Vacon 10

Page 1

vacon 10 easy and smart

1


easy and smart The Vacon 10 is a compact AC drive speed control solution for all general-purpose applications including pumps, fans, material handling, door applications and many other. Thanks to its smart design with loadable application modules and availability in all voltage versions, the Vacon 10 is the ideal solution for OEM customers who are looking for an easy product which is at home everywhere. Easy installation and commissioning • Small physical size

BENEFIT

• Saving installation cost

• DIN rail and screw mountable

• Savings, no extra option needed

• Intelligent menu

• Saving commissioning time

Versatile features • Simplifies offering

• Extensive and fully programmable I/O

• Savings, no extra cost

• Modbus as standard • Varnished boards as standard

BENEFIT

• Longer lifetime in demanding environment

• Brake chopper in 3-phase MI2 and MI3 frames

• Savings, no extra option

• PI controller as standard

• Savings, no extra option

• Integrated EMC C2 level filter as option

• Savings, no extra option

Environment-friendly • RoHS compliant

BENEFIT

• Saving in recycling costs

• Recyclable materials

• Smaller C02 footprint

• Optimized energy consumption

• Saving energy

Extensive PC Tools • Vacon Live – commissioning

• Saving commissioning time • Saving service time

• Vacon Programming – software creation

• Additional customer value

mi1 2

BENEFIT

• Vacon Loader – software loading

mi2

mi3


the possibilities

PE plate with 360°

NEMA Type 1 upgrade kit with

IP21 top cover adds protection

MCA adapter for parameter

earthing of cable shields

conduit box and top cover

against dripping water

cloning and USB cable

Terminal

Description

1 2 3 6 7 8 9 10 A B 4 5 13 14 15 16 18

+10 Vref AI1 GND 24 Vout GND DI1 DI2 DI3 A - RS485 B - RS485 AI2 GND GND DI4 DI5 DI6 AO

Maximum load 10 mA 0-+10 V R i = 200 kΩ

Loadable application software

20

DO

• Flexible standard software

22 23 24 25 26

• Motor potentiometer application • Door machinery application • PFC Multi-pump control for booster sets

±20 %, max. load 50 mA

0-+30 V R i = 12 kΩ Positive Negative 0(4)-20 mA, R i = 200 Ω

RS485 Limited API API x x* x x x x x x x x x x x x x x

0-+30 V R i = 12 kΩ

0(4)-20 mA, Rl ≤ 500 Ω Open collector, max. load 48 V/50 mA RO13-CM Max. switching load: RO14-NO 250 Vac/2 A or 250 Vdc/0.4 A RO22-NC Max. switching load: RO21-CM 250 Vac/2 A or 250 Vdc/0.4 A RO24-NO

Full API x x x x x x x x x x x x x x x x x x

x x

x x

x x x x x

* Selectable V/mA with dip switch.

• Customer-specific versions

vacon 10 type designation code vacon 0010-1l-0001-4-machinery +option codes Product

Input Current

Voltage Version

phase rating

rating

+Options

Default configuration: +SM03 +EMC4

+Options (factory installed)

Loose options

Option

Order code

Description

Option

Order code

Description

Full API

+SM01

Full I/O configuration

IP21 Cover

ENC-IP21-MIx

x = Frame size 1, 2 or 3

Limited API

+SM02

Limited I/O configuration

NEMA Type 1 Kit

ENC-IN01-MIx

x = Frame size 1, 2 or 3

MCA and USB Cable Kit

Micro communication VACON-ADP-MCAA-KIT adapter with USB cable

MCA Adapter

VACON-ADP-MCAA

MCA Adapter only

USB Cable

CAB-USB/ RS485

USB cable only. For use with MCA or Vacon 100

Brake resistor MI2 & MI3*

BRR-0022-LD-5

Low duty

Brake resistor MI2 & MI3*

BRR-0022-HD-5

High duty

RS485 API

+SM03 (default)

RS485 I/O configuration

EMC C2

+EMC2

C2 Level EMC, includes +QPES

EMC C4

+EMC4 (default)

C4 level EMC

PE Plate

+QPES

Grounding and cable clamping extension

*Resistors not suitable for MI2/380-480 V and MI3/575 V version.

3


technical data 110...120 V, -15 %...+10 % 1~ 208…240 V, -15 %...+10 % 1~ Input voltage Uin 208…240 V, -15 %...+10 % 3~ 380...480 V, -15 %...+10 % 3~ Mains connection 575 V, -15 %...+10 % 3~ Input frequency 45…66 Hz Connection to mains Once per minute or less (normal case) Output voltage 0...Uin (2 x Uin with 115 V drives) Continuous rated current IN at rated ambient temperature Output current overload 1.5 x IN max. 1 min/10 min Starting current / Current 2 x IN for 2 secs in every 20 sec period Motor connection Torque depends on motor Torque Output frequency 0…320 Hz Frequency resolution 0.01 Hz Control method Frequency Control U/f. Open loop sensorless vector control Switching frequency 1.5...16 kHz; Factory default 4 kHz (575 V model default 2 kHz) Control characteristics 100 % x TN with integrated brake chopper in 3-phase MI2 and MI3 frames Braking torque 30 % x TN with DC-braking. Dynamic flux braking available in all types –10°C (no frost)…+50°C: rated loadability IN Ambient operating temperature (with options ENC-IP21-MIx and ENC-IN01-Mix ambient max. +40°C) Storage temperature –40°C…+70°C Ambient conditions 100 % load capacity (no derating) up to 1000 m Altitude 1 % derating for each 100 m above 1000 m; max. 2000 m Enclosure class IP20 Immunity Complies with EN61800-3 (2004) 208-240 V: EMC level C2: with an internal +EMC2 option EMC Emissions 380-480 V: EMC level C2: with an internal +EMC2 option EN61800, C-Tick, Gost R, CB, CE, UL, cUL, IEC (not all versions, see unit nameplate for more detailed approvals) Approvals

ratings and dimensions Supply voltage

AC drive type

VACON0010-1L-0001-1 VACON0010-1L-0002-1 110-120 VAC, 1-phase VACON0010-1L-0003-1 (North America only) VACON0010-1L-0004-1 VACON0010-1L-0005-1 VACON0010-1L-0001-2 VACON0010-1L-0002-2 VACON0010-1L-0003-2 208-240 VAC, 1-phase VACON0010-1L-0004-2 VACON0010-1L-0005-2 VACON0010-1L-0007-2 VACON0010-1L-0009-2 VACON0010-3L-0001-2 VACON0010-3L-0002-2 VACON0010-3L-0003-2 208-240 VAC, 3-phase VACON0010-3L-0004-2 VACON0010-3L-0005-2 VACON0010-3L-0007-2 VACON0010-3L-0011-2 VACON0010-3L-0001-4 VACON0010-3L-0002-4 VACON0010-3L-0003-4 VACON0010-3L-0004-4 380-480 VAC, 3-phase VACON0010-3L-0005-4 VACON0010-3L-0006-4 VACON0010-3L-0008-4 VACON0010-3L-0009-4 VACON0010-3L-0012-4 VACON0010-3L-0002-7 VACON0010-3L-0003-7 575 VAC, 3-phase VACON0010-3L-0004-7 (North America only) VACON0010-3L-0006-7 VACON0010-3L-0009-7

Power kW 0.25 0.37 0.55 0.75 1.1 0.25 0.37 0.55 0.75 1.1 1.5 2.2 0.25 0.37 0.55 0.75 1.1 1.5 2.2 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 0.75 1.5 2.2 4 5.5

Motor current HP 0.33 0.5 0.75 1 1.5 0.33 0.5 0.75 1 1.5 2 3 0.33 0.5 0.75 1 1.5 2 3 0.5 0.75 1 1.5 2 3 5 5 7.5 1 2 3 5 7.5

IN (A) 1.7 2.4 2.8 3.7 4.8 1.7 2.4 2.8 3.7 4.8 7 9.6 1.7 2.4 2.8 3.7 4.8 7 11 1.3 1.9 2.4 3.3 4.3 5.6 7.6 9 12 1.7 2.7 3.9 6.1 9

1.5 x IN (A) 2.6 3.6 4.2 5.6 7.2 2.6 3.6 4.2 5.6 7.2 10.5 14.4 2.6 3.6 4.2 5.6 7.2 10.5 16.5 2.0 2.9 3.6 5.0 6.5 8.4 11.4 13.5 18.0 2.6 4.1 5.9 9.2 13.5

Frame size

Dimensions W x H x D* mm

inches

MI2

90 x 195 x 102

3.54 x 7.68 x 4.02

MI3

100 x 255 x 109

3.94 x 10.04 x 4.29

MI1

66 x 160 x 99

2.60 x 6.30 x 3.90

MI2

90 x 195 x 102

3.54 x 7.68 x 4.02

MI3

100 x 255 x 109

3.94 x 10.04 x 4.29

MI1

66 x 160 x 99

2.60 x 6.30 x 3.90

MI2

90 x 195 x 102

3.54 x 7.68 x 4.02

MI3

100 x 255 x 109

3.94 x 10.04 x 4.29

MI1

66 x 160 x 99

2.60 x 6.30 x 3.90

MI2

90 x 195 x 102

3.54 x 7.68 x 4.02

MI3

100 x 255 x 109

3.94 x 10.04 x 4.29

MI3

100 x 255 x 109

3.94 x 10.04 x 4.29

* Please note that some options might increase the dimensions.

www.vacon.com

4 Subject to change without notice.

BC00245F

Vacon Partner


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.