Locking and Security Electronic Locking System Locking and Security Electronic Locking System Technical data
Wall reader
Protection class
IP65
Ambient temperature (operation)
-20 – +70ºC
Power supply
Via electronic control unit 2
Connection screw terminals mm
1.0
Protection class
IP20
Ambient temperature (operation)
-20 – +70ºC
Power supply
9–40 V DC or 8–36 V AC
Current input Electronic control unit
Contact rating of relays
Max. continuous current intake mA
150
Max. peak current use mA
300
Max. voltage
60 V DC or 125 V AC
Max. switching current (short-term) A
2.0
Max. switching capacity
30 W or 60 VA
Max. continous current A
1.0
Min. data storage in the event of a powerfailure years
10
Relative humidity (non-condensating)
0–95%
2
We reserve the right to alter specifications without notice (HIN Architectural Hardware 2015).
We reserve the right to alter specifications without notice (SEA Architectural Hardware 2015).
Connection screw terminals mm
2 2
2.5
Technical reference • Connection between wall reader and electronic control with four core installation cable in compliance with VDE 0815: Type J-Y (St) Y2x2x0.8 mm (twisted pair, shielded), max. length 35 m • Please contact our Dialock specialist for other lengths • Installation of wall readers in flush mounted box with 2 device fastening screws in 15 mm distance (60 mm in compliance with DIN) • Make sure the fastening points on the flush box are horizontal • Minimum distance between 2 wall readers should be 250 mm • Installation of wall reader in metal surroundings must be planned • Programming during standalone operation is not possible • Planning by Dialock specialist is required • EFL 3, EFL 6, FLC furniture locks can be connected to the MLA 8 • MLA 8R with relay output ports is usable for any electrical load,e.g. elevator
New products and systems: www.hafele.com
New products and systems www.hafeleindia.com
AH
2.159 AH
2.93