nivelco-catalogue-2018-1-media-m

Page 193

PR ES SU R E TR A N SM I T TERS NIPRESS D-300

N I PR ES S D 3 years

2- /3-wire mini compact pressure transmitter for absolute and gauge pressure measurement Output: 4-20 mA or 0-10 V, Diaphragm: stainless steel, Measurement range: -1-600 bar

Measuring method

D

R E

n – 3 nn – n

Gauge Absolute (p ≥ 0.4 bar)

Process connection

Dn

A C G H J

– 3 nn – n

DRo-3oo, DEo-3oo P=<40 bar

1/4” BSP 1/2” BSP 1/4” NPT (max. 40 bar) 1/2” NPT M20x1.5

Range / Overpressure*

Dnn – 3

n – n 0 -1-0 bar / 5 bar 1 0-0.1 bar / 0.5 bar R 0-0.16 bar / 1 bar 2 0-0.25 bar / 1 bar 3 0-0.4 bar / 2 bar 4 0-0.6 bar / 5 bar 5 0-1 bar / 5 bar 6 0-1.6 bar / 10 bar 7 0-2.5 bar / 10 bar 8 0-4 bar / 20 bar 9 0-6 bar / 40 bar A 0-10 bar / 40 bar B 0-16 bar / 80 bar C 0-25 bar / 80 bar D 0-40 bar / 105 bar E 0-60 bar / 210 bar F 0-100 bar / 600 bar G 0-160 bar / 600 bar H 0-250 bar / 1000 bar J 0-400 bar / 1000 bar K 0-600 bar / 1000 bar * Custom measuring range, based on prior negotiations.

Accuracy

Dnn – 3 n

1 2 4

– n

DRo-3oo, DEo-3oo P=>40 bar

0.25% (p ≥ 0.4 bar) 0.5% 0.1% (not in combination with SIL)

Output / Approval

Dnn – 3 nn –

PRESSURE

2 4-20 mA 3 0-10 V 6 ** 4-20 mA / Ex ia C ** 4-20 mA, SIL2 D ** 4-20 mA, SIL2 / Ex ia ** Ex or SIL versions are available on special request.

Available on request (should be given in the text of the order) EPDM, FKM, NBR sealing M12x1 (4-pin) IP67 electronic connection, metal Integrated cable version (IP68), PVC cable

Accessories to order*** P L K – 5 0 1 – 2 P L K – 5 0 1 – 3

PLK-501

Plug-in indicator Plug-in indicator with PNP output

*** Only for 2-wire version

NIV24 DRC-3A2-2 DRC-3B2-2

193