Camera interfaces
Optocoupler input (internal)
IF
0 IC Optocoupler output (external) 100% 90%
t
10% 0 td td tr ton (= td + tr)
tr
ts
ton delay time rise time turn-on time
toff
tf
t
ts storage time tf fall time toff (= ts + tf) turn-off time
Figure 70: Manta output switching times For all Manta models: Parameter and value td 1 μs tr 1 μs ton = td + tr 2 μs
ts 26 μs tf 21 μs toff = ts + tf 47 μs (toff can deviate by 5 μs)
Table 33: Parameters for Manta Test conditions Output: external 2.4 k resistor to GND, power input for output ports set to 12 V. Note
Higher external values increase the times in the table above.
Manta Technical Manual V7.0.1
109