Andrew Accessories for Heliax Products

Page 55

Appendix 6 Hanger Spacing Guidelines

Click-On Hanger—Recommended Maximum Hanger Spacing Cable Size

Cable Part Number

Hanger Part Number

Recommended Maximum Hanger Spacing, feet (meters)

Wind Speed

85 mph (137 km/h)

Radial Ice

100 mph (160 km/h)

No Ice

1/2" (13 mm)

1" (25 mm)

No Ice

1/2" (13 mm)

1" (25 mm)

1/2"

LDF4-50A

L4CLICK, 1 Stack

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

1/2"

LDF4-50A

L4CLICK, 2 Stack

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

1/2"

LDF4-50A

L4CLICK, 3 Stack

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

Note: These same hanger spacing recommendations apply for the other following 1/2 in cable types: LDF4-75A, HL4RP-50, HLT4-50, HS4RP-50, HST4-50, HT4-50, HJ4-50

5/8"

LDF4.5-50A

L45CLICK, 1 Stack

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

5/8"

LDF4.5-50A

L45CLICK, 2 Stack

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

5/8"

LDF4.5-50A

L45CLICK, 3 Stack

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

Note: These same hanger spacing recommendations apply for the other following 5/8 in cable types: HJ4.5-50

7/8"

LDF5-50A

L5CLICK, 1 Stack

4 (1.2)

4 (1.2)

4 (1.2)

3 (0.9)

3 (0.9)

3 (0.9)

7/8"

LDF5-50A

L5CLICK, 2 Stack

4 (1.2)

4 (1.2)

4 (1.2)

3 (0.9)

3 (0.9)

3 (0.9)

7/8"

LDF5-50A

L5CLICK, 3 Stack

4 (1.2)

4 (1.2)

4 (1.2)

3 (0.9)

3 (0.9)

3 (0.9)

Note: These same hanger spacing recommendations apply for the other following 7/8 in cable types: AVA5-50, VXL5-50, AL5-50, HJ5-50, HJ5-75, HT5-5

1-1/4"

LDF6-50

L6CLICK, 1 Stack

4 (1.2)

4 (1.2)

4 (1.2)

3 (0.9)

3 (0.9)

3 (0.9)

1-1/4"

LDF6-50

L6CLICK, 2 Stack

4 (1.2)

4 (1.2)

4 (1.2)

3 (0.9)

3 (0.9)

3 (0.9)

1-1/4"

LDF6-50

L6CLICK, 3 Stack

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

1-5/8"

LDF7-50A

L7CLICK, 1 Stack

4 (1.2)

4 (1.2)

4 (1.2)

3 (0.9)

3 (0.9)

3 (0.9)

1-5/8"

LDF7-50A

L7CLICK, 2 Stack

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

1-5/8"

LDF7-50A

L7CLICK, 3 Stack

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

3 (0.9)

Note: These same hanger spacing recommendations apply for the other following 1 5/8 in cable types: HJ7-50A, AVA7-50, AL7-50 * These hanger spacings have been specified based on using the Click-On Hangers with Andrew specified hardware kits. (Note: Standard tower configuration spacing is 3 to 4 ft) Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees). Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occurring simultaneously. 2. Wind speeds are maximum, which includes gust factors and exposure factors.

Andrew Corporation

phone 1.800.255.1479 • 1.708.873.2307

fax 1.800.349.5444 • 1.779.435.8579

www.andrew.com

53


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.