CONSTRUCTION DOCUMENTS
006 CODE ANALYSIS
I.
AUTHORITIES A. City of Knoxville Fire Inspection Bureau B. City of Knoxville Plans, Reviews & Inspections Bureau
II.
APPLICABLE BUILDING CODES A. BUILDING/DWELLING CODE B. PLUMBING CODE C. MECHANICAL CODE D. ELECTRICAL CODE E. FIRE CODE F. GAS CODE G. ENERGY CODE H. LIFE SAFETY CODE I. AMERICANS W/ DISABILITY ACT
IV.
V.
BUILDING FEATURES A. TYPE OF CONSTRUCTION B. BUILDING HEIGHT C. NO. OF STORIES D. BUILDING AREA E. NO. OF EXITS PER FLOOR
OCCUPANT LOAD
D.
FIXTURE REQUIREMENTS 1. WATER CLOSETS 2. LAVATORIES 3. DRINKING FOUNTAINS
BUSINESS, GROUP B 3RD FLOOR 10,396 SQ. FT. 4TH FLOOR 3,775 SQ. FT 3RD FLOOR 1 PERSON / 100 S.F. = 103 PERSONS 4TH FLOOR 1 PERSON / 100 S.F. = 37 PERSONS 1/50 (3 REQ’D) 1/40 (4 REQ’D) 1/100 (2 REQ’D)
MEANS OF EGRESS REQUIREMENTS A. MAXIMUM TRAVEL DISTANCE TO EXIT B. MAXIMUM DEAD END CORRIDOR C. COMMON PATH OF TRAVEL D. MAXIMUM EXIT SEPARATION E. F. G. H.
VI
TYPE II B, UNPROTECTED, SPRINKLED N/A 6 91,426 sf 2
OCCUPANCY INFORMATION A. CLASSIFICATION B. CONSTRUCTION AREAS C.
MAXIMUM DIAGONAL DISTANCE MINIMUM CORRIDOR WIDTH (per code) MINIMUM QTY OF EXITS FROM SUITE MINIMUM EGRESS WIDTH 1. 3RD FLOOR 2. 4TH FLOOR 3. STAIRS
300’ (SPRINKLED) 50’ (SPRINKLED) 100’ (SPRINKLED) 58’ (SPRINKLED) (175’ X 0.3) 1/3 DIAGONAL OF SPACE 175' 44" 2 @ 3RD FLOOR (> 49 OCCUPANTS) 1 @ 4TH FLOOR (< 49 OCCUPANTS)
EXIT ACCESS + OTHER SPACES
VII. FIRE PROTECTION REQUIREMENTS A. FIRE EXTINGUISHER REQUIREMENTS B. MAX TRAVEL DISTANCE TO EXTINGUISHER C. MANUAL FIRE ALARM BOXES
General Project Information 3rd Floor Construction Plan 3rd Floor Dimension Plan 4th Floor Construction Plan 4th Floor Dimension Plan 3rd Floor Reflected Ceiling Plan 4th Floor Reflected Ceiling Plan 3rd Floor Finish Plan 4th Floor Finish Plan 3rd Floor Power + Communication Plan 4th Floor Power + Communication Plan 3rd Floor Furniture Plan 4th Floor Furniture Plan Elevations Elevations Sections Partition Types Partition Types Millwork Details Millwork Details Ceiling Details Ceiling Details Stair Sections + Details Stair Sections + Details Door Elevations 3rd Floor Life Safety 4th Floor Life Safety
SEC 1003 SEC 1018.4 SEC 1014.3
Current Revision
Current Revision Date
SEC 1015.2.1
SIM
04/07/14 04/02/14 04/02/14 04/02/14 04/02/14 04/02/14 04/02/14 04/02/14 04/02/14 04/02/14 04/02/14 04/02/14 04/02/14 04/02/14 04/14/14 04/02/14 04/02/14 04/14/14 04/14/14 04/02/14 04/02/14 04/17/14 04/02/14 04/17/14 04/02/14 04/02/14 04/02/14
PROJECT AREA: 14,171 SF THE PROJECT CONSISTS OF DEMOLITION OF EISTING WALLS, EXISTING POWER + COMMUNICATIONS FIXTURES, EXISTING PLUMBING AND EXISTING FLOORING NEW CONSTRUCTION INCLUDES NEW PARTITIONS, REWORKED CEILING GRID + TILE, NEW POWER + COMMUNICATIONS FIXTURES, NEW PLUMBING FOR LAVATORIES AND TOILETS, NEW FINISHES SUCH AS TERRAZZO, CARPET, PAINT AND WALLCOVERING. NEW MILLWORK WILL ALSO BE INSTALLED.
1 A101
SIM
Chicago, IL Knoxville, TN
TENNESSEE ORTHOPEDIC CLINIC 625 South Gay Street, Suite 300 Knoxville, TN 37902
Consultant Address Address Phone Fax e-mail Consultant Address Address Phone Fax e-mail Consultant Address Address Phone Fax e-mail
1 Ref
Consultant Address Address Phone Fax e-mail
ELEVATION INDICATOR: ELEV # / SHEET # Name
IBC TABLE 803.3 (SPRINKLED) TABLE 803.3 CLASS B, FLAME SPREAD INDEX 26-75; SEC 803.1.1 SMOKE DEVELOPED INDEX 0-450 CLASS C, FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED INDEX 0-450 2013 NFPA 13, 70 & 72
Elevation
Room name
ELEVATION HEIGHT INDICATOR ROOM TAG
1i
WALL TYPE SYMBOL
1
DOOR TYPE SYMBOL No.
75' 5' MAX DISTANCE FROM EACH EXIT
2
A8.01 Cast Room 3 Typical
3rd rn Ba
REFRIGERATOR REQUIRED REVISION/REVISED ROOM
HDW
HARDWARE
INT
INTERIOR
JAN JUNC
JANITOR JUNCTION
LAB LAM LAV
LABORATORY LAMINATED LAVATORY
MAX MECH
MAXIMUM MECHANICAL
SAN SCHED SEC SF SIM SPECS SQ SS STD STOR SW
SANITARY SCHEDULE SECRETARY SQUARE FOOT SIMILAR SPECIFICATIONS SQUARE STAINLESS STEEL STANDARD STORAGE SWITCH
MEZZ MFR MGR MISC MIN
MEZZANINE MANUFACTURER MANAGER MISCELLANEOUS MINIMUM
UON
UNLESS OTHERWISE NOTED
NIC NTS NOM
NOT IN CONTRACT NOT TO SCALE NOMINAL
VCT VENT VERT VWC VEST
VINYL COMPOSITION TILE VENTILATION VERTICAL VINYL WALLCOVERING VESTIBULE
OC OPNG OPP PL/PLAM PLYWD
ON CENTER OPENING OPPOSITE PLASTIC LAMINATE PLYWOOD
W/ WC WD WKS W/O
WITH WALLCOVERING WOOD WORKSTATION WITHOUT
TV TYP
3
QUANTITY
REF/REFRIG REQ REV RM
UP A8.01
DN
4
3rd Flo Door or Le ad
PAINT
QTY
UP DN
A8.01
A8.01 2
D 3
3 3rd Floor Entry Door
A8.01 PT Therapist 1 Counter
TELEVISION TYPICAL
A6.01A
5 4
A6.01A
Reception ReElevatioin ception EleBack vat Front ion -
ELEVATION ELEVATOR EQUAL EQUIPMENT EXISTING
PT
GAUGE GALVANIZED GYPSUM WALL BOARD GYPSUM BOARD
D
EL ELEV EQ EQUIP EXST
FIRE EXTINGUISHER FLOOR FURNITURE
GA GALV GWB GYP BD
5 4th Floor Entry Door
1 3rd + 4th Single Glass Curtain Door
5
42" x Fram 84" 6 Doon ed Gl ass tior sta A6.01A ork W A8.01 T 2 P
A6.01A
-
2
3
Tennessee Orthopedic Clinic
A6.01A -
Drawing Title:
General Project Information
Typical Mounting 2 Heights
2
DIAMETER DIMENSION DOWN DOOR DETAIL DRAWING
3
DIA DIM DN DR DTL/DET DWG
FE FL FURN
A6.01A
or Do
CARPET CABINET CENTERLINE CEILING CEILING HEIGHT CLEAR CONFERENCE CONTINUOUS CORRIDOR
Date
3
BUILDING BOTTOM
CPT CAB CL CLG CLGHT CLR CONF CONT CORR
Description
2 3
2
BLDG BOT
Denver, CO Portland, OR
www.mitchell+ballentinedesign.com
ENLARGED PLAN DETAIL: DWG # / SHEET #
ABBREVIATIONS AIR CONDITIONER ADJACENT ADMINISTRATION ABOVE FINISHED FLOOR ALTERNATE ALUMINUM APPROXIMATE ARCHITECTURAL AVERAGE
Mitchell + Ballentine Design 1715 Volunteer Blvd, Suite 401 Knoxville, TN 37916 Phone: 760.668.3588 Fax: 760.668.6800 jballent@utk.edu lmitch16@utk.edu
SECTION INDICATOR: DWG # / SHEET #
A101
SEC 1018.2 SEC 1019.2 SEC 1019.2
TN ACCESSIBILITY CODE, SECTION 68-120-204(a)(1) VIII. ADA ACCESSIBILITY A. TURNING RADIUS 5' B. MINIMUM UNBOSTRUCTED CLEARANCE: 18" (PULL SIDE) + 12" (PUSH SIDE) C. RESTROOM ACCESS AND CLEARANCE AFF PER APPLICABLE PROVISIONS: DISPENSERS @ 48"; GRAB BARS @ 33"-36"; TOILETS @ 17"-19"; LAVATORIES @ 34"; COUNTERS @ 34" D. CLEARANCES: KNEE @ 27"; TOE @ 6" E. GRAB BARS: DIAMETER - 1 1/4"-2" DIAMETER, 42" LENGTH MIN, 1 @ 36" MINIMUM (BEHIND TOILET)
A/C ADJ ADMIN AFF ALT ALUM APPROX ARCH AVS
PROJECT SCOPE SUMMARY
ARCHITECTURAL SYMBOLS 1
1 PERSON/100 S.F. = 103 PERSONS 1 PERSON/100 S.F. = 37 PERSONS
INTERIOR FINISH CERTIFICATES A. FINISH REQ. BASED UPON OCC. B. EXITS C.
A0.00 A1.03A A1.03B A1.04A A1.04B A2.03 A2.04 A3.03 A3.04 A4.03 A4.04 A5.03 A5.04 A6.01A A6.01B A6.10 A7.01A A7.01B A7.10A A7.10B A7.20 A7.20B A7.30 A7.30B A8.01 LS1.03 LS1.04
2012 INTERNATIONAL EXISTING BUILDING CODE 2012 EDITION OF THE INTERNATIONAL PLUMBING CODE 2012 EDITION OF THE INTERNATIONAL MECHANICAL CODE 2008 EDITION OF THE NATIONAL ELECTRICAL CODE 2012 INTERNATIONAL FIRE CODE WITH LOCAL AMENDMENTS 2012 ED OF THE INTERNATIONAL FUEL GAS CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2006 LIFE SAFETY CODE (NFPA 101)
PROJECT DESCRIPTION
Sheet Issue Date
Sheet Name
Reception Elevatioin Back
III.
INDEX OF DRAWINGS Sheet Number
865-595-4480 865-215-3939
Project number DN
UP
A4.04
Date Drawn by Checked by
1
003 - Level 3 KEY PLAN 1/16" = 1'-0"
2
004 - Level 4 KEY PLAN 1/16" = 1'-0"
TOC-001-2014 Issue Date John Ballentine Checker
A0.00 Scale
As indicated
Project Information