Leca LWA

Page 3

Geotechnical

3

Grading

Thermal Conductivity

Leca® LWA is produced in the form of round ceramic granules with a porous cellular

The practical thermal conductivity may vary from 0.10 to 0.15W/mK depending

inner structure. The grading for most Geotechnical applications is 10-20mm.

on grading, compaction, humidity level and type of technical application.

Density

Durability

Leca® LWA 10-20mm dry density ranges between 220kg/m3 – 325kg/m3.

Leca® LWA is totally inert; it contains no harmful substances or gases and is completely neutral. Leca® LWA’s resistance to chemical attack is comparable to

Resistance

that of glazed tile, glass or other ceramic material.

Unlike other granular loose material Leca® LWA offers a frictional resistance without any cohesion. The 10-20mmR grade has an internal angle of friction of typically 37° (standard shear box tested) and a design strength of 100kN/m² due to the rigidity of the rounded pellet.