Options & accessories -
indoor Ceiling mounted cassette units Round flow (800x800)
4-way (600x600)
FXFQ 20~125A
FXZQ 15~50A
FXCQ 20~40A
FXCQ 50~63A
FXCQ 80 ~125A
*4
*4
*4
*4
*4
BRC7F532F
BRC7F530W *9*10 (white panel) BRC7F530S *9*10 (grey panel) BRC7E530W *9*10 (standard panel)
BRC7C52
BRC7C52
BRC7C52
BRC2C51 Simplified wired remote control
-
-
-
-
-
BRC3A61 Remote control for hotel use
BRC1E52A/B Premium wired remote control with full-text interface and back-light BRC1D52 Standard wired remote control with weekly timer
Adapters and control
Infrared remote control including receiver
-
-
-
-
-
DCS302C51 Central remote control
DCS301B51 Unified ON/OFF control
DST301B51 Schedule timer
DCS601C51 Intelligent Touch Manager External wired temperature sensor External wireless temperature sensor
KRCS01-4B
KRCS01-4
KRCS01-4
KRCS01-4
K.RSS
K.RSS
K.RSS
K.RSS
K.RSS
KRP4A53 *2
KRP4A51
KRP4A51
KRP4A51
-
-
KRP2A51
KRP2A51
KRP2A51
Wiring adaptor with 4 output signals (Compressor / Error, Fan, Aux. heater, Humidifier output)
EKRP1C11 *2*7
EKRP1B2
EKRP1B2
EKRP1B2
EKRP1B2
Wiring adaptor with 2 output signals (Compressor / Error, Fan output)
KRP1BA57 *2*7
KRP2A526
-
-
-
Adaptor for multi-tenant applications (24VAC PCB power supply interface)
DTA114A61
DTA114A61
-
-
-
-
-
DTA104A61
DTA104A61
DTA104A61
External control adaptor for outdoor unit Installation box / Mounting plate for adaptor PCBs (For units where there is no space in the switchbox)
KRP1H98 *7
KRP1B101
KRP1C96
KRP1C96
KRP1C96
Connector for forced-off contact
standard
standard
standard
standard
standard
Connection to centralized control
standard
-
-
-
-
Electrical box with earth terminal (2 blocks)
KJB212A
-
KJB212A
KJB212A
KJB212A
Electrical box with earth terminal (3 blocks)
KJB311A
-
KJB311A
KJB311A
KJB311A
BYCQ140D7GW1 (self clean) *5/*6 BYCQ140D7W1W (white) *3 BYCQ140D7W1 (standard)
BYFQ60C2W1W (white panel) BYFQ60C2W1S (grey panel) BYFQ60B2W19 (standard panel)
BYBCQ40HW1
BYBCQ63HW1
BYBCQ125HW1
Decoration panel (obligatory for cassette units, optional for others, rear panel for FXLQ)
Others
KRCS01-4
KRP4A53 *2*7
Wiring adaptor for external monitoring/control via dry contacts and setpoint control via 0-140Ω Wiring adaptor for external central monitoring/control (controls 1 entire system)
Kit for mounting of decoration panel direct onto unit
-
-
-
-
-
Panel spacer for reducing required installation height
-
KDBHQ44B60
-
-
-
KDBHQ55B140 *7
BDBHQ44C60 (white & grey panel) KDBHQ44B60 (standard panel)
-
-
-
KDDQ55B140-1 + KDDQ55B140-2 *7*8
KDDQ44XA60
KDDQ50A140
-
-
Sealing kit for 3-directional or 2-directional air discharge Fresh air intake kit Air discharge adaptor for round duct
-
-
-
-
-
Filter chamber for bottom suction
-
-
KDDFP53B50
KDDFP53B80
KDDFP53B160
KAFP551K160
KAFQ441BA60
KAFP531B50
KAFP531B80
KAFP531B160
standard
standard
standard
standard
standard
BRYQ140A
BRYQ60A2W (white panel) BRYQ60A2S (grey panel)
-
-
-
-
-
KEK26-1A
KEK26-1A
KEK26-1A
Replacement long life filter Drain pump kit Sensor kit Noise filter (for electromagnetic use only) *2 Installation box is necessary for these adaptors *3 The BYCQ140D7W1W has white insulation
Be informed that formation of dirt on white insulation is visibly stronger and that it is consequently not advised to install the BYCQ140D7W1W decoration panel in environments exposed to concentrations of dirt"
*4 Not recommended because of the limitation of the functions *5 To be able to control the BYCQ140D7GW1 the controller BRC1E is needed *6 The BYCQ140DGW1 is not compatible with Mini VRV, Multi and Split Non-Inverter Outdoor units *7 Option not available in combination with BYCQ140D7GW1 *8 Both parts of the fresh air intake are needed for each unit *9 Sensing function not available *10 Independently controllable flaps function not available
162
2-way blow