MetaMec_MC_E_Leaflet_0901

Page 1

Leader in Electrics & Automation

The electrical lifetime GMC- 9 - 85

Accessories

GMC- 100 - 800

Auxiliary contact Applying contactors GM-9 to 85 type (9 to 85A frame) AU-1 Side mount 2 pole block

AU-2 Front mount 2 pole block

Mounting type Front mount

Poles

Composition

Type

2 pole

2NO 2NC 1NO+1NC 4NO 3NO+1NC 2NO+2NC 1NO+3NC 4NC 1NO 1NC 1NO 1NC

AU-2

4 pole

AU-4 Front mount 4 pole block

Meta-MEC

Contactors And Overload Relays AC 3 duty (Standard) AC 4 duty (Inching, reverse phase breaking duty)

GM-100 to 800 type (100 to 800A frame)

AU-100 Side mount 2 pole block

Side mount

2 pole

Side mount

2 pole

AU-4

AU-1 AU-100

Mechanical Interlock unit

AC 3 duty (Standard) AC 4 duty (Inching, reverse phase breaking duty)

Type AR - 9 AR - 100 AR - 180 AR - 600

Table T3

Leader in Electrics & Automation

Type designations

Applied contactors GMC(D) - 9 ~ GMC(D) - 85 GMC - 100 ~ GMC - 150 GMC - 180 ~ GMC - 400 GMC - 600 ~ GMC - 800

Mechanical latch unit Type AL - 9 AL - 50 AL - 100

Table T4

Applied contactors GMC - 9 ~ 40 GMC - 50 ~ 85 GMC - 100, 125

Type AL - 150 AL - 220 AL - 400

Applied contactors GMC - 150 GMC - 180, 220 GMC - 300, 400

Surge absorber unit Type AS -11 AS -12 AS -13 AS -14 AS - 1 AS - 2 AS - 3 AS - 4 AS - 5 AS - 6

Table T5

� For your safety, please read user's manual thoroughly before operating. � Contact the nearest authorized service facility for examination, repair, or adjustment. � Please contact qualified service technician when you need maintenance. Do not disassemble or repair by yourself!

Safety Instructions

� Any maintenance and inspection shall be performed by the personnel having expertise concerned. ⓒ 2005.5 LS Industrial Systems Co.,Ltd. All rights reserved.

www.lsis.biz � HEAD OFFICE LS Tower 1026-6, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do 431-848, Korea Tel. (82-2)2034-4870 Fax. (82-2)2034-4713

Electric Equipment

Element Varistor

CR + Varistor

Cheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku, Cheong Ju, 361-720, Korea

Element spec. Varistor 120V Varistor 270V Varistor 470V Varistor 1000V Varistor 120V 0.1μF 100Ϊ Varistor 270V 0.1μF 100Ϊ Varistor 470V 0.1μF 100Ϊ Varistor 120V 0.47μF 100Ϊ Varistor 270V 0.47μF 100Ϊ Varistor 470V 0.47μF 100Ϊ

Applied contactors GMC(D)- 9 ~ GMC - 800

GMC - 9 ~ GMC - 85 GMD - 9 ~ GMD - 85

Lug terminal for contactors Type for 3 Pole

Applying contactors � Global Network

GMC-100, 125 type (100, 125A frame) GMC-150 type (150A frame) GMC-180, 220 type (180, 220A frame) GMC-300, 400 type (300. 400A frame) GMC-600, 800 type (600. 800A frame)

�LS Industrial Systems (Middle East) FZE � �Dubai, U.A.E. Address: P.O.Box-114216, API World Tower, 303B, Sheikhe Zayed Road, Dubai, U.A.E. Tel: 971-4-332-8289 Fax: 971-4-332-9444 e-mail: hwyim@lsis.biz

�Dalian LS Industrial Systems Co., Ltd. � �Dalian, China Address: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, China Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: lixk@lsis.com.cn

�LS Industrial Systems (Wuxi) Co., Ltd. � �Wuxi, china

� CHEONG-JU PLANT

Operation voltage AC/DC 24 ~ 48V AC/DC 100 ~ 125V AC/DC 200 ~ 240V AC 380 ~ 440V AC 24 ~ 48V AC 100 ~ 125V AC 200 ~ 240V DC 24 ~ 48V DC 100 ~ 125V DC 200 ~ 220V

Address: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu,214028, P.R.China Tel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: xuhg@lsis.com.cn

�LS-VINA Industrial Systems Co., Ltd. � �Hanoi, Vietnam

AJ125 (70821614008) AJ150 (70821615008) AJ220 (70821616008) AJ400 (70821617008) AJ800 (70821618008)

Address: Nguyen Khe - Dong Anh - Ha Noi - Viet Nam Tel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: srjo@lsisvina.com

�LS Industrial Systems Tokyo Office � �Tokyo, Japan Address: 16FL, Higashi-Kan, Akasaka Twin Tower 17-22, 2-chome, Akasaka, Minato-ku Tokyo 107-8470, Japan Tel: 81-3-3582-9128 Fax: 81-3-3582-2667 e-mail: jschuna@lsis.biz

�LS Industrial Systems Shanghai Office � �Shanghai, China Address: Room E-G, 12th Floor Huamin Empire Plaza, No.726, West Yan'an Road Shanghai 200050, P.R. China Tel: 86-21-5237-9977 (609) Fax: 89-21-5237-7191 e-mail: jinhk@lsis.com.cn

Enclosed type motor starters

�LS Industrial Systems Beijing Office � �Beijing, China Address: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District,

Type

Beijing 100013, P.R. China Tel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: cuixiaorong@lsis.com.cn

W/O push button

�LS Industrial Systems Guangzhou Office � �Guangzhou, China Address: Room 1403,14F,New Poly Tower,2 Zhongshan Liu Road,Guangzhou, P.R. China Tel: 86-20-8326-6764 Fax: 86-20-8326-6287 e-mail: linsz@lsis.com.cn

�LS Industrial Systems Chengdu Office � �Chengdu, China Address: 12Floor, Guodong Buiding, No52 Jindun Road Chengdu, 610041, P.R. China Tel: 86-28-8612-9151 Fax: 86-28-8612-9236 e-mail: yangcf@lsis.com.cn

�LS Industrial Systems Qingdao Office � �Qingdao, China

Specifications in this catalog are subject to change without notice due to continuous product development and improvement.

2009. 01

Address: 7B40,Haixin Guangchang Shenye Building B, No.9, Shandong Road Qingdao 26600, P.R. China Tel: 86-532-8501-6568 Fax: 86-532-583-3793 e-mail: lirj@lsis.com.cn

Contactors And Overload Relays(E) 2005. 05/(16) 2009. 01 Printed in Korea STAFF

(Metal)

(Mould)

GMW - 9(M) GMW - 12(M) GMW - 18(M) GMW - 22(M) GMW - 32 GMW - 40 GMW - 50 GMW - 65 GMW - 75 GMW - 85

With push button

GMW - 9(M)B GMW - 12(M)B GMW - 18(M)B GMW - 22(M)B GMW - 32B GMW - 40B GMW - 50B GMW - 65B GMW - 75B GMW - 85B

lth (A) 20 25 30 32 45 50 70 80 90 100

Single phase 115V 230V 0.5 1 0.5 2 1 3 2 3 2 5 3 5 3 7.5 5 10 5 15 7.5 15

Rated power (HP) Three phase 200V 230V 460V 2 2 5 3 3 7.5 5 5 10 7.5 7.5 10 7.5 10 20 10 10 25 10 15 30 15 20 40 20 25 50 25 30 60

575V 7.5 10 15 15 20 25 30 40 50 60


Frame size

9A

12A

18A

22A

32A

40A

50A

65A

75A

85A

Frame size

3-pole Contactors

Types AC coil DC coil Ratings / IEC60947-4 AC1 AC3 200/240V 380/440V 500/550V 690V Ratings / UL508 continuous current single phase 115V 230V three phase 200V 230V 460V 575V NEMA size

100A

125A

150A

180A

220A

300A

400A

600A

800A

3-pole Contactors

GMC-9 GMD-9 kW 2.5 4 4 4 hp

GMC-12 GMD-12 A 25 11 9 7 5 A 20

0.5 1 2 2 5 7.5 00

kW

GMC-18 GMD-18 A 25 13 12 12 9 A 25

3.5 5.5 7.5 7.5 hp

kW 4.5 7.5 7.5 7.5 hp

0.5 2 3 3 7.5 10 00

1 3 5 5 10 15 0

GMC-22 GMD-22 A 40 18 18 13 9 A 30

kW 5.5 11 15 15 hp 2 3 7 7.5 10 15 0

GMC-32 GMD-32 A 40 22 22 22 18 A 32

kW

GMC-40 GMD-40 A 50 32 32 28 20 A 45

7.5 15 18.5 18.5 hp

kW 11 18.5 22 22 hp

2 5 7.5 10 20 20 1

GMC-50 GMD-50 A 60 40 40 32 23 A 50

3 5 10 10 25 25 1

kW

GMC-65 GMD-65 A 80 55 50 43 28 A 70

15 22 30 30 hp 3 7.5 10 15 30 30 2

kW

GMC-75 GMD-75 A 100 65 65 60 35 A 80

18.5 30 33 33 hp

kW 22 37 37 37 hp

5 10 15 20 40 40 2

GMC-85 GMD-85 A 110 75 75 64 42 A 90

5 15 20 25 50 50 2

kW 25 45 45 45 hp

A 135 85 85 75 45 A 100

7.5 15 25 30 50 50 3

Additional auxiliary contacts

Types

AC/DC common coil

Ratings / IEC60947-4

GMC-100 kW

GMC-125 A

AC1

kW

160

AC3

200/240V

30

105

380/440V

55

500/550V

55

690V

55 hp

Ratings / UL508 continuous current

GMC-180

kW

A

160 37

125

105

60

85

60

65

60

A

hp

160

115V

7.5

150

120

75

90

90

70

90

A

hp

10

230V

15

three phase

200V

30

230V

30

40

460V

60

575V

kW

GMC-220 A

210 45

160

single phase

NEMA size

GMC-150 A

kW

GMC-300 A

230

kW

GMC-400 A

275

kW

GMC-600 A

350

kW

GMC-800 A

450

kW

A

660

900

55

180

75

250

90

300

125

400

190

630

220

800

150

90

180

132

250

160

300

220

400

330

630

440

800

140

110

180

132

200

160

250

225

350

330

500

500

720

100

110

120

132

150

200

220

250

300

330

420

500

630

A

hp

A

hp

A

hp

A

hp

A

hp

A

hp

210

230

275

350

450

900

15

15

15

20

25

30

40

40

40

60

50

60

75

100

150

200

300

75

100

125

150

200

300

400

600

60

75

100

125

150

200

300

400

600

3

3

4

4

4

5

5

6

7

60

100

125

A

660

150

250

Additional auxiliary contacts 2-pole Front mount

4-pole Front mount

2-pole Side mount

2-pole Front mount

4-pole Front mount

2-pole Side mount

AU-100 1NO+1NC, Side mount

AU-100 1NO+1NC, Side mount

4-pole Contactors 4-pole Contactors Types

AC coil DC coil

AC1(A)

GMC-9/4 GMD-9/4 20

GMC-12/4 GMD-12/4 20

GMC-18/4 GMD-18/4 25

GMC-22/4 GMD-22/4 32

GMC-32/4 GMD-32/4 50

GMC-40/4 GMD-40/4 60

GMC-50/4 GMD-50/4 80

GMC-65/4 GMD-65/4 100

GMC-75/4 GMD-75/4 110

GMC-85/4 GMD-85/4 135

Types

AC/DC common coil

AC1(A)

GMC-100/4

GMC-125/4

GMC-150/4

GMC-180/4

GMC-220/4

GMC-300/4

GMC-400/4

GMC-600/4

GMC-800/4

160

160

210

230

275

350

450

660

900

Overload Relays Setting ranges (A)

Bimetallic style Type GT

GT-22

Class10A Class 20

Differential Non-differential (3-heater) Non-differential (2-heater) Differential

4-6 5-8 6-9 7 - 10 9 - 13 12 - 16 16 - 22

Setting ranges (A) 4-6 5-8 6-9 7 - 10 9 - 13

Base for separate mount

GMP22

Base for separate mount

7 - 10 9 - 13 12 -18 16 - 22 18 - 26 24 - 36

Overload Relays

28 - 40 34 -50 45 - 65 54 - 75 63 - 85 Base for separate mount

GT-85

GTK-40/L

GMP80

Separate mount Wiring by screw

GT- 150

Setting ranges (A)

39 - 57 43 - 65 54 - 80 65 - 100

65 - 100 85 - 125 100 - 150

85 - 125 100 - 150 120 - 180

120 - 180

160 - 240

85 - 125 100 - 150

GT- 220

160 - 240

Setting ranges (A)

GT- 400

GMP60

Separate mount Wiring by CT tunnel

Setting ranges (A) 220 - 300 260 - 400 400 - 600 520 - 800

220 - 300 260 - 400 GT- 800

GTK-100

GTK-150

GTK-220

GTK-400

GTK-600

Non-differential (3-heater)

GTH-100/3

GTH-150/3

GTH-220/3

GTH-400/3

GTH-600/3

Non-differential (2-heater)

GTH-100

GTH-150

GTH-220

GTH-400

GTH-600

GTK-100/L

GTK-150/L

GTK-220/L

GTK-400/L

GTK-600/L

Differential

separate mount

85 - 125

34 - 50

Setting ranges(A) : 5 ~ 60A

Class10A GMP40

39 - 57 43 - 65 54 - 80 65 - 100

GTK-85/L

8 - 40

Separate mount type

34 - 50

GT- 100

Setting ranges(A) : 16 ~ 80A

Setting ranges (A)

Setting ranges (A)

Bimetallic style Type GT

GTK-85 GTH-85/3 GTH-85

Setting ranges (A) 4 - 20

0.1 - 1.5 1-5 4.4 - 22

�30 adjustable Class 1�

Setting ranges (A)

GTK-40 GTH-40/3 GTH-40

Setting ranges (A)

Type GMP

12 -18 16 - 22 18 - 26 24 - 36 28 - 40

GT-40

GTK-22 GTH-22/3 GTH-22 GTK-22/L

Electronic style

Dimension (mm)

0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4

Class 20

Differential


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.