Leader in Electrics & Automation
The electrical lifetime GMC- 9 - 85
Accessories
GMC- 100 - 800
Auxiliary contact Applying contactors GM-9 to 85 type (9 to 85A frame) AU-1 Side mount 2 pole block
AU-2 Front mount 2 pole block
Mounting type Front mount
Poles
Composition
Type
2 pole
2NO 2NC 1NO+1NC 4NO 3NO+1NC 2NO+2NC 1NO+3NC 4NC 1NO 1NC 1NO 1NC
AU-2
4 pole
AU-4 Front mount 4 pole block
Meta-MEC
Contactors And Overload Relays AC 3 duty (Standard) AC 4 duty (Inching, reverse phase breaking duty)
GM-100 to 800 type (100 to 800A frame)
AU-100 Side mount 2 pole block
Side mount
2 pole
Side mount
2 pole
AU-4
AU-1 AU-100
Mechanical Interlock unit
AC 3 duty (Standard) AC 4 duty (Inching, reverse phase breaking duty)
Type AR - 9 AR - 100 AR - 180 AR - 600
Table T3
Leader in Electrics & Automation
Type designations
Applied contactors GMC(D) - 9 ~ GMC(D) - 85 GMC - 100 ~ GMC - 150 GMC - 180 ~ GMC - 400 GMC - 600 ~ GMC - 800
Mechanical latch unit Type AL - 9 AL - 50 AL - 100
Table T4
Applied contactors GMC - 9 ~ 40 GMC - 50 ~ 85 GMC - 100, 125
Type AL - 150 AL - 220 AL - 400
Applied contactors GMC - 150 GMC - 180, 220 GMC - 300, 400
Surge absorber unit Type AS -11 AS -12 AS -13 AS -14 AS - 1 AS - 2 AS - 3 AS - 4 AS - 5 AS - 6
Table T5
� For your safety, please read user's manual thoroughly before operating. � Contact the nearest authorized service facility for examination, repair, or adjustment. � Please contact qualified service technician when you need maintenance. Do not disassemble or repair by yourself!
Safety Instructions
� Any maintenance and inspection shall be performed by the personnel having expertise concerned. ⓒ 2005.5 LS Industrial Systems Co.,Ltd. All rights reserved.
www.lsis.biz � HEAD OFFICE LS Tower 1026-6, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do 431-848, Korea Tel. (82-2)2034-4870 Fax. (82-2)2034-4713
Electric Equipment
Element Varistor
CR + Varistor
Cheong-Ju Plant #1, Song Jung Dong, Hung Duk Ku, Cheong Ju, 361-720, Korea
Element spec. Varistor 120V Varistor 270V Varistor 470V Varistor 1000V Varistor 120V 0.1μF 100Ϊ Varistor 270V 0.1μF 100Ϊ Varistor 470V 0.1μF 100Ϊ Varistor 120V 0.47μF 100Ϊ Varistor 270V 0.47μF 100Ϊ Varistor 470V 0.47μF 100Ϊ
Applied contactors GMC(D)- 9 ~ GMC - 800
GMC - 9 ~ GMC - 85 GMD - 9 ~ GMD - 85
Lug terminal for contactors Type for 3 Pole
Applying contactors � Global Network
GMC-100, 125 type (100, 125A frame) GMC-150 type (150A frame) GMC-180, 220 type (180, 220A frame) GMC-300, 400 type (300. 400A frame) GMC-600, 800 type (600. 800A frame)
�LS Industrial Systems (Middle East) FZE � �Dubai, U.A.E. Address: P.O.Box-114216, API World Tower, 303B, Sheikhe Zayed Road, Dubai, U.A.E. Tel: 971-4-332-8289 Fax: 971-4-332-9444 e-mail: hwyim@lsis.biz
�Dalian LS Industrial Systems Co., Ltd. � �Dalian, China Address: No.15, Liaohexi 3-Road, Economic and Technical Development zone, Dalian 116600, China Tel: 86-411-8273-7777 Fax: 86-411-8730-7560 e-mail: lixk@lsis.com.cn
�LS Industrial Systems (Wuxi) Co., Ltd. � �Wuxi, china
� CHEONG-JU PLANT
Operation voltage AC/DC 24 ~ 48V AC/DC 100 ~ 125V AC/DC 200 ~ 240V AC 380 ~ 440V AC 24 ~ 48V AC 100 ~ 125V AC 200 ~ 240V DC 24 ~ 48V DC 100 ~ 125V DC 200 ~ 220V
Address: 102-A , National High & New Tech Industrial Development Area, Wuxi, Jiangsu,214028, P.R.China Tel: 86-510-8534-6666 Fax: 86-510-522-4078 e-mail: xuhg@lsis.com.cn
�LS-VINA Industrial Systems Co., Ltd. � �Hanoi, Vietnam
AJ125 (70821614008) AJ150 (70821615008) AJ220 (70821616008) AJ400 (70821617008) AJ800 (70821618008)
Address: Nguyen Khe - Dong Anh - Ha Noi - Viet Nam Tel: 84-4-882-0222 Fax: 84-4-882-0220 e-mail: srjo@lsisvina.com
�LS Industrial Systems Tokyo Office � �Tokyo, Japan Address: 16FL, Higashi-Kan, Akasaka Twin Tower 17-22, 2-chome, Akasaka, Minato-ku Tokyo 107-8470, Japan Tel: 81-3-3582-9128 Fax: 81-3-3582-2667 e-mail: jschuna@lsis.biz
�LS Industrial Systems Shanghai Office � �Shanghai, China Address: Room E-G, 12th Floor Huamin Empire Plaza, No.726, West Yan'an Road Shanghai 200050, P.R. China Tel: 86-21-5237-9977 (609) Fax: 89-21-5237-7191 e-mail: jinhk@lsis.com.cn
Enclosed type motor starters
�LS Industrial Systems Beijing Office � �Beijing, China Address: B-Tower 17FL.Beijing Global Trade Center B/D. No.36, BeiSanHuanDong-Lu, DongCheng-District,
Type
Beijing 100013, P.R. China Tel: 86-10-5825-6025,7 Fax: 86-10-5825-6026 e-mail: cuixiaorong@lsis.com.cn
W/O push button
�LS Industrial Systems Guangzhou Office � �Guangzhou, China Address: Room 1403,14F,New Poly Tower,2 Zhongshan Liu Road,Guangzhou, P.R. China Tel: 86-20-8326-6764 Fax: 86-20-8326-6287 e-mail: linsz@lsis.com.cn
�LS Industrial Systems Chengdu Office � �Chengdu, China Address: 12Floor, Guodong Buiding, No52 Jindun Road Chengdu, 610041, P.R. China Tel: 86-28-8612-9151 Fax: 86-28-8612-9236 e-mail: yangcf@lsis.com.cn
�LS Industrial Systems Qingdao Office � �Qingdao, China
Specifications in this catalog are subject to change without notice due to continuous product development and improvement.
2009. 01
Address: 7B40,Haixin Guangchang Shenye Building B, No.9, Shandong Road Qingdao 26600, P.R. China Tel: 86-532-8501-6568 Fax: 86-532-583-3793 e-mail: lirj@lsis.com.cn
Contactors And Overload Relays(E) 2005. 05/(16) 2009. 01 Printed in Korea STAFF
(Metal)
(Mould)
GMW - 9(M) GMW - 12(M) GMW - 18(M) GMW - 22(M) GMW - 32 GMW - 40 GMW - 50 GMW - 65 GMW - 75 GMW - 85
With push button
GMW - 9(M)B GMW - 12(M)B GMW - 18(M)B GMW - 22(M)B GMW - 32B GMW - 40B GMW - 50B GMW - 65B GMW - 75B GMW - 85B
lth (A) 20 25 30 32 45 50 70 80 90 100
Single phase 115V 230V 0.5 1 0.5 2 1 3 2 3 2 5 3 5 3 7.5 5 10 5 15 7.5 15
Rated power (HP) Three phase 200V 230V 460V 2 2 5 3 3 7.5 5 5 10 7.5 7.5 10 7.5 10 20 10 10 25 10 15 30 15 20 40 20 25 50 25 30 60
575V 7.5 10 15 15 20 25 30 40 50 60
Frame size
9A
12A
18A
22A
32A
40A
50A
65A
75A
85A
Frame size
3-pole Contactors
Types AC coil DC coil Ratings / IEC60947-4 AC1 AC3 200/240V 380/440V 500/550V 690V Ratings / UL508 continuous current single phase 115V 230V three phase 200V 230V 460V 575V NEMA size
100A
125A
150A
180A
220A
300A
400A
600A
800A
3-pole Contactors
GMC-9 GMD-9 kW 2.5 4 4 4 hp
GMC-12 GMD-12 A 25 11 9 7 5 A 20
0.5 1 2 2 5 7.5 00
kW
GMC-18 GMD-18 A 25 13 12 12 9 A 25
3.5 5.5 7.5 7.5 hp
kW 4.5 7.5 7.5 7.5 hp
0.5 2 3 3 7.5 10 00
1 3 5 5 10 15 0
GMC-22 GMD-22 A 40 18 18 13 9 A 30
kW 5.5 11 15 15 hp 2 3 7 7.5 10 15 0
GMC-32 GMD-32 A 40 22 22 22 18 A 32
kW
GMC-40 GMD-40 A 50 32 32 28 20 A 45
7.5 15 18.5 18.5 hp
kW 11 18.5 22 22 hp
2 5 7.5 10 20 20 1
GMC-50 GMD-50 A 60 40 40 32 23 A 50
3 5 10 10 25 25 1
kW
GMC-65 GMD-65 A 80 55 50 43 28 A 70
15 22 30 30 hp 3 7.5 10 15 30 30 2
kW
GMC-75 GMD-75 A 100 65 65 60 35 A 80
18.5 30 33 33 hp
kW 22 37 37 37 hp
5 10 15 20 40 40 2
GMC-85 GMD-85 A 110 75 75 64 42 A 90
5 15 20 25 50 50 2
kW 25 45 45 45 hp
A 135 85 85 75 45 A 100
7.5 15 25 30 50 50 3
Additional auxiliary contacts
Types
AC/DC common coil
Ratings / IEC60947-4
GMC-100 kW
GMC-125 A
AC1
kW
160
AC3
200/240V
30
105
380/440V
55
500/550V
55
690V
55 hp
Ratings / UL508 continuous current
GMC-180
kW
A
160 37
125
105
60
85
60
65
60
A
hp
160
115V
7.5
150
120
75
90
90
70
90
A
hp
10
230V
15
three phase
200V
30
230V
30
40
460V
60
575V
kW
GMC-220 A
210 45
160
single phase
NEMA size
GMC-150 A
kW
GMC-300 A
230
kW
GMC-400 A
275
kW
GMC-600 A
350
kW
GMC-800 A
450
kW
A
660
900
55
180
75
250
90
300
125
400
190
630
220
800
150
90
180
132
250
160
300
220
400
330
630
440
800
140
110
180
132
200
160
250
225
350
330
500
500
720
100
110
120
132
150
200
220
250
300
330
420
500
630
A
hp
A
hp
A
hp
A
hp
A
hp
A
hp
210
230
275
350
450
900
15
15
15
20
25
30
40
40
40
60
50
60
75
100
150
200
300
75
100
125
150
200
300
400
600
60
75
100
125
150
200
300
400
600
3
3
4
4
4
5
5
6
7
60
100
125
A
660
150
250
Additional auxiliary contacts 2-pole Front mount
4-pole Front mount
2-pole Side mount
2-pole Front mount
4-pole Front mount
2-pole Side mount
AU-100 1NO+1NC, Side mount
AU-100 1NO+1NC, Side mount
4-pole Contactors 4-pole Contactors Types
AC coil DC coil
AC1(A)
GMC-9/4 GMD-9/4 20
GMC-12/4 GMD-12/4 20
GMC-18/4 GMD-18/4 25
GMC-22/4 GMD-22/4 32
GMC-32/4 GMD-32/4 50
GMC-40/4 GMD-40/4 60
GMC-50/4 GMD-50/4 80
GMC-65/4 GMD-65/4 100
GMC-75/4 GMD-75/4 110
GMC-85/4 GMD-85/4 135
Types
AC/DC common coil
AC1(A)
GMC-100/4
GMC-125/4
GMC-150/4
GMC-180/4
GMC-220/4
GMC-300/4
GMC-400/4
GMC-600/4
GMC-800/4
160
160
210
230
275
350
450
660
900
Overload Relays Setting ranges (A)
Bimetallic style Type GT
GT-22
Class10A Class 20
Differential Non-differential (3-heater) Non-differential (2-heater) Differential
4-6 5-8 6-9 7 - 10 9 - 13 12 - 16 16 - 22
Setting ranges (A) 4-6 5-8 6-9 7 - 10 9 - 13
Base for separate mount
GMP22
Base for separate mount
7 - 10 9 - 13 12 -18 16 - 22 18 - 26 24 - 36
Overload Relays
28 - 40 34 -50 45 - 65 54 - 75 63 - 85 Base for separate mount
GT-85
GTK-40/L
GMP80
Separate mount Wiring by screw
GT- 150
Setting ranges (A)
39 - 57 43 - 65 54 - 80 65 - 100
65 - 100 85 - 125 100 - 150
85 - 125 100 - 150 120 - 180
120 - 180
160 - 240
85 - 125 100 - 150
GT- 220
160 - 240
Setting ranges (A)
GT- 400
GMP60
Separate mount Wiring by CT tunnel
Setting ranges (A) 220 - 300 260 - 400 400 - 600 520 - 800
220 - 300 260 - 400 GT- 800
GTK-100
GTK-150
GTK-220
GTK-400
GTK-600
Non-differential (3-heater)
GTH-100/3
GTH-150/3
GTH-220/3
GTH-400/3
GTH-600/3
Non-differential (2-heater)
GTH-100
GTH-150
GTH-220
GTH-400
GTH-600
GTK-100/L
GTK-150/L
GTK-220/L
GTK-400/L
GTK-600/L
Differential
separate mount
85 - 125
34 - 50
Setting ranges(A) : 5 ~ 60A
Class10A GMP40
39 - 57 43 - 65 54 - 80 65 - 100
GTK-85/L
8 - 40
Separate mount type
34 - 50
GT- 100
Setting ranges(A) : 16 ~ 80A
Setting ranges (A)
Setting ranges (A)
Bimetallic style Type GT
GTK-85 GTH-85/3 GTH-85
Setting ranges (A) 4 - 20
0.1 - 1.5 1-5 4.4 - 22
�30 adjustable Class 1�
Setting ranges (A)
GTK-40 GTH-40/3 GTH-40
Setting ranges (A)
Type GMP
12 -18 16 - 22 18 - 26 24 - 36 28 - 40
GT-40
GTK-22 GTH-22/3 GTH-22 GTK-22/L
Electronic style
Dimension (mm)
0.1 - 0.16 0.16 - 0.25 0.25 - 0.4 0.4 - 0.63 0.63 - 1 1 - 1.6 1.6 - 2.5 2.5 - 4
Class 20
Differential