Nabertherm - Técnologia dos processos térmicos

Page 88

Gas Feed Systems Gas Feed Fitting with Solenoid Valve  Designed like the manual gas feed fitting described above, however with an additional solenoid valve mounted on the furnace, controlled using the controller "Extra" function.  Connection: screw connection for bottle  Exit: 3/8 inch hose connection  200 bar intake pressure, 4 bar outlet pressure  Incl. 4 m 3/8 inch connecting hose  Available only in combination with furnace or switchgear For N 7 - N 17/HR Article no.

For N 21 - N 641/13, N 30/45HA + N 500/85HA

Flow rate l/min 631000376 Ar 0 - 16 631000377 N2 0 - 16 631000378 Forming gas 95/5 0 - 16 *Article no. for Spain, France and Portugal on request

Automatic gas feed system for two flushing quantities

Type of gas

Article no.

Type of gas

631000379 631000380 631000381

Ar N2 Forming gas 95/5

Flow rate l/min 0 - 32 0 - 32 0 - 32

Automatic Gas Feed System for two different Flushing Quantities, e.g. high Volume Preflushing and low Volume for ongoing Operation Consisting of:  Switching system with 3-step switch for gas inlet Off/Manual/Automatic via "Extra" function of respective controller, timer for switching from large gas quantity to small gas quantity. Gas feed stops at when program quits  Automatic gas feed panel with pressure reducer, two adjustable flow meters and two solenoid valves, preinstalled conduit and wiring attached to furnace from the side on an assembly plate.  Connection: 3/8 inch hose connection  Exit: 3/8 inch hose connection  Max. 10 bar intake pressure, max. 300 mbar rear pressure  Incl. 5 m connection hose 3/8 inch  Available only in combination with furnace or switchgear Article no.

Type of gas

631000316 631000200 631000315

Ar N2 Forming gas 95/5

Flow rate l/min 4 - 80 4 - 80 4 - 80

Temperature Measurement in Protective Gas Systems The use of a thermometer with thermocouple is recommended for determining the exact heat treatment temperature in gas feed boxes or gas feed annealing bags with holder. The thermocouple is permanently mounted on the respective gas feed box or gas feed annealing bag holder. A simple manual temperature probe with LCD display or a temperature indicator with LED display and interface to documentation via the Nabertherm software can be supplied, mounted in a separate metal casing. Both are equipped with a two-pole plug unit for connecting to the thermocouple. The temperature can be determined in this way and, if necessary, readjusted on the controller. Upon request, the furnace can be operated by charge control with a thermocouple attached to the workpiece.

Thermostat (manual device)

16

Article no. 402000057 542100028 V000800 V000801

Description Temperature indicator with digital display, 230 V 1/N connection, in metal casing Temperature indicator with digital display, battery-operated, manual device Connecting cable between heat treatment with charge thermocouple and Article no. 402000057, 3 m Connecting cable between heat treatment with charge thermocouple and Article no. 542100028, 3 m


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.