Magnetic LED Retrofit Kit
Features ◆ DLC ETL listed;
Applica on:
◆ AC100-240V, Ra>80
• Workshop
◆ SMD2835 LED; High efficacy 130lm/w
• Factory
◆ High rebates, low import tariffs ◆ External driver
• Office • Shopping mall • supermarket
◆ Simple and secure installa on, comes with quick connects for easy install ◆ An energy efficient replacement for exis ng T12 and T8 strip fixtures and troffers ◆ 5 years warranty ◆ Opera ng temperature: -20℃~45℃
CM
LED driver 1-10V Dim AC100-240V
Length 2FT 25W (2 strips driven by one driver) 4FT 36W 50W (2 strips driven by one driver) 4FT 60W (3 strips driven by one driver) 4FT 60W (4 strips driven by one driver)
Connec on Male and female connec on
Magnet 1mm thickness magnet; High Impact Resistance; Rustless; Easy to install Minimized the labor costs
Parameters EďŹƒcacy
Size
Power
2FT
25W
3250LM
T8RTP36W4FT*2
36W
4680LM
T8RTP50W4FT*2
50W
Model # T8RTP25W2FT*2
130LM/W
Lumen
6500LM
4FT T8RTP60W4FT*3
60W
7800LM
T8RTP60W4FT*4
60W
7800LM
Driver
Mul ple Driving Type
External
2 strips driven by one driver 2 strips driven by one driver 2 strips driven by one driver 3 strips driven by one driver 4 strips driven by one driver
Wire Input
CCT
One
4000K
eco2LIGHT A/S - Gørtlervej 21, 9000 Aalborg - Tel. 7070 1555 - www.eco2light.dk
end
Accessories
PC Cover
Male and Female connector
17,5 mm
Dimension 50 cm
110 cm
32 mm
Installa on ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
Fig. 1
Step 1:
Fig. 2
Step 2:
Cut off the power of the troffer
Take out the fluorescent
retrofit kit before any operation
tubes one by one.
Pull the movable bolt at the edge of the troffer retrofit kit and open the cover.
eco2LIGHT A/S - Gørtlervej 21, 9000 Aalborg - Tel. 7070 1555 - www.eco2light.dk
Fig. 3
Step 3:
Step 4:
Fig. 4
Dismantle the ballast and
Open the top cover of wiring box.
circuit of the fluorescent tubes .
Fig.5
Step 5:
Step 6:
Fig. 6
Take out the LED driver and
A. Take out the LED Magnet Tubes
screws we provide; ďŹ x the drivers
from the package box. B. Stick the LED
onto the position of the previous
Tubes onto the troffer. Adjust its position
ballast.
to make sure they are placed horizontally in proper position.
Fig. 7
Step 7:
Step 8:
Fig. 8
Connect the Connection Wire to the
Connection mode of LED Driver' s
OUTPUT terminal of the LED driver.
Input Wire(See Fig. 7): White: Live Wire Black: Null Wire Yellow/Green: Ground Wire
Fig. 9
Step 10:
Fig. 10
Finish all connection between
Step 9:
LED driver and. LED strips.
Connect the Connection Wire
to the LED Tubes through 2P socket one by one.
Fig. 11
Step 11: Install the top cover of the wiring box to cover the LED driver.
Fig. 12
Step 12: Pull the movable bolt at the edge of the troffer retrofit kit and close the cover slightly.