eljintek

Page 1



ELJINTEK, INC. ◎Adapter Information Technology Equipment Single Output

2013/02/25

6W Wall mount (Energy star V) 15W Wall mount (Energy star V) 15W Desktop (Energy star V) 18W Wall mount (Energy star V) 18W Wall mount Interchangeable (Energy star V) 18W Desktop (Energy star V) 30W Desktop (Energy star V) 40W Desktop (Energy star V) 50W Desktop (Energy star V) 60~65W Desktop (Energy star V) 66W Desktop 70W Desktop (Energy star V)

GPSU06 / P2 GPSU15 / P4 GPSU15 / P6 GPSU18 / P8 GPSU18 / P10 GPSU18 / P12 GPSU30 / P14 GPSU40 / P16 A2-50 / P18 A2-60; A2-65 / P20 PSU66 / P22 GPSU70 / P24

◎Adapter Information Technology Equipment Dual or Triple Output 25W Desktop 50W Desktop

PSU25 / P26 PSU50 / P28

◎ Adapter Medical Equipment 6W Wall mount (Energy star V) 18W Wall mount (Energy star V) 18W Wall mount interchangeable (Energy star V) 18W Desktop (Energy star V) 30W Desktop 50W Desktop 70W Desktop (Energy star V)

GMPU06 / P30 GMPU18 / P32 GMPU18 / P34 GMPU18 / P36 MPU30 / P38 MPU50 / P40 GMPU70 / P42

◎ Battery Charger 6W Wall mount 15W Wall mount 15W Desktop 30W Desktop ◎ OPEN FRAME 15W (Energy star V) 30W (Energy star V) 40W (Energy star V)

GPSU06X-CC / P44 GPSU15X-CC / P46 GPSU15X-CC / P48 GPSU30X-CC / P50

GPSO15 / P52 GPSO30 / P54 GPSO40 / 56


◎ LED LEO15W LEO40W LE41 LE61

LEO15 / P58 LEO40 / P60 LE41 / P62 LE61 / P64

◎ USB Charger UL / 5W USB Charger (Energy star V) TUV / 5W USB Charger (Energy star V) UL / 10.5W USB Charger (Energy star V) TUV / 10.5W USB Charger (Energy star V)

GUSB05 / P66 GUSB05E / P67 GUSB12 / P68 GUSB12E / P69

◎ In Car DC to DC USB 5V 500mA USB

PSD03 / P70

◎In Car DC to DC Isolation 18W (Input:36~72VDC)

PSD18 / P71

18W (Input:11~26VDC) 36W (Input:11~26VDC)

PSD25 / P72 PSD40 / P73

◎ In Car DC to DC Non Isolation 8W (Input:11~15VDC) 25W (Input:11~26VDC) 40W (Input:11~26VDC) 60W (Input:11~15VDC)

PSD12 / P74 PSD25 / P75 PSD40 / P76 PSD60 / P77

◎ In Car Power Extension Adapter With USB 12W-24VDC Dual standard USB connector 12VDC standard USB connector 12VDC Dual standard USB connector

◎CONNECTOR (DC PLUG)LIST

EJ13-123 / P78 EJ13-149 / P79 EJ13-175 / P80

P.81


GPSU06 6W Wall mount series

(ENERGY STAR V)

Plug-in power supply Features: z Universal input voltage z No load power consumption: <0.3W z Meet ENERGY STAR V for 5~48VDC z Single output z Pass LPS z Optional output connectors z Short circuit protection z High efficiency & reliability z Outputs are available at request z Compact package z One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

GPSU06 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

0.2A Max.

Leakage current

0.25mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating Chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection

Yes. Hiccup mode ; Auto- recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at+40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up/Hold up/Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chart

Insulation resistance

50Mohm minimum from input to output

Inrush current

30 AMPS@115 VAC;60AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11 (B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003

Safety requirements

(A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1

Warranty

1year <2>


GPSU06 6W Wall mount series

(ENERGY STAR V)

X=U American type (FIG1) or E European type (FIG2) or S 3pin Australian type (FIG3) or SA 2pin Australian type (FIG4) or BS UK type (FIG5) Line

Load

Avg. EFF (%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

50

±1

±5.5

55

<0.3

50

±0.5

±5

68.19

<0.3

5

80

±0.5

±5

74

<0.3

7.5

Output

Output

Max .Output

Ripple(mV)

Voltage(VDC)

Current(A)

Power (W)

Max.

GPSU06X-0

3~5

1.33~0.80

4

GPSU06X-1

5~6

1.00~0.80

5

GPSU06X-1-1

6~8

1.00~0.75

6

Model name

No load Power Consumption(W)

Measured at the output of 3.3

GPSU06X-2

8~11

0.75~0.54

6

80

±0.5

±5

74

<0.3

9

GPSU06X-3

11~13

0.54~0.46

6

100

±0.5

±3

74

<0.3

12

GPSU06X-4

13~16

0.46~0.37

6

120

±0.5

±3

74

<0.3

15

GPSU06X-5

16~21

0.37~0.28

6

150

±0.5

±3

74

<0.3

18

GPSU06X-6

21~27

0.28~0.20

6

180

±0.5

±2

74

<0.3

24

GPSU06X-7

27~33

0.20~0.18

6

200

±0.5

±2

74

<0.3

28

GPSU06X-8

33~48

0.18~0.12

6

200

±0.5

±2

74

<0.3

48

Note: 1. Weight: Approx 70~100g 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard Output cable: 20AWG UL2468 6FT <3>


GPSU15 15W Wall mount series

(ENERGY STAR V)

Plug-in power supply Features: z z z z z z z z z z

z

Universal input voltage No load power consumption<0.3W Meet ENERGY STAR V for 5~48VDC Single output Pass LPS Optional output connectors Short circuit protection High efficiency & reliability Outputs are available at request Compact package One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

GPSU15 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

0.5A Max.

Leakage current

0.25mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating Chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection

Yes. Hiccup mode ; Auto-recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chat

Insulation resistance

50Mohm. minimum from input to output

Inrush current

40 AMPS@115 VAC ; 60AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11 (B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003

Safety requirements

(A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1

Warranty

1year <4>


GPSU15 15W Wall mount series

(ENERGY STAR V)

X=U American type (FIG1) or E European type (FIG2) or S 3pin Australian type (FIG3) or SA 2pin Australian type (FIG4) or BS UK type (FIG5) Max.

Line

Load

Avg. EFF (%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

50

±1

±6

55

<0.3

50

±0.5

±5

74.78

<0.3

5

12

80

±0.5

±5

78.3

<0.3

7.5

1.80~1.36

15

80

±0.5

±5

79.7

<0.3

9

1.36~1.15

15

80

±0.5

±3

79.7

<0.3

12

13~16

1.15~0.94

15

100

±0.5

±3

79.7

<0.3

15

16~21

0.94~0.72

15

120

±0.5

±3

79.7

<0.3

18

GPSU15X-6

21~27

0.72~0.55

15

150

±0.5

±2

80

<0.3

24

GPSU15X-7

27~33

0.55~0.45

15

240

±0.5

±2

80

<0.3

28

GPSU15X-8

33~48

0.45~0.31

15

240

±0.5

±2

81

<0.3

48

Output

Output

Voltage(VDC)

Current(A)

GPSU15X-0

3~5

2.44~1.44

7.3

GPSU15X-1

5~6

2.4~2.00

12

GPSU15X-1-1

6~8

2.00~1.50

GPSU15X-2

8~11

GPSU15X-3

11~13

GPSU15X-4 GPSU15X-5

Model name

Output Power (W)

Ripple(mV) Max.

Note: 1. Weight: Approx 70~100g 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard Output cable: 5~6V: 18AWG SPT-1 6FT 6~48V: 20AWG UL2468 6FT <5>

No load Power Consumption(W)

Measured at the output of 3.3


GPSU15 15W Desktop series

(ENERGY STAR V)

Desktop power supply Features: z z z z z z z z z z z

Universal input voltage No load power consumption: <0.3W Meet ENERGY STAR V for 5~48VDC Single output Pass LPS Optional output connectors Short circuit protection High efficiency & reliability Outputs are available at request Compact package One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

GPSU15 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

0.5A Max.

Leakage current

0.25mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating Chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection

Yes. Hiccup mode ; Auto- recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chart

Insulation resistance

50Mohn minimum from input to output

Inrush current

40 AMPS@115 VAC ; 60AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11 (B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003

Safety requirements

(A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1

Warranty

1year <6>


GPSU15 15W Desktop series

(ENERGY STAR V)

X =A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D MAINS CORD INPUT Max.

Line

Load

Avg. EFF(%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

50

±1

±6

55

<0.3

50

±0.5

±5

74.78

<0.3

5

80

±0.5

±5

78.3

<0.3

7.5

15

80

±0.5

±5

79.7

<0.3

9

15

80

±0.5

±3

79.7

<0.3

12

1.15~0.94

15

100

±0.5

±3

79.7

<0.3

15

0.94~0.72

15

120

±0.5

±3

79.7

<0.3

18

21~27

0.72~0.55

15

150

±0.5

±2

80

<0.3

24

GPSU15X-7

27~33

0.55~0.45

15

240

±0.5

±2

80

<0.3

28

GPSU15X-8

33~48

0.45~0.31

15

240

±0.5

±2

81

<0.3

48

Output

Output

Voltage(VDC)

Current(A)

GPSU15X-0

3~5

2.44~1.44

7.3

GPSU15X-1

5~6

2.40~2.00

12

GPSU15X-1-1

6~8

2.00~1.50

12

GPSU15X-2

8~11

1.80~1.36

GPSU15X-3

11~13

1.36~1.15

GPSU15X-4

13~16

GPSU15X-5

16~21

GPSU15X-6

Model name

Ripple(mV)

Output

Max.

Power (W)

No load Power Consumption(W)

Measured at the output of 3.3

Y=U American type or E European type Line

Load

Regulation

Regulation

(%)

(%)

±1

±6

50

±0.5

±5

12

80

±0.5

±5

1.80~1.36

15

80

±0.5

1.36~1.15

15

80

±0.5

13~16

1.15~0.94

15

100

16~21

0.94~0.72

15

120

GPSU15D-6-Y

21~27

0.72~0.55

15

GPSU15D-7-Y

27~33

0.55~0.45

GPSU15D-8-Y

33~48

0.45~0.31

Max.

Avg. EFF (%)

No load Power

Measured at

25,50,75,100% load

Consumption(W)

the output of

55

<0.3

3.3

74.78

<0.3

5

78.3

<0.3

7.5

±5

79.7

<0.3

9

±3

79.7

<0.3

12

±0.5

±3

79.7

<0.3

15

±0.5

±3

79.7

<0.3

18

150

±0.5

±2

80

<0.3

24

15

240

±0.5

±2

80

<0.3

28

15

240

±0.5

±2

81

<0.3

48

Ripple(mV)

Output

Output

Voltage(VDC)

Current(A)

GPSU15D-0-Y

3~5

2.44~1.44

7.3

50

GPSU15D-1- Y

5~6

2.40~2.00

12

GPSU15D-1-1-Y

6~8

2.00~1.50

GPSU15D-2-Y

8~11

GPSU15D-3-Y

11~13

GPSU15D-4-Y GPSU15D-5-Y

Model name

Output Power (W)

Max.

Note: 1. Weight: Approx 100~250g 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard Output cable: 5~6V: 18AWG SPT-1 6FT 6~48V: 20AWG UL2468 6FT <7>


GPSU18 18W Wall mount series Features: z z z z z z z z z

z

Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Low leakage current <0.1mA One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

GPSU18 series:

Input voltage

100~240VAC

Input frequency

47~63Hz

Input current

0.7A Max.

Leakage current

0.1mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery

Short circuit protection

Yes. Hiccup mode ; Auto-recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chat

Insulation resistance

50Mohm. minimum from input to output

Inrush current

50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:EN55022 / EN55024 Class B (B)FCC Part 15

Safety requirements

Reference Design to (A)ES60601-1 (B)EN60601-1 (C)IEC 60950-1 (D) J60950-1

Warranty

1 year <8>


GPSU18 18W Wall mount series F1G 1(UL) 31.8 12.7

F1G 2(TUV) 35.7 17.9

22

22 NAME PLATE

NAME PLATE

32

12

23.8

24

32 14

12 24 75.5

5

75.5 1.5

5

18.6

17.2

18.2

6 8.5

8.5 20

20

39

39

75.5

75.5

F1G 3(SA)

F1G 4(UK) NAME PLATE

22

6.3 39.8

7.9

1.6

48.8 NAME PLATE

12 24

32 120°

75.5

12 24

22.2

21.7 42 75.5

5 4

17.06

17.6

9.8

22

8

9.5

22.7

6.5 8.5

8.5 20

20 39

39

75.5

75.5 100% 100% 80%

70% 60%

60%

40% 20% 0

10 C 20 C 30 C 40 C 50 C

Ambient temperature( c) Derating

60

85 90 100

264

Typical static characteristics

X=U American type (FIG1) or E European type (FIG2) or SA 2pin Australian type (FIG3) or BS UK type (FIG4) Max.

Line

Load

Avg. EFF (%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

80

±1

±5

76.42

<0.3

5

80

±1

±5

79.20

<0.3

7.5

18.04

100

±1

±5

80.30

<0.3

9

Output

Output

Voltage(VDC)

Current(A)

GPSU18X-1

5~6

3.00–2.50

15

GPSU18X-1-1

6~8

2.50-1.87

15

GPSU18X-2

8~11

2.25-1.64

Model name

Ripple(mV)

Output Power (W)

Max.

No load Power Consumption(W)

Measured at the output of

GPSU18X-3

11~13

1.64-1.38

18.04

120

±1

±5

82.40

<0.1

12

GPSU18X-4

13~16

1.38-1.13

18.08

150

±1

±5

82.40

<0.1

15

GPSU18X-5

16~21

1.13-0.86

18.08

150

±1

±5

82.40

<0.1

18

GPSU18X-6

21~27

0.86-0.67

18.09

150

±1

±5

82.40

<0.1

24

GPSU18X-7

27~33

0.67-0.55

18.15

240

±1

±3

82.40

<0.1

28

GPSU18X-8

33~58

0.55-0.32

18.56

240

±1

±3

82.40

<0.1

48

Note: 1. Weight: Approx 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT 13~58V: 22WG / UL2468 / 6FT

<9>


GPSU18 18W Wall mount interchangeable series Features: z z z z z z z z z

z

Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Low leakage current <0.1mA One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

GPSU18 series:

Input voltage

100~240VAC

Input frequency

47~63Hz

Input current

0.7A Max.

Leakage current

0.1mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery

Short circuit protection

Yes. Hiccup mode ; Auto-recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chat

Insulation resistance

50Mohm. minimum from input to output

Inrush current

50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:EN55022 / EN55024 Class B (B)FCC Part 15

Safety requirements

Reference Design to (A)ES60601-1 (B)EN60601-1 (C)IEC 60950-1 (D) J60950-1

Warranty

1 year <10>


GPSU18 18W Wall mount series F1G 1(UL) 32

F1G 2(TUV) 35.3

22 NAME PLATE

NAME PLATE

OPEN

OPEN

39.1

24

PUSH

PUSH

24

LOCK

39.1 33 12.7

LOCK

22

5

35.3

5

80.5

80.5 19.2 17.2 18.1

6.7

5.7

15.5

15.5 40.7 40.7

F1G 4(UK)

F1G 3(SA) 35.3

NAME PLATE

49.4

OPEN

22.2

24 LOCK

PUSH

24

PUSH

NAME PLATE OPEN

41 39.1

22

22

LOCK

5 80.5

42.3

5

80.5

17

22.8

17.6

8.7

8.2

15.5

15.5

40.7

40.7

PUSH LOCK

LOCK

OPEN

OPEN

100%

PUSH

(UL)

100%

(TUV)

80%

70% 60%

60%

40% PUSH

LOCK

20%

OPEN

OPEN

LOCK

PUSH

0

60

85 90 100

264

10 C 20 C 30 C 40 C 50 C

(SA)

Ambient temperature( c) Derating

(UK)

Typical static characteristics

X=U American type (FIG1) or E European type (FIG2) or SA 2pin Australian type (FIG3) or BS UK type (FIG4) Max.

Line

Load

Avg. EFF (%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

80

±1

±5

76.42

<0.3

5

80

±1

±5

79.20

<0.3

7.5

18.04

100

±1

±5

80.30

<0.3

9

Output

Output

Voltage(VDC)

Current(A)

GPSU18X-1

5~6

3.00–2.50

15

GPSU18X-1-1

6~8

2.50-1.87

15

GPSU18X-2

8~11

2.25-1.64

Model name

Ripple(mV)

Output Power (W)

Max.

No load Power Consumption(W)

Measured at the output of

GPSU18X-3

11~13

1.64-1.38

18.04

120

±1

±5

82.40

<0.1

12

GPSU18X-4

13~16

1.38-1.13

18.08

150

±1

±5

82.40

<0.1

15

GPSU18X-5

16~21

1.13-0.86

18.08

150

±1

±5

82.40

<0.1

18

GPSU18X-6

21~27

0.86-0.67

18.09

150

±1

±5

82.40

<0.1

24

GPSU18X-7

27~33

0.67-0.55

18.15

240

±1

±3

82.40

<0.1

28

GPSU18X-8

33~58

0.55-0.32

18.56

240

±1

±3

82.40

<0.1

48

Note: 1. Weight: Approx 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT 13~58V: 22WG / UL2468 / 6FT

<11>


GPSU18 18W Desktop series Features: z z z z z z z z z

z

Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Low leakage current <0.1mA One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

GPSU18 series:

Input voltage

100~240VAC

Input frequency

47~63Hz

Input current

0.7A Max.

Leakage current

0.1mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery

Short circuit protection

Yes. Hiccup mode ; Auto-recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chat

Insulation resistance

50Mohm. minimum from input to output

Inrush current

50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:EN55022 / EN55024 Class B (B)FCC Part 15

Safety requirements

Reference Design to (A)ES60601-1 (B)EN60601-1 (C)IEC 60950-1 (D) J60950-1

Warranty

1 year <12>


GPSU18 18W Wall mount series

58.5

58.5

32.8

32.8

29.25

FIG 1 100

58.5

FIG 2 58.5

FIG 3 X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D MAINS CORD INPUT Max.

Line

Load

Avg. EFF (%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

80

±1

±5

76.42

<0.3

5

80

±1

±5

79.20

<0.3

7.5

18.04

100

±1

±5

80.30

<0.3

9

Output

Output

Voltage(VDC)

Current(A)

GPSU18X-1

5~6

3.00–2.50

15

GPSU18X-1-1

6~8

2.50-1.87

15

GPSU18X-2

8~11

2.25-1.64

Model name

Ripple(mV)

Output Power (W)

Max.

No load Power Consumption(W)

Measured at the output of

GPSU18X-3

11~13

1.64-1.38

18.04

120

±1

±5

82.40

<0.1

12

GPSU18X-4

13~16

1.38-1.13

18.08

150

±1

±5

82.40

<0.1

15

GPSU18X-5

16~21

1.13-0.86

18.08

150

±1

±5

82.40

<0.1

18

GPSU18X-6

21~27

0.86-0.67

18.09

150

±1

±5

82.40

<0.1

24

GPSU18X-7

27~33

0.67-0.55

18.15

240

±1

±3

82.40

<0.1

28

GPSU18X-8

33~58

0.55-0.32

18.56

240

±1

±3

82.40

<0.1

48

Note: 1. Weight: Approx 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT 13~58V: 22WG / UL2468 / 6FT

<13>


GPSU30 30W Desktop series

(ENERGY STAR V)

Desktop power supply Features: z Universal input voltage z No load power consumption<0.3W z Vout above 9V meet ENERGY STAR V z Single output z Pass LPS for 8~50V output z Optional output connectors z Short circuit protection z Over voltage protection z Over current protection z One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection Short circuit protection Temperature coefficient Transient response Operating temperature Storage temperature Relative humidity Derating Avg. Efficiency Setup up / Hold up / Rise time Line regulation Load regulation Insulation resistance Inrush current Withstand voltage Mean time between failure EMI requirements

Safety requirements Warranty

GPSU30 series: 100~240VAC 50~60Hz 0.7A Max. Class1:3.5mA/Class2:0.25mA Max.@240VAC/50Hz See rating chart See rating chart See rating chart See rating chart Yes. Protected by Zener diode. Rated output voltage 110~140% Yes. Hiccup mode; Auto-recovery. Rated output current>110% Yes. Hiccup mode; Auto-recovery. All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change. 0℃~+40℃. See derating curve -40℃~+85℃ 5% to 95% non-condensing Derated from 100% at + 40℃ linearly to 70% at 50℃ See rating chart Typical:3000ms/ 10ms/50ms at full load ±1% maximum for any input voltage change between input voltage range Typical±5% variations from minimum to maximum output current. Or see rating chart 50Mohm minimum from input to output 65AMPS@115 VAC ; 95AMPS @ 230VAC at 25℃ cold start 4242VDC from input to output 100,000 hours minimum at full load at 25℃ ambient (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11 (B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 (C)VCCI:J55022(H14)V-3 / 06.04 and V-4/06.04 (A)UL60950-1; CSA C22.2 (B) EN60950-1;IEC60950-1 (C) J60950 1year <14>


GPSU30 30W Desktop series

(ENERGY STAR V)

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D=MAINS CORD INPUT Model name

Output

Output

Voltage(VDC)

Current(A)

Max. Output Power (W)

Ripple(mV) Max.

Line

Load

Avg. EFF (%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

No load Power

Measured at the

Consumption(W)

output of

3.3

*GPSU30X-0

3~5

5

15~25

50

±0.5

8(Note1)

64

<0.3

*GPSU30X-1

5~6

5.00~4.17

25

50

±0.5

8(Note1)

70

<0.3

5

*GPSU30X-1-1

6~8

4.15~3.13

25

80

±0.5

±5

76

<0.3

7.5

GPSU30X-2

8~11

3.71~2.73

30

80

±0.5

±5

83.49

<0.3

9

GPSU30X-3

11~13

2.70~2.31

30

120

±0.5

±5

83.49

<0.3

12

GPSU30X-4

13~16

2.29~1.88

30

140

±0.5

±3

83.49

<0.3

15

GPSU30X-5

16~21

1.86~1.43

30

140

±0.5

±3

84

<0.3

18

GPSU30X-6

21~27

1.43~1.12

30

150

±0.5

±3

84

<0.3

24

GPSU30X-7

27~33

1.12~0.91

30

240

±0.5

±2

84

<0.3

28

GPSU30X-8

33~50

0.91~0.61

30.5

240

±0.5

±2

84

<0.3

48

Y= U1 3Pin American type AC power cord (with FG) or U 2Pin American type AC power cord or E European type AC power cord Model name

Output

Output

Voltage(VDC)

Current(A)

Max. Output Power (W)

Ripple(mV) Max.

Line

Load

Avg. EFF (%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

No load Power

Measured at the

Consumption(W)

output of

3.3

*GPSU30D-0-Y

3~5

5

15~25

50

±0.5

8(Note1)

64

<0.3

*GPSU30D-1-Y

5~6

5.00~4.17

25

50

±0.5

8(Note1)

70

<0.3

5

*GPSU30D-1-1-Y

6~8

4.15~3.13

25

80

±0.5

±5

76

<0.3

7.5

GPSU30D-2-Y

8~11

3.71~2.73

30

80

±0.5

±5

83.49

<0.3

9

GPSU30D-3-Y

11~13

2.70~2.31

30

120

±0.5

±5

83.49

<0.3

12

GPSU30D-4-Y

13~16

2.29~1.88

30

140

±0.5

±3

83.49

<0.3

15

GPSU30D-5-Y

16~21

1.86~1.43

30

140

±0.5

±3

84

<0.3

18

GPSU30D-6-Y

21~27

1.43~1.12

30

150

±0.5

±3

84

<0.3

24

GPSU30D-7-Y

27~33

1.12~0.91

30

240

±0.5

±2

84

<0.3

28

GPSU30D-8-Y

33~50

0.91~0.61

30.5

240

±0.5

±2

84

<0.3

48

*NO LPS SAFETY Note: (1) The load regulation c/be at ±5% with remote sensor (2) Weight: Approx300~400g (3) Optional output connectors (see page 81) (4) ENERGY STAR V Standard Output cable: 8~11V: 16AWG

SPT-2 4FT 11~50V: 18AWG SPT-1 6FT <15>


GPSU40 40W Desktop series

(ENERGY STAR V)

Desktop power supply Features: z Universal input voltage z No load power consumption<0.3W z Meet CEC(2008)/EISA z Meet ENERGY STAR V z Single output z Pass LPS for 11~50V output z Optional output connectors z Short circuit protection z Over voltage protection z Over current protection z One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection Short circuit protection Temperature coefficient Transient response Operating temperature Storage temperature Relative humidity Derating Avg. Efficiency Setup up / Hold up / Rise time Line regulation Load regulation Insulation resistance Inrush current Withstand voltage Mean time between failure EMI requirements

Safety requirements Warranty

GPSU40 series: 100~240VAC 50~60Hz 1A Max. Class1:3.5mA/Class2:0.25mA Max.@240VAC/50Hz See rating chart See rating chart See rating chart See rating chart Yes. Protected by Zener diode. Rated output voltage 110~140% Yes. Hiccup mode; Auto-recovery. Rated output current>110% Yes. Hiccup mode; Auto-recovery. All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change 0℃~+40℃. See derating curve -40℃~+85℃ 5% to 95% non-condensing Derated from 100% at + 40℃ linearly to 70% at 50℃ See rating chart Typical:1000ms/ 10ms/50ms at full load ±1% maximum for any input voltage change between input voltage range Typical ±5% variations from minimum to maximum output current. 50Mohm minimum from input to output 60AMPS@115 VAC ; 80AMPS @ 230VAC at 25℃ cold start 4242VDC from input to output 100,000 hours minimum at full load at 25℃ ambient (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11 (B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 (C)VCCI:J55022(H14)V-3 / 06.04 and V-4/06.04 (A)UL60950-1; CSA C22.2 (B) EN60950-1;IEC60950-1 (C) J60950 1year <16>


GPSU40 40W Desktop series

(ENERGY STAR V)

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D=MAINS CORD INPUT Max.

Line

Output

Ripple(mV)

Voltage(VDC)

Current(A)

Power

Max.

*GPSU40X-1

5~6

5.00~4.17

25

200

1

6

80.24

<0.3

5

*GPSU40X-1-1

6~8

5.00~3.75

30

200

1

6

83.49

<0.3

6

*GPSU40X-2

8~11

4.38~3.18

35

120

1

5

84.46

<0.3

9

(W)

Regulation (%)

Regulation (%)

25,50,75,100% load

No load Power

Measured

Output

Model name

Load

Avg. EFF (%)

Output

Consumption(W)

at the output of

GPSU40X-3

11~13

3.64~3.08

40

130

1

5

85.30

<0.3

12

GPSU40X-4

13~16

3.08~2.50

40

250

1

5

85.30

<0.3

15

GPSU40X-5

16~21

2.82~2.15

45

250

1

5

86.03

<0.3

19

GPSU40X-6

21~27

2.15~1.67

45

300

1

5

86.03

<0.3

24

GPSU40X-7

27~33

1.67~1.37

45

300

1

5

86.03

<0.3

30

GPSU40X-8

33~50

1.37~0.90

45

400

1

5

86.03

<0.3

48

Y= U1 3Pin American type AC power cord (with FG) or U 2Pin American type AC power cord or E European type AC power cord Max.

Line

Load

Avg. EFF (%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

Measured

Output

Output

Output

Ripple(mV)

Voltage(VDC)

Current(A)

Power

Max.

*GPSU40D-1-Y

5~6

5.00~4.17

25

200

1

6

80.24

<0.3

5

*GPSU40D-1-1-Y

6~8

5.00~3.75

30

200

1

6

83.49

<0.3

6

*GPSU40D-2-Y

8~11

4.38~3.18

35

120

1

5

84.46

<0.3

9

GPSU40D-3-Y

11~13

3.64~3.08

40

130

1

5

85.30

<0.3

12

GPSU40D-4-Y

13~16

3.08~2.50

40

250

1

5

85.30

<0.3

15

GPSU40D-5-Y

16~21

2.82~2.15

45

250

1

5

86.03

<0.3

19

GPSU40D-6-Y

21~27

2.15~1.67

45

300

1

5

86.03

<0.3

24

GPSU40D-7-Y

27~33

1.67~1.37

45

300

1

5

86.03

<0.3

30

GPSU40D-8-Y

33~50

1.37~0.90

45

400

1

5

86.03

<0.3

48

Model name

(W)

*NO LPS SAFETY Note: (1) Weight: Approx250~400g (2) Optional output connectors (see page 81) (3) ENERGY STAR V standard output cable: 5~11V : 16AWG SPT-1 4FT 11~50V: 18AWG SPT-1 6FT

↑

<17>

No load Power Consumption(W)

at the output of


A2-50 50W Desktop series

(ENERGY STAR V)

Desktop power supply Features: z Meet ENERGY STAR V z CE compliance z Over voltage protection installation z Short circuit protective installation z Over current protective optional z Compact size

SAFETY AGENCY APPROVALS:

Specifications:

A2-50 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

1.5A Max.

Leakage current

Class1:3.5mA/Class2:0.25mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes.

Over current protection

Yes. Auto-recovery

Short circuit protection

Yes. Auto-recovery

Temperature coefficient

Operating temperature

All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change 0℃~+40℃. See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg.Efficiency

87% min

Setup up/Hold - up/ Rise time

Typical:3000ms / 10ms / 50ms at full load

Line regulation

±2% maximum for any input voltage change between input voltage range

Load regulation

Typical ±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

100AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

40000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:Emission:EN55022; EN61000-3-2,3/ Immunity;IEC61000-4-2,3,4,5,6,11

Safety requirements

(A)EN60950-1; IEC60950-1

Warranty

1year

Transient response

<18>


A2-50

50W Desktop series

(ENERGY STAR V) UNIT: mm

33

56

100

INDICATOR LED

FIG 2(U)

1

1

33

33

1

FIG 1(V)

FIG 3(W)

X=V IEC-320-C14 (FIG1) or U IEC-320-C8 (FIG2) or W IEC-320-C6 (FIG3) Model name

Output Voltage(VDC)

Output Current(A)

Max. Output Power (W)

Ripple (mV) Max.

Line Regulation (%)

Load Regulation (%)

Avg. Eff (%) 25,50,75,100% load

No load Power Consumption(W)

A2-50S12R-X A2-50S12R-X A2-50S12R-X A2-50S12R-X A2-50S12R-X A2-50S12R-X A2-50S12R-X A2-50S12R-X A2-50S12R-X A2-50S12R-X A2-50S12R-X

12 12.5 13 13.5 14 14.5 15 15.5 16 16.5 17

4.16 4.0 3.84 3.70 3.57 3.44 3.33 3.22 3.12 3.03 2.94

50 50 50 50 50 50 50 50 50 50 50

250 250 250 250 250 250 250 250 250 250 250

±2 ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±2 ±2

±5 ±5 ±5 ±5 ±5 ±5 ±5 ±5 ±5 ±5 ±5

87 87 87 87 87 87 87 87 87 87 87

<0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5

X=V IEC-320-C14 (FIG1) or U IEC-320-C8 (FIG2) or W IEC-320-C6 (FIG3) Model name

Output Voltage(VDC)

Output Current(A)

Max. Output Power (W)

Ripple(mV) Max.

Line Regulation (%)

Load Regulation (%)

Avg. Eff (%) 25,50,75,100% load

No load Power Consumption(W)

A2-50S18R-X A2-50S18R-X A2-50S18R-X A2-50S18R-X A2-50S18R-X A2-50S18R-X A2-50S18R-X A2-50S18R-X A2-50S18R-X A2-50S18R-X A2-50S18R-X A2-50S18R-X A2-50S18R-X

18 18.5 19 19.5 20 20.5 21 21.5 22 22.5 23 23.5 24

2.77

50

250

±2

±5

87

<0.5

2.70

50

250

±2

±5

87

<0.5

2.63

50

250

±2

±5

87

<0.5

2.56

50

250

±2

±5

<0.5

2.50

50

250

±2

±5

2.43

50

250

±2

±5

2.38

50

250

±2

±5

2.32

50

250

±2

±5

2.27

50

250

±2

±5

2.22

50

250

±2

±5

2.17

50

250

±2

±5

2.12

50

250

±2

±5

2.08

50

250

±2

±5

87 87 87 87 87 87 87 87 87 87

Note: (1) Weight: Approx250g (2) Optional output connectors (see page 81) (3) ENERGY STAR V standard output cable: 18AWG / 4FT / SPT-1

<19>

<0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5


A2-60;A2-65 60~65W Desktop series

(ENERGY STAR V)

Desktop power supply Features: z Meet ENERGY STAR V z CE compliance z Over voltage protection installation z Short circuit protective installation z Over current protective optional z Compact size

SAFETY AGENCY APPROVALS

Specifications:

A2-60;A2-65 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

1.5A Max.

Leakage current

Class1:3.5mA/Class2:0.25mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes.

Over current protection

Yes. Auto-recovery

Short circuit protection

Yes. Auto-recovery

Temperature coefficient Transient response

All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃. See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg.Efficiency

87% min

Setup up/Hold up/ Rise time

Typical:3000ms / 10ms / 50ms at full load

Line regulation

±2% maximum for any input voltage change between input voltage range

Load regulation

Typical ±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum form input to output

Inrush current

100AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

40000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE : Emission:EN55022; EN61000-3-2,3 / Immunity; IEC61000-4-2,3,4,5,6,11

Safety requirements

(A)EN60950-1; IEC60950-1

Warranty

1year <20>


A2-60;A2-65 60~65W Desktop series

(ENERGY STAR V) UNIT: mm

33

FIG 2(U)

1

FIG 1(V)

1

1

56

33

33

100

FIG 3(W) INDICATOR LED

X=V IEC-320-C14 (FIG1) or U IEC-320-C8 (FIG2) or W IEC-320-C6 (FIG3) Output

Output

Max. Output

Ripple(mV)

Line Regulation

Load

Avg. EFF (%)

No load Power

Voltage(VDC)

Current(A)

Power (W)

Max.

(%)

Regulation (%)

25,50,75,100% load

Consumption(W)

A2-60S12R-X A2-60S12R-X A2-60S12R-X

12 12.5 13

5.0 4.80 4.61

60 60 60

250 250 250

±2 ±2 ±2

±5 ±5 ±5

87 87 87

<0.5 <0.5 <0.5

A2-60S12R-X

13.5

4.44

60

250

±2

±5

87

<0.5

A2-60S12R-X

14

4.28

60

250

±2

±5

87

<0.5

A2-60S12R-X

14.5

4.13

60

250

±2

±5

87

<0.5

A2-60S12R-X

15

4.0

60

250

±2

±5

87

<0.5

A2-60S12R-X

15.5

3.87

60

250

±2

±5

87

<0.5

A2-60S12R-X

16

250

±2

±5

87

<0.5

16.5

3.75 3.63

60

A2-60S12R-X

60

250

±2

±5

87

<0.5

A2-60S12R-X

17

3.52

60

250

±2

±5

87

<0.5

Model name

X=V IEC-320-C14 (FIG1) or U IEC-320-C8 (FIG2) or W IEC-320-C6 (FIG3) Model name

Output

Output

Max. Output

Ripple(mV)

Line Regulation

Load

Avg. EFF (%)

No load Power

Voltage(VDC)

Current(A)

Power (W)

Max.

(%)

Regulation (%)

25,50,75,100% load

Consumption(W)

A2-60S18R-X

18

3.33

60

300

±2

±5

87

<0.5

A2-60S18R-X

18.5

3.24

60

300

±2

±5

87

<0.5

A2-60S18R-X

19

3.15

60

300

±2

±5

87

<0.5

A2-60S18R-X

19.5

3.07

60

300

±2

±5

87

<0.5

A2-60S18R-X

20

3.0

60

300

±2

±5

87

<0.5

A2-60S18R-X

20.5

2.92

60

360

±2

±5

87

<0.5

A2-60S18R-X

21

2.85

60

360

±2

±5

87

<0.5

A2-60S18R-X

21.5

2.79

60

360

±2

±5

87

<0.5

A2-60S18R-X

22

2.72

60

360

±2

±5

87

<0.5

A2-60S18R-X

22.5

2.66

60

360

±2

±5

87

<0.5

A2-60S18R-X

23

2.60

60

360

±2

±5

87

<0.5

A2-60S18R-X

23.5

2.55

60

360

±2

±5

87

<0.5

A2-60S18R-X

24

2.50

60

360

±2

±5

87

<0.5

X=V IEC-320-C14 (FIG1) or U IEC-320-C8 (FIG2) or W IEC-320-C6 (FIG3) Model name

Output

Output

Max. Output

Ripple(mV)

Line Regulation

Load

Avg. EFF (%)

No load Power

Voltage(VDC)

Current(A)

Power (W)

Max.

(%)

Regulation (%)

25,50,75,100% load

Consumption(W)

A2-65S18R-X

18

3.61

65

300

±2

±5

87

<0.5

A2-65S18R-X

18.5

3.51

65

300

±2

±5

87

<0.5

A2-65S18R-X

19

3.42

65

300

±2

±5

87

<0.5

A2-65S18R-X

19.5

3.33

65

300

±2

±5

87

<0.5

A2-65S18R-X

20

3.25

65

300

±2

±5

87

<0.5

A2-65S18R-X

20.5

3.17

65

360

±2

±5

87

<0.5

A2-65S18R-X

21

3.09

65

360

±2

±5

87

<0.5

A2-65S18R-X

21.5

3.02

65

360

±2

±5

87

<0.5

A2-65S18R-X

22

2.95

65

360

±2

±5

87

<0.5

A2-65S18R-X

22.5

2.88

65

360

±2

±5

87

<0.5

A2-65S18R-X

23

2.82

65

360

±2

±5

87

<0.5

A2-65S18R-X

23.5

2.76

65

360

±2

±5

87

<0.5

A2-65S18R-X

24

2.70

65

360

±2

±5

87

<0.5

Note: (1) Weight: Approx250g (2) Optional output connectors (see page 81) (3) ENERGY STAR V standard output cable: 18AWG / 4FT / SPT-1

<21>


PSU66 66W Desktop series Desktop power supply Features: z Universal input voltage z Single output z Pass LPS for 13~48V output z Optional output connectors z High efficiency & reliability z Compact package z Over voltage protection z Over current protection z Optional input inlets z One year limited warranty

FIG 1

SAFETY AGENCY APPROVALS:

Specifications:

FIG 2

PSU66 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

1.5A Max.

Leakage current

3.5mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Provided on outputs set at 112~132% of its nominal output voltage

Over current protection

All outputs protected to short circuit conditions

Temperature coefficient Transient response

All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+30℃. See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 30℃ linearly to 70% at 50℃

Efficiency

See rating chart

Hold - up time

10msec minimum

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

15AMPS @ 115VAC or 30AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

50,000 hours minimum at full load at 25℃ ambient

EMI requirements

Meet CE standards

Safety requirements

Meets or exceeds :(A)UL60950-1(B) CSA C22.2 (C)TUV EN60950-1; IEC960

Warranty

1year <22>


PSU66 66W Desktop series

X=A IEC-320-C14 (FIG1) or C IEC-320-C6 (FIG2) Model name

*PSU60X-0 *PSU60X-1 *PSU60X-1-1 *PSU60X-2 *PSU60X-3 PSU60X-4 PSU60X-5 PSU60X-6 PSU60X-7 PSU60X-8

Max.

Line

Load

Regulation

Regulation

(%)

(%)

50

1

10

60

50

1

8

63

5

48

80

1

5

74

7.5

6.25~5.00

50

80

1

5

74

9

6.00~5.08

66

80

1

5

75

12

5.08~4.13

66

100

1

3

75

15

4.13~3.14

66

100

1

3

75

18

3.14~2.44

66

150

1

2

75

24

2.44~2.00

66

150

1

2

75

30

2.00~1.38

66

150

1

2

75

48

Output

Output

Voltage(VDC)

Current(A)

3~5 5~6 6~8 8~11 11~13 13~16 16~21 21~27 27~33 33~48

8.00~4.80

24

8.50~7.50

42.5

8.00~6.00

Output Power (W)

Ripple(mV) Max.

*NO LPS SAFETY Note: (1) Weight: Approx300~350g (2) Optional output connectors (see page 81) <23>

↑

Efficiency(%)(min)

Measured at the output of 3.3


GPSU70 70W Desktop series

(ENERGY STAR V)

Desktop power supply Features: z Universal input voltage z Meet ENERGY STAR V z Single output z Short circuit protection z Over voltage protection z Over current protection z Low leakage current z Output voltage 5~58VDC z One year limited warranty

FIG 1

SAFETY AGENCY APPROVALS:

Specifications:

FIG 2

GPSU70 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

1.8~0.8A Max.

Leakage current

<0.3mA

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes.<140% output voltage

Over current protection

Yes.>120% output current, Auto-recover

Short protection

Yes. Hiccup mode, Auto-recover

Temperature coefficient Transient response

All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

-20℃~+40℃.

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 30℃ linearly to 50% at 70℃

Avg.Efficiency

See rating chart

Hold - up time

8ms minimum

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

100AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)Meet CE :EN55022 CLASS B; EN55024; J55022(H22) (B)FCC PART 15 B

Safety requirements

(A)UL60950-1(B) EN60950-1(C)J60950-1(H22)

Warranty

1year <24>


GPSU70 70W Desktop series

(ENERGY STAR V)

X=A (C14 FIG1) or C (C6 FIG2) Model name

GPSU70X-1 GPSU70X-1-1 GPSU70X-2 GPSU70X-3 GPSU70X-4 GPSU70X-5 GPSU70X-6 GPSU70X-7 GPSU70X-8

Max.

Ripple(mV)

Line

Output

Voltage(VDC)

Current(A)

5~6 6~8 8~11 11~13 13~16 16~21 21~27 27~33 33~58

7.50~6.36

37.5

200

±1

±5

83.4

5

7.50~5.63

45

100

±1

±5

86.10

7.5

7.50~5.46

60

120

±1

±5

87

9

6.37~5.39

70

120

±1

±5

87

12

5.39~4.38

70

120

±1

±5

87

15

4.38~3.34

70

180

±1

±5

87

18

3.34~2.60

70

180

±1

±5

87

24

2.60~2.13

70

240

±1

±5

87

32

2.13~1.22

70

240

±1

±5

87

48

Output Power (W)

Max.

Regulation (%)

Note: (1) Weight: Approx370~375g (2) Optional output connectors (see page 81) (3) ENERGY STAR V standard output cable: 5~16V: UL1571 14AWG 4FT 17~58V: SPT-1 18AWG 6FT <25>

Avg. EFF (%)

Output

Load Regulation (%)

25,50,75,100% load

Measured at the output of


PSU25 25W Desktop series Desktop power supply Features: z Universal input voltage z Dual or triple outputs z Optional output connectors z High efficiency & reliability z Compact package z Over voltage protection z Over current protection z One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

PSU25 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

0.8A Max.

Leakage current

Class1:3.5mA/Class2:0.25mA Max.@240VAC/50Hz

Output voltage

See rating chart (±5% tolerance)

Output current

See rating chart

Output power range

25 watts Max.

Ripple

1% peak to peak maximum

Over voltage protection

Provided on outputs set at 112~132% of its nominal output voltage

Over current protection

All outputs protected to short circuit conditions

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 30℃ linearly to 70% at 50℃

Efficiency

65% minimum at full output

Hold - up time

10msec minimum

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

15AMPS@115 VAC or 30AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

50,000 hours minimum at full load at 25℃ ambient

EMI requirements

Meet CE standards

Safety requirements

Meets or exceeds(A)UL1950 (B) CSA C22.2 (C) TUV EN60950-1(D)IEC 950

Warranty

1year <26>


PSU25 25W Desktop series

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D=MAINS CORD INPUT

Model name PSU25X-13 PSU25X-14 PSU25X-16 PSU25X-16-1 PSU25X-13D PSU25X-14E PSU25X-13A

Output#1 Vnom lmax +5VDC 2.50A +5VDC 2.50A +5VDC 2.50A +5VDC 1.2A +5VDC 2.50A +5VDC 2.50A +5VDC 2.50A

Output#2 Vnom lmax +12VDC 1.00A +15VDC 0.80A +24VDC 0.50A +24VDC 0.80A +12VDC 0.80A +15VDC 0.50A +12VDC 0.80A

Output#3 Vnom lmax N/A N/A N/A N/A -12VDC 0.3A -15VDC 0.3A -5VDC 0.3A

Maximum Output Power 25W 25W 25W 25W 25W 25W 25W

Y=U American Type or E European Type

Output#1 Vnom lmax PSU25D-13-Y +5VDC 2.50A PSU25D-14-Y +5VDC 2.50A PSU25D-16-Y +5VDC 2.50A PSU25D-16-1-Y +5VDC 1.2A PSU25D-13D-Y +5VDC 2.50A PSU25D-14E-Y +5VDC 2.50A PSU25D-13A-Y +5VDC 2.50A Model name

Output#2 Vnom lmax +12VDC 1.00A +15VDC 0.80A +24VDC 0.50A +24VDC 0.80A +12VDC 0.80A +15VDC 0.50A +12VDC 0.80A

Note: (1) Weight: Approx 300~350g (2)Optional output connectors (see page 81)

<27> ↑

Output#3 Vnom lmax N/A N/A N/A N/A -12VDC 0.3A -15VDC 0.3A -5VDC 0.3A

Maximum Output Power 25W 25W 25W 25W 25W 25W 25W


PSU50 50W Desktop series Desktop power supply Features: z Universal input voltage z Dual or triple outputs z Optional input inlets z High efficiency & reliability z Compact package z Over voltage protection z Optional output connectors z Over current protection z Optional input inlets z One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

PSU50series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

1.6A Max.

Leakage current

3.5mA Max.@240VAC/50Hz

Output voltage

See rating chart (±5% tolerance)

Output current

See rating chart

Output power range

50 watts Max.

Ripple

1% peak to peak maximum

Over voltage protection

Provided on outputs set at 112~132% of its nominal output voltage

Over current protection

All outputs protected to short circuit conditions

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+30℃

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 30℃ linearly to 60% at 40℃

Efficiency

65% minimum at full output

Hold - up time

10msec minimum

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

15AMPS@115 VAC or 30AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

50,000 hours minimum at full load at 25℃ ambient

EMI requirements

Meet CE standards

Safety requirements

Meets or exceeds(A)UL1950 (B) CSA C22.2 (C) TUV EN60950-1(D)IEC 950

Warranty

1 year <28>


PSU50 50W Desktop series

Model name PSU50A-12 PSU50A-13 PSU50A-14 PSU50A-16 PSU50A-16-1 PSU50A-36 PSU50A-13D PSU50A-14E PSU50A-13D-1 Model name PSU50C-12 PSU50C-13 PSU50C-14 PSU50C-16 PSU50C-16-1 PSU50C-36 PSU50C-13D PSU50C-14E PSU50C-13D-1

Output#1 Vnom lmax +5VDC 4.50A +5VDC 4.00A +5VDC 4.00A +5VDC 2.00A +5VDC 2.00A +12VDC 2.20A +5VDC 4.00A +5VDC 4.00A +5VDC 5.00A Output#1 Vnom lmax +5VDC 4.50A +5VDC 4.00A +5VDC 4.00A +5VDC 2.00A +5VDC 2.00A +12VDC 2.20A +5VDC 4.00A +5VDC 4.00A +5VDC 5.00A

FIG1 Output#2 Vnom lmax +9VDC 1.70A +12VDC 2.00A +15VDC 1.80A +24VDC 1.00A +24VDC 1.50A +24VDC 1.00A +12VDC 2.00A +15VDC 1.50A +12VDC 1.00A FIG2 Output#2 Vnom lmax +9VDC 1.70A +12VDC 2.00A +15VDC 1.80A +24VDC 1.00A +24VDC 1.50A +24VDC 1.00A +12VDC 2.00A +15VDC 1.50A +12VDC 1.00A

Note: (1) Weight: Approx 510~560g (2)Optional output connectors (see page 81)

<29>

Output#3 Vnom lmax N/A N/A N/A N/A N/A N/A -12VDC 0.50A -15VDC 0.50A -12VDC 0.25A

Maximum Output Power 37.8W 44W 47W 49W 46W 50.4W 50W 50W 40W

Output#3 Vnom lmax N/A N/A N/A N/A N/A N/A -12VDC 0.50A -15VDC 0.50A -12VDC 0.25A

Maximum Output Power 37.8W 44W 47W 49W 46W 50.4W 50W 50W 40W


GMPU06

(FOR MEDICAL)

6W Wall mount series

Plug-in power supply Features: z Universal input voltage z No load power consumption<0.3W z Meet ENERGY STAR V z Single output z Optional output connectors z Short circuit protection z Over voltage protection z Over current protection z Means of patient protection design z Possess risk analysis report z Two years limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

GMPSU06 series:

Input voltage

100~240VAC

Input frequency

47~63Hz

Input current

0.18~0.09A Max.

Leakage current

0.1mA Max.

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes

Over current protection

Yes, Auto-recovery

Short circuit protection

Yes, Auto-recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 900n/sec after a 25% step load change

Operating temperature

0℃~+40℃

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at+40℃ linearly to 50% at 70℃

Avg. Efficiency

See rating chart

Hold up time

8m / Sec. minimum

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

30A Max @240 VAC/50Hz at 25℃ cold start

Withstand voltage

5656VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)EN60601-1-2:2007 (B)FCC PART 15 & PART 18 CLASS B

Safety requirements

(A)UL: ES60601-1; (B)CSA:C22.2 NO.60601-1:2008 (C)EN60601-1:2006

Warranty

2years <30>


GMPU06

(FOR MEDICAL)

6W Wall mount series

100%

70% 60% 50%

50%

40% 20%

10C 20C 30C 40C 50C 60C 70C

70

85

264

X=U American type (FIG1) or E European type (FIG2) X=S 3Pin Australian type (FIG3) or SA 2pin Australian type (FIG4) or BS UK type (FIG5) Line

Load

Regulation

Regulation

(%)

(%)

Avg. EFF (%) 25,50,75,100% load

80

±1

±5

69.54

<0.3

5

80

±1

±5

68.2

<0.3

5

6

80

±1

±5

74

<0.3

7.5

6

80

±1

±5

74

<0.3

9

0.55~0.46

6

120

±1

±5

74

<0.3

12

13~16

0.46~0.38

6

150

±1

±5

74

<0.3

15

GMPU06X -5

16~21

0.38~0.30

6

180

±1

±5

74

<0.3

18

GMPU06X -6

21~24

0.30~0.25

6

200

±1

±5

74

<0.3

24

Output

Output

Max .Output

Ripple(mV)

Voltage(VDC)

Current(A)

Power (W)

Max.

GMPU06X-1

5~6

1.20~1.00

6

GMPU06X-11

5

1

5

GMPU06X-1-1

6~8

1.00~0.75

GMPU06X -2

8~11

0.75~0.55

GMPU06X -3

11~13

GMPU06X -4

Model name

Note: 1. Weight: Approx 70~100g 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard Output cable: 5~8V:22AWG / UL2468 / 4FT ; 8~24V: 22AWG / UL2468 / 6FT <31>

No load Power Consumption(W)

Measured at the output of


GMPU18 18W Wall mount series

(FOR MEDICAL)

Features: z z z z z z z z z z z

z

Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Means of patient protection design Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

GMPU18 series:

Input voltage

100~240VAC

Input frequency

47~63Hz

Input current

0.7A Max.

Leakage current

0.1mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

1% peak to peak maximum. See rating Chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery

Short circuit protection

Yes. Hiccup mode ; Auto-recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chat

Insulation resistance

50Mohm. minimum from input to output

Inrush current

50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25℃ cold start

Withstand voltage

5656VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:EN60601-1-2:2007 CLASS B (B)FCC Part 15 / Part 18 Subpart B

Safety requirements

(A)UL:ES60601-1:2005(B)CSA:C22.2 NO.60601-1:2008(C)EN60601-1:2006

Warranty

2 years <32>


GMPU18 18W Wall mount series

(FOR MEDICAL)

F1G 1(UL) 31.8 12.7

F1G 2(TUV) 35.7 17.9

22

22 NAME PLATE

NAME PLATE

32

12

23.8

24

32 14

12 24 75.5

5

75.5 1.5

5

18.6

17.2

18.2

6 8.5

8.5 20

20

39

39

75.5

75.5

F1G 3(SA)

F1G 4(UK) NAME PLATE

22

6.3 39.8

7.9

1.6

48.8 NAME PLATE

12 24

32 120°

75.5

12 24

22.2

21.7 42 75.5

5 4

17.06

17.6

9.8

22

8

9.5

22.7

6.5 8.5

8.5 20

20 39

39

75.5

75.5 100% 100% 80%

70% 60%

60%

40% 20%

X=U American type (FIG1) or E European type (FIG2) or SA 2pin Australian type (FIG3) or BS UK type (FIG4) Max.

Output

Output

Voltage(VDC)

Current(A)

GMPU18X-1

5~6

3.00–2.50

15

GMPU18X-1-1

6~8

2.50-1.87

15

Model name

Ripple(mV)

Output Power (W)

0

10 C 20 C 30 C 40 C 50 C

Line

Ambient temperature( c) Derating Load Avg.

EFF (%)

60

85 90 100

264

Typical static characteristics Measured

No load Power

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

80

±1

±5

76.42

<0.3

5

80

±1

±5

79.20

<0.3

7.5

Max.

Consumption(W)

at the output of

GMPU18X-2

8~11

2.25-1.64

18.04

100

±1

±5

80.30

<0.3

9

GMPU18X-3

11~13

1.64-1.38

18.04

120

±1

±5

82.40

<0.1

12

GMPU18X-4

13~16

1.38-1.13

18.08

150

±1

±5

82.40

<0.1

15

GMPU18X-5

16~21

1.13-0.86

18.08

150

±1

±5

82.40

<0.1

18

GMPU18X-6

21~27

0.86-0.67

18.09

150

±1

±5

82.40

<0.1

24

GMPU18X-7

27~33

0.67-0.55

18.15

240

±1

±3

82.40

<0.1

28

GMPU18X-8

33~58

0.55-0.32

18.56

240

±1

±3

82.40

<0.1

48

Note: Note: 1. Weight: Approx 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT 13~58V: 22WG / UL2468 / 6FT

<33>


GMPU18 18W Wall mount interchangeable series

(FOR MEDICAL)

Features: z z z z z z z z z z z

z

Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Means of patient protection design Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

GMPU18 series:

Input voltage

100~240VAC

Input frequency

47~63Hz

Input current

0.7A Max.

Leakage current

0.1mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

1% peak to peak maximum. See rating Chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery

Short circuit protection

Yes. Hiccup mode ; Auto-recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chat

Insulation resistance

50Mohm. minimum from input to output

Inrush current

50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25℃ cold start

Withstand voltage

5656VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:EN60601-1-2:2007 CLASS B (B)FCC Part 15 / Part 18 Subpart B

Safety requirements

(A)UL:ES60601-1:2005(B)CSA:C22.2 NO.60601-1:2008(C)EN60601-1:2006

Warranty

2 years <34>


GMPU18 18W Wall mount interchangeable series

(FOR MEDICAL)

F1G 1(UL) 32

F1G 2(TUV) 35.3

22 NAME PLATE

NAME PLATE

OPEN

OPEN

39.1

24

PUSH

PUSH

24

LOCK

39.1 33 12.7

LOCK

22

5

35.3

5

80.5

80.5 19.2 17.2 18.1

6.7

5.7

15.5

15.5 40.7 40.7

F1G 4(UK)

F1G 3(SA) 35.3

NAME PLATE

49.4

OPEN

OPEN

22.2

24

LOCK

PUSH

24

PUSH

NAME PLATE

41 39.1

22

22

LOCK

5 42.3

5

80.5

80.5

17

22.8

17.6

8.7

8.2

15.5

15.5

40.7

40.7

PUSH LOCK

LOCK

OPEN

OPEN

100%

PUSH

(UL)

100%

(TUV)

70% 60%

80%

60%

40% 20% PUSH

LOCK

OPEN

OPEN

LOCK

PUSH

10 C 20 C 30 C 40 C 50 C

0

Ambient temperature( c) Derating

(SA)

60

85 90 100

264

Typical static characteristics

(UK)

X=U American type (FIG1) or E European type (FIG2) or or SA 2pin Australian type (FIG3) or BS UK type (FIG4) Max.

Output

Output

Voltage(VDC)

Current(A)

GMPU18X-1

5~6

3.00–2.50

15

GMPU18X-1-1

6~8

2.50-1.87

15

GMPU18X-2

8~11

2.25-1.64

18.04

Model name

Line

Load

Avg. EFF (%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

80

±1

±5

76.42

<0.3

5

80

±1

±5

79.20

<0.3

7.5

100

±1

±5

80.30

<0.3

9

Ripple(mV)

Output Power (W)

Max.

No load Power Consumption(W)

Measured at the output of

GMPU18X-3

11~13

1.64-1.38

18.04

120

±1

±5

85.10

<0.1

12

GMPU18X-4

13~16

1.38-1.13

18.08

150

±1

±5

85.10

<0.1

15

GMPU18X-5

16~21

1.13-0.86

18.08

150

±1

±5

85.10

<0.1

18

GMPU18X-6

21~27

0.86-0.67

18.09

150

±1

±5

85.10

<0.1

24

GMPU18X-7

27~33

0.67-0.55

18.15

240

±1

±3

85.10

<0.1

28

GMPU18X-8

33~58

0.55-0.32

18.56

240

±1

±3

85.10

<0.1

48

Note: Note: 1. Weight: Approx 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT 13~58V: 22WG / UL2468 / 6FT

<35>


GMPU18 18W Desktop series

(FOR MEDICAL)

Features: z z z z z z z z z z z

z

Universal input voltage Meet ENERGY STAR V Single output Pass LPS Optional output connectors Short circuit protection Over voltage protection Over current protection Means of patient protection design Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

SAFETY AGENCY APPROVALS:

(Only FIG 2)

(Only FIG 2)

(Only FIG 2)

Specifications:

GMPU18 series:

Input voltage

100~240VAC

Input frequency

47~63Hz

Input current

0.7A Max.

Leakage current

0.1mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

1% peak to peak maximum. See rating Chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery

Short circuit protection

Yes. Hiccup mode ; Auto-recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chat

Insulation resistance

50Mohm. minimum from input to output

Inrush current

50 AMPS@115 VAC ; 90AMPS @ 230VAC at 25℃ cold start

Withstand voltage

5656VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:EN60601-1-2:2007 CLASS B (B)FCC Part 15 / Part 18 Subpart B

Safety requirements

(A)UL:ES60601-1:2005(B)CSA:C22.2 NO.60601-1:2008(C)EN60601-1:2006

Warranty

2 years <36>


GMPU18 18W Wall mount series / Desktop series

(FOR MEDICAL)

58.5

58.5

32.8

32.8

29.25

FIG 1 100

58.5

FIG 2 58.5

100% 100%

FIG 3

80%

70% 60%

60%

40% 20% 0

10 C 20 C 30 C 40 C 50 C

Ambient temperature( c) Derating

60

85 90 100

264

Typical static characteristics

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D MAINS CORD INPUT Max.

Output

Output

Voltage(VDC)

Current(A)

GMPU18X-1

5~6

3.00–2.50

15

GMPU18X-1-1

6~8

2.50-1.87

15

GMPU18X-2

8~11

2.25-1.64

18.04

Model name

Line

Load

Avg. EFF (%)

Regulation

Regulation

25,50,75,100%

(%)

(%)

load

80

±1

±5

76.42

<0.3

5

80

±1

±5

79.20

<0.3

7.5

100

±1

±5

80.30

<0.3

9

Ripple(mV)

Output Power (W)

Max.

No load Power Consumption(W)

Measured at the output of

GMPU18X-3

11~13

1.64-1.38

18.04

120

±1

±5

85.10

<0.1

12

GMPU18X-4

13~16

1.38-1.13

18.08

150

±1

±5

85.10

<0.1

15

GMPU18X-5

16~21

1.13-0.86

18.08

150

±1

±5

85.10

<0.1

18

GMPU18X-6

21~27

0.86-0.67

18.09

150

±1

±5

85.10

<0.1

24

GMPU18X-7

27~33

0.67-0.55

18.15

240

±1

±3

85.10

<0.1

28

GMPU18X-8

33~58

0.55-0.32

18.56

240

±1

±3

85.10

<0.1

48

Note: Note: 1. Weight: Approx 2. Optional output connectors (see page 81) 3. ENERGY STAR V Standard output cable: 5~13V: 20AWG / UL2468 / 4FT 13~58V: 22WG / UL2468 / 6FT

<37>


MPU30 30W Desktop series

(FOR MEDICAL)

Desktop power supply Features: z z z z z z z z z z z

z

Universal input voltage Single output Optional output connectors High efficiency & reliability Compact package Optional input inlets Over voltage protection Over current protection Over Temperature protection Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

SAFETY AGENCY APPROVALS: Specifications:

MPU30series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

0.8~0.4A Max.

Leakage current

Class1:0.3mA/Class2:0.1mA Max.@240VAC/50Hz

Output voltage

See rating chart (±5% tolerance)

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Provided on outputs set at 112~132% of its nominal output voltage

Over current protection

All outputs protected to short circuit conditions

Over Temperature protection

130℃ Activated

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Efficiency

See rating chart

Hold - up time

10msec minimum

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

35AMPS@115 VAC or 65AMPS @ 230VAC at 25℃ cold start

Withstand voltage

5656VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements Safety requirements

(A)EN60601-1-2:2007 (B)FCC PART 15 & PART 18 CLASS B Meets or Exceeds(A)UL: ES60601-1:2005 (B)CSA: C22.2 NO.60601-1:2008 (C)CB: IEC 60601-1:2005 (D)EN:EN60601-1:2006

Warranty

2 years <38>


MPU30 30W Desktop series

(FOR MEDICAL)

X=A IEC-320-C14 (FIG1) or B IEC-320-C8 (FIG2) or C IEC-320-C6 (FIG3) or D=MAINS CORD INPUT Model name

Output

Output

Max. Output

Ripple(mV)

Voltage(VDC)

Current(A)

Power (W)

Max.

Line

Load

Regulation

Regulation

(%)

(%)

Efficiency (%)

Measured at the

(min)

output of

3.3

MPU30X-0

3~5

5

25

30

±1

±8

65

MPU30X -1

5~6

5.00~4.17

25

30

±1

±8

68

5

MPU30X -1-1

6~8

4.17~3.13

25

40

±1

±4

70

7.5

MPU30X-2

8~11

3.75~2.73

30

50

±1

±4

74

9

MPU30X -3

11~13

2.73~2.30

30

50

±1

±3

75

12

MPU30X -4

13~16

2.30~1.88

30

60

±1

±3

75

15

MPU30X -5

16~21

1.88~1.43

30

70

±1

±2

76

18

MPU30X -6

21~27

1.43~1.11

30

80

±1

±2

77

24

MPU30X -7

27~33

1.11~0.90

30

100

±1

±2

78

28

MPU30X -8

33~48

0.90~0.63

30

100

±1

±2

78

48

Y=U American type or E European type AC power Model name

Output

Output

Voltage(VDC)

Current(A)

Max. Output Power (W)

Ripple(mV)

Line

Load

Efficiency (%)

Measured at the

Max.

Regulation (%)

Regulation (%)

(min)

output of

3.3

MPU30D -0-Y

3~5

5

25

30

±1

±8

65

MPU30D -1-Y

5~6

5.00~4.17

25

30

±1

±8

68

5

MPU30D -1-1-Y

6~8

4.17~3.13

25

40

±1

±4

70

7.5

MPU30D -2-Y

8~11

3.75~2.73

30

50

±1

±4

74

9

MPU30D -3-Y

11~13

2.73~2.30

30

50

±1

±3

75

12

MPU30D -4-Y

13~16

2.30~1.88

30

60

±1

±3

75

15

MPU30D -5-Y

16~21

1.88~1.43

30

70

±1

±2

76

18

MPU30D -6-Y

21~27

1.43~1.11

30

80

±1

±2

77

24

MPU30D -7-Y

27~33

1.11~0.90

30

100

±1

±2

78

28

MPU30D -8-Y

33~48

0.90~0.63

30

100

±1

±2

78

48

Note: (1) Weight: Approx 300~350g (2)Optional output connectors (see page 81)

<39>


MPU50 50W Desktop series

( FOR MEDICAL)

Desktop power supply Features: z Universal input voltage z Single output z Optional output connectors z High efficiency & reliability z Compact package z Over voltage protection z Over current protection z Over Temperature protection z Possess risk analysis report z Meet 60601-1 3rd edition z Two years limited warranty

FIG 1

FIG 2

SAFETY AGENCY APPROVALS: Specifications:

MPU50A,C series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

1.5~0.8A Max.

Leakage current

0.3mA Max.@240VAC/50Hz

Output voltage

See rating chart (±5% tolerance)

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Provided on outputs set at 112~132% of its nominal output voltage

Over current protection

All outputs protected to short circuit conditions

Over Temperature protection

130℃ Activated

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Efficiency

See rating chart

Hold - up time

10msec minimum

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

65AMPS@115 VAC or 90AMPS @ 230VAC at 25℃ cold start

Withstand voltage

5656VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)EN60601-1-2:2007 (B)FCC PART 15 & PART 18 CLASS B Meets or Exceeds(A)UL: ES60601-1:2005 (B)CSA: C22.2 NO.60601-1:2008

Safety requirements

(C)CB: IEC 60601-1:2005 (D)EN:EN60601-1:2006 Warranty

2 years <40>


MPU50 50W Desktop series

(FOR MEDICAL)

X= A (C14 FIG1) or C (C6 FIG2) Max.

Line

Load Regulation

(%)

(%)

Output

Voltage(VDC)

Current(A)

Efficiency (%)

No load Power

(min)

Consumption(W)

MPU50X-0

3~5

7.50

37.5

50

±1

MPU50X -1

5~6

7.50~6.25

37.5

50

±1

±8

60

3.3

±6

67

MPU50X -1-1

6~8

6.66~5.00

40

75

±1

5

±5

70

7.5

MPU50X-2

8~11

5.62~4.09

45

90

MPU50X -3

11~13

4.54~3.84

50

100

±1

±5

72

9

±1

±5

74

12

MPU50X -4

13~16

3.84~3.12

50

MPU50X -5

16~21

3.12~2.38

50

100

±1

±3

75

15

150

±1

±3

78

MPU50X -6

21~27

2.38~1.85

18

50

150

±1

±2

78

MPU50X -7

27~33

24

1.85~1.51

50

200

±1

±2

78

MPU50X -8

33~48

28

1.51~1.04

50

200

±1

±2

80

48

Output Power (W)

Ripple(mV)

Regulation

Output

Model name

Max.

Note: (1) Weight: Approx 510~560g (2)Optional output connectors (see page 81)

<41>


GMPU70 70W Desktop series

(FOR MEDICAL)

Desktop power supply Features: z z z z z z z z z

z z z

Universal input voltage Meet ENERGY STAR V Single output Over voltage protection Over current protection Short circuit protection Means of patient protection design Low leakage current Output voltage 5~58VDC Possess risk analysis report Meet 60601-1 3rd edition Two years limited warranty

FIG 1

FIG 2

SAFETY AGENCY APPROVALS: Specifications:

GMPSU70 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

1.8~0.8A Max.

Leakage current

<0.3mA

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes.<140% output voltage

Over current protection

Yes.>120% output current, Auto-recover

Short protection

Yes. Hiccup mode, Auto-recover

Temperature coefficient Transient response

All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

-20℃~+40℃.

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 50% at 70℃

Efficiency

See rating chart

Hold - up time

8mS min.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

100AMPS @ 230VAC at 25℃ cold start

Withstand voltage

5656VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)EN60601-1-2:2007 (B)FCC PART 15 & PART 18 CLASS B

Safety requirements

Meets or exceeds: (A) UL : ES60601-1:2005 (B) CSA:C22.2 NO. 60601-1:2008 (C) EN60601-1:2006 (D) IEC60601-1:2005

Warranty

2 years <42>


GMPU70 70W Desktop series

(FOR MEDICAL)

X=A (C14 FIG1) or C (C6 FIG2) Model name

GMPU70X-1 GMPU70X-1-1 GMPU70X-2 GMPU70X-3 GMPU70X-4 GMPU70X-5 GMPU70X-6 GMPU70X-7 GMPU70X-8

Max.

Ripple(mV)

Output

Voltage(VDC)

Current(A)

5~6 6~8 8~11 11~13 13~16 16~21 21~27 27~33 33~58

7.50~6.36

37.5

200

±1

±5

83.4

5

7.50~5.63

45

100

±1

±5

86.10

7.5

7.50~5.46

60

120

±1

±5

87

9

6.37~5.39

70

120

±1

±5

87

12

5.39~4.38

70

120

±1

±5

87

15

4.38~3.34

70

180

±1

±5

87

18

3.34~2.60

70

180

±1

±5

87

24

2.60~2.13

70

240

±1

±5

87

32

2.13~1.22

70

240

±1

±5

87

48

Output Power (W)

Max.

Regulation (%)

Note: (1) Weight: Approx 370~375g (2) Optional output connectors (see page 81) (3) ENERGY STAR V standard output cable: 5~16V: UL1571 _14AWG_ 4FT 17~58V: SPT-1 _18AWG_ 6FT <43>

Line

Output

Load Regulation (%)

Avg. EFF (%)

No load Power Consumption(W)


GPSU06X-CC 6W Wall mount charger series Plug-in power supply Features: z Universal input voltage z Single output z Pass LPS z Optional output connectors z Short circuit protection z High efficiency & reliability z Outputs are available at request z Compact package z One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection

GPSU06X-CC series: 100~240VAC 50~60Hz 0.2A Max. 0.25mA Max.@240VAC/50Hz See rating chart See rating chart See rating chart See rating chart Yes, Protected by Zener diode Yes. Auto-recovery Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection Temperature coefficient

Yes. Hiccup mode ; Auto- recovery All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change 0℃~+40℃.See derating curve -40℃~+85℃ 5% to 95% non-condensing Derated from 100% at+40℃ linearly to 70% at 50℃ See rating chart Typical: 3000mS / 16mS / 50mS at full load. ±1% maximum for any input voltage change between input voltage range Typical±5% variations from minimum to maximum output current. Or see rating chart 50Mohm minimum from input to output 30 AMPS@115 VAC;60AMPS @ 230VAC at 25℃ cold start 4242VDC from input to output 100,000 hours minimum at full load at 25℃ ambient (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11 (B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1 1year

Operating temperature Storage temperature Relative humidity Derating Avg. Efficiency Setup up/Hold up/Rise time Line regulation Load regulation Insulation resistance Inrush current Withstand voltage Mean time between failure EMI requirements Safety requirements Warranty

<44>


GPSU06X-CC 6W Wall mount charger series

X=U American type (FIG1) or E European type (FIG2) or S 3pin Australian type (FIG3) Or SA 2pin Australian type (FIG4) or BS UK type (FIG5) Max.

Ripple

Load

Measured

Output

Output

Output

Voltage(VDC)

Current(A)

Power

GPSU06X-0-CC

3~5

1.33~0.80

4

50

±1

±10

45

<0.5

3.3

GPSU06X-1-CC

5~6

1.00~0.80

5

50

±0.5

±6

60

<0.5

5.6

GPSU06X-1-1-CC

6~8

1.00~0.75

6

80

±0.5

±5

65

<0.5

7.2

GPSU06X-2-CC

8~11

0.75~0.54

6

80

±0.5

±5

70

<0.5

8.4

GPSU06X-3-CC

11~13

0.54~0.46

6

100

±0.5

±4

74

<0.5

12

GPSU06X-4-CC

13~16

0.46~0.37

6

120

±0.5

±4

74

<0.5

13.8

GPSU06X-5-CC

16~21

0.37~0.28

6

150

±0.5

±4

74

<0.5

18

GPSU06X-6-CC

21~27

0.28~0.20

6

180

±0.5

±3

75

<0.5

24

GPSU06X-7-CC

27~33

0.20~0.18

6

200

±0.5

±3

75

<0.5

30

GPSU06X-8-CC

33~48

0.18~0.12

6

200

±0.5

±3

75

<0.5

48

Model

(W)

(mV) Max.

Line Regulation (%)

Note: 1. Weight: Approx 70~100g 2. Optional output connectors (see page 81)

<45>

Regulation

Efficiency(%)(min)

(%)

No load Power Consumption(W)

at the output of


GPSU15X-CC 15W Wall mount charger series Plug-in power supply Features: z Universal input voltage z Single output z Pass LPS z Optional output connectors z Short circuit protection z High efficiency & reliability z Outputs are available at request z Compact package z One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection

GPSU15X-CC series : 100~240VAC 50~60Hz 0.5A Max. 0.25mA Max.@240VAC/50Hz See rating chart See rating chart See rating chart See rating chart Yes, Protected by Zener diode Yes. Auto-recovery Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection Temperature coefficient Transient response Operating temperature Storage temperature Relative humidity Derating Avg. Efficiency Setup up / Hold up / Rise time Line regulation Load regulation Insulation resistance Inrush current Withstand voltage Mean time between failure EMI requirements Safety requirements Warranty

Yes. Hiccup mode ; Auto-recovery All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change 0℃~+40℃.See derating curve -40℃~+85℃ 5% to 95% non-condensing Derated from 100% at + 40℃ linearly to 70% at 50℃ See rating chart Typical: 3000mS / 16mS / 50mS at full load. ±1% maximum for any input voltage change between input voltage range Typical±5% variations from minimum to maximum output current. 50Mohm. minimum form input to output 20 AMPS@115 VAC ; 40AMPS @ 230VAC at 25℃ cold start 4242VDC from input to output 100,000 hours minimum at full load at 25℃ ambient (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11 (B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1 1year <46>


GPSU15X-CC 15W Wall mount charger series

X=U American type (FIG1) or E European type (FIG2) or S 3pin Australian type (FIG3) or SA 2pin Australian type (FIG4) or BS UK type (FIG5) Max. Model name

Output

Output

Output

Ripple(mV)

Voltage(VDC)

Current(A)

Power

Max.

(W)

Line

Load

Regulation

Regulation

(%)

(%)

Efficiency(%)(min)

No load Power

Measured at

Consumption(W)

the output of

GPSU15X-1-CC

5~6

2.4~2.00

12

50

±0.5

±10

65

<0.5

5.6

GPSU15X-1-1-CC

6~8

2.00~1.50

12

80

±0.5

±5

74

<0.5

7.2

GPSU15X-2-CC

8~11

1.80~1.36

15

80

±0.5

±5

76

<0.5

8.4

GPSU15X-3-CC

11~13

1.36~1.15

15

100

±0.5

±5

76

<0.5

12

GPSU15X-4-CC

13~16

1.15~0.94

15

120

±0.5

±3

76

<0.5

13.8

GPSU15X-5-CC

16~21

0.94~0.72

15

120

±0.5

±3

77

<0.5

18

GPSU15X-6-CC

21~27

0.72~0.55

15

150

±0.5

±3

78

<0.5

24

GPSU15X-7-CC

27~33

0.55~0.45

15

240

±0.5

±2

80

<0.5

30

GPSU15X-8-CC

33~48

0.45~0.31

15

240

±0.5

±2

80

<0.5

48

Note: 1. Weight: Approx 70~150g 2. Optional output connectors (see page 81)

<47>


GPSU15X-CC 15W Desktop charger series Desktop power supply Features: z Universal input voltage z Single output z Pass LPS z Optional output connectors z Short circuit protection z High efficiency & reliability z Outputs are available at request z Compact package z One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

GPSU15X-CC series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

0.5A Max.

Leakage current

0.25mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection

Yes. Hiccup mode ; Auto- recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chart

Insulation resistance

50Mohn minimum from input to output

Inrush current

20 AMPS@115 VAC ; 40AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11 (B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003

Safety requirements

(A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1

Warranty

1year <48>


GPSU15X-CC 15W Desktop charger series

X=A IEC-320-C14(FIG1) or B IEC-320-C8(FIG2) or C IEC-320-C6(FIG3) D= MAINS CORD INPUT Model name

Output

Output

Voltage(VDC)

Current(A)

Max. Output Power (W)

Ripple (mV) Max.

Line

Load

Regulation

Regulation

(%)

(%)

Efficiency(%)(min)

No load Power

Measured at

Consumption(W)

the output of

GPSU15X-1-CC

5~6

2.40~2.00

12

50

±0.5

±10

65

<0.5

5.6

GPSU15X-1-1-CC

6~8

2.00~1.50

12

80

±0.5

±5

74

<0.5

7.2

GPSU15X-2-CC

8~11

1.80~1.36

15

80

±0.5

±5

76

<0.5

8.4

GPSU15X-3-CC

11~13

1.36~1.15

15

100

±0.5

±5

76

<0.5

12

GPSU15X-4-CC

13~16

1.15~0.94

15

120

±0.5

±3

76

<0.5

13.8

GPSU15X-5-CC

16~21

0.94~0.72

15

120

±0.5

±3

77

<0.5

18

GPSU15X-6-CC

21~27

0.72~0.55

15

150

±0.5

±3

78

<0.5

24

GPSU15X-7-CC

27~33

0.55~0.45

15

240

±0.5

±2

80

<0.5

30

GPSU15X-8-CC

33~48

0.45~0.31

15

240

±0.5

±2

80

<0.5

48

Y=U American type or E European type Max. Model name

Output

Output

Output

Voltage(VDC)

Current(A)

Power (W)

Ripple

Line

Load

(mV)

Regulation

Regulation

Max.

(%)

(%)

Efficiency(%)(min)

No load Power

Measured at

Consumption(W)

the output of

GPSU15D-1-Y-CC

5~6

2.4~2.00

12

50

±0.5

±10

65

<0.5

5.6

GPSU15D-1-1-Y-CC

6~8

2.00~1.50

12

80

±0.5

±5

74

<0.5

7.2

GPSU15D-2-Y-CC

8~11

1.80~1.36

15

80

±0.5

±5

76

<0.5

8.4

GPSU15D-3-Y-CC

11~13

1.36~1.15

15

100

±0.5

±5

76

<0.5

12

GPSU15D-4-Y-CC

13~16

1.15~0.94

15

120

±0.5

±3

76

<0.5

13.8

GPSU15D-5-Y-CC

16~21

0.94~0.72

15

120

±0.5

±3

77

<0.5

18

GPSU15D-6-Y-CC

21~27

0.72~0.55

15

150

±0.5

±3

78

<0.5

24

GPSU15D-7-Y-CC

27~33

0.55~0.45

15

240

±0.5

±2

80

<0.5

30

GPSU15D-8-Y-CC

33~48

0.45~0.31

15

240

±0.5

±2

80

<0.5

48

Note: 1. Weight: Approx 100~250g 2. Optional output connectors (see page 81)

<49>


GPSU30X-CC 30W Desktop charger series

(class2)

Desktop power supply Features: z z z z z z z z z z

Universal input voltage Single output & Optional output connectors Short circuit protection Over voltage protection Over current protection Over temperature protection Constant Voltage & Constant Current 6~33 Vouch include reverse protection 2 color LED indicator for loading status One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection Constant current protection Output short protection Over thermal protection Temperature coefficient Transient response Operating temperature Storage temperature Relative humidity Derating Efficiency Setup up / Hold up / Rise time Line regulation Load regulation Inrush current Withstand voltage Mean time between failure EMI requirements

Safety requirements Warranty

GPSU30X-CC series: 100~240VAC 50~60Hz 0.7A Max. 0.25mA Max.@240VAC/50Hz See rating chart See rating chart See rating chart See rating chart 110%~135% rated output voltage , pritected by Zener diode Yes. 90%~110% constant limiting Yes. 140℃±10℃, auto-recovery by IC1 Tj All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change 0℃~+40℃.See Derating chart -40℃~+85℃ 5% to 95% non-condensing Derated from 100% at + 40℃ linearly to 70% at 50℃ See rating chart 3000mS / 16mS / 50mS ±1% maximum for any input voltage change between input voltage range ±5% variations from minimum to maximum output current. Or see rating chart 15AMPS @ 115VAC or 40 AMPS @ 230VAC at 25℃ cold start 4242VDC from input to output 100,000 hours minimum at full load at 25℃ ambient (A)CE:Emission:EN55022;EN61000-3-2,3/lmmunity:IEC61000-4-2,3,4,5,6,11 (B)FCC 47 CFR Part 15 Subpart B .ICES-003 lssue 4 ANSI C63.4-2003 (C)VCCI J55014(H14):2001 (A)UL60950-1 (B)CSA C22.2 (C)TUV EN60950-1 1year <50>


GPSU30X-CC 30W Desktop charger series

(class2)

X=B IEC-320-C8 (FIG1) or U American TYPE (FIG2) or E European Type (FIG3) Line

Load

Regulation

Regulation

Output

Output

Max. Output

Ripple(mV)

Voltage(VDC)

Current(A)

Power (W)

Max.

(%)

(%)

*GPSU30X-0-CC

3~5

4

20

50

1

3.6~4.4

55

<1

4.2

*GPSU30X-1-CC

5~6

4.00~3.73

22.38

50

0.5

5~5.8

70

<1

5.6

GPSU30X-1-1-CC

6~8

3.60~2.70

21.60

80

0.5

6.5~7.5

70

<1

7.2

GPSU30X-2-CC

8~11

3.15~2.30

25.20

80

0.5

7.7~8.6

70

<1

8.4 14.3

Model name

Efficiency(%)(min)

No load Power

Measured at

Consumption(W)

the output of

GPSU30X-4-CC

13~16

2.30~1.87

30

100

0.5

13.5~14.5

78

<1

GPSU30X-5-CC

16~21

1.68~1.28

27

100

0.5

16~17

78

<1

16.8

GPSU30X-6-CC

27~33

1.11~0.90

30

150

0.5

27.1~28.8

80

<1

28.6

*NO LPS SAFETY Note: 1. Weight: Approx 300~400g 2. Optional output connectors (see page 81)

<51>

↑


GPSO15

open frame series

Features: z Universal input voltage z Meet ENERGY STAR V for 5~48VDC z Short circuit z Over voltage protections z Over load protections z Low leakage current z Simple constant current (Option) z One year limited warranty

SAFETY AGENCY APPROVALS:

Application: General power Specifications:

GPSO15 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

0.5A Max.

Leakage current

0.25mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection

Yes. Hiccup mode ; Auto- recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chart

Insulation resistance

50Mohn minimum from input to output

Inrush current

20 AMPS@115 VAC ; 40AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

CE

Safety requirements

Reference design: (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1

Warranty

1 years

Dimension(mm)

72x62x28

Weight(g)

70g <52>


GPSO15

open frame series

Mechanical Specification

72 3.5

3.5 3.5

3.5

3.5

DANGER

HIGH VOL TAGE

3.5

62

CN1

CN2

123

12

3.5 3.5

28 23 1.6

3.4

AC input connector (CN1): Molex5273 series or equivalent Pin number Assignment Mating Housing 1

AC-L

2

N.C.

3

AC-N

Terminal

Molex5058 or equivalent

Molex2478 or equivalent

DC output connector (CN2): Molex5273 series or equivalent Pin number Assignment Mating Housing

Terminal

-v +v

Molex5194 or equivalent

1 2

Model name

Molex5195 or equivalent

Output

Output

Max .Output

Ripple(mV)

Line

Load

Avg. EFF (%)

Voltage(VDC)

Current (A)

Power (W)

Max.

Regulation (%)

Regulation (%)

25,50,75,100% load

GPSO15-1

5~6

2.40~2.00

12

50

1

3

74.78

GPSO15-1-1

6~8

2.00~1.50

12

80

1

2

78.3

GPSO15-2

8~11

1.80~1.36

15

80

1

2

79.7

GPSO15-3

11~13

1.36~1.15

15

80

1

2

79.7

GPSO15-4

13~16

1.15~0.94

15

100

1

2

79.7

GPSO15-5

16~21

0.94~0.72

15

120

1

2

79.7

GPSO15-6

21~27

0.72~0.55

15

150

1

2

80

GPSO15-7

27~33

0.55~0.45

15

240

1

2

80

GPSO15-8

33~48

0.45~0.31

15

240

1

2

81

<53>

↑


GPSO30

open frame series

Features: z Universal input voltage z No load power consumption<0.5W z Vout above 7.5V Meet ENERGY STAR V z Single output z Short circuit protection z Over voltage protection z Over current protection z One year limited warranty

SAFETY AGENCY APPROVALS:

Application: General power Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection Short circuit protection Temperature coefficient Transient response Operating temperature Storage temperature Relative humidity Derating Avg.Efficiency Hold up time Line regulation Load regulation Insulation resistance Inrush current Withstand voltage Mean time between failure EMI requirements Safety requirements Warranty Dimension(mm) Weight(g)

GPSO30 series: 100~240VAC 50~60Hz 1A Max. Class1:3.5mA/Class2:0.25mA See rating chart See rating chart See rating chart See rating chart Yes. Yes. Yes. All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change 0℃~+40℃. -40℃~+85℃ 5% to 95% non-condensing Derated from 100% at + 40℃ linearly to50% at 70℃ See rating chart 10m/sec minimum ±1% maximum for any input voltage change between input voltage range ±5% variations from minimum to maximum output current. 50Mohm minimum from input to output 60AMPS@115 VAC ; 80AMPS @ 230VAC at 25℃ cold start 4242VDC from input to output 100,000 hours minimum at full load at 25℃ ambient CE Reference design (A)UL60950-1 (B) EN60950-1; IEC60950-1 (C) J60950 1 year 128x40x29 140g <54>


GPSO30

open frame series

Mechanical Specification UNIT mm

AC input connector (CN1): Molex5237 series or equivalent Pin number Assignment Mating Housing 1

AC-N

2

AC-L

Terminal

Molex5058 or equivalent

Molex2478 or equivalent

DC output connector (CN2): Molex5237 series or equivalent Pin number Assignment Mating Housing

Vo+ Vo+ VoVo-

1 2 3 4

Model name

Terminal

Molex5195 or equivalent

Molex5194 or equivalent

Output

Output

Max .Output

Ripple(mV)

Line

Load

Avg. EFF (%)

Voltage(VDC)

Current (A)

Power (W)

Max.

Regulation (%)

Regulation (%)

25,50,75,100% load

GPSU30-0

3~5

5

15~25

80

±1

±5

64

GPSO30-1

5~6

5.00~4.15

25

80

±1

±3

70

GPSU30-1-1

6~8

4.15~3.13

25

80

±1

±3

76

GPSO30-2

8~11

3.71~2.73

30

80

±1

±3

77

GPSO30-3

11~13

2.70~2.31

30

120

±1

±3

81

GPSO30-4

13~16

2.29~1.88

30

140

±1

±3

82

GPSO30-5

16~21

1.86~1.43

30

140

±1

±3

82

GPSO30-6

21~27

1.43~1.12

30

150

±1

±3

84

GPSO30-7

27~33

1.12~0.91

30

240

±1

±3

84

GPSO30-8

33~50

0.91~0.61

30

240

±1

±3

85

<55>


GPSO40

open frame series

Features: z Universal input voltage z No load power consumption<0.3W z Meet ENERGY STAR V z Single output z Short circuit protection z Over voltage protection z Over current protection z One year limited warranty

SAFETY AGENCY APPROVALS:

Application: General power Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection Short circuit protection Temperature coefficient Transient response Operating temperature Storage temperature Relative humidity Derating Avg. Efficiency Hold up time Line regulation Load regulation Insulation resistance Inrush current Withstand voltage Mean time between failure EMI requirements Safety requirements Warranty Dimension(mm) Weight(g)

GPSO40 series: 100~240VAC 50~60Hz 1A Max. Class1:3.5mA/Class2:0.25mA See rating chart See rating chart See rating chart See rating chart Yes. Yes. Yes. All output±0.04%/℃ maximum Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change 0℃~+40℃. -40℃~+85℃ 5% to 95% non-condensing Derated from 100% at + 40℃ linearly to50% at 70℃ See rating chart 10m/sec minimum ±1% maximum for any input voltage change between input voltage range ±5% variations from minimum to maximum output current. 50Mohm minimum from input to output 60AMPS@115 VAC ; 80AMPS @ 230VAC at 25℃ cold start 4242VDC from input to output 100,000 hours minimum at full load at 25℃ ambient CE Reference design (A)UL60950-1 (B) EN60950-1; IEC60950-1 (C) J60950 1 year 102x63x28.9 140g <56>


GPSO40

open frame series 102

Mechanical Specification

3.3

3.3

UNIT mm

3.3

3.3

4-3

FG

CN1

1 2 3

63

+

CN2

-

1 2

3.3

3.3

3.3

3.3

28.9 27 1.5

AC input connector (CN1): Molex5237 series or equivalent Pin number Assignment Mating Housing 1

AC-L

2

FG

3

AC-N

Terminal

Molex5058 or equivalent

Molex2478 or equivalent

DC output connector (CN2): Molex5237 series or equivalent Pin number Assignment Mating Housing

Terminal

+v -v

Molex5194 or equivalent

1 2

Model name

Molex5195 or equivalent

Output

Output

Max .Output

Ripple(mV)

Line

Load

Avg. EFF (%)

Voltage(VDC)

Current (A)

Power (W)

Max.

Regulation (%)

Regulation (%)

25,50,75,100% load

GPSO40-1

5~6

5.00~4.17

25

350

1

3

79

GPSU40-1-1

6~8

5.00~3.75

30

200

1

3

81

GPSO40-2

8~11

4.38~3.18

35

120

1

3

82

GPSO40-3

11~13

3.64~3.08

40

130

1

2

85

GPSO40-4

13~16

3.08~2.50

40

250

1

2

85

GPSO40-5

16~21

2.82~2.15

45

250

1

2

86

GPSO40-6

21~27

2.15~1.67

45

300

1

2

86

GPSO40-7

27~33

1.67~1.37

45

300

1

2

86

GPSO40-8

33~50

1.37~0.90

45

400

1

2

86

<57>

↑


LEO15 for LED power series Features: z Universal input voltage z Short circuit z Over voltage protections z Over load protections z Low leakage current z Simple constant current (Option) z One year limited warranty

SAFETY AGENCY APPROVALS:

Application: General power or LED power Specifications:

LEO15 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

0.5A Max.

Leakage current

0.25mA Max.@240VAC/50Hz

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating Chart

Over voltage protection

Yes, Protected by Zener diode

Over current protection

Yes. Auto-recovery Standard Series: Rated output current>110% for primary-referenced direct drive (Constant current series: Rated output current 80~200% for secindary-referenced direct drive)

Short circuit protection

Yes. Hiccup mode ; Auto- recovery

Temperature coefficient

All output±0.04%/℃ maximum

Transient response

Maximum excursion of 4% or better on all models. Recovering to 1% of final value within 500uS after a 25% step load change

Operating temperature

0℃~+40℃.See derating curve

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at + 40℃ linearly to 70% at 50℃

Avg. Efficiency

See rating chart

Setup up / Hold up / Rise time

Typical: 3000mS / 16mS / 50mS at full load.

Line regulation

±1% maximum for any input voltage change between input voltage range

Load regulation

Typical±5% variations from minimum to maximum output current. Or see rating chart

Insulation resistance

50Mohn minimum from input to output

Inrush current

20 AMPS@115 VAC ; 40AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

CE

Safety requirements

Reference design: (A)UL60950-1;CSA C22.2 (B)EN60950-1 ; IEC60950-1

Warranty

1 year

Dimension(mm)

72x62x28

Weight(g)

70g <58>


LEO15

for LED power series

Mechanical Specification

72 3.5

3.5 3.5

UNIT: mm 3.5

3.5

DANGER

HIGH VOL TAGE

3.5

62

CN1

CN2

123

12

3.5 3.5

28 23 1.6

3.4

AC input connector (CN1): Molex5273 series or equivalent Pin number Assignment Mating Housing 1

AC-l

2

N.C.

3

AC-N

Terminal

Molex5058 or equivalent

Molex2478 or equivalent

DC output connector (CN2): Molex5273 series or equivalent Pin number Assignment Mating Housing

Terminal

-v +v

Molex5194 or equivalent

1 2

Molex5195 or equivalent

Output

Output

Max .Output

Ripple(mV)

Line

Load

Voltage(VDC)

Current (A)

Power (W)

Max.

Regulation (%)

Regulation (%)

LEO15-1

5~6

2.40~2.00

12

50

1

±10

LEO15-2

8~11

1.80~1.36

15

80

1

±5

76

LEO15-3

11~13

1.36~1.15

15

100

1

±5

76

LEO15-4

13~16

1.15~0.94

15

120

1

±3

76

LEO15-5

16~21

0.94~0.72

15

120

1

±3

77

LEO15-6

21~27

0.72~0.55

15

150

1

±3

78

LEO15-7

27~33

0.55~0.45

15

240

1

±2

80

LEO15-8

33~48

0.45~0.31

15

240

1

±2

80

Model name

↑ <59>

EFF (%) 65


LEO40 for LED power series z z z z z z z z z z

Universal input voltage Single output Short circuit protection High input power factor Over voltage protection Over current protection Optional output voltage adjustable function Built-in constant current limiting with Adj. OCP level Built-in low input voltage cut off function Low input ATHD One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

LEO40 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

1A Max.

Input power factor

≧0.9 at 75~100% load

Input total harmonic distortion

<20% at 75~100% load

Low input cut off voltage

<70VAC +10/-20AC

Leakage current

<0.7mA

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes

Over current protection

Yes

Short protection

Yes

Temperature coefficient

All output±0.04%/℃ maximum

Operating temperature

-20℃~+40℃

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at+40℃ linearly to 50% at 70℃

Efficiency

See rating chart

Hold-up time

No hold-up time

Line regulation

±2% maximum for any input voltage change between input voltage range

Load regulation

±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

40 AMPS@115 VAC;80AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)EN55022 class B (B) FCC PART 15 B

Safety requirements

Design refer: UL1012 ; EN61347-1 EN61347-2-13

Warranty

1 year

Dimension(mm)

163.5x54x25

Weight(g)

160g <60>


LEO40 for LED power series Mechanical Specification

Type1: AC input connector (CN1): Molex5273 series or equivalent Pin number Assignment Mating Housing 1 AC-L Molex5058 2 N.C. or equivalent 3 AC-N

Terminal Molex2478 or equivalent

DC output connector (CN2): Molex5273 series or equivalent Pin number Assignment Mating Housing Terminal 1 +v Molex5058 Molex2478 2 +v or equivalent or equivalent 3 -v 4 -v Type2: AC input connector (CN1): DINKLE EV508V-02P Solid wire(AWG) Pin number Assignment Stranded wire (AWG / mm2) 1 AC-L 24~12 24~12 2 AC-N DC output connector (CN2): DINKLE EV508V-02P Pin number

Assignment

2 3

+V -V

Solid wire(AWG) Stranded wire (AWG / mm2) 24~12 24~12

X=A (Class 1) or B (Class 2) Y=V→Output voltage adjustable A→Constant current level adjustable R→Output voltage and constant current level adjustable Model name

Output Voltage(VDC)

Output Current(A)

Max. Power(W)

EFF(%)

Ripple(V)

LEO40X-2-Y LEO40X-3-Y LEO40X-4-Y LEO40X-5-Y LEO40X-6-Y LEO40X-7-Y LEO40X-8-Y LEO40X-9-Y

8~11V 11~13V 13~16V 16~21V 21~27V 27~33V 33~40V 40~50V

4.38~3.19A 3.64~3.08A 2.67~2.50A 2.50~1.91A 1.91~1.49A 1.49~1.22A 1.22~1.00A 1.00~0.84A

35 40 40 40 40 40 40 40

76 80 82 82 82 82 82 82

2.5 3 3 3.5 3.5 3.5 3.5 3.5

↑ <61>


LE41 z z z z z z z z z z

for LED power series

Universal input voltage Single output Short circuit protection High input power factor (Active PFC) Over voltage protection Over current protection Output voltage and current adjustable function Constant voltage and current design Low input ATHD One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

LE41 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

1A Max.

Input power factor

≧0.9 at 75~100% load

Input total harmonic distortion

<20% at 75~100% load

Leakage current

<0.7mA

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes

Over current protection

Yes

Short protection

Yes

Temperature coefficient

All output±0.04%/℃ maximum

Operating temperature

-20℃~+40℃

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at+40℃ linearly to 50% at 70℃

Efficiency

See rating chart

Hold-up time

No hold-up time

Line regulation

±2% maximum for any input voltage change between input voltage range

Load regulation

±10% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

40 AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)EN55015 class B (B) EN55022 class B (C)FCC PART 15 B

Safety requirements

Design refer: EN61347-1 ; EN61347-2-13 ; EN60950-1(CCN FKSZ2/8) ; UL8750

Warranty

1 year

Dimension(mm)

236x45.8x30

Weight(g)

375g <62>


LE41 for LED power series Mechanical Specification

UNIT: mm

Type1: AC input connector (CN1): DECA MB310-750M03 series or equivalent Solid wire(AWG) Pin number Assignment Stranded wire (AWG / mm2) 1 AC-L 26~12AWG 2 AC-N 3 AC-FG DC output connector (CN2): DECA MB310-750M02 series or equivalent Solid wire(AWG) Pin number Assignment Stranded wire (AWG / mm2) 1 V2 V26~12AGW 3 V+ 4 V+ Type2: AC input connector (CN1): DINKLE 144RA-02P Solid wire(AWG) Pin number Assignment Stranded wire (AWG / mm2) 1 AC-L 24~12 24~12 2 AC-N DC output connector (CN2): DINKLE 144RA-04P Pin number

Assignment

1 2 3 4

VVV+ V+

Solid wire(AWG) Stranded wire (AWG / mm2) 24~12 24~12 24~12 24~12

X=A (Class 1) or B (Class 2) Model name

Output Voltage(VDC)

Output Current(A)

Max. Power(W)

EFF(%)

Ripple(V)

LE41X-3 LE41X-4 LE41X-5 LE41X-6 LE41X-7 LE41X-8 LE41X-9

11~13V 13~16V 16~21V 21~27V 27~33V 33~40V 40~50V

3.64~3.08A 2.67~2.50A 2.50~1.91A 1.91~1.49A 1.49~1.22A 1.22~1.00A 1.00~0.84A

40 40 40 40 40 40 40

80 82 82 82 82 82 82

3 3 3.5 3.5 3.5 3.5 3.5

↑

<63>


LE61 z z z z z z z z z z

for LED power series

Universal input voltage Single output Short circuit protection High input power factor (Active PFC) Over voltage protection Over current protection Output voltage and current adjustable function Constant voltage and current design Low input ATHD One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications:

LE61 series:

Input voltage

100~240VAC

Input frequency

50~60Hz

Input current

1.2A Max.

Input power factor

≧0.9 at 75~100% load

Input total harmonic distortion

<20% at 75~100% load

Leakage current

<0.7mA

Output voltage

See rating chart

Output current

See rating chart

Output power range

See rating chart

Ripple

See rating chart

Over voltage protection

Yes

Over current protection

Yes

Short protection

Yes

Temperature coefficient

All output±0.04%/℃ maximum

Operating temperature

-20℃~+40℃

Storage temperature

-40℃~+85℃

Relative humidity

5% to 95% non-condensing

Derating

Derated from 100% at+40℃ linearly to 50% at 70℃

Efficiency

See rating chart

Hold-up time

No hold-up time

Line regulation

±2% maximum for any input voltage change between input voltage range

Load regulation

±5% variations from minimum to maximum output current.

Insulation resistance

50Mohm minimum from input to output

Inrush current

40 AMPS@115 VAC;80AMPS @ 230VAC at 25℃ cold start

Withstand voltage

4242VDC from input to output

Mean time between failure

100,000 hours minimum at full load at 25℃ ambient

EMI requirements

(A)EN55015 class B (B) EN55022 class B (C)FCC PART 15 B

Safety requirements

Design refer: EN61347-1 ; EN61347-2-13 ; EN60950-1(CCN FKSZ2/8) ; UL8750

Warranty

1 year

Dimension(mm)

246x45.8x30

Weight(g)

452g <64>


LE61 for LED power series Mechanical Specification

UNIT: mm

Type1: AC input connector (CN2): DECA MB310-750M03 series or equivalent Solid wire(AWG) Pin number Assignment Stranded wire (AWG / mm2) 1 AC-L 26~12AWG 2 AC-N 3 AC-FG DC output connector (CN1): DECA MB310-750M02 series or equivalent Solid wire(AWG) Pin number Assignment Stranded wire (AWG / mm2) 1 N.C. 2 V26~12AWG 3 V+ 4 N.C. Type2: AC input connector (CN2): DINKLE 144RA-02P Solid wire(AWG) Pin number Assignment Stranded wire (AWG / mm2) 1 AC-L 24~12 24~12 2 AC-N DC output connector (CN1): DINKLE 144RA-04P Pin number

Assignment

1 2 3 4

VVV+ V+

Solid wire(AWG) Stranded wire (AWG / mm2) 24~12 24~12 24~12 24~12

X=A (Class 1) or B (Class 2) Model name

Output Voltage(VDC)

Output Current(A)

Max. Power(W)

Efficiency(%)(min)

Ripple(mV)

LE61X-3 LE61X-4 LE61X-5 LE61X-6 LE61X-7 LE61X-8 LE61X-9

11~13V 13~16V 16~21V 21~27V 27~33V 33~40V 40~50V

5A MAX 4.61~3.75A 3.75~2.86A 2.86~2.23A 2.23~1.82A 1.82~1.50A 1.50~1.20A

60 60 60 60 60 60 60

78 78 78 80 80 82 82

180 180 200 200 240 260 300

↑

<65>


GUSB05

5VDC @ 1.0A USB Charger

(ENERGY STAR V)

Plug-in power supply

Features: z z z z z z

Universal input voltage Meet ENERGY STAR V Standard USB (Type A) connector Short circuit protection Over voltage protection Over temperature protection

SAFETY AGENCY APPROVALS:

Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection Short protection Over temperature protection Operation temperature Storage temperature Relative humidity Derating Efficiency Hold-up time Line regulation Load regulation Insulation resistance Inrush current Withstand voltage Mean time between failure EMI requirements Safety requirements Warranty Weight

GUSB05 100~240VAC 47~63Hz 0.15A Max. 0.25mA Max.@264VAC/50Hz 5V 1A 5W 80m Vp-p Yes. Yes. Yes. U1 Tj<142℃ 0℃~+40℃ -40℃~+85℃ 5% to 95% non-condensing Derated from 100% at+40°C linearly to 50% at 70°C 68.17% min 10m/sec minimum ±1% maximum for any input voltage change between input voltage range ±5% variations from minimum to maximum output current 50Mohm minimum from input to output 35 AMPS @ 230VAC at 25℃ cold start 4242VDC from input to output 50,000 hours minimum at full load at 25℃ ambient FCC UL60950-1 ; CSA C22.2 1year 26g <66>


GUSB05E

(ENERGY STAR V)

5VDC @ 1.0A USB Charger

Plug-in power supply

Features: z z z z z z z

Universal input voltage Meet Energy star V Standard USB (Type A)connector Short circuit protection Over voltage protection Over temperature protection One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection Short protection Over temperature protection Operation temperature Storage temperature Relative humidity Derating Efficiency Hold-up time Line regulation Load regulation Insulation resistance Inrush current Withstand voltage Mean time between failure EMI requirements Safety requirements Warranty Weight

GUSB05E 100~240VAC 50~60Hz 0.15A Max. 0.25mA Max.@264VAC/50Hz 5V 1A 5W 120m Vp-p Yes. Yes. Yes. U1 Tj<142℃ 0℃~+40℃ -40℃~+85℃ 5% to 95% non-condensing Derated from 100% at+40°C linearly to 50% at 70°C 68.17% min 10m/sec minimum ±1% maximum for any input voltage change between input voltage range ±5% variations from minimum to maximum output current 50Mohm minimum from input to output 35 AMPS @ 230VAC at 25℃ cold start 4242VDC from input to output 50,000 hours minimum at full load at 25℃ ambient CE: (EN55022; class B) (EN55024) EN60950-1 1year 32g <67>


GUSB12

(ENERGY STAR V)

5VDC @ 2.1A USB Charger

Plug-in power supply

Features: z z z z z z z z

Universal input voltage Meet ENERGY STAR V Standard USB (Type A)connector Option D+/D- define Short circuit protection Over voltage protection Over temperature protection One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection Short protection Operation temperature Storage temperature Relative humidity Avg.Efficiency Hold-up time Line regulation Load regulation Insulation resistance Inrush current Withstand voltage Mean time between failure EMI requirements Safety requirements Warranty Weight

GUSB12 100~240VAC 50~60Hz 0.3A Max. 0.25mA Max.@264VAC/50Hz 5V 2.1A 10.5W 160mVp-p MAX. At Vin:115VAC/60Hz ; 230VAC/50Hz Yes. Yes. Yes. 0℃~+40℃ -40℃~+85℃ 5% to 95% non-condensing 73.75% min 8m/sec minimum ±1% maximum for any input voltage change between input voltage range ±5% variations from minimum to maximum output current 50Mohm minimum from input to output 50 AMPS @ 115VAC at 25℃ cold start 4242VDC from input to output 50,000 hours minimum at full load at 25℃ ambient Meet LVD CE(EN55022 ; EN55024) ; FCC(FCC 47 CFR Part 15) Reference design to UL60950-1 ; CSA C22.2 1year 60g <68>


GUSB12E

(ENERGY STAR V)

5VDC @ 2.1A USB Charger

Plug-in power supply

Features: z z z z z z z z

Universal input voltage Meet ENERGY STAR V Standard USB (Type A)connector Option D+/D- define Short circuit protection Over voltage protection Over temperature protection One year limited warranty

SAFETY AGENCY APPROVALS:

USB Type A -

+ 4

Specifications: Input voltage Input frequency Input current Leakage current Output voltage Output current Output power range Ripple Over voltage protection Over current protection Short protection Operation temperature Storage temperature Relative humidity Avg.Efficiency Hold-up time Line regulation Load regulation Insulation resistance Inrush current Withstand voltage Mean time between failure EMI requirements Safety requirements Warranty Weight

GUSB12E 100~240VAC 50~60Hz 0.3A Max. 0.25mA Max.@264VAC/50Hz 5V 2.1A 10.5W 160mVp-p MAX. At Vin:115VAC/60Hz ; 230VAC/50Hz Yes. Yes. Yes. 0℃~+40℃ -40℃~+85℃ 5% to 95% non-condensing 73.75% min 8m/sec minimum ±1% maximum for any input voltage change between input voltage range ±5% variations from minimum to maximum output current 50Mohm minimum from input to output 50 AMPS @ 230VAC at 25℃ cold start 4242VDC from input to output 50,000 hours minimum at full load at 25℃ ambient CE(EN55022 ; EN55024) ; FCC(FCC 47 CFR Part 15) Meet LVD Reference design to UL60950-1 ; CSA C22.2 ; EN60950-1 1year 65g <69>

3

2 1


PSD03 5V/500mA USB DC TO DC series In car power supply (DC TO DC) Features: z Input voltage 11VDC to 28VDC z z

z z z z

Standard USB (Type A)connector Option D+/D- define

High reliability High efficiency Compact package One year limited warranty

SAFETY AGENCY APPROVALS:

Specifications: Input voltage Input current Input Protection Output voltage Output current Output power range Ripple Over voltage protection Over current protection Operation temperature Short protection Storage temperature Relative humidity Efficiency Load regulation Mean time between failure EMC requirements Warranty Weight

UNT: mm

PSD03 11 ~ 28VDC(Max. 32VDC) 0.35A Max. By 1.0A fuse 5V 500mA 2.5W 280mVp-p 20MHz band width. At Vin: 24VDC Yes. Yes. 0.85A Max. Output voltage drop. 0℃~+45℃ Yes. -40℃~+85℃ 5% to 95% non-condensing 70% min ±5% variations from minimum to maximum output current 100,000 hours minimum at full load at 25℃ ambient CISPR 25 1year 32g <70>


PSD18 18W DC TO DC series

(ISOLATED)

In car power supply (DC TO DC) Features: z Wide input voltage 36VDC to 72VDC z

Optional input and output connectors

z

High reliability

z

High efficiency

z

Compact package

z

One year limited warranty

UNIT: mm

Model name PSD18-1-I PSD18-1-1-I PSD18-2-I PSD18-3-I PSD18-4-I PSD18-5-I PSD18-6-I PSD18-7-I

Output Voltage(VDC)

Output Current(A)

Maximum Output Power (W)

5~6 VDC 6~8 VDC 8~11 VDC 11~13 VDC 13~16 VDC 16~21 VDC 21~27 VDC 27~33 VDC

3.00~2.50A 2.50~1.88A 2.25~1.64A 1.64~1.38A 1.38~1.13A 1.13~0.86A 0.86~0.67A 0.67~0.55A

15W 15W 18W 18W 18W 18W 18W 18W

Note: 1. Weight: Approx 150~250g 2. Optional output connectors (see page 81)

<71>

↑


PSD25 18W DC TO DC series

(ISOLATED)

In car power supply (DC TO DC) Features: z Wide input voltage 11VDC to 26VDC z

Optional input and output connectors

z

High reliability

z

High efficiency

z

Compact package

z

One year limited warranty

Model name PSD25-0-I PSD25-1-I PSD25-1-1-I PSD25-2-I PSD25-3-I PSD25-4-I PSD25-5-I PSD25-6-I PSD25-7-I PSD25-8-I

Output Voltage(VDC) 3~5 VDC 5~6 VDC 6~8 VDC 8~11 VDC 11~13 VDC 13~16 VDC 16~21 VDC 21~27 VDC 27~33 VDC 33~48 VDC

UNIT: mm

Output Current(A) 3.33~2.00A 2.70~2.25A 2.40~1.80A 2.13~1.55A 1.55~1.38A 1.38~1.12A 1.12~0.85A 0.85~0.66A 0.66~0.54A 0.54~0.37A

Note: 1. Weight: Approx 150~250g 2. Optional output connectors (see page 81)

<72>

↑

Maximum Output Power (W) 10W 13.5W 14.4W 17.1W 18W 18W 18W 18W 18W 18W


PSD40 36W DC TO DC series

(ISOLATED)

In car power supply (DC TO DC) Features: z Wide input voltage 11VDC to 26VDC z

Optional input and output connectors

z

High reliability

z

High efficiency

z

Compact package

z

One year limited warranty UNIT: mm

Model name PSD40-0-I PSD40-1-I PSD40-1-1-I PSD40-2-I PSD40-3-I PSD40-4-I PSD40-5-I PSD40-6-I PSD40-7-I PSD40-8-I

Output Voltage(VDC)

Output Current(A)

Maximum Output Power (W)

3~5 VDC 5~6 VDC 6~8 VDC 8~11 VDC 11~13 VDC 13~16 VDC 16~21 VDC 21~27 VDC 27~33 VDC 33~48 VDC

5.00~3.00A 4.50~3.75A 5.00~3.75A 4.27~3.10A 3.27~2.76A 2.76~2.25A 2.25~1.71A 1.71~1.33A 1.33~1.09A 0.75~0.75A

15W 22.5W 30W 34.2W 36W 36W 36W 36W 36W 36W

Note: 1. Weight: Approx 200~250g 2. Optional output connectors (see page 81)

<73>

↑


PSD12 8W DC TO DC series

(NON-ISOLATED)

In car power supply (DC TO DC) Features: z Input voltage 11VDC to 15VDC z

Optional input and output connectors

z

High reliability

z

High efficiency

z

Compact package

z

One year limited warranty

Model name PSD12-1 PSD12-1-1 PSD12-2 PSD12-4 PSD12-5 PSD12-6 PSD12-7 PSD12-8

Output Voltage(VDC)

Output Current(A)

Maximum Output Power (W)

5~6 VDC 6~8 VDC 8~10 VDC 13~16 VDC 16~21 VDC 21~27 VDC 27~33 VDC 33~48 VDC

1.00~0.83A 1.00~0.75A 1.00~0.72A 0.61~0.50A 0.50~0.38A 0.38~0.29A 0.29~0.24A 0.24~0.16A

5W 6W 8W 8W 8W 8W 8W 8W

Note: 1. Weight: Approx70~100g 2. Optional output connectors (see page 81)

<74>

↑


PSD25 25W DC TO DC series

(NON-ISOLATED)

In car power supply (DC TO DC) Features: z Wide input voltage 11VDC to 26VDC for Model PSD25-0 to PSD25-2 z

Input voltage 11VDC to 15VDC for Model PSD25-5 to PSD25-8

z

Optional input and output connectors

z

High reliability

z

High efficiency

z

Compact package

z

One year limited warranty

Model name PSD25-1 PSD25-1-1 PSD25-2 PSD25-4 PSD25-5 PSD25-6 PSD25-7 PSD25-8

UNIT: mm

Output Voltage(VDC)

Output Current(A)

Maximum Output Power (W)

5~6 VDC 6~8 VDC 8~11 VDC 13~16 VDC 16~21 VDC 21~27 VDC 27~33 VDC 33~48 VDC

3.6~3.0A 3.0~2.2A 2.5~1.8A 1.5~1.2A 1.2~0.9A 1.1~0.9A 0.9~0.7A 0.7~0.5A

18W 18W 20W 20W 20W 25W 25W 25W

Note: 1. Weight: Approx200~250g 2. Optional output connectors (see page 81)

<75>

↑


PSD40 40W DC TO DC series

(NON-ISOLATED)

In car power supply (DC TO DC) Features: z Wide input voltage 11VDC to 26VDC for Model PSD40-0 to PSD40-2 z

Input voltage 11VDC to 15VDC for Model PSD40-5 to PSD40-8

z

Optional input and output connectors

z

High reliability

z

High efficiency

z

Compact package

z

One year limited warranty

Model name PSD40-1 PSD40-1-1 PSD40-2 PSD40-4 PSD40-5 PSD40-6 PSD40-7 PSD40-8

UNIT: mm

Output Voltage(VDC)

Output Current(A)

Maximum Output Power (W)

5~6 VDC 6~8 VDC 8~11 VDC 13~16 VDC 16~21 VDC 21~27 VDC 27~33 VDC 33~48 VDC

5.0~4.1A 5.0~3.7A 4.3~3.1A 2.9~2.3A 2.5~1.9A 1.6~1.4A 1.4~1.2A 1.2~0.8A

25W 30W 35W 38W 40W 40W 40W 40W

Note: 1. Weight: Approx200~250g 2. Optional output connectors (see page 81)

<76>

↑


PSD60 60W DC TO DC Series

(NON-ISOLATED)

In car power supply (DC TO DC) Features: z Input voltage 11VDC to 15VDC z

Optional input and output connectors

z

High reliability

z

High efficiency

z

Compact package

z

One year limited warranty NIT: mm

Model name

Output Voltage(VDC)

Output Current(A)

Maximum Output Power (W)

PSD60-5

18~21 VDC

3.34~2.86A

60W

PSD60-6

21~27 VDC

2.86~2.22A

60W

PSD60-7

27~33 VDC

2.22~1.81A

60W

Note: 1. Weight: Approx200~250g 2. Optional output connectors (see page 81)

<77>

↑


EJ13-123 In Car Power Extension Adapter With USB series In car power extension series Features: z Input voltage 12-24VDC z

z

Dual Standard USB (Type A)connectors

One year limited warranty

20

UNT: mm (0°-90°)

123.5 83.8

35.6

93.5

21

Specifications: Input voltage Input current

EJ13-123

12 ~ 24VDC 10A Max.(With 10A glass tube fuse) 1A Max. when using 1 port only USB Output 0.5A Max. each port when using 2 ports Housing: ABS(UL94-HB) Material of socket Inner contact: Nickel plated brass. Contact: Nickel plated metal. Housing: Phenolic (UL94V-1) Material of plug Top contact: Nickel plated brass Contact: Nickel plated metal. Dielectric strength 1000VAC / 1minule Insulation resistance 500VDC / 100MΩ Plug / Twin outlet sockets Twin outlet sockets with 0 ~ 90 degree. 4-positions adjustable plug USB Port Dual USB (Type A) USB sockets for charging mobile phones ; MP3 players & PDA’s Re-mark: Unavailable in UK market. <78>


EJ13-149 In Car Power Extension Adapter With USB series In car power extension series Features: z Input voltage 12VDC(Max. 14VDC) z

z z z

Standard USB (Type A) connector Indicating different level of battery power Green LED light ring around sockets for night time use

One year limited warranty

UNT: mm 78.8 HIGH

MID

12V

LOW

42

120

Specifications: Input voltage Input current USB Output

EJ13-149

12VDC 10A Max. (With 10A glass tube fuse) 1A Max. Housing: ABS(UL94-HB) Material of socket Inner contact: Nickel plated brass. Contact: Nickel plated metal. W/extension cable ψ21mm Battery analyzer featured By 4 LED’s Dielectric strength 1000VAC / 1minule Insulation resistance 500VDC / 100MΩ Sockets LED light Green LED light ring around sockets USB Port USB sockets for charging mobile phones ; MP3 players and PDA’s Re-mark: Unavailable in UK market.

Battery analyzer features BATTERY CHECKER

TURN OFF ENGINE OFF FOR

START ENGINE FEW MINUTES

SITUATION

MINUTES

FOR

Low ●

12V ●

MID ●

HIGH ●

FOR BATTERY CAPCITY CHECK

CHARGING SYSTEM CHECK

Very good

Very good

Normal

Normal

Weak

Charging system is possibly abnormal Charging system is possibly abnormal Check your charging system

Too much discharge (The battery needs to be charged)

No capacity (Voltage is under 3V, replace battery)

NOTE: THE ABOVE READINGS WOULD BE AFFECTED BY THE TEMPERATURE AND CAR USED CONDITION <79>


EJ13-175B In Car Power Extension Adapter With USB series In car power extension series Features: z Input voltage 12VDC z z

z

Dual Standard USB (Type A)connectors Flexible neck for multi-positioning

One year limited warranty

UNT: mm 7.5

20

13.3

182.7

22.0

14.4

84

40.3

Specifications: Input voltage Input current

EJ13-175B

12 VDC 10A Max.(With 10A glass tube fuse) 2A Max. when using 1 port only USB Output 1A Max. each port when using 2 ports Housing: ABS(UL94-HB) Material of socket Inner contact: Nickel plated brass. Contact: Nickel plated metal. Housing: PBT (UL94-HB)) Material of plug Top contact: Nickel plated brass Spring contact: Nickel plated spring steel. Plug Flexible neck for multi-positioning Dielectric strength 1000VAC / 1minule Insulation resistance 500VDC / 100Mâ„Ś Dual USB (Type A) USB sockets for charging mobile phones ; MP3 players and USB Port other devices Re-mark: Unavailable in UK market. <80>

↑


CONNECTOR (DC PLUG) LIST

<81>


ORDERING FORM


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.