display

Surface Stats

Ra : 1.70um Rq : 2.13um Rt : 17.23um

Measurement Info

Magnification : 19.86 Measurement Mode : VSI Sampling : 498.41nm Array Size : 640×480

Surface Stats

Ra : 1.67um Rq : 2.08um Rt : 16.86um

Surface Stats

Magnification : 19.86 Measurement Mode : VSI Sampling : 498.41nm Array Size : 640×480

2. Condition of Surface

× 50

× 250

× 500

× 5,000

× 2,000

× 1,200


2. Cleaning System

Cutting Oil Removal

Acid Cleaning

Removal of Cutting Oil Stuck to the Product from the CNC Manufacturing Process

Protein Removal

Product Inspection

Neutral Detergent Cleaning 1

Inspection of Washed Product After the Neutral Detergent Cleaning

Cleaning Two Times Using Neutral Detergent

Cleaning using Neutral Detergent 2

Cleaning Using Distilled Water

Cleaning Three Times Using Neutral Detergent

Cleaning Three Times using Distilled Water

Final Inspection

Drying

The Result of the EDS Analysis of the Elements

Drying of Product after Cleaning

14 | 15

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


3. Analysis of the Elements on the Surface

Element

Wt%

At%

NK Tik Matrix

03.92 96.08 Correction

12.25 87.75 ZAF

Element

Wt%

At%

NK OK PK CaK TiK Matrix

01.31 05.78 02.88 01.31 88.71 Correction

03.83 14.86 03.83 01.35 76.13 ZAF

Because of the exposure of the titanium to the air, detergent and remaining cutting oil, various organic matters are existed on the surface of the dental implant around 0.3 to 1nm. In addition, the existing elements such as Ca, P, N, Si, S and Cl can be identified even though there might be minute traces of them. The small quantities of the above elements and organic matters are not reported to harm the human body yet. However DENTIS Company controls its washing process to minimize any residue and proves its washing validity through testing sample of the surface of every lot number which we produce.


4. Analysis of the Elements on the Surface with ICP/IC DENTIS controls excellent clean level by developing and building DENTIS Cleaning System. Sample

Element

DENTIS

AI

Ca

Cu

Na

N.D.

0.052

P

Si

Zn

F+

0.127

CI+ NO₂ + NO₃ + PO₄ + PO₄ + ³ ²

N.D.

N.D.

N.D.

N.D.

N.D.

0.04

N.D.

0.04

N.D.

0.13

A

0.033 0.181 0.013

N.D.

0.429 0.967 0.010

0.02

0.14

0.04

0.63

1.4

1.03

B

0.011 0.244

N.D.

N.D.

N.D.

0.103 0.005

0.01

0.18

0

0.14

0

0.51

C

N.D.

0.274 0.009

N.D.

0.103 0.161 0.007

0.05

0.39

0.02

0.34

0.41

0.6

D

0.065 0.156 0.005

N.D.

N.D.

0.01

0.14

0.03

0.1

0

0.33

0.294

N.D.

ICP, IC Quantitative Analysis

5. The Cytotoxicity Test Result According to ISO 10993-5, the cytotoxicity test result

Final Inspection

Negative Control Group

Positive Control Group

DENTIS Fixture Eluted Fluid Group

After DENTIS Eluted Fluid Group treated with L929 fibroblast for 24hours, the test result showed that it is not effect on the growth like Media Control Group and Negative Control Group at all.

16 | 17

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


3. Features of Cleanlant 1. The 3 Types of Fixture Design for Various Cases Its products have been developed to be applied to various clinical cases and provide 3 types of fixture, i-Clean, e-Clean and s-Clean, for parts that need esthetics and according to the condition of the bone. 2. Convenient Compatibility of Superstructure Cleanlant is economical to use with the certain products such as Branemark, ITI, Astra, and Swissplus implants. 3. Optimum RBM Surface Treatment Roughness measurement of the surface is Ra: 1.5~1.8um. This measurement is the most ideal value for osseointegration.

Ă— 5,000 1

3

4. i-Clean/ s-Clean Fixture is No-mount System During surgery, existing Mount System obstructs the range of vision and the distance between the upper and lower teeth, however DENTIS No-mount system can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects by the surrounding teeth.

4


3-1. Features of Tapered Body Implant

× 50 1

2

3

1. Micro-thread for Bone Loss Prevention Cleanlant Micro-thread minimizes bone loss, bone stress and appropriate stimulus of the cortical bone together with stable initial fixation. 2. Tapered Design and Rotating Safe Cutting Edge for Smooth Drilling It has been designed for excellent osseointegration as well as excellent initial fixation as it remarkably reduces excessive friction with the bone due to uniform transmission of strength during insertion owing to safe cutting edge that follows the direction of the rotation. The cutting edge is on the whole body of the fixture and has tapered design and double thread. 3. e-Clean Mount for Impression and Abutment e-Clean Mount is economical and makes it simple for dental prosthetics. Mount could be used as Impression Coping (Transfer) and final abutment, after insertion.

18 | 19

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


3-2. Features of Straight body implant 1. Designed for Smooth Insertion in Various Bone Densities. Cleanlant straight type is designed for smooth insertion in various bone densities, allowing not giving excessive bone stress and secure insertion. 2. Design for Excellent Initial Stability Double thread design provides the reducing insertion time and increasing the initial stability. When placing the implant, it helps self-tapping and allowing the space for the bone, increasing the initial stability. Apex 5°tapered design guiding for placing implant at drilling hole.

3-3. Features of SAVE implant If a necessary initial fixation is not obtained because of the loss of a wide fixture or the widening of the alveolar bone during surgery. By using SAVE, implantation can be performed immediately, and sufficient initial fixation can be obtained, allowing the successful completion of the implantation. 1. Platform Switching Further loss of the alveolar bone is not allowed. It reduces alveolar bone loss to the maximum in the fixture shoulder region using Platform Switching Process. 2. Convenient Compatibility of Superstructure It is economical to use with Cleanlant superstructure so there is no need for additional SAVE Abutment System. 3. SAVE System


3-4. Features of I-Fix implant 1. Three Types of Fixture

Post Type

O-Ring Type

Angled Type

Suitable for narrow space in the maxillary and mandibular anterior teeth

Suitable for the edentulous patients

Specialized 2 pieces-design reinforce safe fixation

Creating fast and simple temporary prosthesis

Abutments are divided into Cemented and Angled for various cases and placement direction

One-body type design provides maximum strength for mastication

Take fast, convenient impressions with 2 types of impression coping in narrow space

Post Type

O-Ring Type

Angled Type

2㎜ 4㎜

1.5㎜ 3.5㎜

1.3㎜ 3.3㎜

Collar

Angled Type Cemented Abutment Cuff

0.7㎜

Angled Abutment 0.7㎜

Post type Neck design Neck design helps to make fast healing time

2.7㎜ 2㎜ (Driver connection area)

O-Ring Type Collar

1.5 / 3.5㎜

Usable with regular size of retainer furthermore o-ring cap is available Collar heights are 1.5mm and 3.5mm 15°

O-Ring Cap

0.7㎜ 1.3㎜

O-Ring

Angled Type - Collar+Cuff Total gingival height is collar (1.3mm or 3.3mm) + cuff height (0.7)

20 | 21

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


2. 2 pieces-type with Maximum Strength 1. The fixation is strong and safe between screw and fixture with over 4 and half pitch screw connection 2. Morse taper connection between the implant and the abutment offers the friction locking and sealing 3. Torque recommendation : 30-35Ncm

3. Another Function of Angled Type Mount

- 0.9 Hex Driver -

Mount is used as healing abutment and cover screw after placement.

4. Angled Type - Free Abutment Free, easy milling and prosthesis work as the application of DENTIS regular free abutment Groove in the abutment body - Strong fixation with cement


5. For use where Narrow Interproximal Space

Impression Coping Height 12㎜

18㎜

12㎜

18㎜

23㎜

Three types of impression coping available in various pick-up impression cases

23㎜

18mm and 23mm impression copings provide convenient impression-taking in narrow interproximal space.

in the case of interference from neighboring teeth.

Height 18mm, 23mm impression coping

6. Easy Surgical Tool One driver fits all 3types of screw

Short

Long

Machine Driver

Post type

22 | 23

ⅠGuide

Ⅱ Technique

O-Ring type

Angle type

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


“Simple and Convenient�Surgery Cleanlant Cleanlant system that is upgraded day by day helps accurate and safe implant surgery. DENTIS patented engineering skills induces smooth insertion, does not induce extreme to the patient, is greatly convenient, and surgery can be performed fast and simply.


III

Uses of Cleanlant Abutment System


1. Uses of i-Clean Abutment System

1) Uses of Solid Abutment Generally, it is used when getting the abutment Level impression of i-Clean type and can be used in all cases, single unit and multi unit, to make cemented type prosthesis.

2) Uses of Excellent Abutment In molar cases, when abutment is smaller than the size of the prosthesis, it increases the size of the normal solid abutment, and possesses stability.

3) Uses of InOcta Abutment It is used for making SCRP dental prosthesis and in choosing cuff of the abutment to suit the thickness of the gingiva when part of the implant shoulder is being drilled under the gums and getting an impression in the fixture level.

4) Uses of SyncOcta Abutment It can be used in all cases, single unit and multi unit and getting an impression in the fixture level. As all stages of dental prosthesis production is possible in the lab, chair time is reduced. This is Cemented Type and is possible to make SCRP dental prosthesis.


5) Uses of Gold ULCA Abutment It is used when the opposing of surfaces of the teeth of the two jawbones does not come into contact and the dentist makes screw type prosthesis.

6) Uses of Angled Abutment It is prepared in 15 and 25 degrees and can be used in cases to compensate for the angle and the insertion path is not good.

7) Uses of Octa Abutment It is used when prosthesis requires screw type, or cases of multiple unit that does not have a good path.

8) Uses of O-Ring Abutment It is used for over denture.

26 | 27

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


2. Uses of s-Clean Abutment System

1) Uses of Sole Abutment Generally, it is used when getting the Abutment Level impression of s-Clean type and can be used in all cases, single unit and multi unit, to make cemented type prosthesis.

2) Uses of Couple Abutment It can be used in all cases, single unit and multi unit and getting an impression in the fixture and abutment level. As all stages of dental prosthesis production is possible in the lab, chair time is reduced. This is cemented type and is possible to make SCRP dental prosthesis.

3) Uses of Gold UCLA Abutment It is used when the opposing of surfaces of the teeth of the two jawbones does not come into contact and the dentist makes screw type prosthesis.

4) Uses of Angled Abutment It is prepared in 15 and 25 degrees and can be used in cases to compensate for the angle and the insertion path is not good.

5) O-Ring Abutment It is used for over denture.


3. Uses of e-Clean Abutment System

1) Uses of Cemented Abutment Generally, it is used when making dental prosthesis of the cemented type.

2) Uses of Estheticone Abutment It is used when prosthesis requires screw type, or cases of multiple unit that does not have a good path.

3) Uses of Angled Abutment It is prepared in 15 and 25 degrees and can be used in cases to compensate for the angle and the insertion path is not good.

4) Uses of Gold UCLA Abutment It is used when the opposing of surfaces of the teeth of the two jawbones does not come into contact and the dentist makes screw type prosthesis.

5) O-Ring Abutment It is used for over denture.

28 | 29

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Natural-looking teeth like its part of your body - Cleanlant RBM Surface Treatment minimizes danger of contamination accounted to foreign matter. Produce teeth shaped like the natural teeth and surpasses esthetic appreciation. It is semi-permanent as it made of superior materials.


IV

Cleanlant System Flow


i-Clean System Flow

“Convenient”No-mount System During surgery, existing Mount System obstructs the range of vision and the distance between the upper and lower teeth, however DENTIS Nomount system can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects from the surrounding teeth. Octa Octa Connection prosthesis is compatible with superstructures of ITI and Swissplus. Tapered design Root Form Design achieved superb initial fixation strength also in places where condition of the bone is not good, makes an easy and stable surgery possible and reduces surgery time. 2.0mm Machined collar

Micro-Thread for Bone Loss Prevention It prevents water absorption of the cortex due to bacterial infection and minimizes bone loss, breaking due to i-Clean stress and stimulus of the cortical bone with stable initial fixation strength and wedges in thin cortex as well. RBM Surface Treatment (1.5±0.2um) It maximizes osseointegration. × 5,000 Safe cutting edge It minimizes resistance of the bone during insertion of the implant and functions to provide safe and smooth insertion. Self-tapping Groove It helps self-tapping during the insertion of the implant and at the same time be the space for bone chips. In addition, boost fixation strength after insertion.


System

ø4.8

Mini

ø4.8 Implant Diameter

2.0㎜

L

ø3.7

Platform Diameter

ø4.8

Length

Code

8.0mm

DIFM3708

10.0mm

DIFM3710

12.0mm

DIFM3712

14.0mm

DIFM3714

ø3.0 ø3.7

ø4.8

Regular

ø4.8 Implant Diameter

2.0㎜

L

ø4.3

Platform Diameter

ø4.8

Length

Code

8.0mm

DIFR4308

10.0mm

DIFR4310

12.0mm

DIFR4312

14.0mm

DIFR4314

ø3.6 ø4.3

ø4.8

Wide

ø4.8 Implant Diameter

2.0㎜

Platform Diameter

L ø4.8

ø4.8

Length

Code

8.0mm

DIFWR4808

10.0mm

DIFWR4810

12.0mm

DIFWR4812

14.0mm

DIFWR4814

ø4.1 ø4.8

32 | 33

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


i-Clean System Flow

Designed for Smooth Insertion in Various Bone Densities Cleanlant straight type is designed for smooth insertion in various bone densities, allowing not giving excessive bone stress and secure insertion.

Convenient Compatibility of Superstructure Cleanlant is economical to use with the certain products such as ITI and Swissplus implants.

“Convenient”No-mount System During surgery, existing Mount System obstructs the range of vision and the distance between the upper and lower teeth, however, DENTIS No-mount System can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects from the surrounding teeth.

Octa Octa connection prosthesis is compatible with superstructure of ITI and Swissplus.

RBM Surface Treatment (1.5±0.2um) It maximizes osseointegration.

R0.65

Design for Excellent initial stability

0.1mm

Double thread design provides the reducing insertion

0.9mm

time and increasing the initial stability. When placing the implant, it helps self-tapping and allowing the space for the bone, increasing the initial stability. Apex 5°tapered design guiding for placing implant at drilling hole. 5˚


System

ø4.8 0.65㎜ 2㎜

L

ø4.1

Implant Diameter

ø4.1

Platform Diameter

ø4.8

Collar

Length

Code

2mm

8mm

DISF4108L

2mm

10mm

DISF4110L

2mm

12mm

DISF4112L

2mm

14mm

DISF4114L

Collar

Length

Code

2mm

8mm

DISF4808L

2mm

10mm

DISF4810L

2mm

12mm

DISF4812L

2mm

14mm

DISF4814L

ø4.8 0.65㎜ 2㎜

L

ø4.8

Implant Diameter

ø4.8

34 | 35

ⅠGuide

Platform Diameter

ø4.8

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


SAVE Internal System Flow

Internal Fixture

“Convenient”No-mount System During surgery, existing Mount System obstructs the range of vision and the distance between the upper and lower teeth, however DENTIS Nomount system can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects by the surrounding teeth.

Micro-thread for Bone Loss Prevention Micro-thread minimizes bone loss, breaking due to internal stress and appropriate stimulus of the cortical bone together with stable initial fixation.

Optimum RBM Surface Treatment Roughness measurement of the surface is Ra: 1.5±0.2um. This measurement is the most ideal value for osseointegration.

× 50

× 5,000

Safe Cutting Edge/ Tapered Design It has been designed for excellent osseointegration as well as excellent initial fixation as it remarkably reduces excessive friction with the bone due to uniform transmission of strength during insertion.


Internal System

ø5.5 SAVE Internal Fixture Size

ø6.0 0.65㎜ 2.0㎜

10.0㎜

ø4.8 ø5.5

Implant Diameter

Platform Diameter

ø6.0

ø5.5

Length

Code

7.0mm

DIFS5507

8.0mm

DIFS5508

10.0mm

DIFS5510

12.0mm

DIFS5512

ø6.0 SAVE Internal Fixture Size

ø6.0 0.65㎜ 2.0㎜

10.0㎜

ø5.3 ø6.0

Implant Diameter

ø6.0

36 | 37

ⅠGuide

Platform Diameter

ø6.0

Ⅱ Technique

Length

Code

7.0mm

DIFS6007

8.0mm

DIFS6008

10.0mm

DIFS6010

12.0mm

DIFS6012

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for i-Clean

Solid System

Single

Bridge

Plasitc Coping

Lab Analog

Solid Abutment Driver

Impression Caps Positioning Cylinder

Shoulder Analog & Pin

Solid Abutment

Excellent Solid Abutment

Excellent Solid Abutment Driver

Cover Screw

Healing Abutment

1.2 Hex Driver

i-Clean


Solid Abutment System Closing Screw

Cover Screw

2mm

Platform Diameter

Cuff

Code No.

Ø4.8

0mm

DICS3

Platform Diameter

Cuff

Code No.

Ø4.8

2mm

DICS1

Ø6.0

2mm

DISCS60

Platform Diameter

Cuff

Code No.

Ø4.8

3mm 4mm 5.5mm

DIH30 DIH40 DIH55

Ø6.0

3mm 4mm 5.5mm

DIHS30 DIHS40 DIHS55

Platform Diameter

Length

Code No.

Ø4.8

4mm 5.5mm 7mm

DISA40 DISA55 DISA70

Ø6.0 : SAVE Only

Healing Abutment

Cuff: 3, 4, 5.5mm

Ø6.0 : SAVE Only

Solid Abutment

L: 4, 5.5, 7m

38 | 39

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Excellent Solid Abutment

Platform Diameter

Length

Code No.

Ø4.8

4mm 5.5mm 7mm

DIESA40 DIESA55 DIESA70

Platform Diameter

Type

L: 4, 5.5, 7m

Impression Cap

DISICR

Ø4.8

Positioning Cylinder

Platform Diameter Ø4.8

Code No.

Type

Code No. DISIPCR


Solid Abutment System Lab Analog

Platform Diameter

Length

Ø4.8

4mm 5.5mm 7mm

Code No. DISLA40 DISLA55 DISLA70

L: 4, 5.5,7mm

Shoulder Analog & Pin

Platform Diameter

Code No. DIISAR DISAPR

Ø4.8

Plasitc Coping

Platform Diameter

Type

Code No.

Ø4.8

Single Bridge

DISPS DISPB

Single

Bridge

40 | 41

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for i-Clean

InOcta System

Octa

N-Octa

Free Abutment

Octa

N-Octa

InOcta Abutment

15。

25。

Angled Abutment

Octa

N-Octa

SynOcta Abutment

Octa

N-Octa

Gold UCLA

Lab Analog

Impression Coping(Pick-up)

Impression Coping(Transfer)

Healing Abutment

Cover Screw

i-Clean

1.2 Hex Driver


InOcta Abutment System Impression Coping

Platform Diameter

Type

Ø4.8

Pick-Up

DIPIR

Transfer

DITIR DITIN

Pick-Up

DIPIS60

Ø6.0

Code No.

Ø6.0 : SAVE Only

Pick-Up

Transfer

Lab Analog

Platform Diameter

Code No.

Ø4.8

DILA

Ø6.0

DILAS

Ø6.0 : SAVE Only

42 | 43

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Free Abutment

Type

Platform Diameter

Code No.

Octa N-Octa

DIFAO DIFAN

Octa

N-Octa

InOcta Abutment

Platform Diameter

Type

Cuff

Code No.

Ø4.8

Octa

1mm 2mm 3mm 4mm

DICO10 DICO20 DICO30 DICO40

N-Octa

1mm 2mm 3mm 4mm

DICO10N DICO20N DICO30N DICO40N

Octa

1mm 2mm 3mm 4mm

DICOS10 DICOS20 DICOS30 DICOS40

N-Octa

1mm 2mm 3mm 4mm

DICOS10N DICOS20N DICOS30N DICOS40N

6mm

Octa

Ø6.0

Cuff:1, 2, 3, 4mm N-Octa

Ø6.0 : SAVE Only

Angled Abutment

15。

25。

Platform Diameter

Type

Code No.

Ø4.8

15。 25。

DIAA15 DIAA25


InOcta Abutment System SynOcta Abutment

Platform Diameter

Type

Ø4.8

Octa N-Octa

Platform Diameter

Type

Ø4.8

Octa N-Octa

Code No. DISOA DISOAN

Octa

N-Octa

Gold UCLA

Octa

Code No. DIGUO DIGUN

N-Octa

Temporary Abutment

Platform Diameter

Type

Cuff

Code No.

Ø4.8

Octa

1mm 2mm 3mm 4mm

DITA10O DITA20O DITA30O DITA40O

N-Octa

1mm 2mm 3mm 4mm

DITA10N DITA20N DITA30N DITA40N

Cuff:1, 2, 3, 4mm

Octa

Cuff:1, 2, 3, 4mm

N-Octa

44 | 45

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for i-Clean

Octa System

Hex

N-Hex

Octa

Gold Cylinder

N-Octa

Plastic Cylinder

Octa Lab Analog

Impression Coping(Transfer)

Impression Coping(Pick-up)

Octa Abutment

Healing Abutment

Cover Screw

i-Clean

Octa Abutment Driver

1.2 Hex Driver


Octa Abutment System Octa Abutment

Platform Diameter

Code No. DIOA

Ø4.8

Octa Healing Cap

Platform Diameter

Code No. DIOHC

Ø4.8

Impression Coping

Platform Diameter

Type

Code No.

Ø4.8

Pick-Up

DIOIO DIOIN

Transfer

DIOTI DITIN

Pick-Up

Transfer

46 | 47

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Lab Analog

Platform Diameter

Code No. DIOLA

Ø4.8

Gold Cylinder

Octa

N-Octa

Platform Diameter

Type

Code No.

Ø4.8

Octa N-Octa

DIOGCO DIOGCN


Octa Abutment System Plastic Cylinder

Platform Diameter

Type

Code No.

Ø4.8

Octa N-Octa

DIOPO DIOPN

Octa

N-Octa

48 | 49

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for i-Clean

O-Ring System

O-Ring

O-Ring Retainer

O-Ring Lab Analog

O-Ring Abutment Driver

O-Ring Abutment

Healing Abutment

Cover Screw

i-Clean

1.2 Hex Driver


O-Ring Abutment System O-Ring Abutment

Abutment Diameter

Cuff

Code No.

Ø3.5

0mm 2mm 4mm

DIORA00 DIORA20 DIORA40

Cuff: 0, 2, 4mm

Code No.

O-Ring Lab Analog

DOLA

Code No.

O-Ring Retainer

DOR

Code No.

O-Ring

ORING

50 | 51

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


s-Clean System Flow

“Convenient”No-mount System During surgery, existing Mount System obstructs the range of vision and the distance between the upper and lower teeth, however DENTIS Nomount system can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects from the surrounding teeth. Hex Hex Connection prosthesis is compatible with the superstructure with products of Astra. Tapered design Root Form Design achieved superb initial fixation strength also in places where condition of the bone is not good, makes an easy and stable surgery possible and reduces surgery time. Micro-Thread for Bone Loss Prevention It prevents water absorption of the cortex due to bacterial infection and minimizes bone loss, breaking due to i-Clean stress and stimulus of the cortical bone with stable initial fixation strength and wedges in thin cortex as well. RBM Surface Treatment (1.5±0.2um) It maximizes osseointegration. × 5,000 Safe cutting edge It minimizes resistance of the bone during insertion of the implant and functions to provide safe and smooth insertion. Self-tapping Groove It helps self-tapping during the insertion of the implant and at the same time be the space for bone chips. In addition, boost fixation strength after insertion.


System

ø3.7

ø3.7

Mini

0.4㎜

L

Implant Diameter

ø3.7

ø3.0

Platform Diameter

ø3.7

ø3.7

Length

Code

8.0mm

DSFM3708

10.0mm

DSFM3710

12.0mm

DSFM3712

14.0mm

DSFM3714

ø4.3

ø4.3

Regular

0.4㎜

L

Implant Diameter

ø4.3

ø3.6

Platform Diameter

ø4.3

ø4.3

Length

Code

8.0mm

DSFR4308

10.0mm

DSFR4310

12.0mm

DSFR4312

14.0mm

DSFR4314

ø4.8

ø4.8 0.4㎜

Wide L

ø4.1

Implant Diameter

ø4.8

ø4.8

52 | 53

ⅠGuide

Ⅱ Technique

Platform Diameter

ø4.8

Length

Code

8.0mm

DSFW4808

10.0mm

DSFW4810

12.0mm

DSFW4812

14.0mm

DSFW4814

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


s-Clean System Flow

Designed for Smooth Insertion in Various Bone Densities Cleanlant straight is designed for smooth insertion in various bone densities, allowing not giving excessive bone stress and secure insertion.

Convenient Compatibility of Superstructure Cleanlant is economical to use with the certain products such as Astra implants.

Hex Hex Connection prosthesis is compatible with the superstructure with products of Astra.

“Convenient”No-mount System During surgery, existing Mount System obstructs the range of vision and the distance between the upper and lower teeth, however, DENTIS No-mount System can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects from the surrounding teeth.

RBM Surface Treatment (1.5±0.2um) R0.65

0.9mm

It maximizes osseointegration.

Design for Excellent initial stability 0.1mm

Double thread design provides the reducing insertion time and increasing the initial stability. When placing the implant, it helps self-tapping and allowing the space for the bone, increasing the initial stability. Apex 5°tapered design guiding for placing implant at drilling hole. 5˚


System

L

ø4.1

Implant Diameter

ø4.8

Length

Code

8mm

DSSF4108

10mm

DSSF4110

12mm

DSSF4112

14mm

DSSF4114

L

ø4.8

Implant Diameter

ø4.8

54 | 55

ⅠGuide

Length

Code

8mm

DSSF4808

10mm

DSSF4810

12mm

DSSF4812

14mm

DSSF4814

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


SAVE Submerged System Flow

Submerged Fixture “Convenient”No-mount System During surgery, existing Mount System obstructs the range of vision and the distance between the upper and lower teeth, however DENTIS Nomount system can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects by the surrounding teeth. Convenient Compatibility of Superstructure It is economical to use with Cleanlant superstructure so there is no need for additional SAVE Abutment System. Platform Switching System Further loss of the alveolar bone is not allowed. It reduces alveolar bone loss to the maximum in the Fixture Shoulder region using Platform Switching Process. Micro-thread for Bone Loss Prevention Cleanlant Micro-thread minimizes bone loss, breaking due to internal stress and appropriate stimulus of the cortical bone together with stable initial fixation. Optimum RBM Surface Treatment Roughness measurement of the surface is Ra: 1.5±0.2um. This measurement is the most ideal value for osseointegration.

× 5,000

Safe Cutting Edge/ Tapered Design It has been designed for excellent osseointegration as well as excellent initial fixation as it remarkably reduces excessive friction with the bone due to uniform transmission of strength during insertion.


Submerged System

ø5.5 SAVE Submerged Fixture Size

ø5.5 0.4㎜

10.0㎜

ø4.8 ø5.5

Implant Diameter

ø5.5

Platform Diameter

ø5.5

Length

Code

7.0mm

DSFS5507

8.0mm

DSFS5508

10.0mm

DSFS5510

12.0mm

DSFS5512

ø6.0 SAVE Submerged Fixture Size

ø6.0 0.4㎜

10.0㎜

ø5.3 ø6.0

Implant Diameter

ø6.0

56 | 57

ⅠGuide

Platform Diameter

ø6.0

Ⅱ Technique

Length

Code

7.0mm

DSFS6007

8.0mm

DSFS6008

10.0mm

DSFS6010

12.0mm

DSFS6012

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for s-Clean

Sole System

Single

Bridge

Plastic Coping

Lab Analog

Impression Cap

Sole Abutment

Healing Abutment

Cover Screw

s-Clean

1.25 Hex Driver

1.25 Hex Driver


Sole Abutment System Abutment Diameter

Cover Screw

Code No. DSCSM

Healing Abutment

Abutment Diameter

Cuff

Code No.

Ø4.5

1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

DSH4510 DSH4515 DSH4520 DSH4525 DSH4535 DSH4545 DSH4555

Ø5.5

1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

DSH5510 DSH5515 DSH5520 DSH5525 DSH5535 DSH5545 DSH5555

Ø6.5

1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

DSH6515 DSH6520 DSH6525 DSH6535 DSH6545 DSH6555

ø4.5, 5.5, 6.5

2mm Cuff: 1.0, 1.5, 2.0,2.5, 3.5, 4.5, 5.5mm

58 | 59

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Sole Abutment

Abutment Diameter

Cuff

Length

Code No.

Ø4.5

1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

5.5mm

DSSA4510 DSSA4515 DSSA4520 DSSA4525 DSSA4535 DSSA4545 DSSA4555

5.5mm Cuff: 0.8,1.5,2.0, 2.5, 3.5, 4.5, 5.5mm

Ø5.5

Ø6.5

Impression Cap

1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

5.5mm

5.5mm

DSSA5510 DSSA5515 DSSA5520 DSSA5525 DSSA5535 DSSA5545 DSSA5555 DSSA6515 DSSA6520 DSSA6525 DSSA6535 DSSA6545 DSSA6555

Abutment Diameter

Code No.

Ø4.5

DSIPC45

Ø5.5

DSIPC55

Ø6.5

DSIPC65


Sole Abutment System Lab Analog

Plastic Coping

Abutment Diameter

Code No.

Ø4.5

DSSLA45

Ø5.5

DSSLA55

Ø6.5

DSSLA65

Abutment Diameter

Type

Code No.

Ø4.5

Single Bridge

DSSP45S DSSP45B

Ø5.5

Single Bridge

DSSP55S DSSP55B

Ø6.5

Single Bridge

DSSP65S DSSP65B

Single

Bridge

60 | 61

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for s-Clean

Couple System

Hex

N-Hex

Hex

Free Abutment

15。

N-Hex

25。

Hex

Angled Abutment

Couple Abutment

N-Hex

Gold UCLA Abutment

Lab Analog

Hex

Hex

N-Hex

Impression Coping(Pick-up)

N-Hex

Impression Coping(Transfer)

Healing Abutment

Cover Screw

s-Clean

1.25 Hex Driver


Couple Type Abutment System

ø4.5 ø4.5 4.5mm

2.5mm

Cuff

Code No.

Ø4.5 (Free Abutment Only)

0.8mm

DSFH4525 DSFH4545

Ø5.5 (Free Abutment Only)

0.8mm

DSFH5525 DSFH5545

Abutment Diameter

Healing Abutment

ø5.5 ø5.5 4.5mm

2.5mm

Impression Coping

Abutment Diameter

Type

Ø4.5

Pick-Up

Ø5.5

Pick-Up

Hex

Ø6.5

Pick-Up

Length

Code No.

Hex

Long Short

DSIH45L DSIH45S

N-Hex

Long Short

DSIN45L DSIN45S

Hex

Long Short

DSIH55L DSIH55S

N-Hex

Long Short

DSIN55L DSIN55S

Hex

Long Short

DSIH65L DSIH65S

N-Hex

Long Short

DSIN65L DSIN65S

Length

Code No.

Hex

Long Short

DSITH45L DSITH45S

N-Hex

Long Short

DSITN45L DSITN45S

Hex

Long Short

DSITH55L DSITH55S

N-Hex

Long Short

DSITN55L DSITN55S

Hex

Long Short

DSITH65L DSITH65S

N-Hex

Long Short

DSITN65L DSITN65S

N-Hex

Pick-Up Impression Coping

Abutment Diameter

Type

Ø4.5

Transfer

Ø5.5

Transfer

Hex

Ø6.5

Transfer

N-Hex

Transfer

62 | 63

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Code No.

Lab Analog

DSCLA

Free Abutment

Type

Code No.

Ø4.5 Ø5.5

Hex

DSFA45H DSFA55H

Ø4.5 Ø5.5

N-Hex

DSFA45N DSFA55N

Abutment Diameter

N-Hex

Hex

Couple Abutment

Type

Abutment Diameter

Cuff

Hex

Ø4.5

1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

L

Ø5.5

Hex

Cuff

Ø6.5 N-Hex

N-Hex

Ø4.5

Ø5.5

Ø6.5

1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm 1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm 1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

Length

Code No.

5.5mm

DSCA4510H DSCA4515H DSCA4520H DSCA4525H DSCA4535H DSCA4545H DSCA4555H

5.5mm

DSCA5510H DSCA5515H DSCA5520H DSCA5525H DSCA5535H DSCA5545H DSCA5555H

5.5mm

DSCA6515H DSCA6520H DSCA6525H DSCA6535H DSCA6545H DSCA6555H

5.5mm

5.5mm

5.5mm

DSCA4510N DSCA4515N DSCA4520N DSCA4525N DSCA4535N DSCA4545N DSCA4555N DSCA5510N DSCA5515N DSCA5520N DSCA5525N DSCA5535N DSCA5545N DSCA5555N DSCA6515N DSCA6520N DSCA6525N DSCA6535N DSCA6545N DSCA6555N


Couple Type Abutment System Couple Abutment

Type

Abutment Diameter

Cuff

Hex

Ø4.5

1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

L

1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

Ø5.5

Hex

Cuff

N-Hex

N-Hex

1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

Ø6.5

Angled Abutment

DSCA5510H7 DSCA5515H7 DSCA5520H7 DSCA5525H7 DSCA5535H7 DSCA5545H7 DSCA5555H7 DSCA6515H7 DSCA6520H7 DSCA6525H7 DSCA6535H7 DSCA6545H7 DSCA6555H7 DSCA4510N7 DSCA4515N7 DSCA4520N7 DSCA4525N7 DSCA4535N7 DSCA4545N7 DSCA4555N7

7mm

DSCA5510N7 DSCA5515N7 DSCA5520N7 DSCA5525N7 DSCA5535N7 DSCA5545N7 DSCA5555N7

7mm

DSCA6515N7 DSCA6520N7 DSCA6525N7 DSCA6535N7 DSCA6545N7 DSCA6555N7

Abutment Diameter

Cuff

Length

Code No.

Ø4.5

15。

2mm 4mm

DSAA45152 DSAA45154

25。

2mm 4mm

DSAA45252 DSAA45254

15。

2mm 4mm

DSAA55152 DSAA55154

25。

2mm 4mm

DSAA55252 DSAA55254

15。

2mm 4mm

DSAA65152 DSAA65154

25。

2mm 4mm

DSAA65252 DSAA65254

Ø5.5

15。

7mm

1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

Ø5.5

7mm

7mm

1.0mm 1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

Ø4.5

Code No. DSCA4510H7 DSCA4515H7 DSCA4520H7 DSCA4525H7 DSCA4535H7 DSCA4545H7 DSCA4555H7

7mm

1.5mm 2.0mm 2.5mm 3.5mm 4.5mm 5.5mm

Ø6.5

Length

Ø6.5 25。

Gold UCLA

Hex

N-Hex

Abutment Diameter

64 | 65

ⅠGuide

Type

Code No.

Hex

DSGCH

N-Hex

DSGCN

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for s-Clean

Sub Octa System

Hex

N-Hex

Octa

Gold Cylinder

N-Octa

Plastic Cylinder

Octa Lab Analog

Impression Coping(Transfer)

Impression Coping(Pick-up)

Sub Octa Abutment

Healing Abutment

Cover Screw

s-Clean

Octa Abutment Driver

1.25 Hex Driver


Octa Abutment System Sub Octa Abutment

Octa Healing Cap

Abutment Diameter

Cuff

Code No.

Ø4.8

1.0mm 1.5mm 2.5mm 3.5mm 4.5mm 5.5mm

DSOA480 DSOA481 DSOA482 DSOA483 DSOA484 DSOA485

Abutment Diameter

Code No. DIOHC

Ø4.8

Impression Coping

Abutment Diameter

Type

Code No.

Ø4.8

Pick-Up

DIOIO DIOIN

Transfer

DIOTI

Pick-Up

Transfer

66 | 67

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Lab Analog

Abutment Diameter

Code No. DIOLA

Ø4.8

Gold Cylinder

Octa

N-Octa

Abutment Diameter

Type

Code No.

Ø4.8

Octa N-Octa

DIOGCO DIOGCN


Octa Abutment System Plastic Cylinder

Abutment Diameter

Type

Code No.

Ø4.8

Octa N-Octa

DIOPO DIOPN

Octa

N-Octa

68 | 69

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for s-Clean

O-Ring System

O-Ring

O-Ring Retainer

O-Ring Lab Analog

O-Ring Abutment Driver

O-Ring Abutment

Healing Abutment

Cover Screw

s-Clean

1.25 Hex Driver


O-Ring Abutment System O-Ring Abutment

Abutment Diameter

Cuff

Code No.

Ø3.4 Ø4.5 Ø4.5

0.5mm 2mm 4mm

DSORA00 DSORA20 DSORA40

Cuff: 0.5, 2, 4mm

Code No.

O-Ring Lab Analog

DOLA

Code No.

O-Ring Retainer

DOR

Code No.

O-Ring

ORING

70 | 71

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


e-Clean System Flow

Fixture Mount can be used for Imperssion Coping and Free Abutment. Fixture mount is economical and makes it simple for dental prosthetics. Mount could be used as transfer type of impression coping and final abutment after inserted fixture. Tapered design Root Form Design achieved superb initial fixation strength also in places where condition of the bone is not good, makes an easy and stable surgery possible and reduces surgery time. Micro-Thread for Bone Loss Prevention It prevents water absorption of the cortex due to bacterial infection and minimizes bone loss, breaking due to internal stress and stimulus of the cortical bone with stable initial fixation strength and wedges in thin cortex as well.

× 50

Safe cutting edge It minimizes resistance of the bone during insertion of the implant and functions to provide safe and smooth insertion.

RBM Surface Treatment (1.5±0.2um) It maximizes osseointegration.

× 5,000


System ø2.4

ø3.5 0.7㎜

Mini L

ø2.8

Implant Diameter

ø3.5

Platform Diameter

ø3.5

ø3.5

Length

Code

8.0mm

DEFM3508

10.0mm

DEFM3510

12.0mm

DEFM3512

14.0mm

DEFM3514

ø2.7

ø4.1 0.7㎜

Regular Implant Diameter

L

ø3.4

ø4.1

Platform Diameter

ø4.1

ø4.1

Length

Code

8.0mm

DEFR4108

10.0mm

DEFR4110

12.0mm

DEFR4112

14.0mm

DEFR4114

ø3.4

ø5.1 0.7㎜

Wide L

ø4.4

Implant Diameter

ø5.1

ø5.1

72 | 73

ⅠGuide

Ⅱ Technique

Platform Diameter

ø5.1

Length

Code

8.0mm

DEFW5108

10.0mm

DEFW5110

12.0mm

DEFW5112

14.0mm

DEFW5114

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for e-Clean

Cemented System

Hex

N-Hex

Cemented Abut.

15。

25。

Hex

Angled Abut.

N-Hex

Gold UCLA

Hex

N-Hex

Plastic UCLA

Lab Analog

Hex

N-Hex

Impression Coping(Transfer)

Impression Coping(Pick-up)

Healing Abutment

Cover Screw

Mount

e-Clean

1.2 Hex Driver


Cemented Abutment System Mount

Short Mount

Platform Diameter

Code No.

Mini

DEFMM

Regular

DEFMR

Wide

DEFMW

Platform Diameter

Code No.

Mini

DEFMSM

Regular

DEFMSR

Wide

DEFMSW

Platform Diameter

Code No.

Mini

DECSM

Regular

DECSR

Wide

DECSW

6.5mm

Cover Screw

Healing Abutment

Platform Diameter

Cuff

Code No.

Mini

2mm 3mm 4mm 5.5mm 7mm

DEHM420 DEHM430 DEHM440 DEHM455 DEHM470

2mm 3mm 4mm 5.5mm 7mm

DEHR520 DEHR530 DEHR540 DEHR555 DEHR570

2mm 3mm 4mm 5.5mm 7mm

DEHR620 DEHR630 DEHR640 DEHR655 DEHR670

2mm 3mm 4mm 5.5mm 7mm

DEHW620 DEHW630 DEHW640 DEHW655 DEHW670

Cuff: 2, 3, 4, 5.5, 7mm

Regular

Wide

74 | 75

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Impression Coping

Platform Diameter

Type Pick-Up

Code No. Hex N-Hex

DEIM40H DEIM40N

Regular

Hex N-Hex Hex N-Hex

DEIR50H DEIR50N DEIR60H DEIR60N

Wide

Hex N-Hex

DEIW60H DEIW60N

Mini

Pick-Up Impression Coping

Type

Platform Diameter Transfer

Code No. Hex N-Hex

DETIM40H DETIM40N

Regular

Hex N-Hex Hex N-Hex

DETIR50H DETIR50N DETIR60H DETIR60N

Wide

Hex N-Hex

DETIW60H DETIW60N

Mini

Hex

N-Hex

Transfer Lab Analog

Cemented Abutment

Platform Diameter

Hex

Cuff: 1, 2, 3, 4mm N-Hex

Mini

DELAM

Regular

DELAR

Wide

DELAW

Type Cuff Length

Code No. Mini DECAM416H DECAM426H DECAM436H DECAM446H

Regular DECAR516H DECAR616H DECAR526H DECAR626H DECAR536H DECAR636H DECAR546H DECAR646H

Wide DECAW616H DECAW626H DECAW636H DECAW646H

8mm

DECAM418H DECAM428H DECAM438H DECAM448H

DECAR518H DECAR528H DECAR538H DECAR548H

DECAR618H DECAR628H DECAR638H DECAR648H

DECAW618H DECAW628H DECAW638H DECAW648H

N-Hex 1mm 2mm 3mm 4mm

6mm

DECAM416N DECAM426N DECAM436N DECAM446N

DECAR516N DECAR526N DECAR536N DECAR546N

DECAR616N DECAR626N DECAR636N DECAR646N

DECAW616N DECAW626N DECAW636N DECAW646N

1mm 2mm 3mm 4mm

8mm

DECAM418N DECAM428N DECAM438N DECAM448N

DECAR518N DECAR528N DECAR538N DECAR548N

DECAR618N DECAR628N DECAR638N DECAR648N

DECAW618N DECAW628N DECAW638N DECAW648N

Hex L

Code No.

1mm 2mm 3mm 4mm

6mm

1mm 2mm 3mm 4mm


Cemented Abutment System Angled Abutment

Cuff: 2, 4mm 15。

Type

Cuff

Length

15。

2mm 4mm

8mm

25。

2mm 4mm

8mm

Platform Diameter Mini DEAAM4215 DEAAM4415

Regular DEAAR5215 DEAAR6215 DEAAR5415 DEAAR6415

Wide DEAAW6215 DEAAW6415

DEAAM4225 DEAAM4425

DEAAR5225 DEAAR6225 DEAAR5425 DEAAR6425

DEAAW6225 DEAAW6425

25。

Gold UCLA

Type

Platform Diameter

Hex

Mini DEGUMH

Regular DEGURH

Wide DEGUWH

N-Hex

DEGUMN

DEGURN

DEGUWN

Hex

N-Hex

Plastic UCLA

Type

Platform Diameter

Hex

Mini DEPMH

Regular DEPRH

Wide DEPWH

N-Hex

DEPMN

DEPRN

DEPWN

Hex

N-Hex

76 | 77

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for e-Clean

Estheticone System

Hex

N-Hex

Hex

Gold Cylinder

N-Hex

Plastic Cylinder

Lab Analog

Impression Coping(Transfer)

Impression Coping(Pick-up)

Estheticone Driver

Estheticone Abut.

Healing Cap

Cover Screw

Healing Abutment

Mount

e-Clean

1.2 Hex Driver


Estheticone Abutment System Estheticone Abutment

Platform Diameter

Cuff

Code No.

Ø4.1

1mm 2mm 3mm 4mm

DEEA10 DEEA20 DEEA30 DEEA40

Ø5.1

1mm 2mm 3mm 4mm

DEWA10 DEWA20 DEWA30 DEWA40

Cuff:1, 2, 3, 4mm

Healing Cap

Impression Coping

Platform Diameter

Code No.

Ø4.1

DEEHC

Ø5.1

DEWHC

Platform Diameter Ø4.1

Type Pick-Up

Ø5.1

Code No.

Hex N-Hex

DEESIH DEESIN

Hex N-Hex

DEWSIH DEWSIN

Pick-Up Impression Coping

Platform Diameter

Type

Ø4.1

Transfer

Code No. DEETI DEWTI

Ø5.1

Transfer

78 | 79

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Lab Analog

Gold Cylinder

Hex

N-Hex

Platform Diameter

Code No.

Ø4.1

DEELA

Ø5.1

DEWLA

Platform Diameter

Type

Code No.

Ø4.1

Hex N-Hex

DEEGCH DEEGCN

Ø5.1

Hex N-Hex

DEWGCH DEWGCN


Estheticone Abutment System Plastic Cylinder

Platform Diameter

Type

Code No.

Ø4.1

Hex N-Hex

DEMPH DEMPN

Ø5.1

Hex N-Hex

DEWPH DEWPN

Hex

N-Hex

80 | 81

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Prosthetic Flow Diagrams for e-Clean

O-Ring System

O-Ring

O-Ring Retainer

O-Ring Lab Analog

O-Ring Abutment Driver

O-Ring Abutment

Healing Abutment

Cover Screw

Mount

e-Clean

1.2 Hex Driver


O-Ring Abutment System O-Ring Abutment

Cuff:2, 4mm

Abutment Diameter

Cuff

Code No.

Ø4.1

2mm 4mm

DEORRA20 DEORRA40

Ø5.1

2mm 4mm

DEORWA20 DEORWA40

Code No.

O-Ring Lab Analog

DOLA

Code No.

O-Ring Retainer

DOR

Code No.

O-Ring

ORING

82 | 83

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


I-Fix Post Type System Flow

Post Type Fixture 7㎜

- Suitable for narrow space in the maxillary and mandibular anterior teeth - One-body type design provides maximum strength for mastication

Implant Diameter

Collar

ø2.0 Length

- Post type Neck design Neck design helps to make fast healing time

Collar

Length

Code

2.0mm

10.0mm

DMPF2010S

2.0mm

13.0mm

DMPF2013S

2.0mm

16.0mm

DMPF2016S

4.0mm

10.0mm

DMPF2010L

4.0mm

13.0mm

DMPF2013L

4.0mm

16.0mm

DMPF2016L

Collar

Length

Code

2.0mm

10.0mm

DMPF2510S

2.0mm

13.0mm

DMPF2513S

2.0mm

16.0mm

DMPF2516S

4.0mm

10.0mm

DMPF2510L

4.0mm

13.0mm

DMPF2513L

4.0mm

16.0mm

DMPF2516L

Collar

Length

Code

2.0mm

10.0mm

DMPF3010S

2.0mm

13.0mm

DMPF3013S

2.0mm

16.0mm

DMPF3016S

4.0mm

10.0mm

DMPF3010L

4.0mm

13.0mm

DMPF3013L

4.0mm

16.0mm

DMPF3016L

ø2.0

7㎜

Implant Diameter Collar

ø2.5 Length

ø2.5

7㎜

Implant Diameter

Collar

Lab Analog Code

ø3.0 Length

DMPL

ø3.0


I-Fix O-Ring Type System Flow

O-Ring Type Fixture 2.7㎜

Implant Diameter

2㎜

- Suitable for the edentulous patients Collar

- Creating fast and simple temporary prosthesis Length

ø2.0

Collar

Length

Code

1.5mm

10.0mm

DMOF2010S

1.5mm

13.0mm

DMOF2013S

1.5mm

16.0mm

DMOF2016S

3.5mm

10.0mm

DMOF2010L

3.5mm

13.0mm

DMOF2013L

3.5mm

16.0mm

DMOF2016L

Collar

Length

Code

1.5mm

10.0mm

DMOF2510S

1.5mm

13.0mm

DMOF2513S

1.5mm

16.0mm

DMOF2516S

3.5mm

10.0mm

DMOF2510L

3.5mm

13.0mm

DMOF2513L

3.5mm

16.0mm

DMOF2516L

Collar

Length

Code

1.5mm

10.0mm

DMOF3010S

1.5mm

13.0mm

DMOF3013S

1.5mm

16.0mm

DMOF3016S

3.5mm

10.0mm

DMOF3010L

3.5mm

13.0mm

DMOF3013L

3.5mm

16.0mm

DMOF3016L

ø2.0

2.7㎜

Implant Diameter

2㎜ Collar

Length

ø2.5

Lab Analog Code ø2.5

DMOL

Cap 2.7㎜

Code

Implant Diameter

2㎜

DOC

Collar

O-ring

Length

Code ORING

ø3.0

ø3.0

84 | 85

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


I-Fix Angled Type System Flow

Angled Type Fixture - Specialized 2 pieces-design reinforce safe fixation

Implant Diameter Collar

- Abutments are divided into Cemented and Angled for various cases and placement direction - Take fast, convenient impressions with 2 types of impression coping in narrow space

Collar

Length

Code

1.3mm

10.0mm

DMAF2010S

1.3mm

13.0mm

DMAF2013S

1.3mm

16.0mm

DMAF2016S

3.3mm

10.0mm

DMAF2010L

3.3mm

13.0mm

DMAF2013L

3.3mm

16.0mm

DMAF2016L

Collar

Length

Code

1.3mm

10.0mm

DMAF2510S

1.3mm

13.0mm

DMAF2513S

1.3mm

16.0mm

DMAF2516S

3.3mm

10.0mm

DMAF2510L

3.3mm

13.0mm

DMAF2513L

3.3mm

16.0mm

DMAF2516L

Collar

Length

Code

1.3mm

10.0mm

DMAF3010S

1.3mm

13.0mm

DMAF3013S

1.3mm

16.0mm

DMAF3016S

3.3mm

10.0mm

DMAF3010L

3.3mm

13.0mm

DMAF3013L

3.3mm

16.0mm

DMAF3016L

1㎜

ø2.0 Length

ø2.0

Implant Diameter

1㎜ Collar

ø2.5 Length

ø2.5

Implant Diameter 1㎜ Collar

ø3.0 Length

ø3.0


Lab Analog Code DMAL

15°

Angled Abutment (15° ) 0.7㎜

Abutment Diameter

Cuff

Length

Code

ø4

0.7mm

9.1mm

DMAA15

Double Hex

Cemented Abutment 0.7㎜ Hex

Abutment Diameter

Cuff

Length

Code

ø4

0.7mm

8.3mm

DMCAH

ø4

0.7mm

8.3mm

DMCAN

Non-Hex

Free Abutment Abutment Diameter

Cuff

Length

Code

ø4

0.7mm

11.3mm

DMFAH

ø4

0.7mm

11.3mm

DMFAN

0.7㎜ Hex

Non-Hex

Angled Mount Adapter Detail

Code

0.9 Hex Driver 사용

DMAMA

Impression coping

Pick-up

L

18㎜

12㎜

86 | 87

ⅠGuide

Length

Code

12mm

DMIC12

18mm

DMIC18

23mm

DMIC23

23㎜

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


99% Satisfaction. The remaining 1 % is for new techniques to be developed soon. Cleanlant System absolutely improves the defects of the existing products, has superior compatibility, accurate No-mount system and strong initial fixation strength and many more.


V

Cleanlant Surgical KIT


Features of Surgical Tool 1) Cleanlant Surgical Kit

Tapered Combined KIT

Straight Combined KIT

SAVE KIT

I-Fix KIT

2) Stopper drill

ø2.2 Twist drill

ø2.8 Twist drill

ø3.5 Twist drill

ø3.5 Straight Twist drill

ø3.7 Twist drill

ø4.1 Twist drill

ø4.2 Straight Twist drill

ø4.3 Twist drill

ø4.8 Twist drill

ø5.1 Twist drill

The Special Features of Safe Stopper Twist Drill 1. Safe Drill Stopper The Stopper of 3-Blade Safe Tapered Twist Drill is used to prevent nerves injury from excessive drilling. 2. 3-Blade Safe Twist Drill 3-blade Safe Tapered Twist drill, produced only by DENTIS Company, has excellent cutting capability to prevent bone heating and drilling can operated at a low speed. It could easily extract bone chips and is stable for surgical operation. 3. Tapered Design 3-blade Safe Tapered Twist Drill, produced only by DENTIS Company, can be used at a low drilling speed to taper into the bone and gives accurate surgical operation. 3) Multi stopper drill - Stopper

2㎜

3㎜

4㎜

Basically 2mm Rotary Stopper is fitted. Attaching and detaching is smooth and easy. When stopper makes contact with the bone, it stops rotating, hence does not damage the bone.

-Drill Long

short ø5.5-S Drill

8㎜ 7㎜ 6㎜

2㎜ stopper

8㎜ 7㎜ 6㎜

3㎜ stopper

7㎜

4㎜ stopper

6㎜

ø5.5-L Drill

2㎜ stopper

12㎜ 10㎜

Basically Rotating Stopper is fitted. Short drill is 10mm and Long drill is 14mm. If the stopper is equiped, the short drill can be adjusted as 6mm to 8mm and the long drill can be adjusted as 10mm to 12mm. It is convenient and possible to use without the stopper depending on the shape of the bone during surgery.

12㎜ 10㎜

4㎜ stopper

10㎜


4) Excellent Enhancement of W/C Coating Treatment Tungsten Carbide Coating is 4 times stronger and easier to drill than other drills and minimizes bone heating during drilling.

5)‘Convenient’Depth Gauge It is easy to check the space between fixtures and the depth of Mesiodistal and the location of buccolongual during initial drilling.

6)‘Convenient’No-mount Driver DENTIS No-mount Driver can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects by the surrounding teeth.

7) Multiple Tap Drill It is manufactured for Machine and Hand use, using an adaptor that can be attached to 3 kinds of drivers(Rachet Long, Rachet Short for Machine use and Ratchet for Hand use)

8) Torque Rachet Convenient fittings and accurate torque value are measured in units 15NCm, 25NCm, and 35NCm. It is be managed efficiently by simply disassembling it and can be easily cleaned inside after operation.

90 | 91

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Combined KIT


Drilling Sequence

/ Depending on the Bone Condition

Ø3.7 Fixture D4 Bone Point drill →Ø2.2 drill →Ø 2.8 drill →Ø3.7 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø 2.8 drill →Ø3.7 drill →Ø3.7 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø 3.7 drill →Ø3.7 tap drill → Ø3.7 fixture Ø4.3 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.3 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.3 tap drill →Ø4.3 fixture Ø4.8 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill → Ø4.8 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 drill →Ø4.8 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.7 drill →Ø4.3 drill →Ø4.8 drill →Ø4.8 tap drill →Ø4.8 fixture

Drilling Sequence Depending on the Bone Condition Ø3.5 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø3.5 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø3.5 tap drill → Ø3.5 fixture Ø4.1 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 drill →Ø4.1 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 drill →Ø4.1 tap drill → Ø4.1 fixture Ø5.1 Fixture D4 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 drill →Ø5.1 fixture D2-3 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 drill → 5.1 drill → Ø5.1 fixture D1 Bone Point drill →Ø2.2 drill →Ø2.8 drill →Ø3.5 drill →Ø4.1 drill →Ø5.1 drill →Ø5.1 tap drill →Ø5.1 fixture

92 | 93

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Straight KIT


/

Drilling Sequence

Depending on the Bone Condition Ø4.1 Fixtue D4 Point drill → Ø2.2 drill → Ø2.2/2.8 pilot drill → Ø2.8 drill → Ø4.1 fixture D2-3 Point drill → Ø2.2 drill → Ø2.2/2.8 pilot drill → Ø2.8 drill → Ø2.8/3.5 pilot drill → Ø3.5 straight drill → Ø4.1 fixture D1 Point drill → Ø2.2 drill → Ø2.2/2.8 pilot drill → Ø2.8 drill → Ø2.8/3.5 pilot drill → Ø3.5 straight drill → Ø4.1 tap drill → Ø4.1 fixture

D2-3

D4

D1

Ø4.8 Fixtue D4 Point drill → Ø2.2 drill → Ø2.2/2.8 pilot drill → Ø2.8 drill → Ø2.8/3.5 pilot drill → Ø3.5 straight drill → Ø4.8 fixture D2-3 Point drill → Ø2.2 drill → Ø2.2/2.8 pilot drill → Ø2.8 drill → Ø2.8/3.5 pilot drill → Ø3.5 straight drill → Ø3.5/4.2 pilot drill → Ø4.2 straight drill → Ø4.8 fixture D1 Point drill → Ø2.2 drill → Ø2.2/2.8 pilot drill → Ø2.8 drill → Ø2.8/3.5 pilot drill → Ø3.5 straight drill → Ø3.5/4.2 pilot drill → Ø4.2 straight drill → Ø4.8 tap drill → Ø4.8 fixture

D2-3

D4

94 | 95

ⅠGuide

Ⅱ Technique

D1

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


KIT 5.5, 6.0 Fixture [Exclusive use] Surgical Kit Internal/ Submerged [Multiple Use] Stopper Drill

Drill Basically Rotating Stopper is fitted. Short drill is 8 mm and Long drill is 12mm. If the stopper is equiped, the short drill can be adjusted as 6mm to 8mm and the long drill can be adjusted as 10mm to 12mm. It is convenient and possible to use without the stopper depending on the shape of the bone during surgery. Stopper Basically 2mm Rotary Stopper is fitted. Attaching and detaching is smooth and easy. When stopper makes contact with the bone, it stops rotating, hence reduce damage to the alveolar bone. No-mount System No-mount Driver can immediately ensure a path during surgery and reduces operation time and attains accurate operation with no effects by the surrounding teeth.

Drilling Sequence Ø5.5 Fixture D4 Bone Point drill → Ø2.2 drill → Ø2.8 drill → Ø3.7 drill → Ø4.3 drill → Ø4.8 drill → Ø5.5 fixture D2-3 Bone Point drill → Ø2.2 drill → Ø2.8 drill → Ø3.7 drill → Ø4.3 drill → Ø4.8 drill → Ø5.5 drill → Ø5.5 fixture D1 Bone Point drill → Ø2.2 drill → Ø2.8 drill → Ø3.7 drill → Ø4.3 drill → Ø4.8 drill → Ø5.5 drill → Ø5.5 tap drill → Ø5.5 fixture Ø6.0 Fixture D4 Bone Point drill → Ø2.2 drill → Ø2.8 drill → Ø3.7 drill → Ø4.3 drill → Ø4.8 drill → Ø5.5 drill → Ø6.0 fixture D2-3 Bone Point drill → Ø2.2 drill → Ø2.8 drill → Ø3.7 drill → Ø4.3 drill → Ø4.8 drill → Ø5.5 drill → Ø6.0 drill → Ø6.0 fixture D1 Bone Point drill → Ø2.2 drill → Ø2.8 drill → Ø3.7 drill → Ø4.3 drill → Ø4.8 drill → Ø5.5 drill → Ø6.0 drill → Ø6.0 tap drill → Ø6.0 fixture


KIT I-FIX Surgical Kit

Drilling Sequence ø2.0 Fixture Point drill → Ø1.3 straight drill → Ø2.0 fixture ø2.5 Fixture Point drill → Ø1.3 straight drill → Ø1.8 straight drill →Ø2.5 fixture ø3.0 Fixture Point drill → Ø1.3 straight drill → Ø1.8 straight drill → Ø2.3 straight drill →Ø3.0 fixture

96 | 97

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


The function of path guide during insertion of many fixtures Diagnosis of the length and size of dental prosthesis simultaneously during insertion

PROKIT, first in the world, developed for diagnosis or use in operation, consists of a system that can be used for getting dental impression for prosthesis during surgery, as it provides all kinds of abutments that can be used in i-Clean Fixture and s-Clean Fixture. It is easy to distinguish inside of the mouth or during operation due to color coding according to the shape and type. It can be also used in all kinds of dental autoclave just as other operating tools.


Surgical Tools Point drill Code

DPD

Round Bar Drill Code

DRB

Drill Extension Code

DDE

Ø2.2

10㎜

Parallel Pin 22.1㎜

2.1㎜

Code

DPP

10㎜

Ø2.8 Ø3.96

2.8㎜

Position Guide Code

DPG07

2.2㎜

98 | 99

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Depth gauge Diameter

Ø2.2

Ø2.8

Code

DDG22

DDG28

Straight twist drill

L

Diameter Length

Ø2.2

Ø2.8

Ø3.5

Ø4.2

8mm

DTD2208

DTD2808

DSTD3508

DSTD4208

10mm

DTD2210

DTD2810

DSTD3510

DSTD4210

12mm

DTD2212

DTD2812

DSTD3512

DSTD4212

14mm

DTD2214

DTD2814

DSTD3514

DSTD4214

L

Twist drill Diameter Length L

Ø3.5

Ø3.7

Ø4.1

Ø4.3

Ø4.8

Ø5.1

8mm

DTD3508 DTD3708 DTD4108 DTD4308 DTD4808 DTD5108

10mm

DTD3510 DTD3710 DTD4110 DTD4310 DTD4810 DTD5110

12mm

DTD3512 DTD3712 DTD4112 DTD4312 DTD4812 DTD5112

14mm

DTD3514 DTD3714 DTD4114 DTD4314 DTD4814 DTD5114

L

Pilot Drill 8.9㎜

Ø2.2 Ø2.8

Ø3.5

Ø2.8 Ø3.5

Ø4.2

Diameter

Ø2.8

Ø3.5

Ø4.2

Code

DSPD28

DSPD35

DSPD42


Tap Drill

14㎜ 12㎜ 10㎜

0.5㎜

Ø4.1

8㎜

Diameter

Ø3.5

Ø3.7

Ø4.1

Ø4.3

Ø4.8

Ø5.1

Code

DTM35

DTM37

DTR41

DTR43

DTW48

DTW51

Straight tap drill Diameter

Ø4.1

Ø4.8

Code

DSTR41

DSTW48

Ø4.8

i-Clean No-mount driver Code

DMMDI

i-Clean Ratchet driver Type

Short

Long

Code

DRMDIS

DRMDIL

s-Clean No-mount driver Code

DMMDS

s-Clean Ratchet driver Type

Short

Long

Code

DRMDSS

DRMDSL

100 | 101

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


Mount driver for machine Type

e-Clean 3.5 / Tap drill

Code

DMHD24

e-Clean 4.1 /

5.1

DMHD30

Mount driver for ratchet Type Code

e-Clean 3.5 / Tap drill

e-Clean 4.1 /

5.1

Short

Long

Short

Long

DRHDS24

DRHDL24

DRHDS30

DRHDL30

Hex driver Type

0.9 Hex

Code

DRD09

1.2 Hex

1.25 Hex

Short

Long

Short

Long

DRD12S

DRD12L

DRD125S

DRD125L

Solid driver Code

DSAD

Excellent Driver Code

DESAD

Octa driver Type

Short

Long

Code

DOADS

DOADL


Estheticone driver Type

4.1

5.1

Code

DEED

DEWD

Type

Short

Long

Code

DORADS

DORADL

O-ring driver

Torque ratchet Code

DTR

Ratchet wrench Code

DRW

102 | 103

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


SAVE Surgical Tools

SAVE twist drill 8㎜ 7㎜ 6㎜

8㎜ 7㎜ 6㎜

12㎜ 10㎜

Length

Diameter 5.5

6.0

8mm

DSD5508

DSD6008

12mm

DSD5512

DSD6012

5.5

6.0

12㎜ 10㎜

Tap drill Diameter Code

DTW55

DTW60


I-Fix Surgical Tools

2㎜ 16㎜ 13㎜

2㎜

10㎜

Straight twist drill Diameter

Ø1.3

Ø1.8

Ø2.3

Code

DMD13

DMD18

DMD23

Mini machine driver L

2㎜ 2㎜

Type

Length

Code

Short

26mm

DMMS

Long

31mm

DMML

Type

Length

Code

Short

26mm

DMRS

Long

31mm

DMRL

Mini ratchet driver

L 2㎜ 2㎜

ø1.8

10㎜

Depth gauge

16㎜ 13㎜

Code

DMDP

10㎜

ø1.3

104 | 105

ⅠGuide

Ⅱ Technique

Ⅲ Recommendation Ⅳ Construction

Ⅴ Surgical Kit


We actualize impressing our customers through elaborate service with devotion and high-tech engineering skills made with passion to achieve the best products.

Products would not be made if they are not of the best quality.


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.