Smarty Defibrillator Catalogue

Page 1

SMARTY DEFIBRILLATORS SMART DESIGN SMART TECHNOLOGY .

MISSION

Market
delivering
supplies
We will
quality
to provide customers with products
services
expectations.
We
creating
trusted
efficiency, value, and
KEY FACTS + Founded 1999 + 103,000 ft2 Warehouse + Central Location - Warrington + 1,000 Stocked Lines + 3,000 Line Product Portfolio + SAP Operating System + Kit Assembly + Pick and Pack + Supply Chain Management + Private Label + Quality & Regulatory Expertise CONTINUING TO STRIVE Product development, quality and innovation are the cornerstones of our business. 01
OUR
To be the
Leader,
excellence in the first aid and healthcare
industry.
continue to be entrepreneurial, building on our history of product knowledge and market expertise. We will focus on
and innovation
and
that satisfy and exceed
We will lead the industry.
care deeply about our staff, customers, and our place in the world, priding ourselves on what we do together, supporting our communities,
a great place to work, and celebrating our successes. We are experts and
advisors in our market focused on innovation, quality,
sustainability. We are the best in our industry.

USEFUL INFORMATION FOR BUYING A DEFIBRILLATOR

WHAT IS A DEFIBRILLATOR?

Defibrillators are used when a person is in cardiac arrest. They deliver an energy shock to the heart (defibrillation).

Defibrillators are known by several names, including:

• AED

• Automated External Defibrillator

• Defib

• Defibrillator

• Public Access Defibrillator (PADs)

HOW TO USE A DEFIBRILLATOR

Defibrillators should be easily accessible in all settings. In an instance where one is locked in a cabinet, instructions on how to get in will be provided. Visual and audible instructions are also provided to enable the person to deliver CPR with the defibrillator. Defibrillation within the first three minutes of cardiac arrest can increase chances of survival by up to 70%, reducing at approximately 10% per minute after this.

TYPES OF DEFIBRILLATOR

There are two types of defibrillator; Semi-Automatic and Fully Automatic. Semi-automatic defibs require the rescuer to press a button to deliver a shock, whereas fully automatic defibrillators deliver them automatically.

MAINTENANCE

• Check the defibrillator regularly and ensure they are accessible

• Ensure there are no fault warnings on the defib

• Ensure all pads are within their expected life

• Ensure batteries have sufficient charge

SEMI AUTOMATIC PAGE 5 GEO PAGE 7 FULLY AUTOMATIC PAGE 4 SMART DESIGN SMART TECHNOLOGY .
02

QUALITY. AFFORDABLE. SMART.

WITHIN EVERYONE’S REACH!

The best portable AED (Automated External Defibrillator) for a quick and simple treatment of Sudden Cardiac Arrest (SCA) and to assist in delivering the Cardiopulmonary Resuscitation (CPR).

The Smarty Saver Series meets all the requirements of a modern AED: designed to be reliable, simple and easy to use by anyone, whether they are trained or not.

Even in the best of circumstances, an emergency medical response cannot respond as quickly as a bystander with access to an AED. Lightweight and portable, thanks to the folding handle, the compact and catchy look, are conceived to meet the “gold standard” for early defibrillation in public areas.

The advanced electronics guarantee the functionality which you would expect from larger AED’s, in a compact size.

THE SMARTY DEFIBRILLATOR RANGE
KEY
FEATURES: • Reduced dimensions (A4 size) • Practical folding handle • Audio and visual signals for users • Guidance through voice prompt and metronome • Universal preconnected electrodes
• BTE waveform defibrillation with shocks 200J ADVANCED FEATURES:
REDUCED DIMENSIONS & INTUITIVE USE INSTANT SWITCH ADULT/CHILD MODE FULLY AUTOMATIC OR SEMI-AUTOMATIC OPERATION IP 56 DUST/WATER RESISTANCE FAST SHOCK ADMINISTRATION 9 SECONDS 03
• Smarty Saver Geo: CPR quality feedback in real time + access to Amisavercloud Platform

SMARTY SAVER FULLY AUTOMATIC

LIGHTWEIGHT AND CATCHY DESIGN

INSTANT SWITCH FROM ADULT TO PAEDIATRIC MODE WITH UNIVERSAL ELECTRODES

BTE WAVEFORM DEFIBRILLATION WITH SHOCKS AT 200J

The basic model of the Smarty Saver Series line is very affordable and easy to use. Reliable and durable {l meter drop test - dustproof and waterproof resistance IP rate 56). It can be easily operated by anyone in the medical field (e.g. ambulance, emergency room, etc.) and non-medical field too (e.g. public or private places).

It delivers one or more de-fibrillating shocks on adult or paediatric patients affected by ventricular fibrillation or ventricular tachycardia, by means of a thorax impedance-compensated, biphasic truncated exponential discharge {BTE).

The Fully Automatic model will, if a shockable rhythm is detected, warn the user of the imminent shock delivery and after 5 seconds the de-fibrillating shock will be released automatically; the CPR phase will follow.

SMART DESIGN SMART TECHNOLOGY . 04

SMARTY SAVER SEMI AUTOMATIC

The Semi-Automatic model analyses the patient’s ECG and if a shockable rhythm is detected it automatically starts charging the reservoir capacitor. The AED vocal message will suggest the operator presses the shock button to deliver the de-fibrillating shock.

The phase following the de-fibrillation, Cardiopulmonary Resuscitation, will be guided by voice prompts and the metronome marking the various cycles of compressions and insufflations.

The semi-automatic defibrillator allows the user to deliver shocks faster than an automatic defibrillator, but requires higher concentration.

SWITCH
ADULT TO PAEDIATRIC MODE WITH UNIVERSAL ELECTRODES
DEFIBRILLATION
05
LIGHTWEIGHT AND CATCHY DESIGN INSTANT
FROM
BTE WAVEFORM
WITH SHOCKS 200J

TECHNICAL DATA SHEET

DEFIBRILLATOR

Model:

Maximal energy: Waveform: Discharge protocol: Charging time from shock alert*:

Charging time from analysis time*:

Analysis time: Impedance range: Sensitivity: Specificity: Controls: Semi-automatic model

Fully Automatic model Light indicators: Upgradeable:

Code SMl-B1001: Semi-Automatic Code SM2-B1002: Fully Automatic 200J (nominal)

Biphasic truncated exponential (BTE) automatically adapts according to patient’s impedance

Adult: incremental first shock 1 50J - subsequent 200J Paediatric: fixed 50J

IEC60601-2-4

≤ 9 sec with shock at 1 50J ≤ 1 2 sec with shock at 200J

IEC60601-2-4

≤ 1 3 sec with shock at 1 50J ≤ 1 6 sec with shock at 200J

IEC/EN 60601-2-4 from 4 to 1 5 seconds 20-200 Ohms 97% (IEC/EN 60601-2-4) 99% (IEC/EN 60601-2-4)

4 buttons: ON/OFF, shock delivery, patient selection (adult/child) 3 buttons: ON/OFF, patient selection (adult/child} Device status: 2 LEDs red /green PADs placement: 2 red LEDs - Do not touch the patient: 2 red LEDs Touch the patient: 1 green LED Adult patient: 1 green LED Paediatric patient: 1 green LED ON/OFF button : 2 green LEDs Shock button: 8 red LEDs Through USB cable External memory card

DEFIBRILLATION PADS

Type: Dimensions: Shelf-life: BATTERY Type: Voltage/capacity: Autonomy:

Stand by life:

Code SMT-C2001: Disposable, universal, pre-gelled, preconnected Code SMT-C2002: Disposable, universal, pre-gelled, preconnected, Face-to-Face

Total surface 136cm2; active surface 94cm2; 120cm cable length (external to the packaging) 24-30 months, as indicated on the packaging

Code SMT-Cl 4031: Disposable battery 8 cells Li-MnO2 12VDC-3000mAh

Up to 200 complete rescue cycles (200J shocks + CPR);

Up to 36 hours of continuous ECG analysis*

PHYSICAL Size:

Weight:

EVENT RECORDING

Optional external memory: Stored data:

“AEDFILE.aed”review:

* performance referred to new batteries stored at a temperature of 20’C and relative humidity 45% without condensation

ENVIRONMENTAL SPECIFICATION

Operating temperature: Storing/Shipping temperature: Humidity:

Sealing {IP Protection): Shock/Drop Abuse Endurance: Electrostatic Discharges: Electromagnetic Compatibility: Protection from defibrillation: Classification:

Up to 3 years with a battery insertion test and daily self-test without any turning on the AED* 0°C to 45°C {32°F to 113°F)

-40°C to 70°C (-40°F to 158°F) 10% to 95% relative humidity non condensing IEC/EN 60529: class IP56

IEC/EN 60601-1 clause 21 IEC/EN 61000-4-2

IEC/EN 60601-1 -2:2015

IEC/EN 60601-1; device internally powered, Type BF Directive 93/42/CEE Amd 2007/47/CE: Class lib, Annex IX Rule 9

200x213x71 mm (folded handle) 257x213x71 mm (open handle) 1 ,56 Kg (with battery and PADs) Micro uSD/SDHC card up to 32GB “AEDl LOG.txt”: text file with detailed report of the activities of self-test and power-ups “AEDFILE.aed”: ECG trace, rescue events, voices and
audio Through data manager software
Express”
a 50 Ohm patient and with a fully charged new battery
background
“Saver View
*On
SMART DESIGN SMART TECHNOLOGY . 06

SMARTY SAVER GEO CPR QUALITY AND GEO SYSTEM

CPR QUALITY EEDBACK

GEO SYSTEM TO LOCALIZE AND MONITOR THE AED DEVICE “VIVO” BUTTON FOR LIVE EMERGENCY CALL

In addition to the Q-CPR module, the Smarty Saver Geo is equipped with a SIM card and a GPS/ GPRS system; the GPRS system allows the Smarty Saver Geo to transmit and receive data through a mobile phone network, while the GPS system enables the tracking of the AED movements. This info is sent by the device to the Amisavercloud Platform, which monitors and controls multiple AEDs remotely through any web browser and internet connected device. Info and data sent to the platform include position and current status of the AED, the device can also transmit the ECG in real time.

A professional operator will be able to view and examine the ECG, real time, remotely on the Amisavercloud Platform while the ECG is being performed on the patient.

The dedicated ‘Vivo’ button located on the keyboard lets the operator call the local EMS straight away, directly to the AED. These features make the Smarty Saver Geo ideal for use in moving vehicles such as trains, buses and ambulances.

The device is powered by two independent batteries - one to supply AED functions and one to supply the additional Geo system functions - in order to preserve the primary use of the device as automatic external defibrillator .

07

GEO SYSTEM: REAL TIME AED MANAGEMENT

All the functions can be managed remotely, by any device, through the Amisavercloud Platform:

TELEMETRY

Smarty Saver Geo connects to the portal daily, sending a log that contains detailed information on its status; this will be shown on the map with a coloured icon. In case of anomaly, the Amisavercloud will notify the authorized user by SMS or e- mail (customizable alert). device ready to use warning - anomaly that does not compromise the defibrillator functions faulty device - assistance required

GEOLOCATION

The platform can show:

• AED location: the exact position will be identifiable on the map.

• AED movements (self-tracking function): the AED journey will be visible on the map; if the “anti-theft” function is on the user will be notified by SMS/e-mail every time the AED is moved.

REMOTE ASSISTANCE - STREAMING ECG

The AED is able to transmit the ECG in real time; this can be viewed by any web connected device, via the Amisavercloud Portal. In addition, all ECGs sent will be saved in the portal and made available for subsequent consultations.

“VIVO” BUTTON FOR LIVE CALLS

The operator can promptly call the local EMS by pressing the dedicated button on the AED keyboard. According to the local regulation, three telephone numbers can be set up to automatically attempt multiple calls until answered.

SMART DESIGN SMART TECHNOLOGY .
08

TECHNICAL DATA SHEET

DEFIBRILLATOR

Model:

Maximal energy: Waveform: Discharge protocol: Charging time from shock alert*:

Charging time from analysis time*:

Analysis time:

Impedance range: Sensitivity: Specificity: Controls: Semi-automatic model

Fully Automatic model Light indicators:

Code SM5-Bl 005: Semi-Automatic

Code SM6-Bl 006: Fully Automatic 200J (nominal)

Biphasic truncated exponential (BTE) automatically adapts according to patient’s impedance

Adult: incremental first l 50J - subsequent 200J Paediatric: fixed 50J

IEC60601-2-4

≤ 9 sec with shock at 1 50J ≤ 12 sec with shock at 200J

IEC60601-2-4

≤ 13 sec with shock at l 50J ≤ 16 sec with shock at 200J IEC/EN 60601-2-4 from 4 to 15 seconds 20-200 Ohms 97% (IEC/EN 60601-2-4) 99% (IEC/EN 60601-2-4)

6 buttons: ON/OFF, shock delivery, patient selection (adult/child), live call, ECG streaming

5 buttons: ON/OFF, patient selection (adult/child), live call, ECG streaming

BATTERY

Type:

Voltage/capacity: Autonomy:

Stand by life:

Code SMT-Cl 4032: Disposable battery 8 cells Li-Mn02 Ah l 2VDC- 3000mAh Up to 200 complete rescue cycles (200J shocks + CPR); Up to 36 hours of continuous ECG analysis*

Upgradeable:

*On

PHYSICAL

Size:

Weight:

EVENT RECORDING

Optional external memory: Stored data: “AEDFILE.aed”review:

DEFIBRILLATION PADS

Type: Dimensions: Shelf-life:

Device status: 2 LEDs red/green PADs placement: 2 red LEDs Do not touch the patient: 2 red LEDs Touch the patient: 1 green LED Adult patient: 1 green LED Paediatric patient: 1 green LED ON/OFF button: 2 green LEDs Shock button: 8 red LEDs

- CPR Quality feedback 8 LED bar. 2 red + 2 orange + 2 yellow + 2 green Q-CPR module connection: 1 green fixed LED ECG streaming: 1 green blinking LED Through USB cable External memory card, remotely

ENVIRONMENTAL SPECIFICATION

Operating temperature: Storing/Shipping temperature: Humidity:

Sealing {IP Protection): Shock/Drop Abuse Endurance: Electrostatic Discharges: Electromagnetic Compatibility: Protection from defibrillation: Classification:

Up to 3 years with a battery insertion test and daily self-test without any turning on the AED* 0°C to 45°C {32°F to 113°F)

* performance referred to new batteries stored at a temperature of 20’C and relative humidity 45% without condensation

-40°C to 10°C (-40°F to 158°F) 10% to 95%

relative humidity non condensing IEC/EN 60529: class IP56

IEC/EN 60601-1 clause 21 IEC/EN 61000-4-2

IEC/EN 60601-1-2:2015

Micro uSD/SDHC card up to 32GB “AEDl LOG.txt”: text file with detailed report of self- test activities and power ups

“AEDFILE.aed”: ECG trace, rescue events, voices and background audio Through data manager software “Saver View Express”

Q-CPR EXTERNAL MODULE

Description:

Weight and Dimension: Compression guidance:

Controls and light icons: Battery:

• Type

• Voltage/capacity

• Autonomy Radio Equipment compliance:

GEOLOC MODULE Frequency:

Battery:

• Type

• Voltage/capacity Performance

Code SMT-C2001: Disposable, universal, pre- gelled, preconnected Code SMT-C2002: Disposable, universal, pre- gelled, preconnected, Face- to- Face Total surface 136cm2; active surface 94cm2; 120cm cable length (external to packaging) 24-30 months, as indicated on the packaging

Radio Equipment compliance:

Code SMT-Cl 4034

External module to support quality CPR paired with the AED via Bluetooth; Class I 95 x 60 x 13mm; 50gr

I EC/EN 60601-1; device internally powered, Type BF Directive 93/42/CEE Amd 2007/47/CE: Class lib, Annex IX Rule 9 200x213x71 mm (folded handle)

According to AHA/ERC guidelines for both adult and paediatric patients Ignition key ON/OFF Green flashing LED: Bluetooth signal search Green fix LED: Bluetooth connection active Code: SMT-Cl 4035 Battery Coin LiMnO2 3 VDC /lAh up to 2 hours in continued use

Directive 2014/53/UE- RED

GSM: 850, 900, 1800, 1900MHz; UMTS: 900, 2100MHz; GPS: 1575, 1600MHz

Contained in SMT-Cl4032; 3 cells Li- SOCl2; 10,8 VDC- 3500 mAh Geo-location, remote control of the device, live call, ECG streaming

RED- Directive 2014/53/UE

257x213x71 mm (open handle) 1,70 Kg (with battery and defibrillation PADs)
charged
a 50 Ohm patient and with a fully
new battery
10 CPR - WHAT TO DO When arriving at the scene, conduct a Primary Survey: DRABC 1. Check for DANGER 2. Check for a RESPONSE, gain consent and talk to the casualty 3. Open the AIRWAY by tilting the head back (The Head and Chin Tilt) 4. Check the casualties BREATHING every 10 seconds - look, listen and feel with your ear next to the mouth 5. Check CIRCULATION - look for abnormalities in skin colour and pulse If CPR is required, ensure the emergency services are called with 999 or 112, and send for the AED. In CPR, do 30 chest compressions, followed by 2 rescue breaths. Do this at a rate of 100 to 120 compressions per minute. When the AED is available and needed, turn on the device, remove clothing, and attach pads. Ensure nobody is touching the casualty, as this can interfere with the AED. FOLLOW INSTRUCTIONS GIVEN BY THE DEFIBRILLATOR To book a first aid training course, visit www.wallacecamerontraining.com, call 01698 354 671 or email chrisc@wallacecameron.com

SPECIFICATIONS

DEFIBRILLATOR

SMARTY SAVER FULLY AUTOMATIC

SMARTY SAVER SEMI AUTOMATIC SMARTY SAVER GEO

Model Code SM2-B1002: Fully Automatic Code SMl-B1001: Semi-Automatic

Code SM5-Bl 005: Semi-Automatic Code SM6-Bl 006: Fully Automatic

Maximal energy 200J (nominal) 200J (nominal) 200J (nominal)

Waveform

Discharge protocol

Charging time from shock alert*

Charging time from analysis time*

Analysis time

Biphasic truncated exponential (BTE) automatically adapts according to patient’s impedance

Adult: incremental first 150J - subsequent 200J Paediatric: fixed 50J

IEC60601-2-4

≤ 9 sec with shock at 150J

≤ 12 sec with shock at 200J

IEC60601-2-4

≤ 13 sec with shock at 150J ≤ 16 sec with shock at 200J

IEC/EN 60601-2-4 from 4 to 15 seconds

Biphasic truncated exponential (BTE) automatically adapts according to patient’s impedance

Adult: incremental first 150J - subsequent 200J Paediatric: fixed 50J

IEC60601-2-4

≤ 9 sec with shock at 150J ≤ 12 sec with shock at 200J

IEC60601-2-4

≤ 13 sec with shock at 150J ≤ 16 sec with shock at 200J

IEC/EN 60601-2-4 from 4 to 15 seconds

Biphasic truncated exponential (BTE) automatically adapts according to patient’s impedance

Adult: incremental first 150J - subsequent 200J Paediatric: fixed 50J

IEC60601-2-4

≤ 9 sec with shock at 150J ≤ 12 sec with shock at 200J

IEC60601-2-4

≤ 13 sec with shock at 150J ≤ 16 sec with shock at 200J

IEC/EN 60601-2-4 from 4 to 15 seconds

Impedance range 20-200 Ohms 20-200 Ohms 20-200 Ohms

Sensitivity 97% (IEC/EN 60601-2-4) 97% (IEC/EN 60601-2-4) 97% (IEC/EN 60601-2-4)

Specificity 99% (IEC/EN 60601-2-4) 99% (IEC/EN 60601-2-4) 99% (IEC/EN 60601-2-4)

Controls Semi-automatic model N/A

Controls

Fully Automatic model

Light indicators

4 buttons: ON/OFF, shock delivery, Patient selection (adult/child)

3 buttons: ON/OFF, patient selection (adult/child) N/A

Device status: 2 LEDs red/green PADs placement: 2 red LEDs

Do not touch the patient: 2 red LEDs

Touch the patient: 1 green LED Adult patient: 1 green LED Paediatric patient: 1 green LED ON/OFF button: 2 green LEDs Shock button: 8 red LEDs

Device status: 2 LEDs red/green PADs placement: 2 red LEDs

Do not touch the patient: 2 red LEDs

Touch the patient: 1 green LED Adult patient: 1 green LED Paediatric patient: 1 green LED ON/OFF button: 2 green LEDs Shock button: 8 red LEDs

6 buttons: ON/OFF, shock delivery, patient selection (adult/child), live call, ECG streaming

5 buttons: ON/OFF, patient selection (adult/child), live call, ECG streaming

Device status: 2 LEDs red/green PADs placement: 2 red LEDs

Do not touch the patient: 2 red LEDs

Touch the patient: 1 green LED

Adult patient: 1 green LED Paediatric patient: 1 green LED ON/OFF button: 2 green LEDs Shock button: 8 red LEDs

CPR Quality feedback 8 LED bar: 2 x

Q-CPR module connection: 1 green fixed LED

ECG streaming: 1 green blinking

••
••
••
x ••
+ 2 x
+ 2 x
+ 2
Upgradeable Through USB cable External memory card Through USB cable External memory card Through USB cable External memory card *On a 50 Ohm patient and with a fully charged new battery PHYSICAL Size 200x213x71 mm (folded handle) 257x213x71 mm (open handle) 200x213x71 mm (folded handle) 257x213x71 mm (open handle) 200x213x71 mm (folded handle) 257x213x71 mm (open handle) Weight 1.56 Kg (with battery and defibrillation PADs) 1.56 Kg (with battery and PADs) 1.70 Kg (with battery and PADs) TECHNICAL DATA COMPARISSON 11
LED

EVENT RECORDING

Optional external memory

Stored data

Micro uSD/SDHC card up to 32GB Micro uSD/SDHC card up to 32GB Micro uSD/SDHC card up to 32GB

“AEDl LOG.txt”: text file with detailed report of self- test activities and power ups

“AEDFILE.aed”: ECG trace, rescue events, voices and background audio

“AEDl LOG.txt”: text file with detailed report of self- test activities and power ups “AEDFILE.aed”: ECG trace, rescue events, voices and background audio

“AEDl LOG.txt”: text file with detailed report of self- test activities and power ups

“AEDFILE.aed”: ECG trace, rescue events, voices and background audio “AEDFILE.aed”review

DEFIBRILLATION PADS

Code SMT-C2001: Disposable, universal, pre- gelled, preconnected

Type

Code SMT-C2002: Disposable, universal, pre- gelled, preconnected, Face-to-Face

Code SMT-C2001: Disposable, universal, pre- gelled, preconnected

Code SMT-C2002: Disposable, universal, pre- gelled, preconnected, Face-to-Face

Code SMT-C2001: Disposable, universal, pre- gelled, preconnected

Code SMT-C2002: Disposable, universal, pre- gelled, preconnected, Face- to- Face

Dimensions

Shelf-life

BATTERY

Type

Voltage/capacity

Autonomy

Total surface 136cm2; active surface 94cm2; 120cm cable length (external to packaging)

Total surface 136cm2; active surface 94cm2 ; 120cm cable length (external to packaging)

Total surface 136cm2; active surface 94cm2; 120cm cable length (external to packaging)

24-30 months, as indicated on the packaging 24-30 months, as indicated on the packaging 24-30 months, as indicated on the packaging

Code SMT-Cl 4032: Disposable battery 8 cells Li-Mn02

Ah l 2VDC- 3000mAh

Up to 200 complete rescue cycles (200J shocks + CPR); Up to 36 hours of continuous ECG analysis*

Code SMT-Cl 4031: Disposable battery 8 cells Li-MnO2

12VDC-3000mAh

Up to 200 complete rescue cycles (200J shocks + CPR); Up to 36 hours of continuous ECG analysis*

Code SMT-Cl 4031: Disposable battery 8 cells Li-MnO2

12VDC-3000mAh

Up to 200 complete rescue cycles (200J shocks + CPR); Up to 36 hours of continuous ECG analysis*

Stand by life

Up to 3 years with a battery insertion test and daily self-test without any turning on the AED*

Up to 3 years with a battery insertion test and daily self-test without any turning on the AED*

Up to 3 years with a battery insertion test and daily self-test without any turning on the AED* * performance referred to new batteries stored at a temperature of 20’C and relative humidity 45% without condensation

2007/47/CE:

SPECIFICATIONS
SMARTY SAVER FULLY AUTOMATIC
SMARTY SAVER SEMI AUTOMATIC SMARTY SAVER GEO
Through data manager software “Saver View Express”
Through data manager software “Saver View Express”
Through data manager software “Saver View Express”
ENVIRONMENTAL SPECIFICATION Operating temperature 0°C to 45°C (32°F to 113°F) 0°C to 45°C (32°F to 113°F) 0°C to 45°C
113°F) Storing/Shipping temperature -40°C to 10°C (-40°F to 158°F) -40°C to 10°C (-40°F to 158°F) -40°C to 10°C (-40°F to 158°F) Humidity 10% to 95% relative humidity non condensing 10% to 95% relative humidity non condensing 10% to 95% relative humidity non condensing Sealing [IP Protection) IEC/EN 60529: class IP56 IEC/EN 60529: class IP56 IEC/EN 60529: class IP56 Shock/Drop Abuse Endurance IEC/EN 60601-1 clause 21 IEC/EN 60601-1 clause 21 IEC/EN 60601-1 clause 21 Electrostatic Discharges IEC/EN 61000-4-2 IEC/EN 61000-4-2 IEC/EN 61000-4-2 Electromagnetic Compatibility IEC/EN 60601-1-2:2015 IEC/EN 60601-1-2:2015 IEC/EN 60601-1-2:2015 Protection from defibrillation I EC/EN 60601-1; device internally powered, Type BF I EC/EN 60601-1; device internally powered, Type BF I EC/EN 60601-1; device internally powered, Type BF
Class lib, Annex IX Rule 9
(32°F to
Classification Directive 93/42/CEE Amd 2007/47/CE:
Directive 93/42/CEE Amd 2007/47/CE: Class lib, Annex IX Rule 9
Directive 93/42/CEE Amd
Class lib, Annex IX Rule 9

Code SMT-Cl 4034 External module to support quality CPR paired with the AED via Bluetooth; Class I

Weight and Dimension N/A N/A 95 x 60 x 13mm; 50gr

According to AHA/ERC guidelines for both adult and paediatric patients

Ignition key ON/OFF

Green flashing LED: Bluetooth signal search Green fix LED: Bluetooth connection active

Code: SMT-Cl 4035 Battery Type N/A N/A Battery Coin LiMnO2

Battery N/A N/A

Battery Voltage/ capacity N/A N/A 3 VDC /lAh up to 2 hours in continued use

Autonomy Radio Equipment compliance N/A N/A Directive 2014/53/UE- RED

GEOLOC MODULE

Frequency N/A N/A

Battery Type N/A N/A

GSM: 850, 900, 1800, 1900MHz; UMTS: 900, 2100MHz; GPS: 1575, 1600MHz

Contained in SMT-Cl4032; 3 cells Li- SOCl2

Battery Voltage/ capacity N/A N/A 10,8 VDC- 3500 mAh

Battery Performance N/A N/A

Geo-location, remote control of the device, live call, ECG streaming

Radio Equipment N/A N/A RED- Directive 2014/53/UE

SAVER
AUTOMATIC
SPECIFICATIONS SMARTY
FULLY
SMARTY SAVER SEMI AUTOMATIC SMARTY SAVER GEO Q-CPR EXTERNAL MODULE
Description N/A N/A
Compression guidance N/A N/A
Controls and light icons N/A N/A
13
SMART DESIGN SMART TECHNOLOGY . Telephone: 0845 230 2092 Fax: 0845 230 2091 Email: sales@crestmedical.co.uk Website: www.crestmedical.co.uk Contact us now to enquire
Crest Medical Ltd | 3 Chesford Grange Woolston | Warrington | WA1 4RQ t: 0845 230 2092 | f: 0845 230 2091 e: sales@crestmedical.co.uk Registered in England No. 03876927 VAT Reg No: GB927193604
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.