WIDE AREA NETWORKS & INTERNET APPLICATIONS
The Networking Magazine
GREECE 2022
7th Unified Communications and Collaboration Conference
GREECE 2022
10th Data Center Infrastructures Networking & Services Conference
Your Secure Network Integrator
Cloud WiFi
United Telecom Õðçñåóßåò: n n n n n
Managed Service Provider (MSP) Secure Wired & Wireless Networks – SD-WAN/LAN Remote Access Authentication & Teleworking/WFH CISSP Risk Assessment, Forensics & Security Policy Telecom Optimized Solutions
UNITED TELECOM A.E. ÐåñéêëÝïõò 29 ÃÝñáêáò, 15344 ÁèÞíá – Ôçë. 210.6085599 www.united-telecom.gr – info@united-telecom.gr
ÐÅÑÉÅ×ÏÌÅÍÁ
ISSN 1109-1487
WIDE AREA NETWORKS & INTERNET APPLICATIONS
ÐÅÑÉÅ×ÏÌÅÍÁ
4
ÄéáöïñÝò ìåôáîý âéïìç÷áíéêþí & óõìâáôéêþí óõóôçìÜôùí UPS ¢ñèñï ôïõ Íéêüëáïõ ÓôÞèïõ
ÓõóôÞìáôá CAN-BUS
12 Êùäéêüò 5333
óôçí ðåñéâáëëïíôéêÞ äéá÷åßñéóç Data Centers ¢ñèñï ôïõ ÈÜíïõ Äáæåëßäç
ÅÔÏÓ 23o - Spring 2022 ÉÄÉÏÊÔÇÓÉÁ: Í.Á. ÉÙÁÍÍÉÄÇÓ ÌïõôáëÜóêç 53,
18
ÅöáñìïãÝò Ìðáôáñéþí Ëéèßïõ óôá Data Centers ¢ñèñï ôïõ Èåüäùñïõ ÈåïäùñÞ
Ô.È. 50904 ÊáëïãñÝæá, Ô.Ê. 142 03 Ôçë.: 6977282416 e-mail: info@comsol.gr
Ethernet Åíüò Æåýãïõò
26 ÅÊÄÏÔÇÓ - ÄÉÅÕÈÕÍÔÇÓ: ÍÉÊÏËÁÏÓ Á. ÉÙÁÍÍÉÄÇÓ
ÄÇÌÉÏÕÑÃÉÊÏ/Ó×ÅÄÉÁÓÌÏÓ: ÊÁÑÏÕÓÏÓ adv ÐñáîéôÝëïõò 131, ÐåéñáéÜò Ôá åíõðüãñáöá Üñèñá äåí åêöñÜæïõí áðáñáßôçôá êáé ôéò áðüøåéò ôïõ ðåñéïäéêïý.
2
COMMUNICATION SOLUTIONS
Ç ÍÝá Ðñáãìáôéêüôçôá óôçí Âéïìç÷áíßá ¢ñèñï ôïõ ÄçìÞôñç Öéëßððïõ
36
Cloud Video Services Features 2022 Åßäç óõóêÝøåùí êáé ìÝèïäïé ðñüóâáóçò ÌÝñïò 1
¢ñèñï ôïõ Äéïíýóç ÆÝñâá
SPRING 2022
Power Systems
ÄéáöïñÝò ìåôáîý âéïìç÷áíéêþí & óõìâáôéêþí óõóôçìÜôùí UPS
¢ñèñï ôïõ Íéêüëáïõ ÓôÞèïõ Çëåêôñïëüãïò Ìç÷áíéêüò Power Sales e-mail: nstithos@powerservices.gr
Ð
áñüëï ðïõ ôá óõóôÞìáôá on-line UPS åßíáé åõñÝùò äéáèÝóéìá åäþ êáé ó÷åäüí 40 ÷ñüíéá, ç áãïñÜ ìïíÜäùí äõíáìéêüôçôáò 5 -150 kVA ðáñïõóéÜæåé óôáèåñÞ áýîçóç ôçò ôÜîåùò ôïõ 12% åôçóßùò. Ïé åðé÷åéñÞóåéò êáé ç âéïìç÷áíßá åîáñôþíôáé üëï êáé ðåñéó-
óüôåñï áðü ôç óõíå÷Þ ñïÞ øçöéáêþí äåäïìÝíùí êáèéóôþíôáò ôçí õðïóôÞñéîç áðü ìïíÜäåò UPS ìßá áðü ôéò ðéï æùôéêÝò ðñïûðïèÝóåéò ãéá ôç âéùóéìüôçôá êÜèå ôïìÝá. ÐáñáêÜôù èá áíáëõèïýí ïé âáóéêÝò äéáöïñÝò ìåôáîý Âéïìç÷áíéêþí & Óõìâáôéêþí ÓõóôçìÜôùí UPS êáèþò êáé ôï åýñïò ôùí åöáñìïãþí ðïõ êáëýðôïõí. Ôá ðåäßá åöáñìïãþí ôùí óõóôçìÜôùí on-line
ñåß íá äéáôáñÜîåé ôçí åðåîåñãáóßá äåäïìÝ-
UPS ìðïñïýí íá ôáîéíïìçèïýí óå ôñåéò êýñéåò
íùí êáé êáôÜ óõíÝðåéá ôçí ñïÞ åñãáóéþí.
êáôçãïñßåò:
4
l ÕðïóôÞñéîç Êñßóéìùí Öïñôßùí: Ìå ôçí ðÜñï-
l Ôå÷íïëïãßá Ðëçñïöïñéþí: Ï üñïò «Com-
äï ôùí åôþí, ôá óõóôÞìáôá UPS ðïõ Ý÷ïõí
mercial UPS» Ý÷åé óõíäåèåß ìå ôïí ôïìÝá ôçò
ó÷åäéáóôåß ãéá ôçí õðïóôÞñéîç êñßóéìùí
Ôå÷íïëïãßáò Ðëçñïöïñéþí (IT) êáèþò êáé
öïñôßùí, Ý÷ïõí ÷áñáêôçñéóôåß ùò «Industrial
üëåò ôéò åãêáôáóôÜóåéò ðïõ áöïñïýí Ýíá
UPS». Óå áõôïýò ôïõò ôýðïõò åöáñìïãþí ç
Computer Room. Ôá ÊÝíôñá ÄåäïìÝíùí óå
äéáêïðÞ ôçò ðáñï÷Þò éó÷ýïò ìðïñåß íá ðñï-
ôñÜðåæåò, íïóïêïìåßá êáé áóöáëéóôéêÝò å-
êáëÝóåé áóôÜèåéá óå åðéêßíäõíåò ÷çìéêÝò
ôáéñåßåò áðïôåëïýí ôõðéêÜ ðáñáäåßãìáôá å-
äéåñãáóßåò Þ éäéáéôÝñùò êïóôïâüñåò âëÜâåò
öáñìïãþí IT UPS êáèþò ç äéáêïðÞ ðáñï-
óôá óõóôÞìáôá åðåîåñãáóßáò. Ôá ðåôñï÷ç-
÷Þò éó÷ýïò óôá õðïóôçñéæüìåíá öïñôßá ìðï-
ìéêÜ óõãêñïôÞìáôá êáé ïé óôáèìïß ðáñá-
COMMUNICATION SOLUTIONS
SPRING 2022
Power Systems
ãùãÞò çëåêôñéêÞò åíÝñãåéáò áðïôåëïýí ÷á-
Computer Rooms åßíáé ðñïóôáôåõìÝíá áðü
ñáêôçñéóôéêÜ ðáñáäåßãìáôá âéïìç÷áíéþí
ðáñåìâïëÝò ôýðïõ EMI/RFI. ÂÜóåé ôùí ðñïäéá-
ðïõ êÜíïõí ÷ñÞóç ÷çìéêþí Þ áôìïìç÷áíþí
ãñáöþí ôçò IEEE áðáéôåßôáé ðñïóôáóßá ìå ÷ñÞ-
üðïõ åëëï÷åýïõí óïâáñïß êßíäõíïé óå ðåñé-
óç åðéôçñçôþí ôÜóçò áëëÜ êáé ìåôáó÷çìáôé-
ðôþóåéò äéáêïðÞò ðáñï÷Þò éó÷ýïò óôá óõ-
óôþí áðïìüíùóçò ÁóôÝñá-Ôñéãþíïõ óôçí êý-
óôÞìáôá åëÝã÷ïõ ôïõò. Ëüãù ôùí êéíäýíùí
ñéá åßóïäï ôñïöïäïóßáò ôïõ UPS. Ï ó÷åäéá-
áõôþí ôá óõóôÞìáôá UPS ðïõ ðñïïñßæïíôáé
óìüò ôïõ óõóôÞìáôïò äéáíïìÞò éó÷ýïò åíüò
ãéá âéïìç÷áíéêÝò åöáñìïãÝò ðñÝðåé íá ó÷å-
Data Center ðñïóôáôåýåé ôï UPS áðü ôéò åðé-
äéÜæïíôáé êáé íá åëÝã÷ïíôáé óå ðéï áõóôçñü
ðôþóåéò ôùí åðåñ÷üìåíùí Çëåêôñïìáãíçôéêþí
åðßðåäï.
Ðáñåìâïëþí êáé Ðáñåìâïëþí Ñáäéïóõ÷íïôÞ-
l ¸ëåã÷ïò Ãåíéêþí Äéåñãáóéþí: ÕðÜñ÷ïõí å-
ôùí (EMI/RFI) óôçí êýñéá ôñïöïäïóßá êáèþò
öáñìïãÝò ðïõ åìðßðôïõí óå ìßá ìÝóç êáôç-
êáé ôçí åßóïäï ôïõ Bypass.
ãïñßá ðïõ ÷áñáêôçñßæåôáé ùò «ÅëáöñÜ Âéï-
Ç ÷ñÞóç áíåîÜñôçôçò ôñïöïäïóßáò éó÷ýïò
ìç÷áíßá». Áõôïß ïé ôýðïé åöáñìïãþí áöï-
åéóüäïõ óå óõíäõáóìü ìå ôïõò ìåôáó÷çìáôé-
ñïýí äéåñãáóßåò ÷áìçëÞò åðéêéíäõíüôçôáò
óôÝò áðïìüíùóçò, ü÷é ìüíï ðåñéïñßæåé ôéò ðá-
óå ðåñßðôùóç äéáêïðÞò ðáñï÷Þ éó÷ýïò.
ñåìâïëÝò ÅÌÉ/RFI, áëëÜ êáé ôï åðéóöáëÝò ñåý-
Ùóôüóï, ç áðïôõ÷ßá õðïóôÞñéîçò áðü ìßá
ìá óôï äßêôõï ôñïöïäïóßáò ôïõ UPS.
ìïíÜäá UPS ìðïñåß íá ðñïêáëÝóåé êáèõ-
Ôï Ó÷Þìá 2 áíáðáñéóôÜ ôçí ôõðéêÞ äéÜôáîç á-
óôÝñçóç ôçò ðáñáãùãéêÞò äéáäéêáóßáò ùò
íïñèùôÞ Âéïìç÷áíéêïý UPS ìå ÷ñÞóç ìåôá-
áðïôÝëåóìá ôùí áíèñùðïùñþí ðïõ áðáé-
ó÷çìáôéóôÞ áðïìüíùóçò åéóüäïõ. Óå ïñéóìÝ-
ôïýíôáé ãéá ôçí åðáíáöïñÜ ôïõ åîïðëéóìïý
íåò âéïìç÷áíéêÝò åöáñìïãÝò, ç åßóïäïò ôïõ
ðáñáãùãÞò. Ïé öáñìáêåõôéêÝò åôáéñåßåò êáé
UPS
ïé âéïìç÷áíßåò ôñïößìùí êáé ðïôþí áðïôå-
ÌåôáãùãÞò/ÊéíçôÞñá (MCC - Motor Control
ëïýí ÷áñáêôçñéóôéêü ðáñÜäåéãìá ôçò Åëá-
Centers) êáé óõ÷íÜ ãßíåôáé ÷ñÞóç êïéíþí óõí-
öñÜò Âéïìç÷áíßáò.
äÝóåùí äéáýëïõ ìå çëåêôñéêÜ öïñôßá õøçëïý
ôñïöïäïôåßôáé ìÝóù ÊÝíôñùí ÅëÝã÷ïõ
èïñýâïõ üðùò ãéá ðáñÜäåéãìá ïé êéíçôÞñåò ÐáñåìâïëÝò EMI/RFI & ÕðÝñôáóç IT
ìåôáâëçôþí óôñïöþí. ¸íáò ìåôáó÷çìáôéóôÞò
Óôï Ó÷Þìá 1 áíáðáñßóôáôáé ç ôõðéêÞ äéÜôáîç
áðïìüíùóçò åéóüäïõ ìðïñåß íá åßíáé áðáñáß-
åíüò Data Center üðïõ åßíáé åìöáíÝò ðùò ôá
ôçôïò óôï âéïìç÷áíéêü ðåñéâÜëëïí ãéá ôçí ðñï-
Electric Utility
Meter
Lighting Arestor
Building Distribution Enviromental System
ATS Life Safety
Stanby Generator
Critical Power Distribution Center Critical Load
UPS Battery
Power Center
Monitoring System Ó÷Þìá 1. ÔõðéêÞ äéÜôáîç Data Center SPRING 2022
COMMUNICATION SOLUTIONS
5
Power Systems
Control
Inverter
STS Manual Bypass Switch
Isolation Transformer
Ó÷Þìá 2. ÔõðéêÞ ÄéÜôáîç Âéïìç÷áíéêïý UPS ìå Ìåôáó÷çìáôéóôÞ Áðïìüíùóçò Åéóüäïõ
óôáóßá ôïõ UPS áðü ôéò åðéðôþóåéò ôùí ðáñåì-
êÝò áíôéäéáâñùôéêÝò ôåñìáôéêÝò óõíäÝóåéò êáé
âïëþí ôñïöïäïóßáò éó÷ýïò êáé RFI/EMI.
ìåôáëëéêÝò åðéöÜíåéåò ìå åðßóôñùóç áíèåêôéêÞ óôçí ïîåßäùóç. ÁíÜ ðåñßðôùóç, ï áÝñáò øýîçò óôá åñìÜñéá ôïõ UPS äéï÷åôåýåôáé ìÝóù ìéáò
Åîùãåíåßò Ðåñéâáëëïíôéêïß ÐáñÜãïíôåò Ðïëëïß ÷þñïé ëåéôïõñãßáò âéïìç÷áíéêþí UPS, éäéáßôåñá óôéò åöáñìïãÝò ðáñáãùãÞò çëåêôñéêÞò åíÝñãåéáò, ðáñïõóéÜæïõí õøçëÝò èåñìïêñáóßåò, (äçë. > 30ïC) êáé åìöáíßæïõí óùìáôéäéáêÞ ñýðáíóç ôïõ áÝñá. Ï âéïìç÷áíéêüò åîï-
êáèáñÞò ðçãÞò õðü èåôéêÞ ðßåóç êáé áíáëþíåôáé þóôå íá ìçí ìåôáöåñèïýí ñýðïé óôï åóùôåñéêü ôïõ UPS. Áíôßèåôá, ïé ÷þñïé åöáñìïãþí IT UPS Ý÷ïõí ó÷åäüí ðÜíôá óôáèåñÞ èåñìïêñáóßá < 30ïC
ðëéóìüò UPS Ý÷åé ó÷åäéáóôåß ãéá íá áíÝ÷åôáé
êáé äéáôçñïýíôáé êáèáñïß.
ìÝôñéåò ðïóüôçôåò ìç áãþãéìçò óêüíçò êáé õ-
Ç äéÜñêåéá æùÞò ïðïéïõäÞðïôå óõóôÞìáôïò
øçëÝò èåñìïêñáóßåò ÷þñïõ, ôïõëÜ÷éóôïí 40 C.
UPS ìåéþíåôáé ìå ôç ëåéôïõñãßá õðü õøçëÝò
Ïé ãåùèåñìéêïß óôáèìïß ðáñáãùãÞò çëåêôñé-
èåñìïêñáóßåò ðåñéâÜëëïíôïò êáé ôï ôìÞìá ðïõ
ï
êÞò åíÝñãåéáò óõ÷íÜ ðáñÜãïõí ùò áÝñéï, õðïðñïúüí äéïîåéäßïõ ôïõ èåßïõ ìå óõíÝðåéá ôïí ó÷çìáôéóìü áñáéùìÝíïõ èåééêïý ïîÝïò, üôáí áõôü áíáìé÷èåß ìå ôçí õãñáóßá óôïí áÝñá. Ôá âéïìç÷áíéêÜ óõóôÞìáôá UPS ðïõ ó÷åäéÜæïíôáé
åðçñåÜæåôáé ðåñéóóüôåñï åßíáé ïé óõóóùñåõôÝò êáèþò êáé Üëëá åóùôåñéêÜ åîáñôÞìáôá ôïõ UPS üðùò ïé ðõêíùôÝò öéëôñáñßóìáôïò ôïõ äéáýëïõ DC (DC BUS) - åêôüò åÜí åðéëåãïýí åéäéêïß ðõêíùôÝò õøçëÞò èåñìïêñáóßáò.
ãéá ãåùèåñìéêÝò åöáñìïãÝò äéáèÝôïõí âåñíéêùìÝíåò åðéíéêåëùìÝíåò ìðÜñåò ÷áëêïý, åéäé-
ÄéáôÜîåéò Óôáôéêþí Äéáêïðôþí - Õâñéäéêüò ¸íáíôé Çëåêôñïíéêïý Ôï Ó÷Þìá 3 áíáðáñéóôÜ ôçí ôïðïèÝôçóç êáèþò êáé ôç äéÜôáîç åíüò ôõðéêïý Õâñéäéêïý Óôáôéêïý Äéáêüðôç. Ç õâñéäéêÞ óôáôéêÞ äéáìüñöùóç äéáêïðôþí ÷ñçóéìïðïéåßôáé ðïëý óõ÷íÜ óôá óõóôÞìáôá IT UPS üðïõ ìüíï ç åðáöÞ Bypass ôïõ óôáôéêïý äéáêüðôç êÜíåé ÷ñÞóç ôïõ áíôßóôñïöïõ-ðáñÜëëçëïõ æåýãïõò èõñßóôïñ (SCR) ãéá ôç ìåôáãùãÞ éó÷ýïò. Ç åðáöÞ Inverter ôïõ õâñéäéêïý óôáôéêïý äéáêüðôç ÷ñçóéìïðïéåß Ýíáí
Åéêüíá 1: ÔõðéêÞ ÄéÜôáîç Âéïìç÷áíéêïý UPS 6
COMMUNICATION SOLUTIONS
çëåêôñïíüìï ìå normally open åðáöÝò ãéá íá SPRING 2022
Power Systems
STS
From the Bypass
Inverter From the Inverter Small Charger
Inverter side Contactor
Ó÷Þìá 3: IT UPS ìå ÔõðéêÞ ÄéÜôáîç Ôõðéêïý Õâñéäéêïý Óôáôéêïý Äéáêüðôç
áðïóõíäÝóåé ôïí Inverter áðü ôo Bypass êáôÜ
ôéêüò äéáêüðôçò ìåóïëáâåß ìåôáîý ôïõ Inverter
ôç äéÜñêåéá ôçò óôáôéêÞò ìåôáãùãÞò êñßóéìïõ
êáé ôïõ êñßóéìïõ öïñôßïõ.
öïñôßïõ. Ïé çëåêôñïíüìïé äåí åßíáé ôüóï áîéü-
Ôï Ó÷Þìá 4 áíáðáñéóôÜ ôç äéÜôáîç åíüò ôõðé-
ðéóôïé üóï ïé óõóêåõÝò èõñßóôïñ, åéäéêÜ åÜí ï
êïý Çëåêôñïíéêïý Óôáôéêïý Äéáêüðôç. ¼ðùò
Inverter åêôßèåôáé óå åðáíáëáìâáíüìåíá óöÜë-
áíáöÝñèçêå ðñïçãïõìÝíùò, ç ÷ñÞóç èõñß-
ìáôá öïñôßïõ.
óôïñ êáé óôïõò äýï ðüëïõò ôïõ óôáôéêïý äéá-
Õðü êáèåóôþò óöÜëìáôïò êñßóéìïõ öïñôßïõ
êüðôç äçìéïõñãåß ìéá ðéï áîéüðéóôç äéáäñïìÞ
óôçí Ýîïäï ôïõ UPS, ôï ñåýìá âñá÷õêõêëþìá-
éó÷ýïò åîáëåßöïíôáò ôçí åðáöÞ Inverter ôïõ
ôïò ðåñéïñßæåôáé ìüíï áðü ôçí åìðÝäçóç ôçò
çëåêôñïíüìïõ. ÏñéóìÝíá âéïìç÷áíéêÜ óõóôÞ-
ðçãÞò ôïõ Bypass. ÅÜí ïé õâñéäéêÝò åðáöÝò
ìáôá UPS äéáèÝôïõí äýï óôáôéêÝò ëåéôïõñ-ãßåò
ôïõ óôáôéêïý äéáêüðôç ôïõ UPS äåí áíïßîïõí,
äéáêïðôþí ìåôáãùãÞò áíÜëïãá ìå ôçí êáôÜ-
ç Ýîïäïò ôïõ UPS èá óõíäÝåôáé óõíå÷þò ìå
óôáóç ôïõ óõã÷ñïíéóìïý öÜóçò Inverter êáé
ôçí ðçãÞ Bypass. Ïé Inverters ôùí UPS, åéäéêÜ
Bypass. ÅÜí ôï Bypass êáé ï Inverter âñßóêï-
ïñéóìÝíïé PWM Inverters, äåí Ý÷ïõí ó÷åäéáóôåß
íôáé óå óõã÷ñïíéóìü öÜóçò, ï óôáôéêüò äéá-
þóôå ïé AC Ýîïäïß ôïõò íá ôñïöïäïôïýíôáé
êüðôçò åêôåëåß ìéá åðéêáëõðôüìåíç ìåôáöï-
áðü ôï Bypass ãéá ðåñéóóüôåñá áðü 30 - 50
ñÜ (make-before-break). ÅÜí ôï Bypass êáé ï
msec.
Inverter äåí óõã÷ñïíéóôïýí óôáäéáêÜ êáé ôï
Ôá âéïìç÷áíéêÜ óõóôÞìáôá UPS ÷ñçóéìïðïé-
öïñôßï ôïõ UPS õðåñâáßíåé ôçí áíï÷Þ ôïõ
ïýí óõóêåõÝò èõñßóôïñ ôüóï óôïõò ðüëïõò ôïõ Inverter üóï êáé óôïõò ðüëïõò ôïõ Bypass. Äåí ÷ñçóéìïðïéïýí ôçí ðëåõñéêÞ åðáöÞ ôïõ Inverter, áëëÜ áíôßèåôá ÷ñçóéìïðïéïýí Ýíá ðñüóèåôï áíôßóôñïöï ðáñÜëëçëï æåýãïò èõñßóôïñ. ÁõôÞ ç ôñïðïðïßçóç óôïí õâñéäéêü óôá-
Inverter, ï óôáôéêüò äéáêüðôçò èá åêôåëÝóåé ìéá ìåôáãùãÞ èñáýóçò 0,25 êýêëùí ãéá íá áðïôñÝøåé ôç äçìéïõñãßá áóõã÷ñüíéóôïõ ñåýìáôïò ñïÞò. Áõôüò ï ôñüðïò ëåéôïõñãßáò äéðëÞò óôáôéêÞò ìåôáãùãÞò èá Þôáí áäýíáôïò ÷ùñßò ÷ñÞóç çëåêôñïíéêïý óôáôéêïý äéáêüðôç.
ôéêü äéáêüðôç åßíáé, öõóéêÜ, Ýíá ðéï áêñéâü ó÷åäéáóôéêü ÷áñáêôçñéóôéêü, áëëÜ ç åîÜëåéøç
Äéêëßäåò Áóöáëåßáò UPS
ôïõ çëåêôñïíüìïõ áõîÜíåé ôçí áîéïðéóôßá ôïõ
Óå ðåñßðôùóç áóôï÷ßáò ôçò ôñïöïäïóßáò ôïõ
óôáôéêïý äéáêüðôç. Ôï MTBF (ìÝóïò ÷ñüíïò ìå-
óôáôéêïý äéáêüðôç ÷Üíåôáé ç äõíáôüôçôá õðï-
ôáîý áðïôõ÷ßáò) ôïõ UPS óõíäÝåôáé ìå ôçí á-
óôÞñéîçò ôùí êñßóéìùí öïñôßùí óå ðåñßðôùóç
îéïðéóôßá ôïõ óôáôéêïý äéáêüðôç, êáèþò ï óôá-
áóôï÷ßáò ôçò êýñéáò ðçãÞò ôñïöïäïóßáò êá-
SPRING 2022
COMMUNICATION SOLUTIONS
7
Power Systems R
FU Sync
SCR
R
SCR
R Voltage Sense
SCR
SCR
R Load
Under Voltage Input
Alternate Source AC Input
Current Sense
Inverter
PB
Reed Relay Coil “R” PB
Logic Circuit PC PC
Bridge Sensing
Over Current Input
Ó÷Þìá 4: ÄéÜôáîç Ôõðéêïý Âéïìç÷áíéêïý Çëåêôñïíéêïý Óôáôéêïý Äéáêüðôç
8
èþò ôï èõñßóôïñ äåí äÝ÷åôáé ðëÝïí ôçí áðá-
îåñãáóôÞ, ôüóï ï åóùôåñéêüò üóï êáé ï åîù-
ñáßôçôç éó÷ý ãéá íá ëåéôïõñãÞóåé óùóôÜ.
ôåñéêüò åðéôçñçôÞò ðáñáêïëïõèïýí óõíå÷þò
Åßíáé óýíçèåò ðëÝïí óôéò ìÝñåò ìáò ôá óõóôÞ-
ôéò äéåñãáóßåò ôïõ ìéêñïåðåîåñãáóôÞ þóôå óå
ìáôá UPS íá ÷ñçóéìïðïéïýí ìéêñïåðåîåñãá-
ðåñßðôùóç óöÜëìáôïò, ôï UPS, ìÝóù ôïõ áíå-
óôÝò ãéá ôïí Ýëåã÷ï ôùí ëåéôïõñãéþí ôïõò üðïõ
îÜñôçôïõ óôáôéêïý äéáêüðôç íá ìåôáöÝñåé Ü-
äõóôõ÷þò, åÜí äåí Ý÷åé ðñïâëåöèåß ï ðåñéïñé-
ìåóá ôï êñßóéìï öïñôßï óôï Bypass.
óìüò ôïõ åýñïõò ôùí äéåñãáóéþí ðïõ åðéôåëåß
Ï ÷åéñïêßíçôïò äéáêüðôçò Bypass (MBS) äßíåé
ï ìéêñïåðåîåñãáóôÞò åíüò UPS, óå ðåñßðôùóç
ôç äõíáôüôçôá ìåôáöïñÜò ôïõ êñßóéìïõ öïñ-
áóôï÷ßáò ôïõ åðÝñ÷åôáé ðëÞñçò êáôÜññåõóç
ôßïõ óôçí ðçãÞ bypass ìå óêïðü ôç äéåíÝñãåéá
ôïõ óõóôÞìáôïò.
åñãáóéþí óõíôÞñçóçò êáé åðéóêåõþí. Óå Ýíá IT
Óå óõóôÞìáôá UPS ðïõ äåí Ý÷ïõí åîåôáóôåß
UPS, ç ÷åéñïêßíçôç ðáñÜêáìøç óõíÞèùò åêôå-
ðéèáíÝò óçìåéáêÝò áóôï÷ßåò (SPOF), ç áóôï÷ßá
ëåßôáé ìÝóù åíüò åîùôåñéêïý ìåôáãùãéêïý äéá-
ôïõ ßäéïõ ôïõ ìéêñïåðåîåñãáóôÞ Ý÷åé ùò óõ-
êüðôç êõêëþìáôïò. Ç ìåôáãùãÞ ôçò ôñïöïäï-
íÝðåéá ü÷é ìüíï ôçí îáöíéêÞ áðþëåéá ôçò åîü-
óßáò ôïõ öïñôßïõ óôçí ðçãÞ Bypass åðéôõã÷Ü-
äïõ ôïõ UPS, áëëÜ êáé ôçí áäõíáìßá ôïõ óôá-
íåôáé êëåßíïíôáò ðñþôá ôï óôáôéêü äéáêüðôç
ôéêïý äéáêüðôç íá ìåôáöÝñåé ôï êñßóéìï öïñôßï
êáé óôç óõíÝ÷åéá êëåßíïíôáò ôï ÷åéñïêßíçôï äéá-
óôï Bypass.
êüðôç Bypass. Åíþ ç ðáñáðÜíù äéáäéêáóßá
Óå Ýíá âéïìç÷áíéêü UPS ïé áóôï÷ßåò ëåéôïõñ-
öáßíåôáé áðëÞ, åîáñôÜôáé åî ïëïêëÞñïõ áðü ôç
ãßáò åîåôÜæïíôáé ðñïóåêôéêÜ êáé åîáëåßöïíôáé,
óùóôÞ ëåéôïõñãßá ôïõ óôáôéêïý äéáêüðôç ôïõ
óôï ìÝôñï ôïõ äõíáôïý. Óå Ýíá ðñïóå÷ôéêÜ
UPS. ÅÜí ï óôáôéêüò äéáêüðôçò äåí ëåéôïõñãÞ-
ó÷åäéáóìÝíï UPS, åëåã÷üìåíï áðü ìéêñïåðå-
óåé, ç ÷åéñïêßíçôç ëåéôïõñãßá ðáñÜêáìøçò ìÝ-
COMMUNICATION SOLUTIONS
SPRING 2022
Power Systems
óù ôïõ ÷åéñïêßíçôïõ äéáêüðôç Bypass äåí èá
îçò ôùí óõóóùñåõôþí ìðïñåß íá êõìáßíïíôáé
åðéôåëåóôåß üðùò ðñïâëÝðåôáé.
áðü 60 ëåðôÜ Ýùò 8 þñåò Þ ðåñéóóüôåñï. Ï ìå-
Ôá âéïìç÷áíéêÜ UPS êÜíïõí ÷ñÞóç åíüò
ëåôçôÞò ôçò åãêáôÜóôáóçò ðñÝðåé íá åëÝãîåé
«make-before-break» ðåñéóôñïöéêïý äéáêüðôç.
ãéá íá âåâáéùèåß üôé ôï óýóôçìá UPS ðïõ åîå-
Ç äéáäéêáóßá ÷åéñïêßíçôçò ðáñÜêáìøçò åßíáé å-
ôÜæåôáé Ý÷åé áñêåôÞ ÷ùñçôéêüôçôá öüñôéóçò
íôåëþò áíåîÜñôçôç áðü ôç ëåéôïõñãßá ôïõ
óõóóùñåõôþí åíóùìáôùìÝíç óôï öïñôéóôÞ,
óôáôéêïý äéáêüðôç. Óå ïñéóìÝíá âéïìç÷áíéêÜ
åéäéêÜ óå âéïìç÷áíéêÝò åöáñìïãÝò üðùò ç ðá-
UPS, ï ÷åéñïêßíçôïò äéáêüðôçò ðáñÜêáìøçò
ñáãùãÞ åíÝñãåéáò üðïõ óõíÞèùò ÷ñçóéìïðïé-
äéáèÝôåé ðñüóèåôåò åðáöÝò ìåôáãùãÞò éó÷ýïò
ïýíôáé óõóóùñåõôÝò UPS áõôïíïìßáò 4-8 ù-
ðïõ áðïìïíþíïõí ôïí óôáôéêü äéáêüðôç áðü ôï
ñþí.
Bypass êáé ôïí Inverter ãéá íá äéåõêïëýíïõí ôéò åñãáóßåò óõíôÞñçóçò.
ÊáôáóêåõÞ êáé Åìðïñßá Âéïìç÷áíéêþí UPS Ýíáíôé IT UPS
ÓõóóùñåõôÝò & Öüñôéóç Óå ãåíéêÝò ãñáììÝò, óôéò åöáñìïãÝò IT UPS ÷ñçóéìïðïéïýíôáé óõóóùñåõôÝò ÌïëýâäïõÏîÝïò åýñïõò áõôïíïìßáò 10-30 ëåðôþí. ÅðåéäÞ ïé ÷ñüíïé áõôïíïìßáò ôùí IT UPS óõíÞèùò äåí åßíáé ôüóï ìåãÜëïé üóï åêåßíïé ôùí âéïìç÷áíéêþí UPS, äåí äßíåôáé ôüóç ìåãÜëç âÜóç óôç ÷ùñçôéêüôçôá ôùí öïñôéóôþí. Ïé öïñôéóôÝò ìðáôáñéþí ôùí IT UPS åßíáé óõíÞèùò åðáñêåßò ãéá íá öïñôßóïõí Ýíáí óõóóùñåõôÞ Ìïëýâäïõ-ÏîÝïò áõôïíïìßáò 15-30 ëåðôþí áðü ôï ìçäÝí óå ðïóïóôü 95% óå 8-10 þñåò. Áíôßèåôá, óôéò âéïìç÷áíéêÝò åöáñìïãÝò, ç ÷ùñçôéêüôçôá ôïõ öïñôéóôÞ óõ÷íÜ ðñÝðåé íá åßíáé ðïëý ìåãáëýôåñç, åðåéäÞ ïé ÷ñüíïé õðïóôÞñé-
Ï âéïìç÷áíéêüò åîïðëéóìüò UPS Ý÷åé åíóùìáôùìÝíá ðåñéèþñéá ó÷åäéáóìïý óôá åîáñôÞìáôÜ ôïõ, Ýôóé þóôå ôï óýóôçìá UPS íá Ý÷åé > 100.000 þñåò MTBF (Mean time between failures) üôáí ëåéôïõñãåß óå ôõðéêÜ âéïìç÷áíéêÜ ðåñéâÜëëïíôá. ÕðÜñ÷ïõí åîáñôÞìáôá üðùò ïé áíåìéóôÞñåò øýîçò êáé ïé ðõêíùôÝò DC ðïõ õðïâáèìßæïíôáé ìå ôï ÷ñüíï, áêüìç êáé ìå óõíôçñçôéêÝò ðñáêôéêÝò ó÷åäéáóìïý. Ïé åöáñìïãÝò Âéïìç÷áíéêþí UPS, üðùò óå õðïóôáèìïýò ðáñáãùãÞò çëåêôñéêÞò åíÝñãåéáò êáèþò êáé óôçí Ðåôñïâéïìç÷áíßá, óõíÞèùò ðñïäéáãñÜöïõí ôç äéÜñêåéá æùÞò ôïõ UPS óôï öÜóìá 20 30 åôþí. Ïé ðñïìçèåõôÝò Âéïìç÷áíéêþí UPS Ý÷ïõí ôåêìçñéùìÝíá ÷ñïíïäéáãñÜììáôá áíôéêáôÜóôáóçò åîáñôçìÜôùí, ãéá ðáñÜäåéãìá áíåìéóôÞñåò øýîçò êáé ðõêíùôÝò DC, Ýôóé þóôå ôï MTBF íá ìðïñåß íá äéáôçñçèåß êáè' üëç ôçí åêôéìþìåíç äéÜñêåéá æùÞò ôçò ìïíÜäáò (20-30 Ýôç). Óçìáíôéêü ñüëï ãéá ôç ìáêñïâéüôçôá ôùí âéïìç÷áíéêþí ìïíÜäùí UPS ðáßæïõí ïé õðçñåóßåò óõìâïëáßùí õðïóôÞñéîçò ðïõ ðñïâëÝðïõí ôáêôéêïýò åëÝã÷ïõò êáé áíôéêáôÜóôáóç áíôáëëáêôéêþí ðáëáéüôåñïõ åîïðëéóìïý. Ïé åôáéñåßåò õðïóôÞñéîçò âéïìç÷áíéêþí UPS ìåñéìíïýí ãéá
Åéêüíá 2: ÅñìÜñéï Óõóóùñåõôþí Âéïìç÷áíéêïý Ôýðïõ SPRING 2022
ôçí åðÜñêåéá óôïê áêüìá êáé óå ìåãÜëï óå âÜèïò ÷ñüíïõ ãéá ôéò åí ëüãù ìïíÜäåò. COMMUNICATION SOLUTIONS
9
Power Systems
Óôçí áãïñÜ ôùí IT UPS ç åðÜñêåéá ìßáò ìï-
Ôå÷íïëïãßåò Inverter - Öåññßôç ¸íáíôé PWM
íÜäáò åîáñôÜôáé Üìåóá áðü ôçí åîÝëéîç ôçò
Ïé Inverters Öåññßôç ÷ñçóéìïðïéïýíôáé óå âéïìç÷áíéêÝò åöáñìïãÝò åäþ êáé ó÷åäüí 40 ÷ñüíéá. Ïé óõãêåêñéìÝíïé Inverters åîáêïëïõèïýí íá ðñïôéìþíôáé ãéá ôéò ðñáãìáôéêÜ áðáéôçôéêÝò åöáñìïãÝò UPS (üðùò óôçí ðõñçíéêÞ åíÝñãåéá) ëüãù ôçò áðëüôçôáò ôïõ êõêëþìáôïò éó÷ýïò êáé ôéò åããåíåßò äéêëßäåò áóöáëåßáò ôïõò.
ôå÷íïëïãßáò, üðïõ åÜí ëçöèåß õðüøç ðùò ôï ìÝóï Data Center áíáâáèìßæåôáé êÜèå 4-5 ÷ñüíéá ãßíåôáé åýêïëá áíôéëçðôü ðùò ï åí ëüãù ôýðïò UPS Ý÷åé ðåñéïñéóìÝíç ÷ñÞóç êáé ó÷åôéêÜ ìéêñü ÷ñüíï æùÞò. ¸ôóé, ïé ðñïìçèåõôÝò IT UPS åðéêåíôñþíïíôáé óôï ó÷åäéáóìü íåüôåñùí ìïíÜäùí êÜèå ôñÝ÷ïõóá ðåñßïäï ìå óôü÷ï ôçí åðßôåõîç ÷áìçëüôåñïõ êüóôïõò ðáñáãùãÞò, ìéêñüôåñïõ üãêïõ êáèþò êáé ìåãáëýôåñçò áîéïðéóôßáò. Ç ôá÷åßá áðáîßùóç ôùí IT UPS êáèéóôÜ ôç ìáêñïðñüèåóìç õðïóôÞñéîç ðáëáéüôåñùí ìïíôÝëùí áñêåôÜ äýóêïëç êáé áóýìöïñç. ¸íáò ìåëåôçôÞò âéïìç÷áíéêþí UPS èá ðñÝðåé êáôÜ ôçí åðéëïãÞ ôçò êáôÜëëçëçò ìïíÜäáò íá ëáìâÜíåé õðüøç ôá ìáêñïðñüèåóìá æçôÞìáôá õðïóôÞñéîçò êáé ôï óõíïëéêü êüóôïò ôïõ êý-
Ïé Inverters PWM Ý÷ïõí ãßíåé ðéï áðïäåêôïß áðü ôïõò ìåëåôçôÝò Âéïìç÷áíéêþí UPS êáôÜ ôçí ôåëåõôáßá äåêáåôßá ëüãù ôùí âåëôéþóåùí óôçí áîéïðéóôßá ôïõò êáé ôçò ôá÷ýôçôáò ìåôáãùãÞò ôçò éó÷ýïò ôùí IGBT. ÁíåîáñôÞôùò ôçò ôå÷íïëïãßáò Inverter ðïõ åðéëÝãåôáé, ï âéïìç÷áíéêüò åîïðëéóìüò UPS èá åßíáé ðÜíôá ðéï áêñéâüò áðü ôïí óõìâáôéêü åîïðëéóìü UPS, êáèþò ïé åöáñìïãÝò ôïõ, üðùò áíáöÝñèçêå åßíáé ðïëý ðéï áðáéôçôéêÝò.
êëïõ æùÞò åíüò UPS, êáèþò óå âéïìç÷áíéêÜ ðåñéâÜëëïíôá, üðïõ åðéôåëïýíôáé éäéáßôåñá áðáéôçôéêÝò äéåñãáóßåò, ï ðñïãñáììáôéóìüò åíüò ôáêôéêïý åëÝã÷ïõ óõíôÞñçóçò êáé ç áíôéêáôÜóôáóç êñßóéìùí áíôáëëáêôéêþí áðïôåëåß ïéêïíïìéêüôåñç ëýóç óå ó÷Ýóç ìå ôçí áíôéêáôÜóôáóç ôïõ ßäéïõ ôïõ UPS.
ÂÉÂËÉÏÃÑÁÖÉÁ Lionel Ardid - "Standard UPS Vs Industrial UPS Systems In Industrial Ápplications" - Ametek "The Essential Differences Between Commercial & Industrial UPS Systems" - Diana Garcia "Light Industrial UPS vs Commercial UPS" - Darcy Stafford "Commercial vs Industrial UPS Systems" -
Ëßãá ëüãéá ãéá ôïí áñèñïãñÜöï Ï ê. Íéêüëáïò ÓôÞèïò åñãÜæåôáé óôçí PowerSales ìå âáóéêü áíôéêåßìåíï ôçí åêðüíçóç çëåêôñïëïãéêþí êáé ìç÷áíïëïãéêþí ó÷åäßùí, Ý÷ïíôáò åíåñãü ñüëï óôá ôìÞìáôá Ôå÷íéêïý êáé R&D ôçò åôáéñåßáò. Ìå ðïñåßá óôï ÷þñï ôïõ Öùôéóìïý ùò ìåëåôçôÞò áðü ôï 2014, Ýêáíå ôç ìåôÜâáóç óôï ÷þñï ôùí ÓõóôçìÜôùí ÁäéÜëåéðôçò ÅíÝñãåéáò óôá ðëáßóéá ôçò öéëïóïößáò ôïõ ðåñß óõíå÷ïýò åîÝëéîçò óôïí ôïìÝá ôçò ôå÷íïëïãßáò. Çëåêôñïëüãïò Ìç÷áíéêüò Ô.Å. ôïõ Åèíéêïý Êáðïäéóôñéáêïý Ðáíåðéóôçìßïõ.
ÅÜí åðéèõìåßôå ôï COMMUNICATION SOLUTIONS íá äçìïóéåýóåé ðåñéóóüôåñá Üñèñá ãéá Power Systems åðéêïéíùíÞóôå ìáæß ìáò óôï: info@comsol.gr
10
COMMUNICATION SOLUTIONS
SPRING 2022
H Lever, üðùò óõíáíôÜôáé óÞìåñá äçìéïõñãÞèçêå ôï 1989, áëëÜ ç éóôïñßá ôçò îåêéíÜ áðü ôï 1973. ÊáôáóêåõÜæåé Øçöéáêïýò ÁíïñèùôÝò - ÖïñôéóôÝò ôå÷íïëïãßáò Thyristor (SCR - Silicon Controlled Rectifiers). ÐñïóöÝñåé ëýóåéò óå áðáéôçôéêÝò âéïìç÷áíéêÝò åöáñìïãÝò üðùò äéõëéóôÞñéá, åñãïóôÜóéá ðáñáãùãÞò åíÝñãåéáò, ìÝóá ìåôáöïñÜò, âéïìç÷áíßá ÷çìéêþí - åîüñõîçò ìåôáëëåõìÜôùí - åðåîåñãáóßáò ìåôÜëëïõ. H óåéñÜ Øçöéáêþí Áíïñèùôþí SME êáëýðôåé Ýíá åõñý öÜóìá áðü 24VDC Ýùò 220VDC ðáñÝ÷ïíôáò óôáèåñÞ êáé êáèáñÞ ôÜóç DC, êõìÜôùóçò <1%RMS êáé áðüäïóçò 92%~94%, ìå äõíáôüôçôá õðïóôÞñéîçò öïñôßïõ, áíÜëïãá ìå ôéò áðáéôÞóåéò ôçò åãêáôÜóôáóçò, áðü 60ADC Ýùò 2500ADC. Ç óåéñÜ SME åßíáé ó÷åäéáóìÝíç ãéá óõíå÷Þ ëåéôïõñãßá óå áðáéôçôéêÜ ðåñéâÜëëïíôá êáé öÝñåé ðéóôïðïéÞóåéò IEC 478-1, IEC 62040-5-3, IEC 62040-1, IEC 62040-2, IEC 62040-4 & IEC 62040-5-3 áðïôåëþíôáò êïñõöáßá åðéëïãÞ ãéá ôçí ðëÞñç êÜëõøç ôùí ðéï áðáéôçôéêþí áíáãêþí êáé ôç ìÝãéóôç áîéïðéóôßá óÝñâéò. Ç PowerSales éäñýèçêå ôï 2001 ìå óêïðü ôçí åìðïñéêÞ êáé ôå÷íéêÞ õðïóôÞñéîç ÓõóôçìÜôùí ÁäéÜëåéðôçò Ðáñï÷Þò Éó÷ýïò (AC & DC UPS). Ç óõóóùñåõìÝíç åìðåéñßá 21 åôþí ìáò äßíåé ôç äõíáôüôçôá íá ðáñÝìâïõìå óå üëá ôá óôÜäéá ìåëÝôçò, åãêáôÜóôáóçò êáé óõíôÞñçóçò åíüò Áíïñèùôéêïý ÓõóôÞìáôïò - ÖïñôéóôÞ: l
¸ëåã÷ïò åãêáôÜóôáóçò êáé õðïëïãéóìüò ôùí öïñôßùí ðñéí ôçí åðéëïãÞ åíüò Áíïñèùôéêïý ÓõóôÞìáôïò (Site Survey).
l
ÅðéëïãÞ ôïõ êáôÜëëçëïõ ÓõóôÞìáôïò êáé Äéáóôáóéïðïßçóç ôùí ÄéáôÜîåùí Áðáéôïýìåíùí Óõóóùñåõôþí âÜóç ôùí äåäïìÝíùí ôå÷íéêþí ðñïäéáãñáöþí ôçò åêÜóôïôå åöáñìïãÞò.
l
ÄéåîáãùãÞ Äïêéìþí Ðéóôïðïßçóçò Áíïñèùôéêþí ÓõóôçìÜôùí (FATs) êáé Äïêéìþí Öüñôéóçò & Åêöüñôéóçò ÕöéóôáìÝíùí Óõóóùñåõôþí.
l
ÅãêáôáóôÜóåéò Áíïñèùôéêþí ÓõóôçìÜôùí, ÄïêéìÝò ÐáñÜäïóçò êáé Åêðáßäåõóç ôïõ ðñïóùðéêïý ôïõ ôåëéêïý ÷ñÞóôç óýìöùíá ìå ôéò ÅëëçíéêÝò, ÅõñùðáúêÝò áëëÜ êáé Äéåèíåßò ÐñïäéáãñáöÝò.
l
ÐñïëçðôéêÞ êáé åðáíïñèùôéêÞ óõíôÞñçóç ôùí Áíïñèùôéêþí ÄéáôÜîåùí óå áðëÞ êëÞóç ðåëÜôç Þ ìÝóù óõìâïëáßïõ óõíôÞñçóçò.
l
Ôå÷íéêÝò óõìâïõëÝò êáé ðñïôÜóåéò áíáâÜèìéóçò ôùí õöéóôáìÝíùí äéáôÜîåùí êáèþò êáé ìåëÝôç ãéá ìåëëïíôéêÞ áíáâÜèìéóç ëüãù áõîçìÝíùí åíåñãåéáêþí áðáéôÞóåùí.
Ç PowerSales åßíáé åðßóçìïò ìåôáðùëçôÞò êáé ðéóôïðïéçìÝíïò ðÜñï÷ïò ôå÷íéêÞò õðïóôÞñéîçò ôùí Áíïñèùôéêþí ÓõóôçìÜôùí ôçò Lever.
Ë. Áìáñïõóßïõ 48 Í. ÇñÜêëåéï Ô.Ê. 141 22 Ôçë.: 210 2841084 • Öáî: 210 2848676 • e-mail: info@powerservices.gr www.powersales.gr
po wer solu tions since 1973
Data Centers
ÓõóôÞìáôá CAN-BUS óôçí ðåñéâáëëïíôéêÞ äéá÷åßñéóç Data Centers
¢ñèñï ôïõ ÈÜíïõ Äáæåëßäç IT Product Manager Rittal Ltd e-mail: dazelidis.t@rittal.gr
Ô
á Data Centers óÞìåñá åíóùìáôþíïõí óõóôÞìáôá ðáñáêïëïýèçóçò ðïõ áðïóêïðïýí óôçí äéáóöÜëéóç ôçò åðïðôåßáò ôùí óõíèçêþí ðåñéâÜëëïíôïò óå üëåò ôéò åãêáôáóôÜóåéò áðü ôï ÷þñï ôïõ ãñáöåßïõ ôïõ äéá÷åéñéóôÞ. Ùóôüóï, êáèþò ïé åãêáôáóôÜóåéò áõîÜ-
íïíôáé óå êëßìáêá, áõîÜíåôáé êáé ç ðïëõðëïêüôçôÜ ôïõò áëëÜ êáé ç êáëùäßùóç ôùí åðéìÝñïõò êáôáóêåõáóôéêþí óôïé÷åßùí ãßíåôáé üëï êáé ðéï äýóêïëç - óõìðåñéëáìâáíïìÝíïõ ôïõ óõóôÞìáôïò ðáñáêïëïýèçóçò. Ôá óõóôÞìáôá ôýðïõ CAN-BUS (Controller Area
÷åßñéóçò üðùò åðßóçò êáé óå óõóôÞìáôá MOD-
Network) åðéëýïõí áõôü ôï ðñüâëçìá, åðéôñÝ-
BUS.
ðïíôáò ôéò óåéñéáêÝò äéáóõíäÝóåéò ìåôáîý ôùí äéáöüñùí áéóèçôÞñùí ðáñáêïëïýèçóçò êáé
ÅéóáãùãÞ
ìéáò êåíôñéêÞò ìïíÜäáò. Ôï CAN-BUS êáé ïé
¸íá Data Center óÞìåñá áíôéðñïóùðåýåé ôçí
äõíáôüôçôåò ãéá ìéá åöåäñéêÞ ðáñï÷Þ çëåêôñéêïý ñåýìáôïò ðáñÝ÷ïõí ôï áðáéôïýìåíï åðßðåäï áóöÜëåéáò, áîéïðéóôßáò êáé áíß÷íåõóçò âëáâþí.
12
êáñäéÜ ôùí åãêáôáóôÜóåùí ðëçñïöïñéêÞò óå ó÷åäüí üëåò ôéò ìéêñÝò êáé ìåãÜëåò åôáéñåßåò. Åêåß óõëëÝãïíôáé êáé áðïèçêåýïíôáé üëá ôá óçìáíôéêÜ äåäïìÝíá êáé áíáêôþíôáé ìå ðñüóâáóç
Óå áõôÜ ôá óõóôÞìáôá, ï ìéêñüò üãêïò ôçò óõ-
ðïõ ðáñÝ÷åôáé óå åîïõóéïäïôçìÝíïõò õðáëëÞ-
óêåõÞò åðéôñÝðåé åîïéêïíüìçóç ÷þñïõ êáé âåë-
ëïõò áíÜ ðÜóá óôéãìÞ. Ç ðñïóùñéíÞ äéáêïðÞ
ôéóôïðïßçóç ôçò ó÷Ýóçò ôéìÞò-áðüäïóçò. Ìå
ëåéôïõñãßáò ôïõ Data Center ìðïñåß íá Ý÷åé êá-
ôçí äéáëåéôïõñãéêüôçôá ôýðïõ OPC åßíáé áðï-
ôáóôñïöéêÝò óõíÝðåéåò êáé ìåôáîý Üëëùí åíÝ-
ôåëåóìáôéêÜ ó÷åäüí óå ïðïéïäÞðïôå åðïðôéêü
÷åé ðïëý ìåãÜëåò ðéèáíüôçôåò áðþëåéáò äåäï-
óýóôçìá åëÝã÷ïõ, óå õøçëüôåñá åðßðåäá äéá-
ìÝíùí. Ãéá áõôü ôïí ëüãï ðñÝðåé íá ðáñáêï-
COMMUNICATION SOLUTIONS
SPRING 2022
Data Centers
ëïõèåßôáé þóôå íá åîáóöáëßæåôáé ç Ýãêáéñç á-
åðåîåñãáóßáò. ÅðéðëÝïí, ôá óõóôÞìáôá ðñÝðåé
íôßäñáóç óå ïðïéáäÞðïôå ðñïâëÞìáôá êáé íá
íá õðüó÷ïíôáé ãñÞãïñç êáé áóöáëÞ åðéêïéíù-
áðïöåýãåôáé ç äéáêïðÞ ëåéôïõñãßáò óõóêåõþí
íßá äåäïìÝíùí ÷ùñßò äéáêïðÞ ëåéôïõñãßáò äéá-
óôï Data Center. Óôá üëï êáé ìåãáëýôåñá óýã-
èÝôïíôáò åðéðëÝïí åöåäñéêÞ ðáñï÷Þ çëåêôñé-
÷ñïíá Data Centers ç ÷ñÞóç ôå÷íéêþí âïçèç-
êïý ñåýìáôïò ãéá áîéüðéóôç ëåéôïõñãßá.
ìÜôùí Ý÷åé êáôáóôåß áðáñáßôçôç ãéá ôïõò äéá÷åéñéóôÝò ÉÔ. Åäþ êáé áñêåôÜ ÷ñüíéá ïé äéá÷åéñéóôÝò DC åìðéóôåýïíôáé ôÝôïéïõ ôýðïõ óõóôÞìáôá. Ïé áéóèçôÞñåò áõôþí ôùí óõóôçìÜôùí ðáñáêïëïõèïýí ôéò äéÜöïñåò «æùôéêÝò ëåéôïõñãßåò» ôïõ DC ìå ìåôñÞóåéò èåñìïêñáóßáò, õãñáóßáò, êáðíïý, äéáññïÞò ê.ëð.
Ðùò ëåéôïõñãåß ôï óýóôçìá BUS H êåíôñéêÞ ìïíÜäá ÷ñçóéìïðïéåß Ýíá CAN-BUS (äßêôõï ðåñéï÷Þò åëåãêôþí) ãéá ôçí åíóùìÜôùóç ôùí áéóèçôÞñùí ôïõ. Ôï CAN-BUS áíáðôý÷èçêå áðü ôçí åôáéñåßá Bosch ôï 1991, áñ÷éêÜ ó÷åäéÜóôçêå ãéá åöáñìïãÝò óôçí áõôïêé-
Áí ïðïéáäÞðïôå ðáñÜìåôñïò õðåñâáßíåé Ýíá
íçôïâéïìç÷áíßá, êáé óôçí óõíÝ÷åéá åîåëß÷èçêå
êáèïñéóìÝíï üñéï, ôá óõóôÞìáôá óôÝëíïõí Ýíá
íá åßíáé åõñÝùò ÷ñçóéìïðïéïýìåíï óôéò ôå÷íï-
ìÞíõìá êåéìÝíïõ ìå áíôßóôïé÷åò ðëçñïöïñßåò
ëïãßåò áõôïìáôïðïßçóçò. Ôï ðñùôüêïëëï CAN
óôïí åðéâëÝðïíôá, ï ïðïßïò ìðïñåß Ýôóé íá êé-
åßíáé ôõðïðïéçìÝíï óôï äéåèíÝò ðñüôõðï ISO
íÞóåé áíôßìåôñá ãéá íá áðïôñÝøåé ôçí áóôï÷ßá.
11898. Óôï ìïíôÝëï OSI, ôï "ìïíôÝëï áíáöï-
Óå Ýíá óõíå÷þò äéåõñõíüìåíï ðåñéâÜëëïí Data
ñÜò ãéá óõóôÞìáôá åðéêïéíùíßáò áíåîÜñôçôá
Center ç êáëùäßùóç ôùí áéóèçôÞñùí ãßíåôáé
áðü ôïí êáôáóêåõáóôÞ", áíôéðñïóùðåýåé ôá å-
ìéá ïëïÝíá êáé ìåãáëýôåñç ðñüêëçóç. Óå áðÜ-
ðßðåäá 1 êáé 2. Ìå Üëëá ëüãéá, ôï CAN äéá÷åéñß-
íôçóç óå áõôÞ ôçí åîÝëéîç, ç ÷ñÞóç óõóôçìÜ-
æåôáé ðñüóâáóç óôï êïéíü ìÝóï (BUS) êáé åîá-
ôùí ðïõ åíóùìáôþíïõí ôå÷íïëïãßá CAN-BUS
óöáëßæåé ôç óùóôÞ ìåôÜäïóç ôùí ìçíõìÜôùí.
åßíáé åðéâåâëçìÝíç êáèþò ìåéþíåé äñáóôéêÜ ôçí
Ïé ÷ñÞóôåò äéêôýïõ óå Ýíá CAN-BUS åßíáé äï-
ðïóüôçôá êáëùäßùí.
ìçìÝíïé óå ìéá ãñáììéêÞ ôïðïëïãßá. Ïé öõóéêÝò äéáóõíäÝóåéò ìåôáîý ÷ñçóôþí ãßíïíôáé åßôå ìå
Êáéíïôïìßåò Óôü÷ïò êáé áðáßôçóç
êáëþäéá Þ Üëëá ìÝóá, üðùò ïðôéêÝò ßíåò, åßôå ìðïñåß íá ÷ñçóéìïðïéçèåß ç áóýñìáôç ìåôÜäïóç. Óå üëï ôï äßêôõï, ïé ÷ñÞóôåò áíôéìåôùðßæï-
ÓÞìåñá ïé ðåñéóóüôåñïé êáôáóêåõáóôÝò åîï-
íôáé ùò ßóïé êáé åðéôñÝðåôáé íá ìåôáäßäïõí êáé
ðëéóìïý ðëçñïöïñéêÞò åßíáé ðñïóáíáôïëéóìÝ-
íá ëáìâÜíïõí åöüóïí ôï BUS åßíáé äùñåÜí. Ôá
íïé óôï ó÷åäéáóìü üëï êáé ðéï éó÷õñþí êáé ôáõ-
ðëáßóéá ìçíõìÜôùí äåí áðåõèýíïíôáé áðåõ-
ôü÷ñïíá ðéï óõìðáãþí óõóêåõþí, þóôå íá åßíáé
èåßáò óå ìåìïíùìÝíï êüìâï. ¸íá ìÞíõìá áðï-
åöéêôü íá ôïðïèåôïýíôáé ðåñéóóüôåñåò ìáæß.
óôÝëëåôáé áñ÷éêÜ óôï üëïõò ôïõò ÷ñÞóôåò. Óôç
¼óï ìéêñüôåñï åßíáé ëïéðüí ôï óýóôçìá ðáñá-
óõíÝ÷åéá, êÜèå ÷ñÞóôçò êáèïñßæåé ôç óõíÜöåéá
êïëïýèçóçò, ôüóï ðåñéóóüôåñïò ÷þñïò ðáñá-
ôïõ ìçíýìáôïò áíåîÜñôçôá êáé åßôå åðåîåñãÜ-
ìÝíåé óôï Rack ãéá äéáêïìéóôÝò êáé Üëëá åîáñ-
æåôáé åßôå áðïññßðôåé ôá ðåñéå÷üìåíÜ ôïõ. Ãéá
ôÞìáôá. ÅðåéäÞ óå áõôü ôï ðëáßóéï, ìåãáëýôå-
íá áðïöåõ÷èïýí óõãêñïýóåéò óôï BUS, ìéá ìÝ-
ñïò áñéèìüò åîáñôçìÜôùí óå Ýíá Rack óçìáß-
èïäïò ãíùóôÞ ùò CSMA/CD+CR (Áíß÷íåõóç
íåé ìåãáëýôåñï ðëÞèïò êáëùäßùí êáé êáëùäéþ-
ðñüóâáóçò/áðüññéøçò + áðüññéøç) åöáñìü-
óåùí ôá óõóôÞìáôá áðïóêïðïýí óôç ìåßùóç
æåôáé, üðùò öáßíåôáé óôï ÄéÜãñáììá 1.
ôçò ðïëõðëïêüôçôáò ôçò êáëùäßùóçò ìÝóù
ÅÜí Ýíáò áðü ôïõò ÷ñÞóôåò/óõóêåõÝò åðéèõìåß
ôçò óáöÝóôåñçò äñïìïëüãçóçò ôùí êáëùäßùí
íá ìåôáäþóåé ìÞíõìá, áêïýåé ðñþôá ãéá ôçí
ìåôáîý ôùí áéóèçôÞñùí êáé êåíôñéêÞò ìïíÜäáò
êõêëïöïñßá óôï êïéíü êáíÜëé. ÅÜí ôï êáíÜëé
SPRING 2022
COMMUNICATION SOLUTIONS
13
Data Centers
Ó÷åôéêÜ ìå ôï êïéíü êáíÜëé, Ýíá ëïãéêü "0" åßíáé
Node ready to transmit
ðÜíôá êõñßáñ÷ï, êáé Ýíá ëïãéêü "1" ðÜíôá õðï÷ùñåß. ÅÜí äýï ÷ñÞóôåò ìåôáäßäïõí äéáöïñåôéêÜ ìçíýìáôá ôáõôü÷ñïíá, ôï ðñþôï "1" ôïõ
Bus free?
no
ðñþôïõ ÷ñÞóôç èá áíôéêáôáóôáèåß áðü Ýíá "0" ôïõ äåýôåñïõ ÷ñÞóôç. Êáèþò êáé ïé äýï ÷ñÞóôåò ðáñáêïëïõèïýí åðßóçò ôï êáíÜëé êáôÜ ôç
yes Wait until bus free
äéÜñêåéá ôçò ìåôÜäïóçò, óôï ðñþôï "0" ï ðñþôïò ÷ñÞóôçò áíé÷íåýåé Ýíá "0" óôï êáíÜëé áíôß ãéá ôï äéêü ôïõ "1" êáé óôáìáôÜ ôç ìåôÜäïóÞ T=T-x
Wait specified time T
ôïõ. Óôï äåýôåñï "0" ï ÷ñÞóôçò äåí èá åíôïðßóåé óöÜëìá êáé èá óõíå÷ßóåé íá ìåôáäßäåé ôï õðüëïéðï ìÞíõìÜ ôïõ. ÊáôÜ ôç äéÜñêåéá áõôÞò ôçò ìåôÜäïóçò ï ðñþôïò ÷ñÞóôçò ðåñéìÝíåé íá åëåõèåñùèåß ôï êáíÜëé, Ýôóé þóôå íá ìðïñåß íá
Bus free?
no
ðñïóðáèÞóåé íá ìåôáäþóåé ìÞíõìá ãéá Üëëç ìéá öïñÜ. Ôï CAN-BUS åßíáé óå èÝóç íá ìåôáöÝñåé ñõè-
yes
ìïýò 1 Mbit/s óå áðüóôáóç 40 m. ÅÜí ôï êáëþäéï åßíáé ìáêñýôåñï, ï ñõèìüò áé÷ìÞò ìåéþíå-
Transmit message
ÄéÜãñáììá 1. ÌÝèïäïò åðéêïéíùíßáò
ôáé áíáëüãùò. Ï ðßíáêáò 1 äåß÷íåé ôïí åöéêôü ñõèìü ìåôÜäïóçò ãéá äéáöïñåôéêÜ ìÞêç êáëùäßùí.
äåí ÷ñçóéìïðïéåßôáé Þäç áðü Üëëï ÷ñÞóôç, áíáìÝíåé ãéá ðåñáéôÝñù êáèïñéóìÝíï ÷ñüíï êáé åðáëçèåýåé üôé ôï êáíÜëé åßíáé áêüìá åëåýèåñï ðñéí ôçí Ýíáñîç ôçò ìåôÜäïóçò. ÅÜí, åí ôù ìåôáîý, Ýíáò Üëëïò ÷ñÞóôçò Ý÷åé áñ÷ßóåé íá ìåôáäßäåé êáé Ýôóé Ý÷åé êáôáëÜâåé ôï êáíÜëé, ôüôå ç êáèõóôÝñçóç ðáñáôåßíåôáé Ýùò üôïõ ïëïêëçñùèåß áõôÞ ç ìåôÜäïóç. ÁõôÞ ç äéáäéêáóßá ïíïìÜæåôáé "back-off" êáé åðáíáëáìâÜíåôáé üóï óõ÷íÜ åßíáé áðáñáßôçôï ìÝ÷ñé ôï ìÝóï íá ðáñáìÝíåé åëåýèåñï ìåôÜ ôï ÷ñüíï áíáìïíÞò. Ï êáèïñéóìÝíïò ÷ñüíïò áíá-
14
Bit rate
Cable length
10 kbits/s 20 kbits/s 50 kbits/s 125 kbits/s 250 kbits/s 500 kbits/s 1 Mbits/s
6,7 km 3,3 km 1,3 km 530 m 270 m 130 m 40 m
Ðßíáêáò 1. Ñõèìüò ìåôÜäïóçò äåäïìÝíùí óå ó÷Ýóç ìå ôï ìÞêïò êáëùäßïõ
ìïíÞò ìåéþíåôáé ìåôÜ áðü êÜèå áðïôõ÷çìÝíç
ÈåùñçôéêÜ äåí õðÜñ÷åé üñéï óôïí áñéèìü ôùí
ðñïóðÜèåéá áýîçóçò ôçò ðéèáíüôçôáò ôïõ
÷ñçóôþí. Ôá óôïé÷åßá óýíäåóçò üìùò ôùí ìå-
êáíáëéïý ðïõ ðáñáìÝíåé åëåýèåñï. Êáèþò áõ-
ìïíùìÝíùí óõóôçìÜôùí ðåñéïñßæïõí ôïí ðéèá-
ôÞ ç ìÝèïäïò äåí åßíáé óå èÝóç íá áðïêëåßóåé
íü áñéèìü ÷ñçóôþí, êáé óõíÞèùò ðñïâëÝðïõí
åíôåëþò ôéò óõãêñïýóåéò, ôï ðñùôüêïëëï CAN-
32, 64 Þ Ýùò 128 ÷ñÞóôåò. Ìå ôïõò äéÜöïñïõò
BUS êáèïñßæåé ôçí áíôßäñáóç óå ðåñßðôùóç
ìç÷áíéóìïýò åëÝã÷ïõ ôïõ, ôï CAN-BUS äéáèÝ-
ðïõ äýï ÷ñÞóôåò áñ÷ßóïõí íá åêðÝìðïõí ôáõ-
ôåé ü÷é ìüíï õøçëü åðßðåäï áíï÷Þò óå óöÜëìá-
ôü÷ñïíá.
ôá áëëÜ êáé åêôåôáìÝíç áíß÷íåõóç âëáâþí. Áõ-
COMMUNICATION SOLUTIONS
SPRING 2022
Data Centers
Ó÷Þìá 1. ÔõðéêÞ óåéñéáêÞ óýíäåóç áéóèçôÞñùí
ôü êÜíåé ôï óýóôçìá éäéáßôåñá áîéüðéóôï êáé
ÓõìðÝñáóìá
êáôÜëëçëï ãéá ÷ñÞóç óå ðåñéâÜëëïíôá ðïõ
Áêüìç êáé óå çëåêôñïíéêÝò óõóêåõÝò üðùò SERVERS, NAS, firewalls ðïõ áíôéðñïóùðåýïõí ôçí ôåëåõôáßá ëÝîç ôçò ôå÷íïëïãßáò åíôïðßæïíôáé áóôï÷ßåò ðïõ ðñïêáëïýíôáé áðü ôï íåñü, ôç èåñìüôçôá, ê.ëð. Ãéá Ýíáí åôáéñéêü ÷ñÞóôç, ìéá äéáêïðÞ ëåéôïõñãßáò ôïõ Data Center óçìáßíåé õøçëÝò áðþëåéåò ìå åðáêüëïõèï ðñïâëÞìáôá êáé äáðÜíåò. ÅðåéäÞ áðïôåëåóìáôéêüò ôñüðïò áíôéìåôþðéóçò êáé åîÜëåéøçò äåí áíáìÝíåôáé óôï Üìåóï ìÝëëïí, ôá Data Centers ðñÝðåé íá ðáñáêïëïõèïýíôáé ìüíéìá áðü Ýîõðíá óõóôÞìáôá ðåñéâáëëïíôéêþí ìåôñÞóåùí üðùò èåñìïêñáóßáò, õãñáóßáò, êáðíïý, ðñüóâáóçò êëð, ìå óýóôçìá ìåôÜäïóçò CAN-BUS ìå ôçí åëÜ÷éóôç êáëùäßùóç êáé ôçí ìÝãéóôç áðüäïóç (ó÷Þìá 1).
õðüêåéíôáé óå ðáñåìâïëÝò. Ôï ðñùôüêïëëï CAN ïñßæåé ôçí ðñüóâáóç óôá áéóèçôÞñéá êáé ôï ìÞíõìá ìåôÜäïóçò, áëëÜ äåí ðåñéÝ÷åé ðñïäéáãñáöÝò ó÷åôéêÜ ìå åñìçíåßá ôùí ðñáãìáôéêþí äåäïìÝíùí ÷ñÞóôç. Ãéá ôï ëüãï áõôü ãßíåôáé ÷ñÞóç ôïõ ðñùôüêïëëïõ CAN-open. Óå áõôÞí ôçí ðåñßðôùóç, ôá äåäïìÝíá åê÷ùñïýíôáé óå äéáöïñåôéêïýò ôýðïõò êáé åßíáé äéáôåôáãìÝíá êáôÜ óåéñÜ óðïõäáéüôçôáò. Áõôü åðéôñÝðåé ôçí éåñÜñ÷çóç óõãêåêñéìÝíùí ìçíõìÜôùí. ¸ôóé, óçìáíôéêÜ äåäïìÝíá äéáâéâÜæïíôáé ðñþôá êáé Ýôóé äéáôßèåíôáé ôá÷ýôåñá óôçí ðëåõñÜ ôïõ äÝêôç ãéá åöáñìïãÝò êñßóéìåò óôïí ÷ñüíï.
Ëßãá ëüãéá ãéá ôïí áñèñïãñÜöï Ï ê. ÈÜíïò Äáæåëßäçò åñãÜæåôáé óôçí Rittal Ìïí.ÅÐÅ ùò product manager êáé sales manager ôá ôåëåõôáßá 14 ÷ñüíéá. E÷åé ôåëåéþóåé ôï ÔÅÉ åíåñãåéáêÞò ôå÷íéêÞò ÁèÞíáò êáé Ý÷åé ìåôáðôõ÷éáêü ôßôëï áðü ôï ðáíåðéóôÞìéï ôïõ Bradford óôá çëåêôñïíéêÜ éó÷ýïò êáé ôïí áõôïìáôéóìü. ¸÷åé åñãáóôåß óôï ðáñåëèüí óå åôáéñßåò ìåëåôþí áëëÜ êáé êáôáóêåõáóôéêÝò åôáéñßåò. Áó÷ïëåßôáé ìå ôïí ó÷åäéáóìü êáé õëïðïßçóç computer room áëëÜ êáé çëåêôñïìç÷áíïëïãéêþí Ýñãùí óôçí ÅëëÜäá êáé óôï åîùôåñéêü.
ÅÜí åðéèõìåßôå ôï COMMUNICATION SOLUTIONS íá äçìïóéåýóåé ðåñéóóüôåñá Üñèñá ãéá ôá Data Centers åðéêïéíùíÞóôå ìáæß ìáò óôï: info@comsol.gr
16
COMMUNICATION SOLUTIONS
SPRING 2022
GREECE 2022
110 0 tthh Data Center Infrastructures Networking and Services Conference Athens Domotel Kastri Hotel TBA Organized by
Communication Solutions The networking magazine
Data Centers
ÅöáñìïãÝò Ìðáôáñéþí Ëéèßïõ óôá Data Centers
¢ñèñï ôïõ Èåüäùñïõ ÈåïäùñÞ DCF Business Development Director Digital Power email: theodoros.theodoris@huawei.com
Ï
é ìðáôáñßåò ëéèßïõ-ìåôÜëëïõ êáé ïé ìðáôáñßåò éüíôùí ëéèßïõ êáôçãïñéïðïéïýíôáé ùò ìðáôáñßåò ëéèßïõ. Ùóôüóï, ï üñïò ìðáôáñßåò ëéèßïõ áíáöÝñåôáé ãåíéêÜ óå ìðáôáñßåò éüíôùí ëéèßïõ, ïé ïðïßåò äåí ðåñéÝ÷ïõí ìåôáëëéêü ëßèéï êáé õðïóôçñßæïõí êõêëéêÞ öüñ-
ôéóç êáé åêöüñôéóç. Ôï 1991, ç SONY ðáñïõóßáóå ôçí ðñþôç åìðï-
ôçò çëåêôñéêÞò åíÝñãåéáò, ôùí çëåêôñéêþí ï÷ç-
ñåýóéìç ìðáôáñßá éüíôùí ëéèßïõ. Ôï 2009, ç
ìÜôùí êáé ôùí data centers êáé êáèßóôáíôáé ùò
Huawei îåêßíçóå åõñåßáò êëßìáêáò ÷ñÞóç ìðá-
ç êõñßáñ÷ç ðçãÞ åíÝñãåéáò ôçò íÝáò ãåíéÜò.
ôáñéþí ëéèßïõ óå óôáèìïýò ôçëåðéêïéíùíéþí. Áðü ôï 2016, ç âéïìç÷áíßá ôùí çëåêôñéêþí ï÷çìÜôùí, ç ïðïßá ÷ñçóéìïðïéåß ìðáôáñßåò ëéèßïõ, áõîÜíåôáé åêèåôéêÜ. ÌÝ÷ñé óÞìåñá, ç éó÷ýò ôùí ìðáôáñéþí éó÷ýïò ðïõ Ý÷ïõí ðïõëçèåß áðü ôïõò êïñõöáßïõò êáôáóêåõáóôÝò ìðáôáñéþí ëéèßïõ óôïí êüóìï îåðåñíÜ ôéò 90 GWh. Êáèþò ç åíåñãåéáêÞ ðõêíüôçôá êáé ïé åðéäüóåéò áóöÜëåéáò ôùí ìðáôáñéþí éüíôùí ëéèßïõ åîáêïëïõèïýí íá âåëôéþíïíôáé åíþ ôï êüóôïò ìåéþíåôáé, ç æÞôçóç ãéá ìðáôáñßåò éüíôùí ëéèßïõ áõîÜíåôáé, óôïõò ôïìåßò ôùí åðéêïéíùíéþí, 18
COMMUNICATION SOLUTIONS
1. Ãéáôß áðáéôåßôáé ç ÷ñÞóç ìðáôáñßùí ëéèßïõ; Ïé ìðáôáñßåò ìüëõâäïõ-ïîÝïò êõñéÜñ÷çóáí óôç âéïìç÷áíßá ôùí åðéêïéíùíéþí ãéá äåêáåôßåò. ¼ìùò, ôá ìåéïíåêôÞìáôá, üðùò ç óýíôïìç äéÜñêåéá æùÞò, ôï ìåãÜëï ìÝãåèïò êáé âÜñïò êáèþò êáé ç ñýðáíóç ôïõ ðåñéâÜëëïíôïò êáôÜ ôç äéáäéêáóßá ðáñáãùãÞò, óõíåôÝëåóáí óôçí óõññßêíùóç ôçò áíÜðôõîçò ôïõò óå áñêåôÝò ÷þñåò. ÌÜëéóôá ìéá áðü ôéò ìåãáëýôåñåò åôáéñßåò ôçëåðéêïéíùíéþí óôïí êüóìï, ç China Tower, ðñï÷þñçóå Ýíá âÞìá ðáñáðÝñá, óôáìáôþíôáò SPRING 2022
Data Centers
íá äÝ÷åôáé ðñïóöïñÝò ãéá ìðáôáñßåò ìüëõâäïõ-ïîÝïò.
ìáôïò ëéèßïõ êáé ùò õëéêü áíüäïõ ãñáößôç, ðåñéÝ÷åé åðßóçò êáé îçñïýò çëåêôñïëýôåò.
Ïé ìðáôáñßåò ëéèßïõ äéáèÝôïõí ðïëëÜ ðëåïíåêôÞìáôá, üðùò õøçëÞ åíåñãåéáêÞ ðõêíüôçôá, ìéêñü áðïôýðùìá êáé ìåãÜëç äéÜñêåéá æùÞò. Êáèþò ôï ìåñßäéï áãïñÜò ôùí ìðáôáñéþí ìüëõâäïõ-ïîÝïò ìåéþíåôáé ñáãäáßá, ç ÷ñÞóç ìðáôáñéþí ëéèßïõ áõîÜíåôáé ðáãêïóìßùò. Ïé ìðáôáñßåò ëéèßïõ ÷ñçóéìïðïéïýíôáé óå üëá ó÷åäüí ôá 5G sites, åíþ ðáñÜëëçëá ôõã÷Üíïõí åõñåßáò ÷ñÞóçò óôá data centers ïñéóìÝíùí ìåãÜëùí ISPs. Ôï ìåñßäéï áãïñÜò ôùí ìðáôáñéþí ëéèßïõ ðñïâëÝðåôáé íá ðñïóåããßóåé Þ áêüìá êáé íá õðåñâåß åêåßíï ôùí ìðáôáñéþí ìüëõâäïõ-ïîÝïò óôá åðüìåíá 5 ÷ñüíéá. Åßíáé åõñÝùò áðïäåêôü üôé ïé ìðáôáñßåò ëéèßïõ èá êõñéáñ÷Þóïõí óôçí áãïñÜ óôï ìÝëëïí.
ÕëéêÜ êáèüäïõ: ÕðÜñ÷ïõí ðïëëÜ õëéêÜ êáèüäïõ. Ôá ðëÝïí óõíÞèç õëéêÜ åßíáé ôï óéäçñïöùóöïñéêü ëßèéï (LFP), ôï ìáããÜíéï êïâáëôéêü íéêÝëéï (NCM) Þ ôï íéêÝëéï êïâáëôéêü áëïõìßíéï (NCA).
1.1 ÂáóéêÝò Ýííïéåò
ÕëéêÜ áíüäïõ: Êõñßùò ÷ñçóéìïðïéåßôáé ï ãñáößôçò. ÐáñÜäåéãìá ìðáôáñßáò LFP: Áíôßäñáóç êáèüäïõ: Ôá éüíôá ëéèßïõ ðáñåìâÜëëïíôáé êáôÜ ôçí åêöüñôéóç êáé áðåìðëÝêïíôáé êáôÜ ôç äéÜñêåéá ôçò öüñôéóçò. Öüñôéóç: LiFePO4 à Li1-xFePO4 + xLi+ + xeÅêöüñôéóç: Li1-xFePO4 + xLi+ + xe- à LiFePO4 Aíôßäñáóç áíüäïõ: Ôá éüíôá ëéèßïõ áðåìðëÝêïíôáé êáôÜ ôçí åêöüñôéóç êáé ðáñåìâÜëëïíôáé êáôÜ ôç äéÜñêåéá ôçò öüñôéóçò. Öüñôéóç: xLi+ + xe- + 6 C à LixC6
ÂáóéêÝò ðáñÜìåôñïé ×ùñçôéêüôçôá ìðáôáñßáò (Ah): Ç óõíïëéêÞ ðïóüôçôá çëåêôñéêïý ðïõ áíôëåßôáé áðü ìéá ìðáôáñßá õðü ïñéóìÝíåò óõíèÞêåò (üðùò ï ñõèìüò åêöüñôéóçò, ç èåñìïêñáóßá, êáé ôÜóç óôï ôÝëïò ôçò åêöüñôéóçò EOD). Äåßêôçò öüñôéóçò/åêöüñôéóçò (C): Ï ñõèìüò öüñôéóçò/åêöüñôéóçò ðñïóäéïñßæåôáé áðü ôï ÷ñüíï ðïõ ÷ñåéÜæåôáé ãéá íá áðïöïñôßóôåé ðëÞñùò ç ìðáôáñßá êáé äßíåôáé ìå ôç ÷ùñçôéêüôçôá ôçò ìðáôáñßáò (óå Ah) äéáéñåìÝíç ìå ôïí áñéèìü ôùí ùñþí ðïõ ÷ñåéÜæïíôáé ãéá ôç öüñôéóç/ åêöüñôéóç ôçò ìðáôáñßáò. ÂáóéêÝò áñ÷Ýò ÓõíÞèùò, ìéá ìðáôáñßá éüíôùí ëéèßïõ ÷ñçóéìïðïéåß ùò õëéêü êáèüäïõ ìåôáëëéêÜ ïîåßäéá êñÜ-
Åêöüñôéóç: LixC6 à xLi+ + xe- + 6 C Ôáîéíüìçóç ìðáôáñéþí (óýìöùíá ìå ôï õëéêü êáèüäïõ) - LiCoO2 (LCO) - LiMnO2 (LMO) - LiFePO4 (LFP) - LiNiCoMnO2 (NCM). 1.2 ÌåãÜëç ÄéÜñêåéá ÆùÞò Ïé ìðáôáñßåò ëéèßïõ ðáñïõóéÜæïõí ìåãÜëç äéÜñêåéá æùÞò , ìåãÜëç äéÜñêåéá float charging, õøçëÞ áðüäïóç åêöüñôéóçò, ìéêñÞ áðþëåéá ðõêíüôçôáò óå ãñÞãïñç åêöüñôéóç, õøçëÞ åíåñãåéáêÞ ðõêíüôçôá êáé ìéêñü áðïôýðùìá. Å-
Cathode Material Structure
LFP ÔñéóäéÜóôáôç ìïñöÞ ïëéâßíçò Ðéï óôáèåñÞ äïìÞ SPRING 2022
LMO Êñýóôáëëïò êõâéêÞò äïìÞò ÓôáèåñÞ äïìÞ
LCO äéáâáèìéóìÝíç äéóäéÜóôáôç äïìÞ ÌåôáâëçôÞ äïìÞ
NCM äéáâáèìéóìÝíç äéóäéÜóôáôç äïìÞ ÌåôáâëçôÞ äïìÞ COMMUNICATION SOLUTIONS
19
Data Centers 25oC 0.5C/1C@70%EOL
25oC 0.1C discharge / charge @70%EOL 800
11200
9000 5850
6000
4000
3000
3000 0
25%
50%
75%
100%
Cycle life at different DOD
Number of Cycles
12000
700 600 500 400 300 200 100 0
10% 20% 30% 40%
50% 60%
DOD
DOD
Li-ion battery
Lead-acid battery
70% 80% 90% 100%
Åéêüíá 1: Êáìðýëåò äéÜñêåéáò æùÞò êýêëùí ìðáôáñéþí ëéèßïõ êáé ìïëýâäïõ-ïîÝïò
îïéêïíïìïýí ÷þñï óå óåíÜñéá ìå ðåñéïñéóìÝíï ÷þñï åãêáôÜóôáóçò. Êáèþò ôï êüóôïò ôçò ìðáôáñßáò ëéèßïõ ìåéþíåôáé, ïëïÝíá êáé ðåñéóóüôåñåò ìðáôáñßåò ëéèßïõ èá åãêáèßóôáíôáé óôá data centers. Ìðáôáñßá ëéèßïõ: l 100% âÜèïò åêöüñôéóçò (DOD) Ýùò ôïõò
3000 êýêëïõò. ÂáèéÜ åêöüñôéóç: ôïõëÜ÷éóôïí 3000 êýêëïé. l 50% DOD Ýùò ôïõò 6000 êýêëïõò. Ñç÷Þ åê-
öüñôóç: ôïõëÜ÷éóôïí 6000 êýêëïé. Ìðáôáñßá ìüëõâäïõ-ïîÝïò: l 100% DOD ðåñßðïõ óôïõò 150 êýêëïõò. Âá-
èéÜ åêöüñôéóç: áðáéôåßôáé óõ÷íÞ áíôéêáôÜóôáóç óå óåíÜñéá áóôáèïýò äéêôýïõ çëåêôñéêÞò åíÝñãåéáò.
1.3 ÄéÜñêåéá öüñôéóçò ÌáêñÜò æùÞò (Long Floating Charge Life) Ìðáôáñßá ëéèßïõ: l Float charging 70% End-Of-Life (EOL) óôïõò
25°C Ýùò êáé 15 ÷ñüíéá. Äåí õðÜñ÷åé áíÜãêç áíôéêáôÜóôáóçò åíôüò 15 åôþí, åÜí ôï äßêôõï çëåêôñéêÞò åíÝñãåéáò åßíáé åðáñêÝò. Ìðáôáñßá ìüëõâäïõ-ïîÝïò: l 70% EOL float charging óôïõò 25°C Ýùò êáé
7 ÷ñüíéá. Áðáéôåß áíôéêáôÜóôáóç êÜèå 3-7 ÷ñüíéá, áêüìç êáé áí ôï äßêôõï çëåêôñéêÞò åíÝñãåéáò åßíáé åðáñêÝò. Õøçëü êüóôïò ìðáôáñéþí êáé áðáéôçôÞ åñãáóßá ãéá óõíôÞñçóç.
l 50% DOD ðåñßðïõ óôïõò 600 êýêëïõò. Ñç÷Þ
1.4 ÕøçëÞ Áðïäïôéêüôçôá Åêöüñôéóçò, ×áìçëÞ Áðþëåéá Ðõêíüôçôáò óå ÃñÞãïñç Åêöüñôéóç
åêöüñôéóç: áðáéôåßôáé óõ÷íÞ áíôéêáôÜóôáóç óå óåíÜñéá áóôáèïýò äéêôýïõ çëåêôñéêÞò åíÝñãåéáò.
Ïé ìðáôáñßåò ëéèßïõ åßíáé êáôÜëëçëåò ãéá data centers üðïõ áðáéôåßôáé õøçëÞ åêöüñôéóç åíÝñãåéáò, óå óýíôïìï ÷ñïíéêü äéÜóôçìá.
o
o
Float Charging @25 C
Float Charging @25 C 1.3
100% Capacity Retention/%
Capacity Retention/%
90% 80% 70% 60% 50%
1.1 0.9 0.7 0.5
0
2
4
6
8
Service Life (Year)
Li-ion battery
10
12
14
16
0
2
4
6
8
10
Service Life (Year)
Lead-acid battery
Åéêüíá 2: Êáìðýëåò ÄéÜñêåéáò æùÞò óõíå÷ïýò öüñôéóçò ìðáôáñéþí ëéèßïõ & ìüëõâäïõ ïîÝïò 20
COMMUNICATION SOLUTIONS
SPRING 2022
Data Centers
Ìðáôáñßá ëéèßïõ:
2. Ãéáôß ÷ñåéÜæïíôáé ïé ìðáôáñßåò LFP;
l Âñá÷õðñüèåóìç åêöüñôéóç óå õøçëü ñõè-
Åðß ôïõ ðáñüíôïò, ïé êïéíüôõðåò ìðáôáñßåò ëéèßïõ óôç âéïìç÷áíßá ðåñéëáìâÜíïõí ôéò ìðáôáñßåò LCO, LMO, LFP êáé NCM. Ïé ìðáôáñßåò LCO ÷ñçóéìïðïéïýíôáé êõñßùò óôç âéïìç÷áíßá ôçò êéíçôÞò ôçëåöùíßáò, åíþ ïé ìðáôáñßåò LMO óôá çëåêôñéêÜ ðïäÞëáôá. Ïé ìðáôáñßåò LFP åõñÝùò óôá ëåùöïñåßá êáé ôéò åãêáôáóôÜóåéò áðïèÞêåõóçò åíÝñãåéáò, êáé ôÝëïò ïé NCM ìðáôáñßåò ÷ñçóéìïðïéïýíôáé åõñÝùò óôá ïéêéáêÜ ï÷Þìáôá, ôá ôáîß, êáé óå ìïíÜäåò áðïèÞêåõóçò åíÝñãåéáò. Ïé ìðáôáñßåò LFP êáé NCÌ óõíáíôþôáé óõíÞèùò óå data centers. Ïé ìðáôáñßåò LFP åßíáé ðéï áîéüðéóôåò, åíþ ïé ìðáôáñßåò NCM ðáñÝ÷ïõí õøçëüôåñç åíåñãåéáêÞ ðõêíüôçôá.
ìü: Åêöüñôéóç ðåñéóóüôåñçò åíÝñãåéáò. Êáèþò ï ñõèìüò åêöüñôéóçò áõîÜíåôáé, ç ÷ùñçôéêüôçôá åêöüñôéóçò ðáñáìÝíåé óôáèåñÞ êáé ìðïñåß íá õðåñâåß ôï 90%. Ìðáôáñßá ìüëõâäïõ-ïîÝïò: l Âñá÷õðñüèåóìç åêöüñôéóç óå õøçëü ñõè-
ìü: Åêöüñôéóç ëéãüôåñçò åíÝñãåéáò. Êáèþò ï ñõèìüò åêöüñôéóçò áõîÜíåôáé, ç ÷ùñçôéêüôçôá åêöüñôéóçò ìåéþíåôáé ñáãäáßá. Áðáéôïýíôáé ðåñéóóüôåñåò ìðáôáñßåò ãéá íá áíôéóôáèìéóôåß ôï ìåéïíÝêôçìá, ôï ïðïßï ìå ôç óåéñÜ ôïõ áõîÜíåé ôï êüóôïò ôçò åðÝíäõóçò. 1.5 ÕøçëÞ ÅíåñãåéáêÞ Ðõêíüôçôá, Ìéêñü Áðïôýðùìá
2.1 ÓôáèåñÞ ÄïìÞ
Ïé ìðáôáñßåò ëéèßïõ åßíáé ðåñßðïõ 70% åëáöñýôåñåò êáé ìéêñüôåñåò áðü ôéò ìðáôáñßåò ìüëõâäïõ-ïîÝïò. Ðñïôéìþíôáé óå óåíÜñéá ðåñéïñéóìÝíïõ ÷þñïõ.
Ïé ìðáôáñßåò LFP äéáèÝôïõí õøçëÞ èåñìéêÞ óôáèåñüôçôá êáé ÷áìçëÞ áðüäïóç èåñìüôçôáò. l Ïé ìðáôáñßåò LFP åßíáé óôáèåñÝò êáé ðáñÜ-
Ëüãïò âÜñïõò/åíåñãåéáêÞò ðõêíüôçôáò (Wh/kg): 3:1
ãïõí ëßãç èåñìüôçôá óå ðåñéâÜëëïíôá õøçëÞò èåñìïêñáóßáò. Ç ìÝãéóôç éó÷ýò áðüäïóçò èåñìüôçôáò åßíáé ðåñßðïõ 1 W.
l Ìðáôáñßá ëéèßïõ: 100-150, Ìðáôáñßá ìüëõâ-
l Ïé ìðáôáñßåò NCM åßíáé åðéññåðåßò óôçí áý-
äïõ-ïîÝïò: 30-50. Ëüãïò ðõêíüôçôáò üãêïõ/åíÝñãåéáò (Wh/L): 3:1 l Ìðáôáñßá ëéèßïõ: 200-300, Ìðáôáñßá ìüëõâ-
äïõ-ïîÝïò: 60-90.
îçóç ôùí åðéðÝäùí ïîõãüíïõ óå õøçëÝò èåñìïêñáóßåò Þ ðßåóç, ãåãïíüò ðïõ áõîÜíåé ôçí ðéèáíüôçôá åìöÜíéóçò öùôéÜò. Ç ìÝãéóôç éó÷ýò áðüäïóçò èåñìüôçôáò åßíáé ðåñßðïõ 80 W/min. Ç êáýóç (ìÝóá óå äåõôåñü0.1C
1C
2C
Li-ion
100%
100%
100%
VRLA
100%
60%
40%
120
80 VRLA (High-end)
60 40
VRLA (Loe-end)
20 0
0
2
4 C-rate
6
Released capacity %
Normalized Capacity (%)
Discharge rate
Li-ion
100
4C
95%
20%
Åéêüíá 3: Êáìðýëåò åêöüñôéóçò ìðáôáñéþí ëéèßïõ êáé ìüëõâäïõ-ïîÝïò óå äéáöïñåôéêïýò ñõèìïýò SPRING 2022
COMMUNICATION SOLUTIONS
21
Data Centers 200KW,Rated voltage 380V,Backup time 30 mins
Battery System Specifications Battery Type
Li-ion Battery
VRLA
Battery Layout
Space and footprint reduction
Building load-bearing capacity reduction 88%
Battery capacity reduction
68%
11,210
63%
9,166
800 2,925
1,400 Weight(kg)
300 Capacity(Ah)
Volume (l )
Åéêüíá 4: Óýãêñéóç áðïôõðþìáôïò êáé âÜñïõò ìåôáîý ìðáôáñéþí ëéèßïõ êáé ìüëõâäïõ-ïîÝïò ãéá ôçí ßäéá áðáßôçóç áõôïíïìßáò
ëåðôá) ìðïñåß åýêïëá íá ðñïêáëÝóåé Ýêñçîç, ç ïðïßá åßíáé äýóêïëï íá åëåã÷èåß.
ãéá íá åëåã÷èåß ç óôáèåñüôçôÜ ôïõ óå ðåñßðôùóç åóùôåñéêïý âñá÷õêõêëþìáôïò.
l Ç óõíïëéêÞ èåñìüôçôá ðïõ åêëýåôáé áðü
l Áðáñáßôçôç ç áóöÜëéóç óôçí ðëÞñùò
öïñôéóìÝíç ìðáôáñßá êáôÜ ôç äïêéìÞ.
ìðáôáñßåò LFP åßíáé ðïëý ÷áìçëüôåñç áðü åêåßíç ôùí ìðáôáñéþí NCM êáé LMO (ç
l ×ñçóéìïðïéåßôáé ìéá âåëüíá ÷Üëõâá äéáìÝ-
ðåñéï÷Þ ðïõ äçìéïõñãåßôáé áðü ôçí êáìðý-
ôñïõ 8 mm, õøçëÞò èåñìïêñáóéáêÞò áíï÷Þò, ãéá íá ôñõðçèåß ôï ãåùìåôñéêü êÝíôñï ôïõ êåëéïý êÜèåôá ùò ðñïò ôçí ðëÜêá ðïëéêüôçôáò ôïõ êåëéïý ìå ôá÷ýôçôá 25 mm/s, êñáôåßôáé ç âåëüíá óôï êåëß êáé ðáñáôÞñçóç ãéá 1 þñá.
ëç éó÷ýïò áðüäïóçò èåñìüôçôáò êáé ôïí ïñéæüíôéï Üîïíá, áíôéðñïóùðåýïõí ôç óõíïëéêÞ ðáñáãüìåíç èåñìüôçôá). 2.2 ÓôáèåñÞ Áðüäïóç
ÓõìðÝñáóìá äïêéìÞò:
l ÐáñáêÝíôçóç ôïõ êåëéïý ëéèßïõ ìå âåëüíá
l ÌåôÜ ôç äéÜôñçóç ìéáò ìðáôáñßáò LFP ìå
Heat Generation Rate of Positive-Solvent Reaction/W
ÊëáóóéêÞ ìÝèïäïò äïêéìÞò:
LiCoO2 Li1.1(Ni1/3Co1/3Mn1/3)0.9O2 LiMn2O4 LiFePO4 LiNi0.8Co0.15AI0.05O2
80
60 10
40
5
0 150
200
250
300
o
Temperature / C
20
0 50
100
150
200
250
300
350
400
450
Temperature /oC Source: FP. Peng, F. Jiang., Thermal safety of lithium-ion batteries with various cathode materials: A numerical study. International Journal of Heat and Mass Transfer. 103 (2016) 10081016
Åéêüíá 5: Èåñìüôçôá ðïõ ðáñÜãåôáé áðü ìðáôáñßåò ëéèßïõ óå äéáöïñåôéêÝò õøçëÝò èåñìïêñáóßåò 22
COMMUNICATION SOLUTIONS
SPRING 2022
Data Centers Ïé ìðáôáñßåò LFP äåí áðåëåõèåñþíïõí ïîõãüíï óå ðåñßðôùóç õðåñöüñôéóçò êáé õðåñåêöüñôéóçò. Ïé ìðáôáñßåò LFP ÷ñçóéìïðïéïýí ôñéóäéÜóôáôç äïìÞ ïëéâßíçò, ç ïðïßá åßíáé ðéï óôáèåñÞ êáé äåí áðåëåõèåñþíåé ôï ïîõãüíï Äåí áðåëåõèåñþíåôáé êáììßá åýöëåêôç ïõóßá Þ óôïé÷åßï ïîõãüíïõ, óôáèåñÞ äïìÞ
ÁñãÞ áðüäïóç èåñìüôçôáò, êáíÝíáò êßíäõíïò ðõñêáãéÜò Þ Ýêñçîçò
Ïé ìðáôáñßåò NCM áðåëåõèåñþíïõí ïîõãüíï óå ðåñßðôùóç õðåñöüñôéóçò êáé õðåñåêöüñôéóçò. Ïé ìðáôáñßåò NCM ÷ñçóéìïðïéïýí ìéá äéáâáèìéóìÝíç äéóäéÜóôáôç äïìÞ, ç ïðïßá åßíáé åýêïëï íá ðáñáìïñöùèåß êáé íá áðåëåõèåñþóåé ïîõãüíï ëüãù ôçò äéáöõãÞò èåñìüôçôáò Áðïóýíèåóç äïìÞò, áðåëåõèÝñùóç ïîõãüíïõ
Áðüôïìç áýîçóç ôçò èåñìïêñáóßáò, öùôéÜ êáé Ýêñçîç Source: Soroosh Sharifi-Asl, et al., Oxygen Release Degradation in Li-Ion Battery Cathode Materials: Mechanisms and Mitigating Approaches. Adv. Energy Mater. 2019, 1900551.
âåëüíá (åóùôåñéêü âñá÷õêýêëùìá), ç áíôß-
l ðïóüôçôá èåñìüôçôáò êáé ïîõãüíïõ óå óý-
äñáóç ôçò èåñìüôçôáò ìÝóá óôï êåëß åßíáé
íôïìï ÷ñïíéêü äéÜóôçìá. Ç ìðáôáñßá áíá-
åëÜ÷éóôç. Ç õøçëüôåñç èåñìïêñáóßá åðéöá-
öëÝãåôáé ìÝóá óå Ýíá äåõôåñüëåðôï, ç èåñ-
íåßáò ôïõ êåëéïý åßíáé ìüëéò 80°C, ôï êåëß
ìéêÞ äéáöõãÞ åìöáíßæåôáé ìÝóá óå 4 äåõôå-
äåí ðéÜíåé öùôéÜ ïýôå äéáññÝåé çëåêôñï-
ñüëåðôá, ç ìÝãéóôç èåñìïêñáóßá åðéöáíåßáò
ëýôåò. Ôï êÝëõöïò ôïõ ðáñáìÝíåé Üèéêôï.
öèÜíåé ôïõò 458°C êáé ôï êÝëõöïò ëéþíåé.
l ÌåôÜ ôç äéÜôñçóç ìéáò ìðáôáñßáò NCM ìå
3. Ðåñßëçøç Ìðáôáñéþí Ëéèßïõ ìå åöáñìïãÞ óôá Data Centers ÊáôÜ ôçí åðéëïãÞ ôçò óùóôÞò ìðáôáñßáò ãéá ôá
âåëüíá (åóùôåñéêü âñá÷õêýêëùìá), ôï êåëß áíôéäñÜ âßáéá åóùôåñéêÜ êáé ðáñÜãåé ìåãÜëç Óýíèåóç
Õøçëüôåñç Èåñìïêñáóßá
ÁðïôÝëåóìá ÄïêéìÞò ÄéÜôñçóçò
Ìðáôáñßá NCM
Li(NiCoMn)1/3O2
458oC
Êáýóç ìÝóá óå 1 sec, èåñìéêÞ äéáöõãÞ ìÝóá óå 4 sec, êáé ôÞîç ðåñéâëÞìáôïò
Ìðáôáñßá LFP
LiFePO4
80oC
Êáììßá äéáññïÞ çëåêôñïëõôþí, Üèéêôï ðåñßâëçìá, êáììßá êáýóç
10s
20s
30s
86oC, Catching Fire
458oC, Catching Fire Encloser Melted
411oC, Catching Fire Encloser Melted
72oC, No Fire
80oC, No Fire
NCM
LFP
46oC, No Fire
Ðßíáêáò 1: Óýãêñéóç äïêéìÞò áóöÜëåéáò ìåôáîý ìðáôáñéþí LFP êáé NCM (äïêéìÞ äéÜôñçóçò) SPRING 2022
COMMUNICATION SOLUTIONS
23
Data Centers VRLA
Ìðáôáñßá NCM
Ìðáôáñßá LFP
Áéôéïëïãßá Åîïéêïíüìçóç ÷þñïõ
Áðïôýðùìá
ÌåãÜëï
Ìéêñüôåñï
Ìéêñü
Êýêëïò æùÞò
Ìéêñüò
ÌåãÜëïò
ÌåãÜëïò
Êýêëïò öüñôéóçò
Ìéêñüò
ÌåãÜëïò
ÌåãÜëïò
Ñõèìüò åêöüñôéóçò
×áìçëüò
Õøçëüò
Õøçëüò
Áðüäïóç åêöüñôéóçò
×áìçëÞ
ÕøçëÞ
ÕøçëÞ
×çìéêÞ óôáèåñüôçôá
×áìçëÞ
ÕøçëÞ
Õøßóôç
Í/Á
ÖùôéÜ
×ùñßò ÖùôéÜ
ÄïêéìÞ ÐáñáêÝíôçóçò
Ðñüôáóç
Ëýóç ãéá åöáñìïãÝò ìå áóôáèÝò äßêôõï Ìðáôáñßåò ëéèßïõ
Äå áðáéôåßôáé áíôéêáôÜóôáóç åíôüò ôïõ êýêëïõ æùÞò Åêöüñôéóç õøçëÞò áðüäïóçò óå óýíôïìï ÷ñïíéêü äéÜóôçìá, éäáíéêü ãéá Data Center ÕøçëÞ åíÝñãåéá óå ãñÞãïñåò åêöïñôßóåéò
Ìðáôáñßåò ëéèßïõ ôå÷íïëïãßáò LFP
ÕøçëÞ áîéïðéóôßá ÕøçëÞ áîéïðéóôßá
Ðßíáêáò 2: ÐñïôÜóåéò ìðáôáñßáò ãéá data centers
óõóôÞìáôá áäéÜëåéðôçò ëåéôïõñãßáò, äåí ðñÝðåé íá ëáìâÜíïíôáé áðïöÜóåéò ìå âÜóç ìüíï ôï áñ÷éêü êüóôïò áëëÜ ôï óõíïëéêü êüóôïò éäéïêôçóßáò êáôÜ ôç äéÜñêåéá æùÞò ôçò ìðáôáñßáò, ôçí áóöáëÝóôåñç ëåéôïõñãßá êáé ôç ìáêñïæùßá ôçò ìðáôáñßáò. Ìéá ìðáôáñßá éüíôùí ëéèßïõ åßíáé ç êáëýôåñç åðéëïãÞ, ôüóï áðü Üðïøç ëåéôïõñãéêÞò áðüäïóçò üóï êáé áðü ôïí áõîçìÝíï óõíôåëåóôÞ áóöÜëåéáò ðïõ ðáñÝ÷åôáé. Óå êÜèå ðåñßðôùóç, äåí ðñÝðåé íá ëáìâÜíåôáé ç áðüöáóç ãñÞãïñá, ÷ùñßò íá óôáèìßæïíôáé ôá ðëåïíåêôÞìáôá êáé ôá ìåéïíåêôÞìáôá ôùí ÷çìéêþí ïõóéþí ôüóï ôçò ìðáôáñßáò NCÌ üóï êáé ôçò LFP. ÏñéóìÝíåò ìðáôáñßåò NCÌ ìðïñåß íá ðñïóöÝñïõí ôá÷ýôåñï ñõèìü öüñôéóçò (ðéèáíþò Ýùò 3C), áõôü üìùò äåí áðïôåëåß áðáñáßôçôá ìéá
áðáßôçóç. ÓðÜíéá åîÜëëïõ öïñôßæåôáé ìéá ìðáôáñßá áðü ôï 0 Ýùò 100 ôïéò åêáôü. Ïé ìðáôáñßåò LFP öïñôßæïíôáé ìå ÷áìçëüôåñï ñõèìü, áëëÜ ï ñõèìüò ìðïñåß íá áõîçèåß åýêïëá åÜí õðÜñ÷åé ç áðáßôçóç êáé ôá äåäïìÝíá äåß÷íïõí üôé ç ôå÷íïëïãßá LFP äéáèÝôåé ôç ìåãáëýôåñç äéÜñêåéá æùÞò óå üëåò ôéò óõíèÞêåò. Êáé ïé äýï ôýðïé éüíôùí ëéèßïõ õðåñôåñïýí áðü ôçí ðáëáéüôåñç ôå÷íïëïãßá ìïëýâäïõ-ïîÝïò (VRLA). Ùóôüóï, ôï ÷áìçëüôåñï óçìåßï áíÜöëåîçò ôïõ NCÌ áõîÜíåé ôçí ðéèáíüôçôá êéíäýíïõ ðõñêáãéÜò, éäéáßôåñá óå õøçëü ñõèìü öüñôéóçò áíáäåéêíýïíôáò ôçí LFP ôå÷íïëïãßá ìïíüäñïìç åðéëïãÞ üóïí áöïñÜ óôç ÷ñÞóç ôçò óå óýã÷ñïíá, ôåëåõôáßáò ôå÷íïëïãßáò, Data Centers.
Ëßãá ëüãéá ãéá ôïí áñèñïãñÜöï Ï ê. Èåüäùñïò ÈåïäùñÞò åñãÜæåôáé óôçí åôáéñåßá Huawei áðü ôï 2021 ùò Business Development Director, ðáñÝ÷ïíôáò áóöáëåßò, áðëÝò, Ýîõðíåò êáé áîéüðéóôåò ëýóåéò óå õðïäïìÝò Data Center óå ÂáëêÜíéá, ÅëëÜäá êáé Êýðñï. Áðü ôï 2007 Ý÷åé åñãáóôåß óõí ôïéò Üëëïéò ùò Product Marketing Manager êáé Key Account Manager óå çãåôéêÝò åôáéñåßåò ðïõ äñáóôçñéïðïéïýíôáé óôïõò ôïìåßò ÉÔ, Âéïìç÷áíßáò êáé ÅíÝñãåéáò, ìå óçìáíôéêü áñéèìü åðéôõ÷éþí óå Ýñãá õðïäïìþí. Åßíáé áðüöïéôïò Çëåêôñïëüãïò Ìç÷áíéêüò (B.Eng) ìå ìåôáðôõ÷éáêïýò ôßôëïõò óôç ÄéáóöÜëéóç Ðïéüôçôáò (M.Sc) êáé Äéïßêçóç Åðé÷åéñÞóåùí (ÌÂÁ), åéóçãçôÞò óå ðáíåðéóôçìéáêÝò çìåñßäåò, óõììåôÝ÷åé óå äéåèíÞ óõíÝäñéá, ôå÷íéêÝò åêðáéäåýóåéò êáé óåìéíÜñéá êáé åíçìåñþíåôáé óõíå÷þò ãéá ôéò ôåëåõôáßåò ôå÷íïëïãßåò êáé åîåëßîåéò ôïõ êëÜäïõ.
ÅÜí åðéèõìåßôå ôï COMMUNICATION SOLUTIONS íá äçìïóéåýóåé ðåñéóóüôåñá Üñèñá ãéá Data Centers åðéêïéíùíÞóôå ìáæß ìáò óôï: info@comsol.gr
24
COMMUNICATION SOLUTIONS
SPRING 2022
Ìåéþóôå ôïí ÷þñï óôï êÝíôñï äåäïìÝíùí êáôÜ 50% Ôï FlexCore™ Optical Distribution Frame åßíáé Ýíá åõÝëéêôï óýóôçìá êáëùäßùóçò åìðñüóèéáò ðñüóâáóçò ðïõ ðáñÝ÷åé ôçí áðáñáßôçôç ðñïóôáóßá ãéá êñßóéìåò óõíäÝóåéò. ×ñçóéìïðïéþíôáò êáéíïôüìï äéá÷åßñéóç êáëùäßùí êáé áðëÞ, äéáéóèçôéêÞ äñïìïëüãçóç êáëùäßùí, ôï FlexCore ODF áðëïðïéåß êáé ìåéþíåé ôïí ÷ñüíï ãéá ìåôáêéíÞóåéò, ðñïóèÞêåò êáé áëëáãÝò. Ìå êëáóóéêÝò ðüñôåò ìå êëåéäáñéÝò êáé ðñïáéñåôéêÝò êëåéäáñéÝò ãéá êÜèå ðåñßâëçìá, ç ëýóç FlexCore™ ODF åðéôñÝðåé ôçí áóöÜëåéá ðïëëáðëþí åðéðÝäùí ðïõ åßíáé óçìáíôéêÞ ãéá ôçí ðñüóâáóç ðïëëáðëþí ÷ñçóôþí. Ìå äõíáôüôçôá äéá÷åßñéóçò Ýùò êáé 3.168 éíþí áíÜ ðëáßóéï, ç ðñüôáóç FlexCore êáèéóôÜ åýêïëç ôç äçìéïõñãßá ðïëëáðëþí äéáìïñöþóåùí ÷ñçóéìïðïéþíôáò ìüíï ôñßá áñèñùôÜ äïìéêÜ óôïé÷åßá ðïõ áðïôåëïýíôáé áðü ðëáßóéï 600 mm êáé êÜèåôïõò ïäçãïýò êáëùäßùí 150 mm êáé 300 mm. ÁõôÞ ç åõåëéîßá åðéôñÝðåé ôçí ðñïóáñìïãÞ ôïõ ó÷åäéáóìïý êáé ôçí åðåêôáóéìüôçôá, åíþ âåëôéóôïðïéåß ôüóï ôç äéáèåóéìüôçôá ôùí ðñïúüíôùí üóï êáé ôçí ðõêíüôçôá ôïõ óõóôÞìáôïò. Óå óýãêñéóç ìå ôá ôõðéêÜ åñìÜñéá êÝíôñùí äåäïìÝíùí, ôï FlexCore™ ODF ìðïñåß íá ìåéþóåé ôïí áðáéôïýìåíï ÷þñï äáðÝäïõ óå Ýíá êÝíôñï äåäïìÝíùí êáôÜ 50%*. ÅðéðëÝïí, ìå ðëáúíÜ ðÜíåë êáé ðüñôåò ìå êëåéäáñéÝò, ôï óýóôçìá ìðïñåß íá åßíáé åíôåëþò êëåéóôü êáé áóöáëÝò. * ÐåñéëáìâÜíïíôáé 4 äéðëÜ êáñÝ (2 äéðëÜ êáñÝ óå äéÜôáîç «ðëÜôç - ðëÜôç»).
ÅîõðçñÝôçóç ðåëáôþí Ô 216 300 3333 F 216 300 3100 eshop www.kafkas.gr E customercare@kafkas.gr
infrastructure for a connected world
Ethernet
Ethernet Åíüò Æåýãïõò Ç ÍÝá Ðñáãìáôéêüôçôá óôçí Âéïìç÷áíßá
¢ñèñï ôïõ ÄçìÞôñç Öéëßððïõ Technical Director, I 2 QS PC. BICSI Country Chair, IEEE Senior Member, CSI Professional Engineer Member, ETHERNET ALLIANCE Consulting Member, ELOT Technical Committee TC93 Member, CENELEC TC209 & TC215 Delegate of Greek National Committee, CENELEC TC215 WG1, WG2 & WG3 Member. e-mail: dfilippou@i2qs.com
Ï
é âéïìç÷áíéêÝò åãêáôáóôÜóåéò êáé ïé áõôïêéíçôïâéïìç÷áíßåò ÷ñåéÜæïíôáé ìéá ïéêïíïìéêÜ áðïäïôéêÞ ëýóç óõíäåóéìüôçôáò ãéá óõóêåõÝò ÷áìçëÞò ôá÷ýôçôáò ìåôÜäïóçò äåäïìÝíùí, ôçí ïðïßá ðñïóöÝñïõí áðëÜ êáé ïéêïíïìéêÜ ôá ðñùôüêïëëá åðéêïéíùíßáò
10BASE-T1S êáé 10BASE-T1L ôçò IEEE.
26
Ï êüóìïò åßíáé ãåìÜôïò áðü ðñùôüêïëëá å-
÷áìçëïý êüóôïõò ëýóç åðéêïéíùíßáò äåäïìÝ-
ðéêïéíùíßáò äåäïìÝíùí, ìå ôá ðåñéóóüôåñá á-
íùí ðïõ íá åîõðçñåôåß üëåò ôéò óõóêåõÝò. Ç
ðü áõôÜ íá Ý÷ïõí ó÷åäéáóôåß ãéá íá ðáñÝ÷ïõí
ëýóç åìöáíßóôçêå óôá ôÝëç ôïõ 2019 ìå ôç
ôïõò õøçëüôåñïõò äõíáôïýò ñõèìïýò ìåôÜ-
ìïñöÞ ôïõ ðñïôýðïõ 802.3cg ôçò IEEE. Ç ëýóç
äïóçò. ¼ìùò óôçí âéïìç÷áíßá, ç óõíôñéðôéêÞ
áõôÞ Ý÷åé ôåñÜóôéåò äõíáôüôçôåò åðåéäÞ åéóÜ-
ðëåéïøçößá ôùí óõóêåõþí, üðùò ïé äéáêüðôåò
ãåé ôçí ÷áìçëïý êüóôïõò êáëùäßùóç Ethernet
êáé ïé åíåñãïðïéçôÝò (Actuator), åßíáé áðëÝò,
åíüò æåýãïõò óôçí Üêñç ôïõ äéêôýïõ.
äåí ðáñÜãïõí ôåñÜóôéåò ðïóüôçôåò äåäïìÝíùí
Ç ðñùôïâïõëßá ãéá ôçí áíÜðôõîç ôïõ ðñïôý-
êáé åðïìÝíùò äåí áðáéôïýí åðéêïéíùíßá õøçëÞò
ðïõ ðñïÞëèå áðü ìéá ïìÜäá åñãáóßáò ôçò
ôá÷ýôçôáò. ÕðÜñ÷ïõí äéóåêáôïììýñéá áðü áõ-
IEEE ðïõ ìåëåôïýóå ôçí áíÜðôõîç ìéáò ôå÷íï-
ôÝò ôéò óõóêåõÝò ðáãêïóìßùò êáé ï áñéèìüò
ëïãßáò ìåôÜäïóçò ÷áìçëÞò ôá÷ýôçôáò ðïõ èá
ôïõò áõîÜíåôáé ìå ãåùìåôñéêÞ ðñüïäï.
ìðïñïýóå íá êáëýøåé ðïëý ìåãÜëåò áðïóôÜ-
Áõôü ðïõ ÷ñåéáæüôáí åäþ êáé áñêåôü êáéñü óôç
óåéò êáé íá ðáñÝ÷åé ñõèìü äåäïìÝíùí ôçò ôÜ-
âéïìç÷áíßá, óôçí áõôïêéíçôïâéïìç÷áíßá êáèþò
îçò ôùí 10Mb/s ìÝóù ìéáò ãñáììÞò ìåôáöï-
êáé óôéò Üëëåò áãïñÝò Þôáí ìéá åíéáßá, áðëÞ,
ñÜò Ethernet åíüò ìüíï éóïóôáèìéóìÝíïõ æåý-
COMMUNICATION SOLUTIONS
SPRING 2022
Ethernet
ãïõò. ÅðéðëÝïí, õðÞñ÷å ç åðéèõìßá äõíáôüôç-
óôçí ïéêïãÝíåéá ðïõ åßíáé ãíùóôÞ ùò Ethernet
ôáò õðïóôÞñéîçò ðïëëáðëþí ôåñìáôéêþí
Åíüò-Æåýãïõò (Single-Pair Ethernet - SPE). Ôï
(Multidrop) óå ìéêñüôåñåò áðïóôÜóåéò. Áí êáé ç
ìÝóï ìåôÜäïóçò áðïôåëåßôáé áðü Ýíá ìüíï óõ-
ôá÷ýôçôá ôùí 10Mb/s äåí áêïýãåôáé åíôõðù-
íåóôñáììÝíï æåýãïò áãùãþí Þ/êáé Üëëåò äéá-
óéáêÞ, åßíáé õðåñáñêåôÞ ãéá ôïí Ýëåã÷ï åíüò
ìïñöþóåéò æåõãþí áãùãþí, êáèþò êáé áðü ðá-
äéáêüðôç, åíüò ñåëÝ, åíüò åíåñãïðïéçôÞ Þ å-
ñÜëëçëåò ãñáììÝò ôõðùìÝíåò óå ìéá ðëáêÝôá
íüò âñá÷ßïíá ñïìðüô êáé Üëëùí ðïëëþí óõ-
ôõðùìÝíïõ êõêëþìáôïò (Printed Circuit Board -
óêåõþí, êáèþò ðñéí áðü ôñßá ÷ñüíéá, ôï âéïìç-
PCB) Þ óå Ýíá ïðéóèåðßðåäï (Backplane) åíüò
÷áíéêü Ethernet äåí åß÷å êáìßá ëýóç ðïõ íá
åîõðçñåôçôÞ (Server). ¼ëá ðëÝïí åßíáé åõêïëü-
ðáñÝ÷åé üëåò áõôÝò ôéò äõíáôüôçôåò ìå Ýíáí
ôåñá óôçí åãêáôÜóôáóç, åëáöñýôåñá, ðéï åõÝ-
óõíåêôéêü ôñüðï.
ëéêôá êáé ëéãüôåñï äáðáíçñÜ áðü êÜèå Üëëç å-
Ïé ìç÷áíéêïß ôçò áõôïêéíçôïâéïìç÷áíßáò ðïõ
íáëëáêôéêÞ ëýóç, üðùò ðåñéãñÜöåôáé óôïí Ðß-
óõììåôåß÷áí óôçí ïìÜäá åñãáóßáò ôçò IEEE
íáêá 1.
æÞôçóáí ìéá ëýóç ìéêñüôåñçò åìâÝëåéáò ìå ôéò ßäéåò âáóéêÝò äõíáôüôçôåò ðáñÜëëçëá ìå ôç
ÂáóéêÝò Áñ÷Ýò
äõíáôüôçôá õðïóôÞñéîçò ðïëëáðëþí ôåñìáôé-
Óôï ðñüôõðï 802.3cg ôçò IEEE ïñßæïíôáé ôá ëï-
êþí, üðïõ êÜèå êüìâïò èá óõíäÝåôáé ìå ìéá ìü-
ãéêÜ, çëåêôñéêÜ êáé ìç÷áíéêÜ ÷áñáêôçñéóôéêÜ
íï ãñáììÞ ìåôáöïñÜò. Ç ëýóç áõôÞ èá Ýðñåðå
ôïõ õðïåðßðåäïõ Ôáêôïðïßçóçò (Reconciliation
íá åîáëåßöåé ôçí áíÜãêç ÷ñÞóçò åíüò ìåôá-
Sublayer - RS), êáèþò êáé ç ÄéåðáöÞ ÁíåîÜñôç-
ãùãïý, áðáéôþíôáò ëéãüôåñåò ãñáììÝò, èýñåò
ôç ÌÝóïõ (Media Independent Interface - MII)
ìåôáãùãïý êáé ðïìðïäÝêôåò (Transceiver). Ç
ìåôáîý ôùí CSMA/CD åëåãêôþí ðñüóâáóçò
éäÝá Þôáí íá ÷ñçóéìïðïéçèåß ôï Ethernet ãéá ôá
ìÝóïõ êáé ôùí äéáöüñùí ìÝóùí ìåôÜäïóçò ôïõ
ðÜíôá, áðü ôéò ÷áìçëüôåñåò Ýùò ôéò õøçëüôå-
Öõóéêïý åðéðÝäïõ (PHYsical layer - PHY). Óôï
ñåò ôá÷ýôçôåò.
Ó÷Þìá 1 áðåéêïíßæåôáé ç ó÷Ýóç ôïõ õðïåðéðÝ-
ÔåëéêÜ, üëï ôï åã÷åßñçìá óôÝöèçêå ìå åðéôõ-
äïõ Ôáêôïðïßçóçò (RS) êáé ôçò ÄéåðáöÞò Áíå-
÷ßá, ìå áðïôÝëåóìá ôçí áíÜðôõîç ôïõ Ethernet
îÜñôçôçò ÌÝóïõ (MII), óýìöùíá ìå ôï ÌïíôÝëï
10BASE-T1S ãéá áðïóôÜóåéò ôïõëÜ÷éóôïí Ýùò
Äéáóýíäåóçò Áíïéêôþí ÓõóôçìÜôùí (Open Sy-
25m êáé ôïõ 10BASE-T1L ãéá áðïóôÜóåéò ìÝ÷ñé
stem Interconnection - OSI) ôùí ISO/ IEC, ãíù-
êáé 1km. Ôá äýï áõôÜ ðñùôüêïëëá ìáæß ìå ôï
óôü ùò ìïíôÝëï áíáöïñÜò OSI.
100BASE-T1 êáé ôï 1000BASE-T1 åíôÜ÷èçêáí
Ï óêïðüò ôçò äéåðáöÞò ÌÉÉ åßíáé íá ðáñÝ÷åé ìéá
ÌÞêïò ÃñáììÞò ÌåôáöïñÜò (m)
Ôá÷ýôçôá ÌåôÜäïóçò ÄåäïìÝíùí
Äõíáôüôçôá ÌåôÜäïóçò
Áãùãïß
10/100/1000/10GBASE-T
100
10Mb/s Ýùò 10Gb/s
Áìößäñïìç (Full-Duplex)
4 Ýùò 8
10BASE-T1S
>25
10Mb/s
Çìéáìößäñïìç (Half-Duplex) Þ Áìößäñïìç
2
10BASE-T1L CAN FlexRay
1000 500 40 (@ 1Mb/s)
10Mb/s 1Mb/s Ýùò 10Mb/s
Áìößäñïìç Çìéáìößäñïìç Áìößäñïìç
2 2 2
Ðñüôõðï
10Mb/s
Ðßíáêáò 1. Óýãêñéóç ðñïôýðùí óõíäåóéìüôçôáò SPRING 2022
COMMUNICATION SOLUTIONS
27
Ethernet Åðßðåäá LAN CSMA/CD
Åðßðåäá ÌïíôÝëïõ ÁíáöïñÜò OSI
Õøçëüôåñá Åðßðåäá
ÅöáñìïãÞò
Åðßðåäï LLC (ÅëÝã÷ïõ ËïãéêÞò Äéáóýíäåóçò) Þ Üëëï MAC õðïåðßðåäï
Ðáñïõóßáóçò
Åðßðåäï ÅëÝã÷ïõ MAC (Ðñïáéñåôéêü)
Óõíüäïõ
Åðßðåäï ÅëÝã÷ïõ ÌÝóïõ Ðñüóâáóçò (MAC) Åðßðåäï Ôáêôïðïßçóçò
ÌåôáöïñÜò
MII
MII/GMII
Äéêôýïõ Äéáóýíäåóçò ÄåäïìÝíùí Öõóéêü
Åðßðåäï Ôáêôïðïßçóçò
PLS
PCS
PMA
PMA PMD
AUI MAU
PHY
MDI
MDI ÌÝóï ÌåôÜäïóçò
ÌÝóï ÌåôÜäïóçò
10 Mb/s
10BASE-T1L, 10BASE-T1S, 100 Mb/s, 1 Gb/s
AUI = ÄéåðáöÞ ÌïíÜäáò ÐñïóÜñôçóçò GMII = Gigabit ÄéåðáöÞ ÁíåîÜñôçôç ÌÝóïõ MAU = ÌïíÜäá ÐñïóÜñôçóçò ÌÝóïõ MDI = ÄéåðáöÞ Åîáñôþìåíç ÌÝóïõ MII = ÄéåðáöÞ ÁíåîÜñôçôç ÌÝóïõ
PCS = Õðïåðßðåäï ÖõóéêÞò Êùäéêïðïßçóçò PHY = ÌïíÜäá Öõóéêïý ÅðéðÝäïõ PLS = Óçìáôïäïóßá Öõóéêïý ÅðéðÝäïõ PMA = ÌïíÜäá ÐñïóÜñôçóçò Öõóéêïý ÅðéðÝäïõ PMD = Öõóéêü Åðßðåäï Åîáñôþìåíï ÌÝóïõ
Ó÷Þìá 1. Ó÷Ýóç ôçò MII ìå ôï ISO/IECOSI ìïíôÝëï áíáöïñÜò êáé ôï ìïíôÝëï ôïðéêïý äéêôýïõ (LAN) IEEE 802.3 CSMA/CD
28
áðëÞ, öèçíÞ êáé åýêïëç óôçí õëïðïßçóç äé-
ðïõ áðáéôïýí íôåôåñìéíéóôéêÝò åðéäüóåéò, üðùò
áóýíäåóç ìåôáîý ôùí õðïåðéðÝäùí ÅëÝã÷ïõ
ïé áõôïìáôéóìïß ôùí áõôïêéíÞôùí, ïé âéïìç÷áíé-
Ðñüóâáóçò ÌÝóïõ (Media Access Control -
êïß êáé ïé êôéñéáêïß áõôïìáôéóìïß, ôï ðáêÝôï ìå-
MAC) êáé ôùí äéÜöïñùí ôýðùí Öõóéêïý ÅðéðÝ-
ôÜäïóçò ôçò ïðïßáò áðåéêïíßæåôáé óôï Ó÷Þìá 2.
äïõ (PHY) ãéá ôçí ìåôáöïñÜ äåäïìÝíùí óôá
Ç PLCA áñ÷éôåêôïíéêÞ Ý÷åé ó÷åäéáóôåß ãéá äß-
10Mb/s êáé óôá 100Mb/s, êáèþò êáé ìåôáîý ôçò
êôõá çìéáìößäñïìçò Þ áìößäñïìçò ìåôÜäïóçò,
Äéá÷åßñéóçò Óôáèìþí - Ôåñìáôéêþí (Station-
ðïëëáðëþí ôåñìáôéêþí, üðùò ôï 10BASE-T1S
Management - STA) êáé ôùí äéÜöïñùí ôýðùí
êáé åîáëåßöåé ôá ðñïâëÞìáôá ôçò ðïëëáðëÞò
Öõóéêïý ÅðéðÝäïõ (PHY).
ðñüóâáóçò ìå åðáßóèçóç öÝñïõóáò êáé áíß-
Åêôüò áðü ôéò ìÝãéóôåò áðïóôÜóåéò ìåôÜäïóçò,
÷íåõóç óýãêñïõóçò (Carrier Sense Multiple
õðÜñ÷ïõí äýï êýñéåò äéáöïñÝò ìåôáîý ôïõ
Access with Collision Detection - CSMA/CD) óå
10BASE-T1S êáé ôïõ 10BASE-T1L. Ðñþôïí, ìü-
ìéêôÜ ôìÞìáôá ðïëëáðëþí ôåñìáôéêþí.
íï ôï 10BASE-T1S ðñïóöÝñåé äõíáôüôçôá õðï-
Ç CSMA/CD ôå÷íéêÞ ìðïñåß íá åìöáíßæåé ôõ-
óôÞñéîçò ðïëëáðëþí óôáèìþí, êáèþò êáé äõ-
÷áßåò êáèõóôåñÞóåéò ðïõ ðñïêáëïýíôáé áðü ôéò
íáôüôçôá äéóçìåéáêÞò (point-to-point) óýíäå-
óõãêñïýóåéò ôùí äåäïìÝíùí. Ç PLCA äéáèÝôåé
óçò. Äåýôåñïí, ìüíï ôï 10BASE-T1S ÷ñçóéìï-
åããõçìÝíç ìÝãéóôç êáèõóôÝñçóç, êáèþò êáé
ðïéåß ôçí Öõóéêïý ÅðéðÝäïõ ÁðïöõãÞ Óýãêñïõ-
Üëëá ÷áñáêôçñéóôéêÜ ðïõ îåðåñíïýí áõôïýò
óçò (Physical Layer Collision Avoidance -
ôïõò ðåñéïñéóìïýò. Ìå ôçí ÷ñÞóç ôçò PLCA, ï
PLCA), ç ïðïßá èåùñåßôáé ôï âáóéêüôåñï óõ-
êýêëïò ìåôÜäïóçò îåêéíÜ ìå Ýíá bit óõã÷ñïíé-
óôáôéêü óå åöáñìïãÝò ðñáãìáôéêïý ÷ñüíïõ
óìïý, ãíùóôü ùò öÜñïò (Beacon) ðïõ áðï-
COMMUNICATION SOLUTIONS
SPRING 2022
Ethernet 10Mb/s ðïëõôåñìáôéêü ôìÞìá ìå Í êüìâïõò
0
1
2
...
N
Êýêëïò ÌåôÜäïóçò
0
0
ý ìï ïý íéó óéê 0 ï õ ñ ) ÷ n Ö Y) Óõã aco Ýíá õ (PH ì Bit (Be ï ï Äåä éðÝä Åð
1
ý Þò éêï Óéã õó ) 1 Bit Ö Y Ýíá (PH ïì äïõ ä å Ä éðÝ Åð
N
...
0
0
t
Þò Óéã Bit
ý ïý éêï óì é õó ) Í í Ö á HY ÷ñï n) ìÝí ïõ (P Óõã eaco ï t i ä ä B (B Äå éðÝ Åð
Ó÷Þìá 2. Áñ÷éôåêôïíéêÞ Öõóéêïý ÅðéðÝäïõ ÁðïöõãÞò Óýãêñïõóçò (PLCA)
óôÝëëåôáé áðü Ýíáí êüìâï óõíôïíéóôÞ (Êüìâïò
óôïí êüóìï ôçò Åðé÷åéñçóéáêÞò Ôå÷íïëïãßáò
0), ôïí ïðïßï ÷ñçóéìïðïéïýí ïé õðüëïéðïé êüì-
(Operational Technology - OT), åíþ åßíáé åõñÝ-
âïé ôïõ äéêôýïõ ãéá íá óõã÷ñïíéóôïýí.
ùò ãíùóôü êáé õðïóôçñßæåôáé áðü åêáôïíôÜäåò
ÌåôÜ ôçí áðïóôïëÞ ôïõ bit óõã÷ñïíéóìïý
åôáéñåßåò. Ôï êüóôïò ôïõ Ethernet åßíáé ó÷åôéêÜ
(Beacon), ç äõíáôüôçôá ìåôÜäïóçò ðåñíÜ óôïí
÷áìçëü êáé âáßíåé ìåéïýìåíï, åíþ Ý÷åé äéáôçñÞ-
Êüìâï 1. ÅÜí ï Êüìâïò 1 äåí Ý÷åé äåäïìÝíá ãéá
óåé ôç âáóéêÞ äïìÞ ôïõ óå êÜèå íÝá ôå÷íïëï-
áðïóôïëÞ, ç äõíáôüôçôá ìåôÜäïóçò ðåñíÜ
ãéêÞ ðñïóÝããéóç áðü ôçí áñ÷Þ ôçò äçìéïõñãßáò
óôïí Êüìâï 2 êáé ïýôù êáèåîÞò, ìå ôç äéáäéêá-
ôïõ. Áõôü óçìáßíåé üôé üôáí óå Ýíá óýóôçìá
óßá íá óõíå÷ßæåôáé ìÝ÷ñé íá äïèåß óå êÜèå êüì-
÷ñçóéìïðïéåßôáé ôï Ethernet ùò êýñéï ðñùôü-
âï ôïõ äéêôýïõ ôïõëÜ÷éóôïí ìßá åõêáéñßá ìåôÜ-
êïëëï åðéêïéíùíßáò, äåí õðÜñ÷åé êáìßá áíÜãêç
äïóçò. Óôç óõíÝ÷åéá îåêéíÜ Ýíáò íÝïò êýêëïò
ìåôáôñïðÞò ðñùôïêüëëïõ êáé åðïìÝíùò äåí
áðü ôïí êüìâï óõíôïíéóôÞ (Êüìâïò 0), ï ïðïß-
áðáéôåßôáé ç ÷ñÞóç ðýëçò (Gateway).
ïò óôÝëíåé åê íÝïõ Ýíá Üëëï bit óõã÷ñïíéóìïý.
ÊÜèå åßäïò óõóêåõÞò ìðïñåß íá õðïóôçñé÷èåß
Ãéá íá áðïôñáðåß ç ïðïéáäÞðïôå ðáñåìðüäéóç
÷ùñßò êáìßá ìåôáôñïðÞ, áðü Ýíá áðëü äéáêü-
ôçò ìåôÜäïóçò äåäïìÝíùí óôïí äßáõëï åðéêïé-
ðôç ÷áìçëÞò ôá÷ýôçôáò ìåôÜäïóçò äåäïìÝíùí
íùíßáò (Bus) áðü êÜðïéï êüìâï, ìéá óõíÜñôçóç
Ýùò ôïõò áéóèçôÞñåò õøçëÞò ôá÷ýôçôáò äåäï-
åëÝã÷ïõ õðÝñâáóçò (Jabber) äéáêüðôåé ôç ìå-
ìÝíùí, üðùò ïé êÜìåñåò ðïõ ðáñÜãïõí ôåñÜ-
ôÜäïóç ôïõ êüìâïõ ðïõ äýíáôáé íá ðáñåìðï-
óôéåò ðïóüôçôåò äåäïìÝíùí êáé áðáéôïýí ôá÷ý-
äßóåé ôçí ìåôÜäïóç äåäïìÝíùí, åÜí áõôüò õ-
ôçôåò ôçò ôÜîçò ôïõ åíüò gigabit áíÜ äåõôåñü-
ðåñâåß ôïí åê÷ùñçìÝíï ÷ñüíï ôïõ, äßíïíôáò
ëåðôï. ¼ëá ôá äåäïìÝíá ðïõ ðáñÜãïíôáé ìðï-
ôçí äõíáôüôçôá óôïí åðüìåíï êüìâï íá åêðÝì-
ñïýí íá áðïóôáëïýí ìÝóù åíüò ìåôáãùãïý
øåé. Ôï áðïôÝëåóìá åßíáé üôé äåí õðÜñ÷åé êáìßá
Ethernet óôï õðïëïãéóôéêü íÝöïò (Cloud) ìå
åðßäñáóç óôç äéåêðåñáéùôéêüôçôá (Throug-
ôïí õøçëüôåñï äõíáôü ñõèìü ìåôÜäïóçò ãéá
hput) ôùí äåäïìÝíùí êáé êáìßá óýãêñïõóç
åðåîåñãáóßá êáé áíÜëõóç, üðùò áðåéêïíßæåôáé
ôïõò óôï äßáõëï åðéêïéíùíßáò.
óôï Ó÷Þìá 3.
Êáé ïé äýï ëýóåéò Ý÷ïõí óçìáíôéêÜ ðëåïíåêôÞìáôá, ìåôáîý ôùí ïðïßùí ôï óçìáíôéêüôåñï åß-
Ç ×ñÞóç ôïõ Ethernet Åíüò Æåýãïõò óôçí
íáé üôé ôï Ethernet åßíáé ðáãêïóìßùò äéáäåäï-
Áõôïêéíçôïâéïìç÷áíßá
ìÝíï, ôüóï óôïí êüóìï ôçò ôå÷íïëïãßáò ðëçñï-
Ç ÷ñÞóç åíüò ìüíï ðñùôïêüëëïõ ãéá ôçí õðï-
öïñéþí (Information Technology - IT), üóï êáé
óôÞñéîç åíüò ìåãÜëïõ ðëÞèïõò ëåéôïõñãéþí Ý-
SPRING 2022
COMMUNICATION SOLUTIONS
29
Ethernet
Õðïëïãéóôéêü ÍÝöïò (ÉÔ)
Êôßñéï Ãñáöåßùí (ÉÔ)
100BASE-T1L
100BASE-T1L
ÅñãïóôÜóéá (ÏÔ)
ÅëåãêôÝò Åñãïóôáóßïõ/ Êôéñßïõ
100BASE-T1L 100BASE-T1, 1000BASE-T1, 100BASE-TX Þ 1000BASE-TX ÅëåãêôÝò
ÃñáììÞ ÐáñáãùãÞò/ ¸ëåã÷ïò Äéáäéêáóéþí (ÏÔ)
Ðñïãñáììáôéæüìåíåò áðü ëïãéóìéêü É/Ï
100BASE-T1S
100BASE-T1S
Áêñáßá Óçìåßá (ÏÔ)
Ó÷Þìá 3. Ðþò ôï Ethernet åêôåßíåôáé áðü ôï äßêôõï ôùí áêñáßùí óçìåßùí ìÝ÷ñé ôï õðïëïãéóôéêü íÝöïò
30
÷åé ôåñÜóôéá ïöÝëç óôçí áõôïêéíçôïâéïìç÷áíßá
ôï óõíïëéêü ôïõò ìÞêïò åßíáé ðåñßðïõ 4km êáé
ðïõ áíôéìåôùðßæåé ôçí õðïóôÞñéîç ü÷é ìüíï å-
ôï âÜñïò ôïõò áããßæåé ìÝ÷ñé êáé ôá 113kg. Ïé
íüò óõãêåêñéìÝíïõ äéáýëïõ åðéêïéíùíßáò
äéÜöïñïé ôýðïé êáëùäßùí ðïõ áðáéôïýíôáé ãéá
(CAN), áëëÜ êáé ðïëëáðëþí åéäßùí ùò ðñïò ôçí
ôéò äéÜöïñåò åöáñìïãÝò åìöáíßæïõí åðßóçò
åöáñìïãÞ (Application-specific) ðñïôýðùí. ÊÜ-
èÝìáôá çëåêôñïìáãíçôéêÞò óõìâáôüôçôáò
èå ÷ñüíï áíáðôýóóïíôáé âåëôéþóåéò óôá Ðñï-
(ElectroMagnetic Compatibility - EMC), ìéáò êáé
çãìÝíá ÓõóôÞìáôá ÕðïâïÞèçóçò (Advanced
ç êáèåìßá áðü áõôÝò Ý÷åé ôéò äéêÝò ôçò áðáéôÞ-
Driver-Assistance Systems - ADAS), ôá ïðïßá
óåéò.
óõ÷íÜ ðëÝïí áðáéôïýí íÝåò êÜìåñåò, radar, áé-
Ãéá íá áíôáðïêñéèåß óôéò áðáéôÞóåéò ôùí áõôï-
óèçôÞñåò õðåñÞ÷ùí êáé áéóèçôÞñåò áíß÷íåõ-
êéíÞôùí ðïõ óýíôïìá èá ÷ñçóéìïðïéïýí åêá-
óçò öùôüò êáé ìÝôñçóçò áðüóôáóçò (Light
ôïíôÜäåò åêáôïììýñéá ãñáììÝò êþäéêá óå óý-
Detection And Ranging - LiDAR) ìåëëïíôéêÜ, êá-
ãêñéóç ìå ôéò 100 åêáôïììýñéá ãñáììÝò óÞìå-
èþò êáé áëëáãÝò óôá óõóôÞìáôá åíçìåñùäéá-
ñá, ç áõôïêéíçôïâéïìç÷áíßá ìåôáâáßíåé óå ìéá
óêÝäáóçò (Infotainment) êáé ðëïÞãçóçò.
âáóéóìÝíç óôï Ethernet æùíéêÞ (Zonal) çëå-
ÓÞìåñá, óôá óýã÷ñïíá ï÷Þìáôá õðÜñ÷ïõí 40
êôñïíéêÞ/çëåêôñéêÞ (Electronic/Electrical- E/E)
äéáöïñåôéêÝò ðëåîïýäåò êáëùäßùóçò, 80 Ýùò
áñ÷éôåêôïíéêÞ, ç ïðïßá óõãêåíôñþíåé ôïõò áé-
100 ÇëåêôñïíéêÝò ÌïíÜäåò ÅëÝã÷ïõ (Electronic
óèçôÞñåò ìå ìéá åíéáßá óýíäåóç áðü ôç æþíéêç
Control Unit - ECU) êáé Üëëá 300 êáëþäéá ðïõ
ðýëç (Zonal Gateway) óå Ýíá äßêôõï êïñìïý. Ç
COMMUNICATION SOLUTIONS
SPRING 2022
Ethernet
ìåôÜâáóç áõôÞ áðåéêïíßæåôáé óôï Ó÷Þìá 4.
äéáöïñåôéêÝò ôå÷íïëïãßåò åðéêïéíùíßáò ãéá ôç
Ïé óýã÷ñïíåò ðëÝïí ëýóåéò ôçò áõôïêéíçôïâéï-
äéáóýíäåóç ôùí óõóêåõþí ôïõò, îåêéíþíôáò á-
ìç÷áíßáò âáóßæïíôáé ó÷åäüí åî ïëïêëÞñïõ óôï
ðü ôçí ôå÷íïëïãßá åðéêïéíùíßáò ìåôáîý ïëïêëç-
Ethernet, ôïõ ïðïßïõ ïé äõíáôüôçôåò âõóìÜôù-
ñùìÝíùí êõêëùìÜôùí (Inter-Integrated Circuit -
óçò êáé ëåéôïõñãßáò (Plug-and-Play) åßíáé ìï-
I2C) Ýùò ôçí RS-485, ôçí ÊáèïëéêÜ Áóýã÷ñï-
íáäéêÜ ðñïóáñìïóìÝíåò óôá õðçñåóéïóôñåöÞ
íç (åðéêïéíùíßá) ÄÝêôç-Ðïìðïý (Universal
(Service-oriented) ðåñéâÜëëïíôá ðïõ èá êáèï-
Asynchronous Receiver-Transmitter - UART)
ñßóïõí ôá ï÷Þìáôá óôï ìÝëëïí. Ïé óõóêåõÝò èá
êáé ôçí äéáýëïõ Äéêôýïõ Åëåãêôþí (Controller
ìðïñïýí íá óõíäåèïýí êáé íá áðïóõíäåèïýí
AreaNetwork- CAN), êáé óõíäÝïõí ôá ðÜíôá, á-
óå ðñáãìáôéêü ÷ñüíï, ÷ùñßò ÷ñüíï åêôüò ëåé-
ðü ôçí êáëùäßùóç ôïõ ðßíáêá åëÝã÷ïõ Ýùò
ôïõñãßáò (Downtime), Ýíá óçìáíôéêü ðëåïíÝ-
ôïõò áéóèçôÞñåò èåñìïêñáóßáò, ôïõò åíåñãï-
êôçìá Ýíáíôé ôùí äéáýëùí åðéêïéíùíßáò CAN.
ðïéçôÝò ÈÝñìáíóçò, Åîáåñéóìïý êáé Êëéìáôé-
Ùóôüóï, ï äßáõëïò åðéêïéíùíßáò CAN ðïõ Ý÷åé
óìïý (Heating, Ventilation, and AirConditioning
õðçñåôÞóåé áîéüðéóôá ôçí áõôïêéíçôïâéïìç÷á-
HVAC), ôïõò áíåëêõóôÞñåò, ôïõò áíåìéóôÞñåò,
íßá ãéá ðïëëÜ ÷ñüíéá êáé èá óõíå÷ßæåé íá ôï êÜ-
ôïõò ðáñáêïëïõèçôÝò ôÜóçò (Voltage Monitor),
íåé ãéá åêåßíåò ôéò åöáñìïãÝò ðïõ èåùñåßôáé
ôïõò dc-dc ìåôáôñïðåßò, êáèþò êáé Üëëåò ìï-
êáôáëëçëüôåñï, èá äéáôçñçèåß ðéèáíüôáôá ãéá
íÜäåò, êáé ôá ïðéóèåðßðåäá õðïëïãéóôþí. Ðïë-
áñêåôÜ ÷ñüíéá áêüìá.
ëÝò áðü áõôÝò ôéò óõóêåõÝò áðáéôïýí ÷áìçëïýò ìüíï ñõèìïýò ìåôÜäïóçò äåäïìÝíùí,
Ìéá êáé ìüíç Âéïìç÷áíéêÞ Ëýóç
óýìöùíá ìå ôá ðñüôõðá.
Áí êáé ç áõôïêéíçôïâéïìç÷áíßá åðùöåëåßôáé ðå-
Ðáñüëï ðïõ äåí áðïôåëåß áêüìç êýñéï èÝìá
ñéóóüôåñï áðü ôï 10BASE-T1S, ï âéïìç÷áíéêüò
óõæÞôçóçò, ôï 10BASE-T1S êáé ôï 10BASE-T1L
ôïìÝáò ìðïñåß íá åðùöåëçèåß óçìáíôéêÜ ôüóï
ìðïñåß íá äéáäñáìáôßóåé âáóéêü ñüëï óôï IoT,
áðü ôï 10BASE-T1S, üóï êáé áðü ôï 10BASE-
óõíäÝïíôáò óõóêåõÝò ðïõ äéáöïñåôéêÜ èá ÷ñç-
T1L ãéá äéÜöïñïõò ëüãïõò. Ðñþôïí, ïé âéïìç-
óéìïðïéïýóáí ìßá áðü ôéò õöéóôÜìåíåò áóýñ-
÷áíéêÝò åãêáôáóôÜóåéò ÷ñçóéìïðïéïýí ðïëëÝò
ìáôåò ëýóåéò ìéêñÞò åìâÝëåéáò, üðùò ç Zigbee,
ÄéêôõáêÝò ÌåãáÔÜóåéò ÊáôáíåìçìÝíåò, ìÝóù õëéóìéêïý
ÊåíôñéêÝò, ìÝóù ëïãéóìéêïý
Ðýëåò ìåôáîý äéáöïñåôéêþí ôå÷íïëïãéþí åðéêïéíùíßáò
Ethernet: 10Base-T1S, 100Base-T1 1000Base-T1, NGBase-T1, 10G+
ÅéäéêÝò áíÜ ôïìÝá áñ÷éôåêôïíéêÝò õëéóìéêïý Ðïëëáðëïß äßáõëïé åßäéïé ùò ðñïò ôçí åöáñìïãÞ ÊáôáíåìçìÝíåò ðýëåò Ðïëýðëïêç êáëùäßùóç
ÄéáöïñåôéêÝò Æþíåò ìéáò Åðé÷åßñçóçò óõíäåäåìÝíåò ìå ìéá êåíôñéêïðïéçìÝíç õðïëïãéóôéêÞ ðëáôöüñìá Äßêôõï Ethernet âáóéóìÝíï óôï IP ×áìçëïý êüóôïõò êáëùäßùóç åíüò æåýãïõò (Ô1) óôá Üêñá
Éó÷õñü êáé åõÝëéêôï äßêôõï ãéá ôçí áíôéìåôþðéóç ôùí âéïìç÷áíéêþí ðñïêëÞóåùí
Ó÷Þìá 4. Ïé ÌÝãáÔÜóåéò ôçò äéêôýùóçò ôùí áõôïêéíÞôùí êáé ç ìåôÜâáóç óå ìéá æùíéêÞ çëåêôñïíéêÞ/çëåêôñéêÞ áñ÷éôåêôïíéêÞ ðïõ âáóßæåôáé óôï Ethernet SPRING 2022
COMMUNICATION SOLUTIONS
31
Ethernet
ç Bluetooth Þ ç Wi-Fi. Ïé ðñþôïé ÷ñÞóôåò ðïõ ðñïóðÜèçóáí íá õëïðïéÞóïõí áóýñìáôåò óõíäÝóåéò ìå ôï IoT ëÝíå, üôé åßíáé ðïëý ðéï åýêïëï íá ëåò üôé èá êÜíåéò ôçí áóýñìáôç ëýóç íá «ðáßîåé» óôï IoT, ðáñÜ íá ôï êÜíåéò. Ïé ëýóåéò áóýñìáôçò äéáóýíäåóçò ìðïñåß íá ðáßîïõí ðñïöáíþò êÜðïéï ñüëï óôï âéïìç÷áíéêü IoT, áëëÜ äåí ìðïñåß íá áðïôåëÝóïõí êáé ôéò ìïíáäéêÝò, ëáìâÜíïíôáò õðüøç ôá ïöÝëç ôïõ Ethernet. ÅðéðëÝïí, ç äõíáôüôçôá õðïóôÞñéîçò ðïëëáðëþí ôåñìáôéêþí óôï 10BASE-T1S åðéôñÝðåé ôç óýíäåóç, áöáßñåóç Þ áíôéêáôÜóôáóç ðïëëþí óõóêåõþí ÷ùñßò íá åðçñåÜæåôáé ç óõíïëéêÞ áðüäïóç ôïõ äéêôýïõ êáé ç äéáäéêáóßá åßíáé ðïëý áðëÞ. ÔÝëïò, ôï Ethernet èá õðÜñ÷åé ó÷åäüí óå êÜèå åãêáôÜóôáóç, åðïìÝíùò ç ìåôÜâáóç áðü ôï õðïëïãéóôéêü íÝöïò (cloud) óôá Üêñá åíüò äéêôýïõ ìðïñåß íá åðéôåõ÷èåß ìå ôçí ÷ñÞóç åíüò êáé ìüíï ðñïôýðïõ. Åßíáé åðßóçò óçìáíôéêü íá óçìåéùèåß üôé êáèþò ç âéïìç÷áíßá ìåôáâáßíåé óôçí ôÝôáñôç ãåíéÜ ôçò, ç æùíéêÞ ðñïóÝããéóç åöáñìüæåôáé êáé óå áõôÞí ôçí ðåñßðôùóç ìå ôï Ethernet íá áðïôåëåß ôçí ðëÝïí åíäåäåéãìÝíç ëýóç. ÕðÜñ÷ïõí êáé Üëëá ðëåïíåêôÞìáôá, ðïõ áðü ìüíá ôïõò êÜíïõí ôo Ethernet Åíüò-Æåýãïõò (SPE) ðïëý åëêõóôéêü. Ç äïìÞ åíüò ðïìðïäÝêôç Ç åöáñìïãÞ ôïõ 10BASE-T1S áðáéôåß óõãêåêñéìÝíïõò ðïìðïäÝêôåò Ethernet. ¸íá ðáñÜäåéãìá ðïìðïäåêôþí ðïõ õðïóôçñßæïõí ôï 10BASET1S, åßíáé ç ïéêïãÝíåéá ðïìðïäåêôþí Ethernet LAN867x ôçò Microchip. Ï LAN8670/1/2 åðéôñÝðåé ôç äçìéïõñãßá ôïðïëïãéþí äéêôýïõ, ôüóï ðïëëáðëþí ôåñìáôéêþí üóï êáé äéóçìåéáêþí. Õðïóôçñßæïíôáé äéóçìåéáêÜ ôìÞìáôá æåýîçò ìÞêïõò Ýùò êáé 15m êáé ç ëåéôïõñãßá ðïëëáðëþí ôåñìáôéêþí, ìå ôïõëÜ÷éóôïí Ýùò êáé ïêôþ ðïìðïäÝêôåò óõíäåäåìÝíïõò óå Ýíá êïéíü ôìÞìá ìßîçò, ìå ìÞêïò Ýùò êáé 25m. Áîßæåé íá óçìåéùèåß üôé áêüìá êáé óôá ðñüôõðá ôçò ÉÅÅÅ áíáöÝñïíôáé ôá åëÜ÷éóôá êáé ôá ìÝ32
COMMUNICATION SOLUTIONS
ãéóôá üñéá. ÅðïìÝíùò, ðåñéóóüôåñïé êüìâïé êáé ìåãáëýôåñåò áðïóôÜóåéò ìðïñåß íá åßíáé åöéêôÜ üôáí ïé õëïðïéçôÝò (Implementer) åíüò óõóôÞìáôïò ìðïñïýí íá åðáëçèåýóïõí ôçí ïñèÞ ëåéôïõñãßá ôïõò. Ï ðïìðïäÝêôçò LAN8670/1/2 ëåéôïõñãåß ìå ìéá ìüíï ðáñï÷Þ ôùí 3,3Vdc êáé Ý÷åé åíóùìáôùìÝíï óôáèåñïðïéçôÞ óôá 1,8Vdc. Ìðïñåß íá ÷ñçóéìïðïéçèåß óå äõóìåíÞ ðåñéâÜëëïíôá,åöüóïí ôï åýñïò èåñìïêñáóßáò ðïõ õðïóôçñßæåé åßíáé áðü -40°C Ýùò +125°C êáé óõììïñöþíåôáé ìå ôéò âéïìç÷áíéêÝò áðáéôÞóåéò EMC êáé EMI. Ï LAN8670/1/2 õðïóôçñßæåé ôçí åðéêïéíùíßá ìå ôï Ethernet MAC ìÝóù ôõðéêþí äéåðáöþí MII/ RMII êáé ìéáò åíóùìáôùìÝíçò äéåðáöÞò óåéñéáêÞò äéá÷åßñéóçò, ç ïðïßá ðáñÝ÷åé ãñÞãïñç ðñüóâáóç êáé äéáìüñöùóç ôïõ êáôá÷ùñçôÞ ìå óõ÷íüôçôá ìÝ÷ñé êáé 4MHz. Ç ðñüóâáóç óôï öõóéêü ìÝóï õëïðïéåßôáé åßôå ìÝóù ôïõ CSMA/ CD åßôå ôïõ PLCA, åðéôñÝðïíôáò ôç ÷ñÞóç õøçëïý åýñïõò æþíçò ìå ôçí áðïöõãÞ óõãêñïýóåùí óôï öõóéêü åðßðåäï êáé ôç ëåéôïõñãßá ñéðÞò ãéá ôçí ìåôÜäïóç ðïëëáðëþí ðáêÝôùí ãéá åöáñìïãÝò õøçëïý ñõèìïý ðáêÝôùí êáé åõáßóèçôùí óôç ëáíèÜíïõóá êáèõóôÝñçóç (latency). Ïé Ðñïôåéíüìåíïé Óýíäåóìïé Ç ìç÷áíéêÞ äéåðáöÞ ìå ôçí éóïóôáèìéóìÝíç êáëùäßùóç åßíáé Ýíáò óýíäåóìïò 3 áêßäùí, ìå ôá óÞìáôá BI_DA+ êáé BI_DA- êáé ìå ðñïáéñåôéêÞ ôçí ÈùñÜêéóç (Shield) Þ åíáëëáêôéêÜ Ýíáò óýíäåóìïò 2 áêßäùí ìå ìéá ðñïáéñåôéêÞ ðñüóèåôç óýíäåóç ìç÷áíéêÞò èùñÜêéóçò. Ïé óýíäåóìïé ðïõ ðëçñïýí ôéò ìç÷áíéêÝò áðáéôÞóåéò ôïõ ðñüôõðïõ CENELEC EN IEC 631711 Þ ôïõ CENELEC EN IEC 63171-6:2020 ìðïñïýí íá ÷ñçóéìïðïéçèïýí ùò ìç÷áíéêÞ äéáóýíäåóç ìå ôçí éóïóôáèìéóìÝíç êáëùäßùóç. Ï åëåýèåñïò óýíäåóìïò (Free Connector) ÷ñçóéìïðïéåßôáé ìå ôçí éóïóôáèìéóìÝíç êáëùäßùóç êáé o óôáèåñüò óýíäåóìïò (Fixed Connector) MDI ìå ôï Öõóéêü åðßðåäï (PHY). Ï åëåýèåñïò êáé o óôáèåñüò óýíäåóìïò óýìöùíá ìå ôï SPRING 2022
ÅîùôåñéêÞ MCU
10Mb/s Ethernet MAC
MII/RMII
MODEL[1:0]
PHYAD[4:0]
SMI
Ethernet
LAN8670/1/2
TRXN
MDI-
TRXN
MDI+
Êñýóôáëëïò Þ ÔáëáíôùôÞò Ñïëïãéïý Ó÷Þìá 5. Ìðëïê äéÜãñáììá åðéðÝäïõ óõóôÞìáôïò LAN8670/1/2
ðñüôõðï CENELEC EN IEC 63171-1 áðåéêïíß-
Ç áíôéóôïß÷éóç ôùí áêßäùí ôïõ Ó÷Þìáôïò 6óô,
æïíôáé (ìüíï ãéá åíçìÝñùóç) óôï Ó÷Þìá 6á êáé
êáèþò êáé ôá óÞìáôá ðïõ ìåôáöÝñïõí ðåñé-
óôï Ó÷Þìá 6â áíôßóôïé÷á, åíþ ç äéåðáöÞ óõ-
ãñÜöïíôáé óôïí Ðßíáêá 2.
íáñìïãÞò (Mating Interface) áðåéêïíßæåôáé óôï Ó÷Þìá 6ã. Ï åëåýèåñïò êáé o óôáèåñüò óýíäå-
ÓõìðåñÜóìáôá
óìïò óýìöùíá ìå ôï ðñüôõðï CENELEC EN
Ç Ýêäïóç ôïõ Ethernet Åíüò-Æåýãïõò (SPE)
IEC 63171-6 áðåéêïíßæïíôáé (ìüíï ãéá åíçìÝñù-
ðñïôýðïõ 802.3cg ôçò IEEE äåí èá ìðïñïýóå
óç) óôï Ó÷Þìá 6ä êáé óôï Ó÷Þìá 6å áíôßóôïé÷á,
íá Ýñèåé óå êáëýôåñç óôéãìÞ, êáèþò ç Âéïìç-
åíþ ç äéåðáöÞ óõíáñìïãÞò áðåéêïíßæåôáé óôï
÷áíßá 4.0 (Industry 4.0) áñ÷ßæåé íá åîåëßóóåôáé.
Ó÷Þìá 6óô.
Ç Âéïìç÷áíßá 4.0 êáé ç áõôïêéíçôïâéïìç÷áíßá
(á) Âýóìá óýìöùíá ìå ôï IEC 63171-1
(ä) Âýóìá óýìöùíá ìå ôï IEC 63171-6
(â) Õðïäï÷Þ óýìöùíá ìå ôï IEC 63171-1
(å) Õðïäï÷Þ óýìöùíá ìå ôï IEC 63171-6
(ã) ¼øç óõíáñìïãÞò óýìöùíá ìå ôï IEC 63171-1
(óô) ¼øç óõíáñìïãÞò óýìöùíá ìå ôï IEC 63171-6
Ó÷Þìá 6. Ðñïôåéíüìåíïé óýíäåóìïé óýìöùíá ìå ôá ðñüôõðá CENELEC EN IEC 63171-1 êáé CENELEC EN IEC 63171-6 34
COMMUNICATION SOLUTIONS
SPRING 2022
Ethernet
Áêßäá 1 2
ÓÞìá BI_DA+ BI_DA-
Ðßíáêáò 2. Áíôéóôïß÷éóç áêßäùí êáé óçìÜôùí ôïõ óõíäÝóìïõ ôïõ Ó÷Þìáôïò 6óô
áãùíßæïíôáé ãéá ôçí áðëïðïßçóç ôïõ ôåñÜóôéïõ ðñïâëÞìáôïò ôçò óõíäåóéìüôçôáò, åíþ ðñïóèÝôïõí ðåñéóóüôåñïõò áéóèçôÞñåò êáé Üëëåò óõíäÝóéìåò óõóêåõÝò êÜèå ÷ñüíï. Ôï 10BASE-T1S êáé ôï 10BASE-T1L áíïßãïõí ôïí äñüìï ãéá ôçí åðÝêôáóç ôçò åìâÝëåéáò ôïõ Ethernet óôçí Üêñç ôïõ äéêôýïõ, ðáñÝ÷ïíôáò õðïóôÞñéîç óå óõóêåõÝò ÷áìçëïý ñõèìïý ìåôÜäïóçò äåäïìÝíùí ðïõ äåí ÷ñåéÜæïíôáé ôá÷ýôçôåò ôçò ôÜîåùò åíüò gigabit, ÷ñçóéìïðïéþíôáò ãñáììÝò ìåôáöïñÜò äýï áãùãþí. Åí ïëß-
ãïéò, ôá ðáñáðÜíù ðñùôüêïëëá åðéêïéíùíßáò Ý÷ïõí ôç äõíáôüôçôá íá áëëÜîïõí äñáìáôéêÜ ôïí ôñüðï óýíäåóçò áõôþí ôùí óõóêåõþí óå ó÷Ýóç ôüóï ìå ôéò âéïìç÷áíéêÝò ñõèìßóåéò, üóï êáé ìå ôïí êÜèå ôýðï ï÷Þìáôïò. ÂÉÂËÉÏÃÑÁÖIÁ I. IEEE Std 802.3cg™, Physical Layers Specifications and Management Parameters for 10 Mb/s Operation and Associated Power Delivery over a Single Balanced Pair of Conductors, November 2019. ii. Henry Muyshondt, "Single-Pair Ethernet Comes Just in Time", Electronic Design, Industrial Automation, March 2022. iii. LAN8670/1/2, 10BASE-T1S Ethernet PHY Transceiver, Microchip Technology Inc., 2021. iv. CENELEC EN IEC 63171-1, Connectors for electrical and electronic equipment - Part 1: Detail specification for twoway, shielded or unshielded, free and fixed connectors Mechanical mating information, pin assignment and additional requirements for Type 1 copper LC style v. CENELEC EN IEC 63171-6, Connectors for electrical and electronic equipment - Part 6: Detail specification for 2-way and 4-way (data/power), shielded, free and fixed connectors for power and data transmission with frequencies up to 600 Mhz.
Ëßãá ëüãéá ãéá ôïí áñèñïãñÜöï Ï ê. ÄçìÞôñçò Öéëßððïõ åßíáé Ôå÷íéêüò ÄéåõèõíôÞò óôçí Åôáéñåßá Integrated Intelligent Quality Systems (I2QS). Óå äéåèíÝò åðßðåäï áðïôåëåß ìÝëïò ôïõ Communication Society ôïõ INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) áðü ôï 1995 êáé Senior Member ôïõ IEEE áðü ôï 2020. Åßíáé Country Chair ôïõ BICSI óôçí ÅëëÜäá êáé ìÝëïò ôïõ áðü ôï 2001. ÅðéðëÝïí, áðïôåëåß ìÝëïò ùò Professional Engineer óôï CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) áðü ôï 2018, êáèþò åðßóçò åßíáé ìÝëïò ùò Consultant óôï ETHERNET ALLIANCE (EA) áðü ôï 2019. ÅñãÜæåôáé óôïí ÷þñï ôçò ðëçñïöïñéêÞò êáé ôùí ôçëåðéêïéíùíéþí áðü ôï 1995, îåêéíþíôáò ùò ìç÷áíéêüò Ýñåõíáò, ó÷åäßáóçò êáé áíÜðôõîçò ôçëåðéêïéíùíéáêþí óõóôçìÜôùí (Hardware Design). Óôçí óõíÝ÷åéá áó÷ïëÞèçêå ìå ôçí ó÷åäßáóç êáé áíÜðôõîç ôçëåðéêïéíùíéáêþí äéêôýùí, åíþ ôáõôü÷ñïíá åðéêåíôñþèçêå óôçí ìåëÝôç êáé áíÜðôõîç ôçëåðéêïéíùíéáêþí êáëùäéáêþí õðïäïìþí, ðáñáêïëïõèþíôáò åíåñãÜ üëá áõôÜ ôá ÷ñüíéá ôçí áíÜðôõîç êáé åîÝëéîç ôùí Åõñùðáúêþí êáé Äéåèíþí ðñïôýðùí. Óå åèíéêü åðßðåäï, óõììåôÝ÷åé åíåñãÜ óôçí åèíéêÞ Ôå÷íéêÞ ÅðéôñïðÞ ÔÅ93 ôïõ ÅËÏÔ áðü ôï 2007, åêðñïóùðþíôáò ôçí ðáñÜëëçëá óôçí åõñùðáúêÞ Ôå÷íéêÞ ÅðéôñïðÞ TC215 ôçò CENELEC. Óå åõñùðáúêü åðßðåäï, óõììåôÝ÷åé ùò ìÝëïò óôï Working Group 1 (WG1) êáé óôï Working Group 2 (WG2) ôçò TC215 ôçò CENELEC (EN 50173 êáé EN 50174) áðü ôï 2007. Ôá Working Groups áõôÜ åßíáé áñìüäéá ãéá ôçí áíÜðôõîç ìéáò ïëïêëçñùìÝíçò óåéñÜò ðñïôýðùí ãéá ôçí ó÷åäßáóç êáé ôçí åãêáôÜóôáóç ôùí ôçëåðéêïéíùíéáêþí êáëùäéáêþí õðïäïìþí óå ìéá óåéñÜ åãêáôáóôÜóåùí, óõìðåñéëáìâÜíïíôáò ìåôáîý Üëëùí, ãñáöåßá, âéïìç÷áíßåò, óðßôéá êáé êÝíôñá äåäïìÝíùí. ÅðéðëÝïí, óõììåôÝ÷åé óôéò åñãáóßåò ôïõ Working Group 3 (WG3) ôçò CLC TC215 ãéá ôçí óåéñÜ ðñïôýðùí EN 50600 áðü ôï 2007, åîåôÜæïíôáò ôçí åöáñìïãÞ ôçò åíåñãåéáêÞò áðüäïóçò óôéò åãêáôáóôÜóåéò êáé ôéò õðïäïìÝò åíüò êÝíôñïõ äåäïìÝíùí. Óå äéåèíÝò åðßðåäï, óõììåôÝ÷åé åíåñãÜ óôá Subcommittee Power over Ethernet (PoE), High Speed Networking (HSN) êáé Single Pair Ethernet (SPÅ) ôïõ ÅÁ. ¸÷åé ãñÜøåé Ýíá ðëÞèïò Üñèñùí ó÷åôéêÜ ìå ôá äéåèíÞ, åõñùðáúêÜ êáé åèíéêÜ ðñüôõðá ðïõ ÷ñçóéìïðïéïýíôáé óôçí ó÷åäßáóç êáé áíÜðôõîç óõóôçìÜôùí ãÝíéáò êáëùäßùóçò êáé åßíáé ïìéëçôÞò óå áíôßóôïé÷ï ðëÞèïò äéáëÝîåùí êáé óåìéíáñßùí, åíçìåñþíïíôáò ôçí åëëçíéêÞ áãïñÜ ãéá ôéò åîåëßîåéò êáé ôçí ðñüïäï ôùí ðñïôýðùí ôùí ôçëåðéêïéíùíéáêþí êáëùäéáêþí õðïäïìþí.
ÅÜí åðéèõìåßôå ôï COMMUNICATION SOLUTIONS íá äçìïóéåýóåé ðåñéóóüôåñá Üñèñá ãéá Ethernet åðéêïéíùíÞóôå ìáæß ìáò óôï: info@comsol.gr
SPRING 2022
COMMUNICATION SOLUTIONS
35
Video Conference
Cloud Video Services Features 2022 åßäç óõóêÝøåùí êáé ìÝèïäïé ðñüóâáóçò
¢ñèñï ôïõ Äéïíýóç ÆÝñâá Unified Communications Engineer e-mail: dzervas@confguru.com
ÌÝñïò 1 Ïé õðçñåóßåò Cloud Video óÞìåñá
ðáñáêïëïýèçóçò (Management & Monitoring
Ïé õðçñåóßåò Cloud Video åßíáé ç óçìåñéíÞ
System) êáèþò êáé ôï óýóôçìá äéá÷åßñéóçò
ìïñöÞ ìå ôçí ïðïßá ðáñÝ÷åôáé óå åôáéñéêïýò
êëÞóåùí (Call Control). Êáé óå ðéï ðñüóöáôåò õ-
÷ñÞóôåò ç äõíáôüôçôá ôçëåäéÜóêåøçò.
ðïäïìÝò "On-Premise" Üñ÷éóáí íá ÷ñçóéìïðïé-
Ðáëáéüôåñá, ç ôçëåäéÜóêåøç Þôáí õðçñåóßá
ïýíôáé êáé óõóôÞìáôá ðñüóâáóçò ìÝóù Web
ôçí ïðïßá õëïðïéïýóáí "On-Premise" åôáéñåßåò
Browser.
êáé ïñãáíéóìïß, ðáñÝ÷ïíôáò óôïõò ÷ñÞóôåò äõ-
ÐñïïäåõôéêÜ Üñ÷éóáí íá ðáñïõóéÜæïíôáé õðç-
íáôüôçôåò ôçëåäéÜóêåøçò. Áõôü áðáéôïýóå ôçí
ñåóßåò Cloud Video, ïé ïðïßåò áðïôåëïýí ôçí
åãêáôÜóôáóç áêñéâïý åîïðëéóìïý ìå õøçëÝò
ìåôåîÝëéîç ôçò åóùôåñéêÞò ðëáôöüñìáò Video.
áíÜãêåò óõíôÞñçóçò êáé áíÜãêç åîåéäéêåõìÝ-
Ïé õðçñåóßåò áõôÝò ïõóéáóôéêÜ ìåôáöÝñïõí
íçò ãíþóçò êáé äéá÷åßñéóçò.
ôçí êåíôñéêÞ õðïäïìÞ óôï Cloud, äçëáäÞ å-
¸íá óýóôçìá "On Premise" áðïôåëåßôáé êáô'
êôüò ôçò åôáéñåßáò. ¸ôóé, ç ÷ñÞóç ôçò õðïäï-
áñ÷Þí áðü ôçí MCU ç ïðïßá åßíáé ôï âáóéêü
ìÞò ðáñÝ÷åôáé óáí õðçñåóßá.
óôïé÷åßï êáé ðáñÝ÷åé ôç äõíáôüôçôá ðïëëáðëÞò
ÕðÜñ÷ïõí ðïëëáðëÜ ðëåïíåêôÞìáôá ðïõ ðñï-
äéáóýíäåóçò óå Virtual Meeting Rooms. Åðß-
Ýêõøáí áðü áõôÞ ôçí áëëáãÞ êáé áíáöÝñïíôáé
óçò, õðÜñ÷åé ôï óýóôçìá Firewall Traversal ðïõ
óõíïðôéêÜ:
óõíåñãÜæåôáé ìå ôï Firewall ãéá ôçí áóöáëÞ
l Ìåßùóç áñ÷éêÞò åðÝíäõóçò (áðü CapEX
åðéêïéíùíßá åêôüò ôïõ åôáéñéêïý äéêôýïõ. ÅðéðëÝïí õðÜñ÷ïõí ôï óýóôçìá äéá÷åßñéóçò êáé 36
COMMUNICATION SOLUTIONS
ðñïò OpEX) l Äõíáôüôçôá ìåñéêÞò ÷ñÞóçò ôçò õðïäïìÞò, SPRING 2022
Video Conference
Üñá êáé äõíáôüôçôá ÷ñÞóçò áðü åôáéñåßåò
ôçëåäéÜóêåøçò (video endpoints).
ðïõ äåí èá ìðïñïýóáí íá áíôáðåîÝëèïõí
¸íáò åíáëëáêôéêüò üñïò ðïõ ÷ñçóéìïðïéåßôáé
ïéêïíïìéêÜ óå ìßá åóùôåñéêÞ åãêáôÜóôáóç
áðü êÜðïéïõò ðáñü÷ïõò êáé êáôáóêåõáóôÝò
ðëÞñïõò õðïäïìÞò ôçëåäéÜóêåøçò.
óõóôçìÜôùí ôçëåäéÜóêåøçò åßíáé ôï VMR ðïõ
l Áýîçóç ôçò äéáèÝóéìçò ÷ùñçôéêüôçôáò óõì-
óçìáßíåé Virtual Meeting Room. O üñïò áõôüò
ìåôå÷üíôùí áðü ìåñéêÝò äåêÜäåò óå åêáôï-
óõíáíôÜôáé êõñßùò óå óõóôÞìáôá MCU óå
íôÜäåò Þ êáé ÷éëéÜäåò.
åãêáôáóôÜóåéò "on-premise".
l Äåí õðÜñ÷åé ç áíÜãêç åéäéêþí ñõèìßóåùí
Ôï Meeting Room Ý÷åé óõíÞèùò Ýíáí ìïíáäéêü
äéêôýïõ ãéá ôçí ðñüóâáóç ôùí ÷ñçóôþí.
áñéèìü ðïõ ôï ÷áñáêôçñßæåé. Åßíáé ðñïóâÜóé-
l ¢ìåóç
åíåñãïðïßçóç êáé ÷ñÞóç ôùí
õðçñåóéþí.
ìï ìÝóù Web Browser, ìå ôç ÷ñÞóç åíüò ìïíáäéêïý URL. Åðßóçò ìðïñåß êÜðïéïò íá êáëÝóåé Ýíáí ôçëåöùíéêü áñéèìü êáé íá óõíäåèåß ìå
ÃåíéêÜ ÷áñáêôçñéóôéêÜ êáé ïñïëïãßá ×ñÞóç Ïñïëïãßáò Ïé ðáñáêÜôù üñïé ðïõ ÷ñçóéìïðïéïýíôáé åßíáé ïé åðéêñáôÝóôåñïé. ÊÜèå êáôáóêåõáóôÞò êáé õðçñåóßá ðïëëÝò öïñÝò åðéëÝãïõí äéáöïñåôéêïýò üñïõò ìå ôïõò ïðïßïõò áíáöÝñïíôáé óå êÜðïéï ÷áñáêôçñéóôéêü, Þ äéáöïñåôéêÞ åñìç-
ôï óõãêåêñéìÝíï Meeting Room, áöïý åéóÜãåé ðñþôá ôïí áñéèìü ôïõ äùìáôßïõ. ¸ôóé ëïéðüí, ôá âáóéêÜ óôïé÷åßá ðñüóâáóçò ãéá ôïõò óõììåôÝ÷ïíôåò åßíáé üðùò óôï ðáñÜäåéãìá: Meeting Room Number: 2350700 Connection URL: https://domain.com/
íåßá ãíùóôþí üñùí. Ôá ðáñáêÜôù âáóßæïíôáé
meetings/2350700
óôïõò ðéï óõíçèéóìÝíïõò üñïõò êáé óôéò ðéï
PSTN call: +30 210 1234567 & conference ID
ãíùóôÝò åñìçíåßåò.
2350700.
Meeting Rooms To Meeting Room åßíáé ï ðñþôïò üñïò ðïõ èá ðñÝðåé íá ìåëåôçèåß, üóïí áöïñÜ ôéò õðçñåóßåò ôçëåäéÜóêåøçò. Åßíáé Ýíáò éäåáôüò ÷þñïò óýóêåøçò ìå ôç äõíáôüôçôá äéáóýíäåóçò ðïëëþí óõììåôå÷üíôùí. Ç ðñüóâáóç ôùí óõììåôå÷üíôùí ãßíåôáé óõíÞèùò ìå Ç/Õ. Ùóôüóï, õðÜñ÷åé êáé ç äõíáôüôçôá ðñüóâáóçò ìÝóù ôçëåöþíïõ (PSTN dial-in) êáé ìÝóù óõóôçìÜôùí
ÄéÜãñáììá 1: H äïìÞ ôùí Virtual Meeting Rooms ìÝóá óå ìßá Cloud MCU (Multipoint Control Unit) ìå ÷ùñçôéêüôçôá 100 óõììåôå÷üíôùí
Meeting Room
Éäåáôüò ÷þñïò óõíÜíôçóçò ìåôáîý ðïëëþí óõììåôå÷üíôùí
VMR
Virtual Meeting Room - Ýíáò Üëëïò üñïò ãéá ôï Meeting Room
Passcode
Êùäéêüò ðïõ åðéôñÝðåé ðñüóâáóç óå óýóêåøç
åíüò óçìåßïõ ðïõ ðñáãìáôïðïéåßôáé ìéá éäåáôÞ
Conference
Ìßá æùíôáíÞ óýóêåøç
ãßá ïíïìáôïëïãßáò Þ áñéèìïäüôçóçò ãéá íá
Conference ID
Ç ôáõôüôçôá ìßáò æùíôáíÞò óýóêåøçò
îå÷ùñßæïíôáé äéáöïñåôéêÜ Meeting Rooms ðïõ
SPRING 2022
Conference ID vs Passcode Ç Ýííïéá ôïõ éäåáôïý Meeting Room, äçëáäÞ óýóêåøç, ðñïöáíþò áðáéôåß êáé ôçí äçìéïõñ-
áíÞêïõí óå äéáöïñåôéêïýò éäéïêôÞôåò. COMMUNICATION SOLUTIONS
37
Video Conference
Åäþ åìöáíßæåôáé ç Ýííïéá ôïõ Meeting Room
äéáäéêôýïõ Þ Üëëùí ôïðéêþí äéêôýùí, åíþ ðá-
Number.
ëáéüôåñá áöïñïýóå êëÞóåéò ìüíï ìÝóù PSTN.
ÓõíÞèùò äßíïíôáé ìïíáäéêïß áñéèìïß óôá äéÜöï-
×ñçóéìïðïéþíôáò êáé ðÜëé ôï ðáñÜäåéãìá :
ñá Meeting Rooms, þóôå íá ðñïóäéïñßæåôáé ôï
PSTN call: +30 210 1234567 Meeting Room
êÜèå Ýíá. ÕðÜñ÷åé êáé ç äõíáôüôçôá íá Ý÷ïõí
2350700
ïíüìáôá, üìùò ïé áñéèìïß ðñïôéìïýíôáé äéüôé å-
Ðáñáôçñåßôáé üôé ôá äýï áðáñáßôçôá óôïé÷åßá
îõðçñåôïýí üôáí êÜðïéïé óõììåôÝ÷ïíôåò èÝ-
ãéá ôç óýíäåóç åßíáé ï áñéèìüò êëÞóçò êáé ôï
ëïõí íá óõíäåèïýí ìÝóù áðëÞò ôçëåöùíéêÞò
íïýìåñï ôïõ äùìáôßïõ.
êëÞóçò. Ãéá ðáñÜäåéãìá, áí ôï Meeting Room Number
Passcodes
åßíáé 2350700 ôüôå ï áñéèìüò ðïõ èá ðñÝðåé íá
Ôï Passcode åßíáé êùäéêüò ðïõ áöïñÜ óõóêÝ-
åéóÜãåé Ýíáò ôçëåöùíéêüò óõììåôÝ÷ùí ìå
øåéò. H Ýííïéá "Passcode" áöïñÜ êùäéêü êáé
DTMF åßíáé 2350700.
ü÷é êÜðïéï íïýìåñï ðïõ ìðïñåß íá äçìïóé-
Ôá ðëÞñç óôïé÷åßá ðñüóâáóçò áõôïý ôïõ
åýåôáé. Ôá passcodes äéáêñßíïíôáé óå Host
Meeting Room èá åßíáé:
Passcode, Participant Passcode, Guest
Meeting Room Number: 2350700
Passcode.
Connection URL: https://domain.com/ meetings/2350700 PSTN call: +30 210 1234567 Meeting Room 2350700. Conference ID / Meeting ID To Conference ID öáéíïìåíéêÜ åßíáé ôï ßäéï ìå
Ðñüóâáóç êáé Êùäéêïß Host Passcode
O Êùäéêüò ôïõ éäéïêôÞôç åíüò Meeting Room
Participant Passcode
O Êùäéêüò ôùí óõììåôå÷üíôùí óå ìßá óýóêåøç
Guest Passcode
Ï Êùäéêüò åíüò êáëåóìÝíïõ ìå ìåéùìÝíåò äõíáôüôçôåò
PIN
Ï ðñïóùðéêüò êùäéêüò åíüò óõììåôÝ÷ïíôá ãéá ìåãáëýôåñç áóöÜëåéá
ôï Meeting Room Number, êáé ìðïñåß óå ìåñéêÝò õðçñåóßåò íá ÷ñçóéìïðïéåßôáé áíôß ãéá ôïí üñï Meeting Room. Ùóôüóï, êáíïíéêÜ, áíáöÝñåôáé óå ìßá æùíôáíÞ óýóêåøç. Åêôüò áðü ôá
Host & Host passcode
áðïèçêåõìÝíá Meeting Rooms, óå êÜðïéåò õ-
Ï Host åßíáé ï éäéïêôÞôçò åíüò Virtual Meeting
ðçñåóßåò ìðïñïýí íá äçìéïõñãïýíôáé æùíôáíÝò óõóêÝøåéò ìå ôç ìïñöÞ "Ad-Hoc", äçëáäÞ ìç ðñïãñáììáôéóìÝíåò /Üìåóåò áðü äéá÷åéñéóôÞ Þ áðü ÷ñÞóôç Host. ÁõôÝò ïé óõóêÝøåéò äåí âñßóêïíôáé óôïí êáôÜëïãï ôùí meeting rooms êáé ðñïóäéïñßæïíôáé áðü ôï Conference ID Þ áëëéþò Meeting ID.
Room. Ìðïñåß íá ïñãáíþóåé óõóêÝøåéò óå áõôü ôï éäåáôü äùìÜôéï êáé Ý÷åé üëåò ôéò äõíáôüôçôåò ðïõ áöïñïýí ôï äùìÜôéï, üðùò äõíáôüôçôåò êáôÜ ôçí äéåîáãùãÞ ôçò óýóêåøçò êáé äõíáôüôçôåò ðñïãñáììáôéóìïý, áëëáãÞò passcodes êáé Üëëùí äéá÷åéñéóôéêþí ñõèìßóåùí. Ôï Host Passcode åßíáé Ýíáò êùäéêüò ðïõ ðáñÝ÷åôáé ìüíï óôïí Host.
38
ÓõíäÝóåéò Audio Conference
Ï Host äåí ðñÝðåé íá ìïéñáóôåß ôïí êùäéêü ôïõ
Ç õðçñåóßá Audio Conference åßíáé ç äéáóýíäå-
ìå êáíÝíáí. Ïé óõììåôÝ÷ïíôåò óôç óýóêåøç
óç ðïëëþí óõììåôå÷üíôùí óå ç÷çôéêÞ óýóêå-
äåí èá ðñÝðåé íá ôïí îÝñïõí. Ï Host èá óôåßëåé
øç. ÓÞìåñá ç Ýííïéá ôïõ Audio Conference á-
óå áõôïýò Ýíáí Üëëï êùäéêü, ôïí Participant
öïñÜ ôçí óýíäåóç åßôå ìÝóù PSTN åßôå ìÝóù
Passcode, ðïõ åîçãåßôáé ðáñáêÜôù.
COMMUNICATION SOLUTIONS
SPRING 2022
Video Conference
Ï Host åßíáé Ýíáò õðÜëëçëïò ôçò åôáéñåßáò ðïõ
óôçìá ùò ïñãáíùôÞò êáé åîáêïëïõèåß íá Ý÷åé
Ý÷åé äéêáßùìá äéïñãÜíùóçò óõíáíôÞóåùí. Ï
êÜðïéåò áõîçìÝíåò äõíáôüôçôåò.
êùäéêüò Host ôïõ åðéôñÝðåé íá óõíäÝåôáé óôç
Ï ðéï óõíçèéóìÝíïò ôñüðïò ÷ñÝùóçò ìéáò õðç-
óýóêåøç êáé íá Ý÷åé õøçëÝò äõíáôüôçôåò ïñ-
ñåóßáò åßíáé ìå ôïí áñéèìü Hosts ðïõ ðáñÝ÷åé.
ãÜíùóçò êáé äéá÷åßñéóçò ôçò óýóêåøçò.
Ãéá ðáñÜäåéãìá, Ýíáò ðåëÜôçò ìðïñåß íá ðñï-
ÊáôÜ ôç äéïñãÜíùóç óýóêåøçò, ï Host Ý÷åé äõ-
ìçèåõôåß 100 Meeting Rooms áðü Ýíáí ðÜñï÷ï
íáôüôçôåò üðùò:
õðçñåóßáò ôçëåäéÜóêåøçò. Ï ðåëÜôçò èá ëÜâåé
l Ðñïãñáììáôéóìü óýóêåøçò óôï çìåñïëü-
100 êùäéêïýò "Host", åö' üóïí ç õðçñåóßá åßíáé
ãéï
ìüíï Audio Conference. Áí ç õðçñåóßá åßíáé ìå
l ÁëëáãÞ ÷áñáêôçñéóôéêþí áóöáëåßáò óý-
Audio êáé Video, ôüôå ï ðåëÜôçò èá ëÜâåé 100
óêåøçò (÷ñÞóç meeting passcode, áëëáãÞ
links ãéá ôá áíôßóôïé÷á Meeting Rooms, êÜèå
passcode, ñõèìßóåéò ðñüóâáóçò ÷ñçóôþí
Ýíá áðü ôá ïðïßá èá Ý÷åé ìïíáäéêü áñéèìü. Ïé
ìÝóù lobby, ðñüóâáóç ìå áíáìïíÞ êëð)
éäéïêôÞôåò ôùí äùìáôßùí (Hosts) èá Ý÷ïõí ï
l ÁëëáãÞ ÷áñáêôçñéóôéêþí ðïéüôçôáò êáé åì-
öÜíéóçò (Ðïéüôçôá åéêüíáò, video layouts êëð). ÊáôÜ ôç äéÜñêåéá óõóêÝøåùí, ï Host Ý÷åé äéêáéþìáôá üðùò: l Íá äéá÷åéñßæåôáé ôçí åßóïäï ôùí óõììåôå÷ü-
íôùí ðïõ âñßóêïíôáé óå áíáìïíÞ l Óßãáóç ÷ñÞóôç (Mute Participant) l Óßãáóç üëùí ôùí ÷ñçóôþí (Mute All Parti-
cipants) l Íá áðïóõíäÝóåé ÷ñÞóôåò (Disconnect / Kick
/ Expel Participant) l Íá äþóåé óå ÷ñÞóôç ôç äõíáôüôçôá ðáñïõ-
óßáóçò (Make Presenter) l Íá äéá÷åéñßæåôáé ôá video layouts.
Èá ðñÝðåé íá ôïíéóôåß üìùò üôé ç Ýííïéá ôïõ Host Passcode åßíáé ðåñéóóüôåñï ÷ñÞóéìç óôï audio conference. Ãéá óõóêÝøåéò ôçëåäéÜóêå-
êáèÝíáò ôï äéêü ôïõ username & password. ÁõôÜ ìðïñåß íá åßíáé Ýôïéìá áðü ôçí õðçñåóßá Þ åíáëëáêôéêÜ ç õðçñåóßá íá äþóåé ôç äõíáôüôçôá äéá÷åéñéóôÞ óôïí ðåëÜôç, þóôå ï ðåëÜôçò íá åéóÜãåé ôá óôïé÷åßá ôùí hosts. Íá óçìåéùèåß üôé êÜèå Ýíá áðü ôá 100 Meeting Rooms Ý÷åé Ýíáí áñéèìü óõììåôå÷üíôùí ðïõ õðïóôçñßæåé, ð.÷. ìðïñåß íá õðïóôçñßæåé 50 participants. Áõôü óçìáßíåé üôé èá ðñÝðåé ïé 100 hosts íá ìðïñïýí íá åíåñãïðïéÞóïõí üëïé ôç óýóêåøÞ ôïõò ôáõôü÷ñïíá, ìå 50 óõììåôÝ÷ïíôåò ï êáèÝíáò. ÓõíïëéêÜ äçëáäÞ èá ðñÝðåé íá ìðïñïýí íá óõóêåöèïýí ôáõôü÷ñïíá 5000 óõììåôÝ÷ïíôåò! ÓÞìåñá ôá ìåãÝèç ÷ùñçôéêüôçôáò óõóêÝøåùí Ý÷ïõí áõîçèåß óçìáíôéêÜ. ÕðÜñ÷ïõí õðçñåóßåò ðïõ õðïóôçñßæïõí 300, 500 Þ êáé 1000 óõììåôÝ÷ïíôåò, åíþ ðïëëÝò öïñÝò êÜðïéïé ðÜñï÷ïé éó÷õñßæïíôáé üôé äåí Ý÷ïõí ìÝãéóôï áñéèìü,
øçò, ï Host óõíäÝåôáé óôï äùìÜôéü ôïõ ìÝóù
äçëáäÞ ìðïñïýí íá õðïóôçñßîïõí «áðåñéü-
Web Browser ìå ôïõò êùäéêïýò ôïõ, äçëáäÞ
ñéóôï áñéèìü óõììåôå÷üíôùí».
username & password êáé Ýôóé áíáãíùñßæåôáé
Ôá ìåãÝèç öáßíåôáé üôé ìåãÜëùóáí ëüãù ôçò
ùò ï éäéïêôÞôçò ôïõ Meeting Room ÷ùñßò íá
óôáäéáêÜ áõîáíüìåíçò æÞôçóçò ãéá õðçñåóßåò
÷ñåéáóôåß íá åéóÜãåé ôï Host Passcode.
ôçëåäéÜóêåøçò ôá ôåëåõôáßá ÷ñüíéá. Óßãïõñá
Óå áõôÞ ôçí ðåñßðôùóç ôï Host Passcode åßíáé
üìùò, óå áõôÞ ôçí êáôåýèõíóç Ýðáéîå åðéôá-
ðéï ÷ñÞóéìï üôáí ï Host ãéá ëüãïõò äõóêïëßáò
÷õíôéêü ñüëï ç ðáíäçìßá Covid-19 ç ïðïßá áý-
ðñüóâáóçò óõììåôÝ÷åé ìÝóù ôçëåöþíïõ. Ìå
îçóå áêüìá ðåñéóóüôåñï ôç æÞôçóç ãéá áðïìá-
ôï Host Passcode áíáãíùñßæåôáé áðü ôï óý-
êñõóìÝíåò óõóêÝøåéò.
SPRING 2022
COMMUNICATION SOLUTIONS
39
Video Conference
Participant & Participant Passcode (Meeting
ñüëïò áõôüò åßíáé êáôÜëëçëïò ãéá óõììåôÝ-
Passcode)
÷ïíôåò ðïõ äåí áíÞêïõí óôçí åôáéñåßá ðïõ Ý÷åé
Ï üñïò Participant áíáöÝñåôáé óôïõò óõììå-
ôç äéá÷åßñéóç ôïõ óõóôÞìáôïò êáé óõììåôÝ÷ïõí
ôÝ÷ïíôåò ìéáò ôçëåäéÜóêåøçò åêôüò ôïõ äéïñ-
ùò åîùôåñéêïß óõíåñãÜôåò óå êÜðïéá óýóêåøç.
ãáíùôÞ. Ï äéïñãáíùôÞò êáëåß ôá Üôïìá ðïõ
Åðßóçò, ìðïñåß áõôïß ïé óõììåôÝ÷ïíôåò íá óõì-
åðéèõìåß íá óõóêåöèïýí óôï äùìÜôéü ôïõ êáé
ìåôÝ÷ïõí åõêáéñéáêÜ Þ ìüíï ìßá öïñÜ óå óý-
ðáñÝ÷åé ôéò ïäçãßåò ðñüóâáóçò. ¼ôáí óõíäå-
óêåøç ÷ùñßò íá åßíáé ðéèáíü íá óõììåôÜó÷ïõí
èïýí, áõôÜ ôá Üôïìá áðïôåëïýí ôïõò "parti-
óôï ìÝëëïí.
cipants" ôçò óýóêåøçò.
Ãéá áõôÝò ôéò ðåñéðôþóåéò, ðïëëÝò õðçñåóßåò
To Participant Passcode (Meeting Passcode)
Ý÷ïõí ôïí ñüëï Guest ðïõ õðïäçëþíåé ìåéùìÝ-
äßíåôáé áðü ôïí Host óôïõò óõììåôÝ÷ïíôåò êá-
íåò äõíáôüôçôåò êáôÜ ôç óýóêåøç ð.÷. äåí
ôÜ ôçí äéïñãÜíùóç ìéáò óýóêåøçò. Êáé ðÜëé
ìðïñåß íá ðáñïõóéÜóåé, äåí ìðïñåß íá áíåâÜ-
éó÷ýåé ôï üôé åßíáé ðéï óõíçèéóìÝíï íá äßíåôáé
óåé áñ÷åßá, äåí ìðïñåß íá óõììåôÜó÷åé óôï
óå óõóêÝøåéò audio. Ãéá óõóêÝøåéò Video, ïé
Chat (åêôüò áí äïèåß ç äõíáôüôçôá áðü Ýíáí
Participants ëáìâÜíïõí óõíÞèùò Ýíá URL êáé ï
Host). Óå êÜðïéåò õðçñåóßåò ï Guest äåí ìðï-
Ýëåã÷ïò ðñüóâáóÞò ôïõò ãßíåôáé åßôå áðü ôïí
ñåß íá äåé ôá ïíüìáôá êáé óôïé÷åßá ôùí Üëëùí
Host åßôå èåùñïýíôáé áõôüìáôá Participants
óõììåôå÷üíôùí êáé ðïëëÝò öïñÝò äåí ìðïñåß
åö' üóïí äåí Ý÷ïõí êÜíåé Login ìå ÷ñÞóç Host
íá äåßîåé ôï video ôçò webcam áí äåí åðéôñáðåß
Passcode / Host Login.
áðü ôïí Host.
To Participant Passcode åßíáé ÷ñÞóéìï óôçí ðå-
Ùóôüóï, Ýíá óçìáíôéêü ðïõ ðñÝðåé íá óçìåéù-
ñßðôùóç ôïõ Personal Room, ðïõ áíáëýåôáé
èåß ãéá ôïí ñüëï ôïõ Guest åßíáé üôé âáóéêÞ ôïõ
ðáñáêÜôù. ÓõíÞèùò áíáöÝñåôáé ùò Meeting
äéáöïñÜ áðü Ýíáí Conference Participant èá
Passcode óå áõôÞ ôçí ðåñßðôùóç.
ðñÝðåé íá åßíáé ôï üôé ï Guest äåí åßíáé åããå-
To Participant Passcode åßíáé ôï ßäéï ãéá üëïõò
ãñáììÝíïò ÷ñÞóôçò.
ôïõò Participants.
Ï Guest óõ÷íÜ óõã÷Ýåôáé ìå ôïí Participant.
Ïé äéáöïñÝò ôùí üñùí Host, Participant êáé
ÕðÜñ÷ïõí õðçñåóßåò ðïõ ÷ñçóéìïðïéïýí
Guest Ý÷ïõí íá êÜíïõí ìå ôï åðßðåäï ðñü-
ïñïëïãßá Host/Guest, äçëáäÞ ï Guest åßíáé ï
óâáóçò êáé áóöÜëåéáò ðïõ Ý÷ïõí ïé áíôßóôïé÷ïé
óõíçèéóìÝíïò óõììåôÝ÷ùí. ÊáôÜ ôç äéåîáãùãÞ
÷ñÞóôåò. Ï üñïò "Participant" õðïíïåß ôïí áðëü
ôçëåöùíéêþí óõóêÝøåùí ìå Audio-Only, óõ÷íÜ
óõììåôÝ÷ïíôá óå ìéá óýóêåøç, ï ïðïßïò Ý÷åé
áðïäßäåôáé ç ïñïëïãßá Host / Guest.
ëÜâåé ðñüóêëçóç áðü êÜðïéïí Host. Ï Parti-
ÓÞìåñá, ïé õðçñåóßåò ðïõ õðïóôçñßæïõí ìüíï
cipant Ý÷åé ôéò âáóéêÝò äõíáôüôçôåò ðïõ ôïõ
Audio Conference, åßíáé åëÜ÷éóôåò êáé èåùñïý-
åðéôñÝðïõí íá óõììåôÜó÷åé óôç óýóêåøç.
íôáé îåðåñáóìÝíåò. ¼ëïé ïé ÷ñÞóôåò õðçñå-
Ìðïñåß íá ìéëÞóåé, íá åìöáíßæåôáé óôçí ïèüíç
óéþí ôçëåäéÜóêåøçò èá ðñÝðåé íá Ý÷ïõí ôç
(íá êÜíåé äçëáäÞ "publish" ôï video ôçò êÜ-
äõíáôüôçôá íá óõóêåöèïýí åßôå ìå åéêüíá åßôå
ìåñÜò ôïõ) êáé áíÜëïãá ôéò ñõèìßóåéò ìðïñåß
ìüíï ìå Þ÷ï. Óõíåðþò åßíáé êáëýôåñï íá ÷ñçóé-
íá êÜíåé ðáñïõóßáóç.
ìïðïéåßôáé ç ïñïëïãßá Host / Participant, þóôå íá åßíáé îåêÜèáñïé ïé ñüëïé áíåîáñôÞôùò ôïõ
Guest & Guest Passcode
ôñüðïõ ðñüóâáóçò.
Ï Guest åßíáé Ýíáò åîùôåñéêüò óõììåôÝ÷ùí
40
ðïõ êáíïíéêÜ äåí Ý÷åé ôéò ßäéåò äõíáôüôçôåò ìå
PIN
ôïí participant, áëëÜ êáôÜ ðïëý ìåéùìÝíåò. Ï
H Ýííïéá ôïõ PIN åßíáé ðñïóùðéêÞ. PIN óçìáßíåé
COMMUNICATION SOLUTIONS
SPRING 2022
Video Conference
Personal Identification Number êáé äåí ðñÝðåé
ñåóßåò. Äßíåé ôç äõíáôüôçôá äéåîáãùãÞò óõóêÝ-
íá óõã÷Ýåôáé ìå ôçí Ýííïéá ôïõ Passcode. Ôï
øåùí ìå áõóôçñÜ ïíïìáóôéêÞ ëßóôá êáëåóìÝ-
PIN óõíåéóöÝñåé óçìáíôéêÜ óôçí áóöÜëåéá ôùí
íùí ÷ùñßò íá áöÞíåé ðåñéèþñéá íá ìïéñáóôåß
óõóêÝøåùí êáèþò åßíáé Ýíáò ðñïóùðéêüò êù-
êÜðïéïò ôï Passcode ìå êÜðïéïí Üëëïí.
äéêüò. Ïé óõììåôÝ÷ïíôåò óå ìéá óýóêåøç ðïõ áðáéôåß PIN, Ý÷ïõí ï êáèÝíáò äéáöïñåôéêü êùäéêü PIN óå áíôßèåóç ìå Ýíá Participant Passcode ðïõ åßíáé ôï ßäéï ãéá üëïõò. Áõôü åêôüò áðü ôçí óçìáíôéêÞ áýîçóç ôçò áóöÜëåéáò äßíåé êáé ìßá Üëëç äéÜóôáóç óôç óýóêåøç, áõôÞ ôçò äõíáôüôçôáò ôáõôïðïßçóçò ôïõ óõììåôÝ÷ïíôá (üðùò ðñïóäéïñßæåé êáé ç ëÝîç Identification óôï PIN), ðïõ áíáëýåôáé ðá-
Åßäç óõóêÝøåùí Scheduled Meeting
ÐñïãñáììáôéóìÝíç óýóêåøç ãéá óõãêåêñéìÝíç þñá êáé çìÝñá
Meet-Me
Ìüíéìï äùìÜôéï, ðÜíôá äéáèÝóéìï, ìå óôáèåñü URL ðñüóâáóçò
One-Time Passcode
Passcode óýóêåøçò ìßáò ÷ñÞóçò
ñáêÜôù.
ÐñïãñáììáôéóìÝíåò óõóêÝøåéò óå Meeting
¼óïí áöïñÜ ôç ÷ñÞóç PIN óå óõóêÝøåéò, íá
Rooms (Scheduled Meetings)
óçìåéùèåß üôé ðïëëÝò õðçñåóßåò êáé êáôáóêåõ-
Ç ðéï óõíçèéóìÝíç ìïñöÞ óýóêåøçò åßíáé ç
áóôÝò ÷ñçóéìïðïéïýí ôçí ïñïëïãßá PIN ìå åóöáëìÝíï ôñüðï. Ï êùäéêüò PIN åßíáé ðñïóùðéêüò êáé êáô' åðÝêôáóç ç Ýííïéåò "Meeting PIN", "Conference PIN" äåí Ý÷ïõí íüçìá, áöïý áõôïß ïé êùäéêïß áðïôåëïýí ïõóéáóôéêÜ ôï Participant Passcode.
ðñïãñáììáôéóìÝíç óýóêåøç. ÁõôÞ äçìéïõñãåßôáé áðü ôïí Host. Ùò éäéïêôÞôçò åíüò Meeting Room, o Host ìðïñåß íá äçìéïõñãåß äéáöïñåôéêÝò óõóêÝøåéò óå äéáöïñåôéêÝò ìÝñåò êáé þñåò. Ãéá ôç äçìéïõñãßá ôùí óõóêÝøåùí ï Host åðé-
Identity-Based Conferencing
ëÝãåé çìåñïìçíßá êáé þñá êáé óõìðëçñþíåé
Ãéá ôçí ôáõôïðïßçóç ôïõ óõììåôÝ÷ïíôá ìÝóù
êÜðïéá óôïé÷åßá, üðùò ð.÷. ôïí ôßôëï ôçò óýóêå-
PIN: Ï êùäéêüò PIN äßíåôáé ìüíï óå åããåãñáì-
øçò, ÷áñáêôçñéóôéêÜ ðñüóâáóçò üðùò Lobby,
ìÝíïõò ÷ñÞóôåò êáé ï êÜèå ÷ñÞóôçò Ý÷åé ôïí
÷ñÞóç Meeting Passcode. ÌåôÜ ôç äçìéïõñãßá
äéêü ôïõ ðñïóùðéêü êùäéêü ðïõ åßíáé ðÜíôá ï ßäéïò. ¼ôáí ï ÷ñÞóôçò åéóÜãåé ôï PIN ôçí þñá ðïõ ìðáßíåé óå ìéá óýóêåøç, ôï óýóôçìá ìðïñåß íá ðñïóäéïñßóåé ôï ÷ñÞóôç ìïíáäéêÜ. ÕðÜñ÷åé Ýôóé ðïëý ìåãáëýôåñç áóöÜëåéá, êáèþò ïé ÷ñÞóôåò åßíáé ðñï-åããåãñáììÝíïé. ¼ôáí ïé ÷ñÞóôåò ìðáßíïõí óå Ýíá conference call ÷ùñßò PIN, áëëÜ ìå Meeting Passcode (Þ áêüìá êáé ÷ùñßò passcode), ôüôå åßíáé óôç äéáêñéôéêÞ ôïõò åõ÷Ýñåéá íá âÜëïõí ôï üíïìÜ ôïõò üôáí ôïõò æçôçèåß. ¸íáò êáêüâïõëïò ÷ñÞóôçò ìðïñåß ðïëý áðëÜ íá âÜëåé Üëëï üíïìá. Ç ÷ñÞóç PIN êáé ç ôáõôïðïßçóç ôïõ ÷ñÞóôç áðü áõôü ïíïìÜæåôáé Identity Conferencing. Åßíáé ó÷åôéêÜ óðÜíéï êáé ðñï÷ùñçìÝíï ÷áñáêôçñéóôéêü ðïõ âñßóêåôáé óå ðéï åîåëéãìÝíåò õðçSPRING 2022
Åéêüíá 1: ÐáñÜäåéãìá öüñìáò ðñïãñáììáôéóìïý óõíÜíôçóçò COMMUNICATION SOLUTIONS
41
Video Conference
êáé áðïèÞêåõóç ôçò óýóêåøçò, ï Host ìðïñåß
Óôçí ðåñßðôùóç audio conference, ï óõììåôÝ-
íá ðñïóêáëÝóåé ôïõò äéÜöïñïõò óõììåôÝ÷ï-
÷ùí èá ðñÝðåé íá êáëÝóåé ôï ó÷åôéêü íïýìåñï
íôåò. Áõôü ãßíåôáé óôÝëíïíôÜò ôïõò ôï URL ôçò
êëÞóçò êáé ìåôÜ áðü ôï ç÷çôéêü ìÞíõìá ðïõ
ðñïãñáììáôéóìÝíçò óýóêåøçò.
ôïí êáëåß íá åéóÜãåé êùäéêü, íá âÜëåé ôïí áñéèìü 1234567.
Personal Room (Meet-Me) Ôï Personal Room Þ Meet-Me åßíáé ìéá Ýêöñáóç ðïõ ÷ñçóéìïðïéåßôáé áðü ðïëëïýò êáôáóêåõáóôÝò ãéá éäåáôÜ äùìÜôéá óõóêÝøåùí ôá ïðïßá Ý÷ïõí óôáèåñÜ óôïé÷åßá ðñüóâáóçò. Ôï Personal Room Ý÷åé ðÜíôá ôï ßäéï URL êáé åßíáé ðÜíôá äéáèÝóéìï ãéá óõóêÝøåéò, óå áíôßèåóç ìå ôéò ðñïãñáììáôéóìÝíåò óõóêÝøåéò (Scheduled Meetings) ïé ïðïßåò ÷ñçóéìïðïéïýí One-Time Passcode êáé åßíáé äéáèÝóéìåò ìüíï êáôÜ ôçí þñá êáé çìÝñá ðïõ Ý÷ïõí ðñïãñáììáôéóôåß. Áí ç ðñüóâáóç åßíáé ìÝóù Web Browser, ôüôå
ÄéÜãñáììá 3. audio connection ìå áñéèìü êëÞóçò êáé ôçëÝöùíï
ôï URL ðñüóâáóçò ìðïñåß íá Ý÷åé ôçí åîÞò ìïñöÞ: https://domain.com/meetings/1234567 Óå áõôü ôï URL Ý÷ïõìå ôï ðñüèåìá ìÝ÷ñé êáé ôç ëÝîç meetings ðïõ ôï ðåñéÝ÷ïõí üëá ôá éäåáôÜ äùìÜôéá, êáé ôïí áñéèìü 1234567 ðïõ ðñïóäéïñßæåé ôï óõãêåêñéìÝíï äùìÜôéï. Ïé óõììåôÝ÷ïíôåò ìðïñïýí íá óõíäÝïíôáé óå áõôü ôï äùìÜôéï ÷ñçóéìïðïéþíôáò ðÜíôá ôï ßäéï URL. Ç äéåýèõíóç ôïõ äùìáôßïõ äåí áëëÜæåé.
Ôï Personal Room Ý÷åé ôï ðëåïíÝêôçìá üôé åßíáé Ýíá óôáèåñü óçìåßï óýíäåóçò ìå ôï ßäéï URL. Äåí ÷ñåéÜæåôáé íá äßíïíôáé óõíÝ÷åéá óôïõò óõììåôÝ÷ïíôåò äéáöïñåôéêÜ óôïé÷åßá óýíäåóçò. Ìðïñïýí íá ôá Ý÷ïõí áðïèçêåõìÝíá ð.÷. óå Ýíá bookmark óôïí Web Browser êáé íá óõíäÝïíôáé üðïôå ÷ñåéÜæåôáé. Óõíåðþò áõôüò ï ôñüðïò óýóêåøçò åßíáé êáôÜëëçëïò ãéá óõ÷íÝò êáé åðáíáëáìâáíüìåíåò óõóêÝøåéò üðïõ ïé óõììåôÝ÷ïíôåò åßíáé ãíùóôïß ð.÷. óôåíïß óõíÜäåëöïé êáé Ýôóé äåí óõíôñÝ÷åé êßíäõíïò íá ãíùñßæåé êÜðïéïò ìç åîïõóéïäïôçìÝíïò ôá óôïé÷åßá óýíäåóçò. ¼ôáí ïé óõììåôÝ÷ïíôåò äåí åßíáé óôï óôåíü ðåñéâÜëëïí, Þ üôáí äåí åßíáé óõ÷íÝò ïé óõíáíôÞóåéò, äåí åßíáé ç êáëýôåñç åðéëïãÞ íá äßíïíôáé ôá óôïé÷åßá ôïõ ìüíéìïõ Personal Room. ÊÜðïéïò ìðïñåß êáôÜ ëÜèïò Þ óêüðéìá íá óõíäåèåß óå óýóêåøç åíþ äåí åßíáé åðéèõìçôü. Åðßóçò, êÜðïéïò ìðïñåß íá ÷ñçóéìïðïéÞóåé ôï óýóôçìá ôçëåäéÜóêåøçò ãéá ôéò äéêÝò ôïõ óõíá-
ÄéÜãñáììá 2. video connection ìå URLs êáé web browsers ðïõ óõíäÝïíôáé óå êåíôñéêü óçìåßï 42
COMMUNICATION SOLUTIONS
íôÞóåéò, äùñåÜí! ÅðéðëÝïí áóöÜëåéá ãéá ôéò ðáñáðÜíù ðåñéðôþóåéò ìðïñåß íá äïèåß äçìéïõñãþíôáò Ýíá SPRING 2022
Video Conference
Ìeeting Passcode (Participant Passcode). Óå áõôÞ ôçí ðåñßðôùóç, ïé óõììåôÝ÷ïíôåò ãíùñßæïõí ôï URL ôçò óýíäåóçò, üìùò ðñÝðåé íá Ý÷ïõí êáé ôï meeting passcode. Åßíáé Ýíá óçìáíôéêü óôïé÷åßï ðïõ áõîÜíåé ôçí áóöÜëåéá êáé ëýíåé ôï ðñüâëçìá ôçò åýêïëçò óýíäåóçò óôï Meet-Me room áðü ïðïéïíäÞðïôå. ¼ìùò áõôü óõíåðÜãåôáé êáé áýîçóç ôçò ðïëõðëïêüôçôáò óýíäåóçò êáèþò ìåñéêïß ÷ñÞóôåò äõóêïëåýïíôáé üôáí Ý÷ïõí íá êÜíïõí ìå ðïëëÜ äéáöïñåôéêÜ links êáé passcodes.
ÄéÜãñáììá 5: Meeting Room, ðñïãñáììáôéóìÝíá Meetings êáé Personal Room (Meet-Me)
éäéïêôÞôçò ôïõ Meet-Me room. Åßíáé åðéèõìçôü ôá óõóôÞìáôá ôçëåäéÜóêåøçò íá äßíïõí ôç äõíáôüôçôá óôïí ÷ñÞóôç íá áëëÜæåé ìüíïò ôïõ ôï password ÷ùñßò ôçí ðáñÝìâáóç äéá÷åéñéóôÞ. Ðéï êáôÜëëçëç ãéá åõêáéñéáêÝò óõíáíôÞóåéò åßíáé ç õðçñåóßá ôïõ One-Time Passcode ç ïðïßá ðåñéãñÜöåôáé ðáñáêÜôù. Åðßóçò, ëýóåéò óå êÜðïéá áðü áõôÜ ôá ðñïâëÞìáôá äßíåé êáé ôï ÷áñáêôçñéóôéêü ôïõ Lobby. One-Time Passcode To One-Time Passcode åßíáé ç äõíáôüôçôá åíüò óõóôÞìáôïò íá ðáñÜãåé êùäéêïýò ðñüóâáóçò ðïõ éó÷ýïõí ìüíï ãéá Ýíá óõãêåêñéìÝíï conference call êáé ðáýïõí íá éó÷ýïõí ìåôÜ ôçí ÄéÜãñáììá 4: Óýíäåóç óå Meet-Me room ìå Meeting Passcode: Participant -> URL > Meeting Passcode Request -> óýíäåóç. (Flow Chart)
Óå áõôÞ ôçí ðåñßðôùóç, ï participant ëáìâÜíåé ôá åîÞò óôïé÷åßá: Meeting URL: https://domain.com/meetings/ 6672400
ëÞîç ôïõ. Ôï One-Time Passcode åßíáé óçìáíôéêü ãéá ôçí áóöÜëåéá ôùí êëÞóåùí êáèþò áðïêëåßåé ôç äõíáôüôçôá åíüò áôüìïõ íá óõíäåèåß óå ìç åîïõóéïäïôçìÝíç êëÞóç, åßôå êáôÜ ëÜèïò, åßôå óêüðéìá. Ïé óõììåôÝ÷ïíôåò óôçí êëÞóç ìå One-Time Passcode äåí ìðïñïýí íá óõíäåèïýí óôçí ßäéá êëÞóç ôçí åðüìåíç çìÝñá Þ ìåôÜ áðü ìßá åâäï-
Meeting Passcode: 452234
ìÜäá äéüôé áõôÞ ç êëÞóç Þôáí ìïíáäéêÞ. Åßíáé
Ìå ôç ÷ñÞóç ôïõ Meeting Passcode, äåí ìðï-
óõíåðþò êáôÜëëçëï ãéá ðåñéðôþóåéò üðïõ äåí
ñåß êÜðïéïò ðïõ ãíùñßæåé ôo Meeting URL áðü
åßíáé åðéèõìçôü ïé óõììåôÝ÷ïíôåò íá Ý÷ïõí ôá
ðñïçãïýìåíç óýóêåøç íá óõíäåèåß óå åðüìå-
óôïé÷åßá óýíäåóçò ìüíéìá, üðùò óõìâáßíåé ìå
íç óýóêåøç. Áõôü öõóéêÜ áí ôï passcode Ý÷åé
åõêáéñéáêÝò óõíáíôÞóåéò Þ óõíáíôÞóåéò ìå å-
áëëá÷èåß.
îùôåñéêïýò óõíåñãÜôåò.
Ôï Meeting Passcode èá ðñÝðåé íá áëëÜæåé óå
Óå áíôßóôïé÷ç ðåñßðôùóç, áí ðñüêåéôáé ãéá
êÜèå meeting. Áõôü èá ðñÝðåé íá ôï öñïíôßæåé ï
Personal Room, o óõììåôÝ÷ùí ìðïñåß íá óõí-
SPRING 2022
COMMUNICATION SOLUTIONS
43
Video Conference
äåèåß êáé ðÜëé ôçí åðüìåíç ìÝñá. Ç áóöÜëåéá ôïõ Personal Room ïõóéáóôéêÜ åîáñôÜôáé áðü ôïí áí õðÜñ÷åé åðéðëÝïí meeting passcode, Þ Üëëïò ôñüðïò åëÝã÷ïõ ôùí óõììåôå÷üíôùí. Ôï One-Time Passcode óõíÞèùò ÷ñçóéìïðïéåßôáé óå ðñïãñáììáôéóìÝíåò óõóêÝøåéò. ¼ìùò åßíáé äõíáôüí êÜðïéïò Host íá äçìéïõñãÞóåé ìßá óýóêåøç Üìåóá, êáé íá åðéëÝîåé ãéá áõôÞí ôï ÷áñáêôçñéóôéêü One-Time Passcode, áíôß íá ÷ñçóéìïðïéÞóåé ôï Personal Room. Ôñüðïé Ðñüóâáóçò (Join Options) Lobby
Éäåáôüò ÷þñïò áíáìïíÞò
Host-Activated Meeting
Åíåñãïðïßçóç óýóêåøçò
Let in On-Hold Participants
Ï Host åðéôñÝðåé ôçí åßóïäï óå óõììåôÝ÷ïíôåò ðïõ âñßóêïíôáé óôçí áíáìïíÞ
ÁíáìïíÞ
ÄéÜãñáììá 6: Participants êáé áíáìïíÞ óôï Lobby
íá óõíäåèåß ï Host. ¼ôáí óõíäåèåß ï Host, üëïé óõíäÝïíôáé áõôüìáôá åêåßíç ôç óôéãìÞ. Ï Host äåí ìðïñåß íá êáèõóôåñÞóåé ôç óýíäåóÞ ôïõò. Ôï Lobby Ý÷åé ìéá åðéðëÝïí éäéüôçôá ðïõ ôï äéá÷ùñßæåé áðü ôçí ñýèìéóç ðïõ åíåñãïðïéåß ôç óýóêåøç ìå ôç óýíäåóç ôïõ Host. ÁõôÞ åßíáé ç äõíáôüôçôá ôïõ Host íá óõíäåèåß óôç óýóêåøç ÷ùñßò íá óõíäåèïýí áõôüìáôá ïé õðüëïéðïé ðñïóêåêëçìÝíïé. Ï ëüãïò ãéá áõôü åßíáé üôé ï
Ç áíáìïíÞ åßíáé ìßá êáôÜóôáóç óôçí ïðïßá âñß-
Host åðéèõìåß ðïëëÝò öïñÝò íá åëÝãîåé ôç
óêïíôáé ïé óõììåôÝ÷ïíôåò ðñéí óõíäåèïýí. Áõ-
óýóêåøç, íá äïêéìÜóåé ôçí ðáñïõóßáóç Þ íá
ôü óõìâáßíåé üôáí êÜðïéïé óõììåôÝ÷ïíôåò óõí-
êÜíåé Üëëåò ðáñüìïéåò äéá÷åéñéóôéêÝò åñãá-
äÝïíôáé ëßãá ëåðôÜ ðñéí áðü ôçí þñá Ýíáñîçò.
óßåò, ÷ùñßò íá âëÝðïõí Þ íá áêïýí ïé óõììå-
Åðßóçò áí óõíäåèïýí ôçí þñá ôçò óýóêåøçò Þ
ôÝ÷ïíôåò.
áñãüôåñá, ìðïñåß áíÜëïãá ìå ôéò ñõèìßóåéò íá
¼ôáí ï Host áðïöáóßóåé üôé åßíáé üëá Ýôïéìá,
ðåñéìÝíïõí íá ôïõò äå÷ôåß ï Host.
ôüôå ìðïñåß íá óõíäÝóåé ôïõò óõììåôÝ÷ïíôåò óôç æùíôáíÞ óýóêåøç. Åðßóçò, ìðïñåß ï Host
Lobby
íá óõíäÝåé Ýíáí Ýíáí / åðéëåêôéêÜ ôïõò óõììå-
ÐåñéãñÜöåé ôçí äõíáôüôçôá óõãêÝíôñùóçò ôùí
ôÝ÷ïíôåò.
óõììåôå÷üíôùí óå Ýíáí éäåáôü ÷þñï "Lobby"
44
ðñéí ôçí Ýíáñîç ôçò óýóêåøçò. Åðßóçò, áí o
Åðßëïãïò 1ïõ ìÝñïõò êáé óõìðåñÜóìáôá
Host åßíáé áõôüò ðïõ åíåñãïðïéåß ìå ôçí åßóïäü
Óôï 1ï ìÝñïò áíáëýïíôáé ÷áñáêôçñéóôéêÜ óõ-
ôïõ ôç óýóêåøç, êáé ðÜëé ïé óõììåôÝ÷ïíôåò ðïõ
óêÝøåùí ðïõ áöïñïýí êõñßùò ôïõò äéÜöïñïõò
ðåñéìÝíïõí ãéá 2-3 ëåðôÜ ìåôÜ ôçí þñá Ýíáñ-
ôñüðïõò ðñüóâáóçò, ôïõò êùäéêïýò êáé ôéò
îçò, èá ðñÝðåé íá âñßóêïíôáé óôï Lobby.
ìåèüäïõò áóöáëåßáò ãéá ôç äéáóýíäåóç ôùí
Ôï Lobby åßíáé ï éäåáôüò ÷þñïò óôïí ïðïßï âñß-
óõììåôå÷üíôùí.
óêïíôáé ìÝ÷ñé íá áñ÷ßóåé ç óýóêåøç. Äåí ðñÝ-
Ïé óçìåñéíÝò õðçñåóßåò Ý÷ïõí ìåãÜëåò äõíá-
ðåé íá óõã÷Ýåôáé ìå ôçí áíáìïíÞ.
ôüôçôåò êáé ðïéêéëßá ìåèüäùí ðñüóâáóçò.Ôá
Áí ïé óõììåôÝ÷ïíôåò åßíáé óå áðëÞ áíáìïíÞ
Personal Rooms åîõðçñåôïýí óõ÷íÝò óõóêÝ-
(On Hold), ôüôå óõíÞèùò áêïýí ìïõóéêÞ ìÝ÷ñé
øåéò ìå Ýìðéóôïõò óõíåñãÜôåò, åíþ ïé êùäéêïß
COMMUNICATION SOLUTIONS
SPRING 2022
Video Conference
One-Time Passcodes ðñïóöÝñïõí ìåãáëýôåñç
áíáöÝñèçêå, ç Ýííïéá Host / Guest óôï Audio
áóöÜëåéá ãéá åõêáéñéáêÝò óõóêÝøåò. Ç äõíá-
Conference áíôéóôïé÷åß ðéï óùóôÜ óôéò Ýííïéåò
ôüôçôá óýíäåóçò ìÝóù Audio Conference ìå
Host / Participant óå Video Conferencing, åíþ
ôïõò ßäéïõò êùäéêïýò åîõðçñåôåß ôçí åýêïëç
ôï Guest Passcode ïõóéáóôéêÜ éóïäõíáìåß ìå
÷ñÞóç ôçò õðçñåóßáò áí äåí õðÜñ÷åé ðñüóâá-
Ýíá Conference ID.
óç óå õðïëïãéóôÞ. Äõíáôüôçôåò üðùò ôï Lobby
Ï ìåôáó÷çìáôéóìüò ôçò ôå÷íïëïãßáò ôçëåäéÜ-
åîõðçñåôïýí óõóêÝøåéò üðïõ åëÝã÷åôáé ç ðñü-
óêåøçò åðéôá÷ýíèçêå áðü ôçí ðáíäçìßá ìå á-
óâáóç áðü ôïí Host.
ðïôÝëåóìá á) íá ìçí õðÜñ÷åé ðëÝïí æÞôçóç ãéá
Ìå áõôÝò ôéò ðïëëáðëÝò êáé ðñï÷ùñçìÝíåò
áìéãÝò Audio Conference êáèþò ç æÞôçóç ìåôá-
äõíáôüôçôåò ðñüóâáóçò, ïé õðçñåóßåò Cloud
ôïðßóôçêå ðñïò ôéò õðçñåóßåò ðïõ ðáñÝ÷ïõí
Video óÞìåñá ìðïñïýí íá åîõðçñåôïýí üóï ôï
üëïõò ôïõò ôñüðïõò óýíäåóçò (Audio, Video,
äõíáôüí ðåñéóóüôåñåò ðåñéðôþóåéò ÷ñÞóçò
all platforms, all networks) êáé â) áíÝâçêå ç
(use cases) ãéá ôïõò ðåëÜôåò ôïõò.
æÞôçóç ãéá åðéðëÝïí ÷áñáêôçñéóôéêÜ êáé äõíá-
Åßíáé óçìáíôéêü íá ðáñáôçñçèåß üôé ïé ðñï÷ù-
ôüôçôåò üðùò background replacement, voting/
ñçìÝíåò äõíáôüôçôåò êáé ïé äéÜöïñïé ôýðïé óõ-
polling, hand raise êáé Üëëá ó÷åôéêÜ.
óêÝøåùí êáé êùäéêþí ðïëëÝò öïñÝò öÝñíïõí
Óôï åðüìåíï ìÝñïò èá ðáñïõóéáóèïýí ÷áñá-
ôïõò áðëïýò ÷ñÞóôåò óå óýã÷õóç ìç êáôáíïþ-
êôçñéóôéêÜ óõóêÝøåùí ìÝóù ôùí õðçñåóéþí
íôáò ðïéÜ åßíáé ç êáôÜëëçëç õðçñåóßá ãéá áõ-
Cloud Video, üðùò ãéá ðáñÜäåéãìá ïé äõíáôü-
ôïýò. Ç óýíôïìç áëëÜ ðñïóåãìÝíç êáé êáôÜë-
ôçôåò äéá÷åßñéóçò ôçò åéêüíáò / video layouts,
ëçëç åêðáßäåõóç ôùí ÷ñçóôþí ìðïñåß íá âïç-
êáôáãñáöÞ, ðáñïõóéÜóåéò, øçöïöïñßåò êáé Üë-
èÞóåé óå áõôü.
ëá. ÊÜðïéåò áðü áõôÝò ôéò äõíáôüôçôåò èåù-
Ç «êëçñïíïìéÜ» ôçò ïñïëïãßáò êáé ôïõ ôñüðïõ
ñïýíôáé ðëÝïí áðáñáßôçôåò, åíþ êÜðïéåò Üëëåò
ëåéôïõñãßáò ôïõ Audio Conference ìðïñåß
áðïôåëïýí áíôáãùíéóôéêÜ ðëåïíåêôÞìáôá õøç-
åðßóçò íá äçìéïõñãÞóåé óýã÷õóç, êáèþò üðùò
ëÞò ôå÷íïëïãßáò.
Ëßãá ëüãéá ãéá ôïí áñèñïãñÜöï Ï ê. Äéïíýóçò ÆÝñâáò åßíáé Ìç÷áíéêüò UC êáé Ý÷åé åñãáóôåß óôéò ôå÷íïëïãßåò UC ãéá äýï äåêáåôßåò, êõñßùò ìå óõóôÞìáôá Polycom. Åðßóçò Ý÷åé åìðåéñßá video streaming êáé õðÞñîå team leader êáé åêðáéäåõôÞò ãéá managed video services êáé Ýñãá web collaboration. ÅñãÜóôçêå ãéá ôçí Polycom óôï Ëïíäßíï ãéá áñêåôÜ ÷ñüíéá, õëïðïéþíôáò ëýóåéò, êáé áñãüôåñá óå ñüëï õðïóôÞñéîçò ôùí ìåãÜëùí ðåëáôþí (Elite support), êáëýðôïíôáò ðåëÜôåò óôçí Åõñþðç, ÌÝóç ÁíáôïëÞ êáé ÁöñéêÞ. Ï Äéïíýóçò ÆÝñâáò Ý÷åé ðåñéóóüôåñåò áðü 50 ðéóôïðïéÞóåéò óå óõóôÞìáôá ôçëåäéÜóêåøçò êáé ôå÷íïëïãßåò Polycom, üðùò MCUs, Monitoring systems, Security / Firewall Traversal systems, Call Control platforms êáé ôåñìáôéêÜ ôçëåäéÜóêåøçò. ¸÷åé åðßóçò ëÜâåé ôçí ðéóôïðïßçóç Polycom Certified Video Engineer 3 öïñÝò, üðùò åðßóçò êáé ðéóôïðïéÞóåéò Wireshark, Microsoft Windows Server, Cisco CCNA, VMware êáé Üëëá. Ï Äéïíýóçò ÆÝñâáò Ý÷åé ðôõ÷ßï Master's (Communication Systems Engineering) êáé ðôõ÷ßï Bachelor's (Information Systems Engineering) óôá ðáíåðéóôÞìéá ôïõ ÇíùìÝíïõ Âáóéëåßïõ Portsmouth êáé Surrey, áíôßóôïé÷á.
ÅÜí åðéèõìåßôå ôï COMMUNICATION SOLUTIONS íá äçìïóéåýóåé ðåñéóóüôåñá Üñèñá ãéá Video Conference åðéêïéíùíÞóôå ìáæß ìáò óôï: info@comsol.gr
SPRING 2022
COMMUNICATION SOLUTIONS
45
Business
news CS
H Space Hellas "Cisco Collaboration Partner of the Year 2021" êáé "Webex Rising Star"
Ç Space Hellas âñßóêåôáé óôçí åõ÷Üñéóôç èÝóç íá áíáêïéíþóåé üôé Ýëáâå ôï âñáâåßï: "Cisco Collaboration Partner of the Year", êáôÜ ôç äéÜñêåéá ôïõ Cisco Partner Summit 2021 ðïõ äéåîÞ÷èç øçöéáêÜ óôéò 10 Íïåìâñßïõ. Ç äéÜêñéóç áõôÞ óõíéóôÜ áíáãíþñéóç áðü ôç Cisco ôçò îå÷ùñéóôÞò èÝóçò ðïõ êáôÝ÷åé ç Space Hellas ÷Üñéí óôçí åíôõðùóéáêÞ åðßôåõîç ôùí óôü÷ùí ôçò êáé ôçí ôïðïèåôåß óôçí ðñþôç èÝóç ìåôáîý ôùí óõíåñãáôþí ôçò ãéá ôçí ðåñéï÷Þ Europe South Theater/Greece, Cyprus & Malta. Ç åôáéñåßá ôéìÞèçêå ðñüóöáôá êáé ìå ôç óçìáíôéêÞ äéÜêñéóç "Webex Rising Star" ãéá ôçí ðåñéï÷Þ EMEAR. Ïé ðáñáðÜíù óçìáíôéêÝò âñáâåýóåéò áðïäåéêíýïõí Ýìðñáêôá ôçí áíáãíþñéóç ôçò Cisco óôéò åðéäüóåéò ôçò Space Hellas, ãéá ôçí áíÜðôõîç óõíå÷þò íÝùí êáéíïôüìùí ëýóåùí êáé õðçñåóéþí, üðùò Collaboration, Video Analytics êáé Web Intelligence. Ç åðéôõ÷ßá ôçò Space Hellas óôïí øçöéáêü ìåôáó÷çìáôéóìü ôùí åðé÷åéñÞóåùí, äçìéïýñãçóå åíôõðùóéáêÞ áíÜðôõîç óôçí åðé÷åéñçìáôéêÞ óõíåñãáóßá ôçò ìå ôç Cisco. Ïé ôéìçôéêÝò äéáêñßóåéò åðéâñáâåýïõí ôç óôñáôçãéêÞ åðéëïãÞ ôçò Space Hellas íá åßíáé áíôáãùíéóôéêÞ óôéò ëýóåéò Cisco äéåèíþò êáé íá êáéíïôïìåß óå óõíäõáóìü ìå ôçí õøçëÞ ôå÷íïãíùóßá êáé ôçí Üøïãç åîõðçñÝôçóç ðïõ ðáñÝ÷åé ôï ðéóôïðïéçìÝíï áíèñþðéíï äõíáìéêü ôçò. Ç Space Hellas óå Ýíá äõíáìéêÜ ìåôáâáëëüìåíï ðåñéâÜëëïí âñßóêåôáé êáé öÝôïò ìåôáîý ôùí åðéëåãìÝíùí óõíåñãáôþí ôçò Cisco ôïõò ïðïßïõò ôéìÜ ìå ôá âñáâåßá ôçò, ãéá ôçí õðïäåéãìáôéêÞ óõíåñãáóßá ðïõ åðéäåéêíýïõí êáé ôá Üñéóôá åðé÷åéñçóéáêÜ áðïôåëÝóìáôá ðïõ åðéôõã÷Üíïõí. Ç Space Hellas åßíáé Cisco Gold Certified Partner, ç óõíåñãáóßá ôùí äýï åôáéñåéþí îåðåñíÜ ôá 20 Ýôç êáé Ý÷åé íá åðéäåßîåé ðïëëÜ êáé óçìáíôéêÜ Ýñãá. Ïé ðïëëáðëÝò ôéìçôéêÝò äéáêñßóåéò ðïõ Ý÷åé ëÜâåé ç Space Hellas óå üëç ôç äéÜñêåéá ôçò ìáêñü÷ñïíçò óõíåñãáóßáò ôçò ìå ôç Cisco áðïôåëïýí äÝóìåõóç ðñïò üöåëïò ôùí ðïëõÜñéèìùí ðåëáôþí ôçò.
CS
¸îõðíåò åöáñìïãÝò ãéá ôçí ðñïþèçóç ôïõ èåìáôéêïý ôïõñéóìïý ôïõ ÄÞìïõ ÐáôñÝùí áðü ôç Space Hellas
Ç Space Hellas õëïðïßçóå Ýíá êáéíïôüìï Ýñãï ãéá ôïí ÄÞìï ÐáôñÝùí ðïõ óôü÷ï Ý÷åé ôçí ðñïþèçóç ôïõ èåìáôéêïý ôïõñéóìïý óôïí ÄÞìï êáé åéäéêüôåñá óôï éóôïñéêü êÝíôñï ôçò ÐÜôñáò. Ôï Ýñãï ðñïôÜèçêå êáé áíáãíùñßóèçêå ùò Ýñãï êáéíïôïìßáò áðü ôï ÔìÞìá Êáéíïôïìßáò ôïõ Õðïõñãåßïõ Åóùôåñéêþí. Óôü÷ïò ôïõ Ýñãïõ åßíáé ç áíÜðôõîç øçöéáêþí äéáäñáóôéêþí êáé ðïëõêáíáëéêþí õðçñåóéþí ðñïò ôïõò åðéóêÝðôåò, ãéá ôçí áíÜäåéîç êáé ðñïþèçóç ôïõ ôïõñéóìïý êáé ôïõ ðïëéôéóìïý ôçò ðåñéï÷Þò êáé ôçí åíßó÷õóç ôùí ôïðéêþí åðé÷åéñÞóåùí. Áðþôåñïò óêïðüò ôùí øçöéáêþí õðçñåóéþí åßíáé ç áíÜäåéîç ôçò ðåñéï÷Þò ôïõ éóôïñéêïý êÝíôñïõ ôçò ÐÜôñáò, êáèþò êáé ç åðÝêôáóç ôçò ôïõñéóôéêÞò ðåñéüäïõ êáé ç åíßó÷õóç ôçò ðïëéôéóôéêÞò êëçñïíïìéÜò êáé ôïðéêÞò ïéêïíïìßáò. Ìå ôçí ïëïêëÞñùóç ôïõ Ýñãïõ ï ÄÞìïò ÐáôñÝùí äçìéïýñãçóå ìéá óçìáíôéêÞ äñÜóç ìÝóù ôçò ðëáôöüñìáò explore.patras.gr, åíþ ðáñÜëëçëá áíáðôý÷èçêå êáé åöáñìïãÞ ãéá êéíçôÝò óõóêåõÝò ç ïðïßá áëëçëïåðéäñÜ ìå ôçí ðëáôöüñìá, ìå áíÜðôõîç ðïëëþí êáé åíäéáöåñüíôùí ðåñéå÷ïìÝíùí ãéá ôçí ðñïþèçóç ôçò ÐÜôñáò ùò ôïõñéóôéêïý ðñïïñéóìïý êáé áëëçëåðßäñáóçò åðéóêåðôþí. Ôï www.explore.patras.gr åßíáé Ýíáò éóôüôïðïò ðïõ óõãêåíôñþíåé ÷ñÞóéìåò ðëçñïöïñßåò ìå ôç ÷ñÞóç Ýîõðíùí åöáñìïãþí ðïõ ÷ñçóéìïðïéåß ï ÄÞìïò ÐáôñÝùí ãéá ôïí ôïõñéóìü óôçí ÐÜôñá. ÅðéôñÝðåé óôïõò åðéóêÝðôåò ôçò ðüëçò áëëÜ êáé óôïõò äçìüôåò íá ìðïñïýí ìÝóù ôçò éóôïóåëßäáò áëëÜ êáé ìÝóù QR codes, íá ëáìâÜíïõí ðëçñïöïñßåò ãéá ôçí ðüëç, áñ÷áéïëïãéêïýò ÷þñïõò, ìíçìåßá, ðïëéôéóôéêÜ êÝíôñá, äéáäñïìÝò, ê.ëð. Ïé QR codes åßíáé ôïðïèåôçìÝíïé óå åðéëåãìÝíá óçìåßá åíäéáöÝñïíôïò êáé ìðïñåß ï êáèÝíáò íá óêáíÜñåé êáé íá ëÜâåé ôéò ðëçñïöïñßåò. Ç åöáñìïãÞ (app) explore.patras.gr ðåñéëáìâÜíåé 44 óçìåßá åíäéáöÝñïíôïò. ÐÝñáí üìùò ôùí óçìåßùí áõôþí ðïõ ðåñéëáìâÜíïíôáé óÞìåñá óôçí åöáñìïãÞ, óôï ìÝëëïí èá ðñïóôåèïýí êáé Üëëá ìå ôçí óõìâïëÞ ôïõ Ðïëéôéóôéêïý Ïñãáíéóìïý ôïõ ÄÞìïõ ÐáôñÝùí. Ç Space Hellas åßíáé Ýíá äõíáìéêüò System Integrator ìå óçìáíôéêÞ åìðåéñßá êáé õøçëÞ ôå÷íïãíùóßá óôçí ïëïêëÞñùóç «Ýîõðíùí Ýñãùí». Ïé ïëïêëçñùìÝíåò ëýóåéò ðïõ äéáèÝôåé ðáñÝ÷ïõí áóýãêñéôá ðëåïíåêôÞìáôá êáé äçìéïõñãïýí íÝá äåäïìÝíá óôçí øçöéáêÞ åîÝëéîç êÜèå ïñãáíéóìïý. 46
COMMUNICATION SOLUTIONS
SPRING 2022
Business
news
CS
Ç PowerSales ðáñÝäùóå êáé Ýèåóå óå ëåéôïõñãßá óýóôçìá ÐáñÜëëçëùí Öïñôéóôþí óå Õðïóôáèìü ÐáñáãùãÞò ÇëåêôñéêÞò ÅíÝñãåéáò
Ç PowerSales ùò åðßóçìïò ìåôáðùëçôÞò êáé ðéóôïðïéçìÝíïò ðÜñï÷ïò ôå÷íéêÞò õðïóôÞñéîçò ôùí Áíïñèùôéêþí ÓõóôçìÜôùí ôçò Lever ðáñÝäùóå êáé Ýèåóå óå ëåéôïõñãßá åðéôõ÷þò Ýíá óýóôçìá ÐáñÜëëçëùí Öïñôéóôþí (ôýðïò SME110/250/SP, 110V/250A) õðïóôçñéæüìåíï áðü 2 óõóôïé÷ßåò óõóóùñåõôþí Íéêåëßïõ êáäìßïõ (85xKL560P/560Ah), ãéá ôçí õðïóôÞñéîç ôùí óõóôçìÜôùí áóöÜëåéáò êáé åëÝã÷ïõ óå Õðïóôáèìü ÐáñáãùãÞò ÇëåêôñéêÞò ÅíÝñãåéáò. Ïé åíÝñãåéåò ðïõ åêôåëÝóôçêáí ÷áñáêôçñéóôéêÜ Þôáí ïé åîÞò: l ÅðéëïãÞ ôïõ êáôÜëëçëïõ ÓõóôÞìáôïò êáé Äéáóôáóéïðïßçóç ôçò ÄéÜôáîçò Óõóóùñåõôþí âÜóç ôùí äåäïìÝíùí ôå÷íéêþí ðñïäéáãñáöþí ôçò åöáñìïãÞò. l ÄéåîáãùãÞ Äïêéìþí Ðéóôïðïßçóçò Áíïñèùôéêþí ÓõóôçìÜôùí (FATs) êáé Äïêéìþí Öüñôéóçò & Åêöüñôéóçò Óõóóùñåõôþí. l Åêêßíçóç ôïõ Áíïñèùôéêïý ÓõóôÞìáôïò, äïêéìÝò ðáñÜäïóçò êáé åêðáßäåõóç ôïõ ðñïóùðéêïý ôïõ ðåëÜôç, óýìöùíá ìå ôéò ÅëëçíéêÝò, ÅõñùðáúêÝò áëëÜ êáé Äéåèíåßò ÐñïäéáãñáöÝò. Ç PowerSales éäñýèçêå ôï 2001 ìå óêïðü ôçí åìðïñéêÞ êáé ôå÷íéêÞ õðïóôÞñéîç ÓõóôçìÜôùí ÁäéÜëåéðôçò Ðáñï÷Þò Éó÷ýïò (UPS). Ç óõóóùñåõìÝíç åìðåéñßá 21 åôþí ôçò äßíåé ôç äõíáôüôçôá íá ðáñÝìâåé óå üëá ôá óôÜäéá ìåëÝôçò êáé åãêáôÜóôáóçò åíüò Áíïñèùôéêïý ÓõóôÞìáôïò.
CS
Ç Unixfor óôçí ÁìåñéêÞ ãéá ìßá óõíåñãáóßá ðïëëþí «ïêôáíßùí»
Óå ìßá íÝá õðåñáôëáíôéêÞ óõíåñãáóßá ðñï÷þñçóå ç Unixfor, âÜæïíôáò åëëçíéêÞ õðïãñáöÞ óôï íÝï project ôçò ATIOVAR ãéá ëïãáñéáóìü ôçò TERPEL. Ç ATIOVAR - åôáéñåßá ìå Ýäñá ôéò ÇíùìÝíåò Ðïëéôåßåò ðïõ ðáñÝ÷åé ïëïêëçñùìÝíåò ëýóåéò óôïí ðåôñåëáúêü êëÜäï ÊåíôñéêÞò & Íüôéáò ÁìåñéêÞò - áíÝëáâå íá åêóõã÷ñïíßóåé êáé íá áíáâáèìßóåé ôï éäéáßôåñá åêôåôáìÝíï äßêôõï ðñáôçñßùí êáõóßìùí ôçò TERPEL óôïí ÐáíáìÜ. Ç TERPEL ìå éó÷õñÞ ðáñïõóßá óôç Íüôéá ÁìåñéêÞ åßíáé ãíùóôÞ ãéá ôéò ðñùôïâïõëßåò ôçò óôçí óõíå÷Þ åîÝëéîç ôùí ðñáôçñßùí ôçò áëëÜ êáé ôçò åìðåéñßáò ðïõ ðñïóöÝñåé óôïõò ðåëÜôåò ôçò, þóôå íá éêáíïðïéåß óõíå÷þò ôçí áðáéôçôéêÞ êáé äéáñêþò åîåëéóóüìåíç áãïñÜ. Êïìâéêü ñüëï óôç áíáâÜèìéóç ôùí ðñáôçñßùí ôçò TERPEL áíÝëáâå ç Unixfor, ç ïðïßá ðñïìÞèåõóå ôçí ATIOVAR ìå state-of-the-art áõôüìáôïõò ðùëçôÝò êáõóßìùí (OPT Kiosks), åîåéäéêåõìÝíï ëïãéóìéêü ãéá ëýóåéò self-service êáèþò êáé ìå ëïãéóìéêü áðïìáêñõóìÝíçò ðáñáêïëïýèçóçò & äéá÷åßñéóçò ôùí OPT. Ç áîéïðïßçóç ôçò ôå÷íïãíùóßáò ôçò Unixfor êáé ç Üñéóôç óõíåñãáóßá ìå ôïõò ìç÷áíéêïýò ôçò ATIOVAR ïäÞãçóå óôçí óýíôïìç õëïðïßçóç ôïõ ðéëïôéêïý Ýñãïõ. Ôáõôü÷ñïíá, ç ðïéüôçôá êáé ç ðëçèþñá ôå÷íéêþí ÷áñáêôçñéóôéêþí ôùí OPT Kiosks êáé ôïõ ëïãéóìéêïý, áëëÜ êáé ç áðïäï÷Þ ôïõ ðéëïôéêïý áðü ôïõò áõôïêéíçôéóôÝò åß÷áí óáí áðïôÝëåóìá ôçí Üìåóç Ýãêñéóç ôçò TERPEL ãéá ôï rollout ôïõ project, åîïðëßæïíôáò Ýôóé ôï óýíïëï ôùí ðñáôçñßùí ìå Ýíá íÝï, self-service êáíÜëé åîõðçñÝôçóçò. SPRING 2022
COMMUNICATION SOLUTIONS
47
#114
#120
#115
#116
#121
#122
#117
#118
#119
#123
#124
#125
ÄÅËÔÉÏ ÓÕÍÄÑÏÌÇÔÇ ÐÅÑÉÏÄÉÊÏÕ COMMUNICATION SOLUTIONS ÓÔÏÉ×ÅÉÁ ÅÔÁÉÑÅÉÁÓ ÅÐÙÍÕÌÉÁ ÅÔÁÉÑÅÉÁÓ:
ÈÅÓÇ ÓÔÇÍ ÅÔÁÉÑÅÉÁ:
ÅÐÙÍÕÌÏ:
ÏÍÏÌÁ:
ÄÉÅYÈÕÍÓÇ: ÔÇËÅÖÙÍÏ:
ÔÊ: FAX:
ÐÏËÇ: e-mail:
ÄÏÕ:
Á.Ö.Ì.:
Ðáñáêáëþ åããñÜøôå ìå óõíäñïìçôÞ óôï COMMUNICATION SOLUTIONS
ÅÔÇÓÉÁ ÓÕÍÄÑÏÌÇ 2022
90,00
ÓÕÍÄÑÏÌÅÓ ÅÎÙÔÅÑÉÊÏÕ (ÅôÞóéá)
130,00
ÁÐÅÓÔÅÉËÁ ÃÉÁ ÔÇÍ ÅÎÏÖËÇÓÇ: ÔÁ×. ÅÐÉÔÁÃÇ Íï
ÔÑÁÐÅÆÉÊÇ ÅÐÉÔÁÃÇ Íï
ÊÁÔÁÈÅÓÇ ÓÅ ÔÑÁÐÅÆÉÊÏ ËÏÃÁÑÉÁÓÌÏ ÊÁÔÏÐÉÍ ÓÕÍÅÍÍÏÇÓÅÙÓ
ÇÌÅÑÏÌÇÍÉÁ ÌÅ ÁÍÔÉÊÁÔÁÂÏËÇ ÕÐÏÃÑÁÖÇ
*Óôéò ôéìÝò óõìðåñéëáìâÜíåôáé ÖÐÁ 6%
P ioannides
publications
Magazines l Conferences l Books
Moutalaski 53, 142 34 Athens, Greece
48
COMMUNICATION SOLUTIONS
info@comsol.gr ++30 6977282416
www.comsol.gr SPRING 2022
7th
ens A th
2022
Conference
Unified Communications & Collaboration Conference Athens Domotel Kastri Hotel TBA
GREECE 2022
Connect, communicate, collaborate anywhere, anytime on any device
The new way of working Organized by
Communication Solutions The networking magazine
Introducing a Deskphone That Makes You More Mobile
Mi Voice 6940 IP Phone
Keeping people connected and productive while making communication a whole lot easier
—anytime, anywhere, on any device. The MiVoice 6900 series boasts exceptional HD audio quality, one-touch Bluetooth pairing and seamless integration with your mobile phone. The series of phones can keep you productive by allowing an easy and intuitive way to switch calls between your desk phone and your mobile phone.
Integrated Enterprise Networks is Mitel’s Gold partner for Greece.
Contact us to work together to find the best solution for you. Integrated Enterprise Networks S.A., 72 Agias Varvaras Str. 17235, Dafni, Athens-Greece Phone: +30 210 9762747 | Fax: +30 210 9763379 | e-mail: info@ien.gr | www.ien.gr