INPUT / OUTPUT CARDS Input / output cards are used for reading in of floating contacts and / or operating of controls such as door openers or barriers via floating relay contacts (depending on type).

Technical data: Outputs: floating relay contacts, maximum switching power 60 W resp. 125 VA, maximum switching current 2 A, maximum switching voltage 60 VDC / 40 VAC. Inputs for floating contacts, maximum line resistance 600 ohm.

G1-16A Plug-in card with 16 relay outputs (4 of which are make, open or switch over contacts, 12 only as make contacts). Connection via plugable screw terminals. W 60 mm, H 160 mm, D 20 mm

204 g

G1-16E Plug-in card with 16 inputs for floating contacts, with or without line monitoring. Read in of 5 operation states (Idle, Active 1, Active 2, Short, Line break). Connection via plugable screw terminals. W 60 mm, H 160 mm, D 20 mm

146 g

G1-8E8A Plug-in card with 8 inputs for floating contacts and 8 relay outputs (make, open or switch over). Read in of 5 operation states with inputs (Idle, Active 1, Active 2, Short, Line break). Connection via plugable screw terminals. W 60 mm, H 160 mm, D 20 mm

182 g

INTERFACE CARDS For integration and connection of external systems such as a telephone or PC, etc.

G1-V24 Interface card with standard protocol for connection of external systems, e.g. video switchers or host computers. Two RS 232 interfaces (of which one can be configured as RS 422). Connection via two serial D-Submin-sockets for RS 232, screw terminals for RS 422. W 60 mm, H 160 mm, D 20 mm

149 g

G1-TEL Multi-functional telephone interface for connection of the Intercom System to an analogue 足subscriber of a telephone system, directly to a standard telephone line or pager system. Telephone mode for direct dialling of the desired telephone number from an Intercom station. Auto Dialler mode with 足automatic dialling of freely programmable dialling sequences initiated by calls or call requests as well as pager mode for direct addressing of pagers. Freely configurable speech storage for acoustic identification and messages (e.g. waiting information) in dialler mode. DTMF-telephones can operate functions in the Intercom system (e.g. once call has been received on a remote telephone (for 足example) all after dial functions are available). Connection via RJ11 telephone socket. W 60 mm, H 160 mm, D 20 mm

344 g

CONNECTION CARDS For connection of Intercom Servers via 2 or 4-wire lines (leased lines).

G1-GEL Plug-in card for creating connections (tielines) to other Intercom Servers via telephone leased lines. Permanent connection via 2-wire or 4-wire fixed connections. Fully automatic hybrid balance due to signal processors in 2-wire operation. Connection via four screw terminals. W 60 mm, H 160 mm, D 20 mm

167 g