Wood frame Multifamily housing - Revit Project - 2018

Page 1


t t

2 544 287

t

2 544 288

N

t

et

x

e t

x

13

, 25

t

e

e

t

t

e

t

t

e

t

e

e

et

4,41

lot #102

174°

172°

x

1997 pi2 PARTIE PRIVATIVE

2,16

4,80

e

x

178°

e

e

x

x

x

lot #103

PATIO 18'-0" X 15'-0"

et

1 865 pi2 PARTIE PRIVATIVE

x

x

3 231 551

x

t

L'ENTREPENEUR DOIT:

BALCON EN BOIS 10'-0" X 4'-4"

t

x

lot #104

et

BALCON EN BOIS 10'-0" X 4'-4"

1) VÉRIFIER TOUTES LES DIMENSIONS AVANT DE DÉBUTER LES TRAVAUX. 2) RESPECTER S'IL Y A LIEU TOUTES LES EXIGENCES DES DOCUMENTS CONNEXES AU PLANS ET INFORMER LE CLIENT DE TOUTES CONSÉQUENCES DUES AUX CHANGEMENTS QUI SERONT APPORTÉS AUX PLANS.

LIGNE DE LOT

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS.

2 968 pi2 PARTIE PRIVATIVE

33,34

x

x

NOTES GÉNÉRALES

62 °

-LES COTES ET LES DIMENSIONS ONT PRIORITÉ SUR LES DESSINS CERTAINES COTES SONT SUJETTES À UN AJUSTEMENT EN FONCTIONS DES MATÉRIAUX ET/OU MÉTHODES CHOISIS PAR L'ENTREPRENEUR. - SI L'ENTREPRENEUR VENAIT À CONSTATER DES DIFFÉRENCES ENTRE LE CHANTIER ET LE PRÉSENT PLAN, IL EST INVITÉ À CONTACTER LE RESPONSABLE DES PLANS DANS LES PLUS BREFS DÉLAIS.

PATIO et 27'-10" X 15'-0"

x et

x

LÉGENDE

29,38

e

www.emsom.qc.ca

te

et

SUPERFICIE 341.70 pi²

0 5,9

150°

x e

et

e

e

et

x

x

e

x

AQUEDUC

a

a

ÉGOÛT

s

s

TÉLÉPHONE

t

t

ÉLECTRICITÉ

e

e

x

CLÔTURE

x

PARTIE PRIVATIVE

2 29,8

SUPERFICIE 2213.33 pi²

L'ENTREPRENEUR OU MAITRE D'OEUVRE AVANT D'ENTREPRENDRE LES TRAVAUX DEVRA MESURER SUR PLACE ET COORDONNER TOUT LES NIVEAUX, TOUTES LES PENTES ET TOUTES LES DIMENSIONS SUR LE CHANTIER AVANT L'ÉXÉCUTION DES TRAVAUX. TOUTES LES STRUCTURES DEVRONT ÊTRES VÉRIFIÉS ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURE.

PRÉVOIR UN PLOMBIER CERTIFIÉ POUR L'INSTALLATION DE LA TUYAUTERIE. -LE BÉTON UTILISÉ DOIT ÊTRE PRODUIT ET LIVRÉ PAR UNE USINE DÉTENANT UN CERTIFICAT DE CONFORMITÉ.

SUPERFICIE 201.06 pi²

3 910 pi2

NOTES IMPORTANTES:

PRÉVOIR UN MAÎTRE ÉLECTRICIEN POUR L'INSTALLATION ÉLECTRIQUE.

3 231 552

x

lot #101

x

e

e

e

4,94

x et

t

t

1,66

x

3 402 479

t

e

31,00

x

x

x

x

-LA PROFONDEUR MINIMALE DES FONDATIONS EN-DESSOUS DU NIVEAU DU SOL FINI EST DE 4'-6".CETTE PROFONDEUR PEUT VARIER SELON LES RÉGIONS ET LE CODE EN VIGUEUR. -IL EST OBLIGATOIRE DE VENTILER ADÉQUATEMENT LA TOITURE. LES VENTILATEURS CHOISIS PAR LE CLIENT ET/OU L'ENTREPRENEUR DEVRONT RESPECTER LE CODE EN VIGUEUR.

POTEAU DE SERVICE

-LES DIMENSIONS DES FENÊTRES AU PLAN PEUVENT VARIER SELON LE FABRICANT CHOISI, LES FENÊTRES DOIVENT RESPECTER LA NORME NORD-AMÉRICAINE (AAMA/WDMA/CSA), LA CATÉGORIE R EST LE NIVEAU DE CLASSIFICATION MINIMUM ACCEPTÉ. -LES PARE-VAPEURS MENTIONNÉS AUX PLANS DEVRONT ÊTRE SCELLÉS LORSQU'ILS SERONT SUPERPOSÉS ET AUTOUR DES OUVERTURES.IL EST IMPORTANT D'INSTALLER UN PARE-VAPEUR À L'ARRIÈRE DES BOITES ÉLECTRIQUES ET DE LE SCELLER.

BORNES

x GARAGE

GARAGE

x

NOTES STRUCTURES:

ARBRES

TOUTES LES STRUCTURES DOIVENT ÊTRE VÉRIFIÉES ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURES.

x

EMPATTEMENT: LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉ SELON LA NATURE DU SOL. VÉRIFIÉ PAR INGÉNIEUR. BOIS: LE BOIS UTILISÉ SERA DE L'ÉPINETTE, DE GRADE #1 OU MEILLEUR.

x

x

x

x

x

x

x

x

x

POTEAUX TYPES: LES POTEAUX DANS LES MURS EXTÉRIEURES DOIVENT ÊTRE MIN 3-2"X6 SAUF INDICATION CONTRAIRE.

Érable 6'

x

Érable 10'

LES POTEAUX DANS LES MURS INTÉRIEURS DOIVENT ÊTRE MIN 3-2"X4" SAUF INDICATION CONTRAIRE.

x

POUTRES: LA POUTRE AU SOUS-SOL DE TYPE W EN ACIER SERA À CALCULER ET VÉRIFIER PAR FABRICANT.

32'-5"

8'-8" X 4'-9"

8'-8" X 4'-9"

PLANCHERS POUTRELLES: CHOISIR LA FLEXIBILITÉ DES POUTRELLES EN FONCTION DES REVÊTEMENTS DE PLANCHER, VOIR CLIENT. DOUBLER LES POUTRELLES AU POURTOUR DES PUITS D'ESCALIER.

21'-11"

9'-0"

8'-0"

8'-0"

ENTRÉE EN PAVÉS

E ENTRÉ LTÉE AS PHA

IMPLANTATION

ENTRÉE ASPHALTÉE

as

R 62,90

R 62,90

ÉCHELLE : 1/8" = 1'-0"

MAISON MULTIFAMILIALE

R 62,90

A 6,4

s aA 6,44

0

SE RÉFÉRER AU PLAN DE TOITURE FOURNI PAR LE FABRICANT DES FERMES DE TOIT POUR L'EMPLACEMENT EXACT DES APPUIS ET DES POUTRES ET/OU DES FERMES MAÎTRESSES.

9'-0"

MUR DE MACONNERIE -DANS UN MUR DE MACONNERIE, LES ATTACHES DE MÉTAL SERONT ESPACÉES DE 3'-0" MAX. À L'HORIZONTALE ET À 16" MA. À LA VERTICALE, LA GROSSEUR DES LINTEAUX D'ACIER AU-DESSUS DES OUVERTURES SERA DÉTERMINÉE PAR LE MAÇON.

ENTRÉE EN PAVÉS

A 10,01

as

A 6,49

RUE DES MÉSANGES 3 231 579 rue 14m de large

sa

TR O T TOIR

as

Implantation

sa as sa sa

a

a

a

a s

s

a s

a s

a

s

a

a

a

s

s

s

a

s

s

a s

a

s

s

a

a s

s

s

a s s

a

a

a

s

s

s GAS

GAS GAS

GAS

a

0001

Numéro de projet

as

Date

a s

a s

a s

a

s

Dessiné par

a s

a s

a s

Vérifié par

a s

a

s

a s

a s

Cindy Okino Nathalie Martel

A101

a Echelle

s

Novembre 2018

1/8" = 1'-0"

2018-12-05 09:46:44

R 62,9

LE BOIS UTILISÉS À LA FABRICATION DES FERMES PRÉFABRIQUÉES DOIVENT ÊTRE CONFORMES À LA NORME CAN3-086 ET AU CODE NATIONAL DU BÂTIMENT DU CANADA.

30'-105 8"

33'-113 8"

FERMES DE TOIT

29'-714"

t

e t

e

te

t

3 231 550

t

6,00

e

e

et e

te

33,35

t

te

t

137°

t t

t

e

t 2 544 286

te

et

e

e e


IMPORTANT: SELON LE C.N.B. POUR LES ESCALIERS ART.8.8.2.2 - ÉCHAPÉE MESURER À PARTIR DU BORD EXTÉRIEUR DU NEZ DE MARCHE 1950 MM (77 PO) MIN. ART.9.8.8.4 - HAUTEUR GARDE-CORPS INTÉRIEUR DES LOGEMENTS ET SI MAX.71 PO AUDESSUS DU SOL 900 MM (36 PO DE HAUT) 1070 MM (41 PO DE HAUT) POUR PLUS DE 71 PO AU-DESSUS DU SOL. ART.9.8.8.5 - OUVERTURES ENTRE LES BAROTINS 100 MM MAX(4 PO) ENTRE LES BAROTINS. ART 9.8.7.1 - MAINS COURANTES EXIGÉES UNE MAIN COURANTE DOIT ÊTRE INSTALLÉE SUR AU MOINS 1 CÔTÉ D'UN ESCALIER. SUR LES 2 CÔTÉS POUR UN ESCALIER TOURNANT.

www.emsom.qc.ca

ART 9.8.7.4 - HAUTEUR DES MAINS COURANTES DOIVENT AVOIR UNE HAUTEUR D'AU MOINS 800 MM ET D'AU PLUS 965 MM (30 À 34 PO DE HAUT).

70' - 0" 15' - 0"

20' - 0" 2' - 8" 4"

ENTRÉE EN VIGUEUR AU CODE DU CNB 2010 MODIFIÉ UN AVERTISSEUR DE FUMÉE DOIT ÊTRE INSTALLÉ DANS CHAQUE PIÈCE OÙ L'ON DORT (1X CHAMBRE) AINSI QUE UN PAR ÉTAGE DANS LES CORRIDORS INCLUANT LE SOUS-SOL. UN DÉTECTEUR DE MONOXYDE DE CARBONE (CO) EST REQUIS S'IL Y A UN FOYER AU GAZ OU AU BOIS OU UN GARAGE ANNEXÉ À LA MAISON.UN DÉTECTEUR COMBINÉ EST AUTORISÉ IL DOIT ÊTRE SITUÉ DANS LE CORRIDOR À MOINS DE 5 M DES CHAMBRES À COUCHER.(VOIR ARTICLE 9.32.3.9 DU CNB).

20' - 0"

10' - 0"

7' - 4"

9' - 4"

DESSUS DALLE PERRON

7' - 4"

4"

4"

B

D

A108

A109 DESSUS DALLE PERRON

ROBINET ANTIGEL

AU-DESSUS DALLE DE BÉTON (32 MPA MIN.) + ARMATURE

ROBINET ANTIGEL

2' - 8"

9' - 4"

99'-10"

SOLAGE 8" TYPE (SAUF OU NOTE)

NOTES GÉNÉRALES

15' - 0" 10' - 0"

4' - 4"

PRÉVOIR UN DÉTECTEUR DE FUMÉE À L'ÉTAGE, DANS TOUS LES CHAMBRES (OU À MOINS DE 16'-0" DE LA PORTE DE DE CELLE-CI DANS UN CORRIDOR). L'INSATALLATION SERA CONFORME AU CNB DU QUÉBEC

4' - 0"

SELON LE C.N.B. POUR NORMES INCENDIES

4"

L'ENTREPENEUR DOIT: 4 PILASTRES DE BÉTON 8" dia. SUR EMPATTEMENTS 30" X 30" X 10" + ARMATURE 5#5 (2 SENS)

1) VÉRIFIER TOUTES LES DIMENSIONS AVANT DE DÉBUTER LES TRAVAUX. 2) RESPECTER S'IL Y A LIEU TOUTES LES EXIGENCES DES DOCUMENTS CONNEXES AU PLANS ET INFORMER LE CLIENT DE TOUTES CONSÉQUENCES DUES AUX CHANGEMENTS QUI SERONT APPORTÉS AUX PLANS.

99'-10"

-LES COTES ET LES DIMENSIONS ONT PRIORITÉ SUR LES DESSINS CERTAINES COTES SONT SUJETTES À UN AJUSTEMENT EN FONCTIONS DES MATÉRIAUX ET/OU MÉTHODES CHOISIS PAR L'ENTREPRENEUR. - SI L'ENTREPRENEUR VENAIT À CONSTATER DES DIFFÉRENCES ENTRE LE CHANTIER ET LE PRÉSENT PLAN, IL EST INVITÉ À CONTACTER LE RESPONSABLE DES PLANS DANS LES PLUS BREFS DÉLAIS.

AU-DESSUS DALLE DE BÉTON (32 MPA MIN.) + ARMATURE

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS.

À NOTER

NOTES IMPORTANTES:

*SYSTÈME ÉCHANGEUR D'AIR OBLIGATOIRE DEPUIS 2012 ENTRÉE ET SORTIE POUR ÉCHANGEUR D'AIR À COORDONNER SUR PLACE

L'ENTREPRENEUR OU MAITRE D'OEUVRE AVANT D'ENTREPRENDRE LES TRAVAUX DEVRA MESURER SUR PLACE ET COORDONNER TOUT LES NIVEAUX, TOUTES LES PENTES ET TOUTES LES DIMENSIONS SUR LE CHANTIER AVANT L'ÉXÉCUTION DES TRAVAUX.

PRÉVOIR PANNEAU ÉLECTRIQUE 200 AMP.

C

*SORTIE POUR HOTTE DE CUISINIÈRE À COORDONNER SUR PLACE.

TOUTES LES STRUCTURES DEVRONT ÊTRES VÉRIFIÉS ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURE.

A109

PRÉVOIR UN MAÎTRE ÉLECTRICIEN POUR L'INSTALLATION ÉLECTRIQUE.

DRAIN PÉRIMETRIQUE 4" dia. AU POURTOUR DES EMPATTEMENTS INCLUANT DES CHÉMINÉES D'ACCEÈS VERTICAL POUR FACILITER LE NETTOYAGE DES DRAINS.

2' - 0" 8" 12' - 10"

7' - 2"

7' - 2"

12' - 10"

EMPATTEMENT 26" X 26" X 10" + ARMATURE 5#5 (2 SENS) POUR CHARGE DE 8500 lbs

PRÉVOIR UN PLOMBIER CERTIFIÉ POUR L'INSTALLATION DE LA TUYAUTERIE. -LE BÉTON UTILISÉ DOIT ÊTRE PRODUIT ET LIVRÉ PAR UNE USINE DÉTENANT UN CERTIFICAT DE CONFORMITÉ.

17' - 2 1/2"

17' - 6 1/2"

DRAIN PÉRIMETRIQUE 4" dia. AU POURTOUR DES EMPATTEMENTS INCLUANT DES CHÉMINÉES D'ACCEÈS VERTICAL POUR FACILITER LE NETTOYAGE DES DRAINS.

*SORTIE POUR APPAREIL MÉNAGER À COORDONNER SUR PLACE.

-LA PROFONDEUR MINIMALE DES FONDATIONS EN-DESSOUS DU NIVEAU DU SOL FINI EST DE 4'-6".CETTE PROFONDEUR PEUT VARIER SELON LES RÉGIONS ET LE CODE EN VIGUEUR. -IL EST OBLIGATOIRE DE VENTILER ADÉQUATEMENT LA TOITURE. LES VENTILATEURS CHOISIS PAR LE CLIENT ET/OU L'ENTREPRENEUR DEVRONT RESPECTER LE CODE EN VIGUEUR. -LES DIMENSIONS DES FENÊTRES AU PLAN PEUVENT VARIER SELON LE FABRICANT CHOISI, LES FENÊTRES DOIVENT RESPECTER LA NORME NORD-AMÉRICAINE (AAMA/WDMA/CSA), LA CATÉGORIE R EST LE NIVEAU DE CLASSIFICATION MINIMUM ACCEPTÉ.

EMPATTEMENT 26" X 26" X 10" + ARMATURE 5#5 (2 SENS) POUR CHARGE DE 8500 lbs

-LES PARE-VAPEURS MENTIONNÉS AUX PLANS DEVRONT ÊTRE SCELLÉS LORSQU'ILS SERONT SUPERPOSÉS ET AUTOUR DES OUVERTURES.IL EST IMPORTANT D'INSTALLER UN PARE-VAPEUR À L'ARRIÈRE DES BOITES ÉLECTRIQUES ET DE LE SCELLER.

EMPATTEMENT 36" X 26" X 10" + ARMATURE 5#5 (2 SENS) POUR CHARGE DE 8500 lbs

NOTES STRUCTURES: ENCOCHE 2" X 6" TOUTES LES STRUCTURES DOIVENT ÊTRE VÉRIFIÉES ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURES.

DESSUS DALLE RDC

EMPATTEMENT: LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉ SELON LA NATURE DU SOL. VÉRIFIÉ PAR INGÉNIEUR.

100'-0"

DESSUS DALLE RDC

44' - 0"

44' - 4"

FONDATION 6'-6" DE HAUT TYPE

100'-0"

2' - 0" TYPE

POTEAUX TYPES: LES POTEAUX DANS LES MURS EXTÉRIEURES DOIVENT ÊTRE MIN 3-2"X6 SAUF INDICATION CONTRAIRE. LES POTEAUX DANS LES MURS INTÉRIEURS DOIVENT ÊTRE MIN 3-2"X4" SAUF INDICATION CONTRAIRE.

8" TYPE

FONDATION 6'-2" DE HAUT PARTIE NON-EXCAVÉ EAU-DESSUS DALLE DE BÉTON 4" + TREILLIS MÉTALIQUE SUR PIERRE CONCASSÉE 10"

PARTIE NON-EXCAVÉ EAU-DESSUS DALLE DE BÉTON 4" + TREILLIS MÉTALIQUE SUR PIERRE CONCASSÉE 10"

22' - 3 1/2"

POUTRES: LA POUTRE AU SOUS-SOL DE TYPE W EN ACIER SERA À CALCULER ET VÉRIFIER PAR FABRICANT.

20' - 0"

SEMELLES

BOIS: LE BOIS UTILISÉ SERA DE L'ÉPINETTE, DE GRADE #1 OU MEILLEUR.

PLANCHERS POUTRELLES: CHOISIR LA FLEXIBILITÉ DES POUTRELLES EN FONCTION DES REVÊTEMENTS DE PLANCHER, VOIR CLIENT. DOUBLER LES POUTRELLES AU POURTOUR DES PUITS D'ESCALIER. FERMES DE TOIT

DESSUS DALLE GARAGE

98'-6"

13' - 0"

7' - 0"

7' - 0"

DESSUS DALLE GARAGE

13' - 0"

LE BOIS UTILISÉS À LA FABRICATION DES FERMES PRÉFABRIQUÉES DOIVENT ÊTRE CONFORMES À LA NORME CAN3-086 ET AU CODE NATIONAL DU BÂTIMENT DU CANADA.

98'-6"

SE RÉFÉRER AU PLAN DE TOITURE FOURNI PAR LE FABRICANT DES FERMES DE TOIT POUR L'EMPLACEMENT EXACT DES APPUIS ET DES POUTRES ET/OU DES FERMES MAÎTRESSES.

A A108 DESSUS DALLE ENTRÉE

ROBINET + VALVE

DESSUS DALLE PERRON

AU-DESSUS DALLE DE BÉTON (32 MPA MIN.) + ARMATURE

8' - 0"

AU-DESSUS DALLE DE BÉTON (32 MPA MIN.) + ARMATURE

8" 8"

8' - 0"

35' - 0"

SEMELLES & MURS

11' - 4"

15' - 0" 35' - 0"

MAISON MULTIFAMILIALE Plan des Fondations

70' - 0"

0001

Numéro de projet Date

PLAN DES FONDATIONS ÉCHELLE : 1/4" = 1'-0"

Dessiné par Vérifié par

Novembre 2018 Cindy Okino Nathalie Martel

A102 Echelle

1/4" = 1'-0"

2018-12-05 09:48:24

11' - 4"

98'-6"

4' - 6"

98'-6"

4 1/2"

4' - 6"

ENTRÉE D'EAU DESSUS DALLE PERRON

3' - 0"

2' - 3 1/2"

ROBINET + VALVE

ENTRÉE D'EAU

15' - 0"

MUR DE MACONNERIE -DANS UN MUR DE MACONNERIE, LES ATTACHES DE MÉTAL SERONT ESPACÉES DE 3'-0" MAX. À L'HORIZONTALE ET À 16" MA. À LA VERTICALE, LA GROSSEUR DES LINTEAUX D'ACIER AU-DESSUS DES OUVERTURES SERA DÉTERMINÉE PAR LE MAÇON.

98'-6"

1' - 0"

A109

98'-6"

7 1/2"

DESSUS DALLE ENTRÉE

E


IMPORTANT: SELON LE C.N.B. POUR LES ESCALIERS ART.8.8.2.2 - ÉCHAPÉE MESURER À PARTIR DU BORD EXTÉRIEUR DU NEZ DE MARCHE 1950 MM (77 PO) MIN. ART.9.8.8.4 - HAUTEUR GARDE-CORPS INTÉRIEUR DES LOGEMENTS ET SI MAX.71 PO AUDESSUS DU SOL 900 MM (36 PO DE HAUT) 1070 MM (41 PO DE HAUT) POUR PLUS DE 71 PO AU-DESSUS DU SOL. ART.9.8.8.5 - OUVERTURES ENTRE LES BAROTINS 100 MM MAX(4 PO) ENTRE LES BAROTINS. ART 9.8.7.1 - MAINS COURANTES EXIGÉES UNE MAIN COURANTE DOIT ÊTRE INSTALLÉE SUR AU MOINS 1 CÔTÉ D'UN ESCALIER. SUR LES 2 CÔTÉS POUR UN ESCALIER TOURNANT.

www.emsom.qc.ca 70' - 0"

ART 9.8.7.4 - HAUTEUR DES MAINS COURANTES DOIVENT AVOIR UNE HAUTEUR D'AU MOINS 800 MM ET D'AU PLUS 965 MM (30 À 34 PO DE HAUT).

35' - 0"

35' - 0"

15' - 0"

SELON LE C.N.B. POUR NORMES INCENDIES

12' - 11"

13' - 0"

PRÉVOIR UN DÉTECTEUR DE FUMÉE À L'ÉTAGE, DANS TOUS LES CHAMBRES (OU À MOINS DE 16'-0" DE LA PORTE DE DE CELLE-CI DANS UN CORRIDOR). L'INSATALLATION SERA CONFORME AU CNB DU QUÉBEC

2' - 0"

7' - 1"

6' - 0"

5' - 0"

7' - 1"

6' - 2"

2' - 10"

12' - 11"

2' - 10"

6' - 2"

15' - 0"

5' - 0"

6' - 0"

2' - 0"

NOTES GÉNÉRALES

13' - 0"

L'ENTREPENEUR DOIT:

D

A108

A109

PATIO

PATIO

10'-0" X 4'-4"

10'-0" X 4'-4"

1' - 0"

4

2

2

1

1

HAUT

3

10' - 0" 17' - 6 1/2" 4' - 8"

GARAGE 14'-4" X 18'-8"

3' - 0"

HAUT

1

48" X 80"

SALLE DE SÉJOUR 11'-0" X 15'-0"

48" X 80"

4' - 5"

12' - 10"

FOSSE DE RETENUE

2

CHOISIR LA FLEXIBILITÉ DES POUTRELLES EN FONCTION DES REVÊTEMENTS DE PLANCHER, VOIR CLIENT. DOUBLER LES POUTRELLES AU POURTOUR DES PUITS D'ESCALIER.

1

52" X 82"

52" X 82"

64" X 72"

32" X 72"

+ IMPOSTE (VOIR ÉLÉVATION)

+ IMPOSTE (VOIR ÉLÉVATION)

FENÊTRE FIXE

FENÊTRE AUVENT

2' - 8"

4' - 8"

8' - 0"

MAISON MULTIFAMILIALE

8'-0" X 4'-4"

4' - 0"

POUTRE 3-2"X10" ENCASTRÉE

8" 8"

4' - 0"

20' - 0"

8' - 0"

4' - 8" 20' - 0"

70' - 0"

2' - 8"

7' - 7 1/2"

7' - 4 5/8" 15' - 0"

PRÉVOIR UN CONDUIT POUR CHARGER UN FUTUR VÉHICULE ÉLÉCTRIQUE DANS LE GARAGE OU PRÈS DE L'AIRE DE STATIONNEMENT

Plan du Rez-de-Chaussée 0001

Numéro de projet Date

PLAN DU REZ-DE-CHAUSSÉE ÉCHELLE : 1/4" = 1'-0"

Dessiné par Vérifié par

Novembre 2018 Cindy Okino Nathalie Martel

A103 Echelle

1/4" = 1'-0"

2018-12-05 09:49:10

7' - 7 1/2"

MUR DE MACONNERIE -DANS UN MUR DE MACONNERIE, LES ATTACHES DE MÉTAL SERONT ESPACÉES DE 3'-0" MAX. À L'HORIZONTALE ET À 16" MA. À LA VERTICALE, LA GROSSEUR DES LINTEAUX D'ACIER AU-DESSUS DES OUVERTURES SERA DÉTERMINÉE PAR LE MAÇON.

PERRON

POTEAU 3-2"X4"

15' - 0"

SE RÉFÉRER AU PLAN DE TOITURE FOURNI PAR LE FABRICANT DES FERMES DE TOIT POUR L'EMPLACEMENT EXACT DES APPUIS ET DES POUTRES ET/OU DES FERMES MAÎTRESSES.

10'-0" X 7'-2"

SOLIVES 2"X6" @ 12" c/c

8'-0" X 4'-4"

7' - 4 5/8"

LE BOIS UTILISÉS À LA FABRICATION DES FERMES PRÉFABRIQUÉES DOIVENT ÊTRE CONFORMES À LA NORME CAN3-086 ET AU CODE NATIONAL DU BÂTIMENT DU CANADA.

2' - 9 1/2"

64" X 72" FENÊTRE FIXE

PERRON

FERMES DE TOIT

4' - 0"

4' - 0"

32" X 72" FENÊTRE AUVENT

SOLIVES 2"X6" @ 12" c/c

PLANCHERS POUTRELLES:

HAUT

4' - 8"

2' - 9"

POTEAU 3-2"X6" TYPE

BOIS: LE BOIS UTILISÉ SERA DE L'ÉPINETTE, DE GRADE #1 OU MEILLEUR.

POUTRES: LA POUTRE AU SOUS-SOL DE TYPE W EN ACIER SERA À CALCULER ET VÉRIFIER PAR FABRICANT.

32" X 80"

POTEAU DE BOIS D'INGÉNIERIE POUR CHARGE DE 7900 lbs (VOIR FABRICANT)

2

EMPATTEMENT: LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉ SELON LA NATURE DU SOL. VÉRIFIÉ PAR INGÉNIEUR.

POTEAUX TYPES: LES POTEAUX DANS LES MURS EXTÉRIEURES DOIVENT ÊTRE MIN 3-2"X6 SAUF INDICATION CONTRAIRE.

8' - 8"

2" REF.

10'-0" X 7'-2"

40' - 4"

5' - 4"

FENÊTRE AUVENT

32" X 72" 48" X 20"

6' - 4"

COMPTOIR LUNCH

FENÊTRE AUVENT

DISPOSITIF D'INTÉRRUPTION TEMPORAIRE

GARDE-MANGER

TOUTES LES STRUCTURES DOIVENT ÊTRE VÉRIFIÉES ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURES.

MUR EN 2"X6" POUR PLOMBERIE

1

2' - 9"

NOTES STRUCTURES: 32" X 80"

LAVE-VAISSELLE

POUTRE DE BOIS D'INGÉNIÉRIE ENCASTRÉE DANS LE PLANCHER TYPE (VOIR FABRICANT)

2

4' - 5"

-LES PARE-VAPEURS MENTIONNÉS AUX PLANS DEVRONT ÊTRE SCELLÉS LORSQU'ILS SERONT SUPERPOSÉS ET AUTOUR DES OUVERTURES.IL EST IMPORTANT D'INSTALLER UN PARE-VAPEUR À L'ARRIÈRE DES BOITES ÉLECTRIQUES ET DE LE SCELLER.

LES POTEAUX DANS LES MURS INTÉRIEURS DOIVENT ÊTRE MIN 3-2"X4" SAUF INDICATION CONTRAIRE.

1' - 2"

5' - 2"

11'-0" X 15'-0"

E

PRÉVOIR UN CONDUIT POUR CHARGER UN FUTUR VÉHICULE ÉLÉCTRIQUE DANS LE GARAGE OU PRÈS DE L'AIRE DE STATIONNEMENT

3' - 4"

HAUT

SALLE DE SÉJOUR

A109

LINGERIE 14"

3' - 10"

10' - 0"

A A108

CHAUFE-EAU

5

3' - 10"

3

-LES DIMENSIONS DES FENÊTRES AU PLAN PEUVENT VARIER SELON LE FABRICANT CHOISI, LES FENÊTRES DOIVENT RESPECTER LA NORME NORD-AMÉRICAINE (AAMA/WDMA/CSA), LA CATÉGORIE R EST LE NIVEAU DE CLASSIFICATION MINIMUM ACCEPTÉ.

6' - 8 1/2"

6

-LA PROFONDEUR MINIMALE DES FONDATIONS EN-DESSOUS DU NIVEAU DU SOL FINI EST DE 4'-6".CETTE PROFONDEUR PEUT VARIER SELON LES RÉGIONS ET LE CODE EN VIGUEUR. -IL EST OBLIGATOIRE DE VENTILER ADÉQUATEMENT LA TOITURE. LES VENTILATEURS CHOISIS PAR LE CLIENT ET/OU L'ENTREPRENEUR DEVRONT RESPECTER LE CODE EN VIGUEUR.

14' - 1 1/4"

6

REF.

-LE BÉTON UTILISÉ DOIT ÊTRE PRODUIT ET LIVRÉ PAR UNE USINE DÉTENANT UN CERTIFICAT DE CONFORMITÉ.

13' - 3 1/2"

7

PRÉVOIR UN MAÎTRE ÉLECTRICIEN POUR L'INSTALLATION ÉLECTRIQUE.

11' - 6 3/4"

8

7

12'-0" X 12'-0"

TOUTES LES STRUCTURES DEVRONT ÊTRES VÉRIFIÉS ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURE.

PRÉVOIR UN PLOMBIER CERTIFIÉ POUR L'INSTALLATION DE LA TUYAUTERIE.

5' - 8"

CUISINE DINETTE

RANGEMENT

8

POTEAU 3-2"X4"

9' - 10"

2

LAVEUSE

28" X 80"

28" X 80"

ÉCHANGEUR D'AIR

3' - 0"

DÉTECTEUR DE MONOXYDE DE CARBONE

DRAIN

ÉCHANGEUR D'AIR

4

12'-0" X 11'-4"

DÉTECTEUR DE FUMÉE ÉLECTRIQUE TYPE

STRUCTURE DU PLANCHER REINFORCÉ AUTOUR DU PUITS D'ÉSCALIER

GARDE-CORPS 3'-0" MIN.

VANITÉ 22" X 36"

32" X 80"

32" X 80"

VANITÉ 22" X 36"

STRUCTURE DU PLANCHER REINFORCÉ AUTOUR DU PUITS D'ÉSCALIER

ASPIRATEUR CENTRAL

5

3' - 2"

SALLE À MANGER

POTEAU DE BOIS D'INGÉNIERIE POUR CHARGE DE 8500 lbs (VOIR FABRICANT)

POTEAU 3-2"X4"

POTEAU DE BOIS D'INGÉNIERIE POUR CHARGE DE 7900 lbs (VOIR FABRICANT)

POUTRELLES 12" DE HAUT (VOIR FABRICANT)

11' - 6 3/4"

6'-3" X 5'-6"

DRAIN

6' - 3"

32" X 80"

2' - 9 1/2"

SALLE D'EAU

ASPIRATEUR CENTRAL

15' - 2"

MUR EN 2"X6" POUR PLOMBERIE

L'ENTREPRENEUR OU MAITRE D'OEUVRE AVANT D'ENTREPRENDRE LES TRAVAUX DEVRA MESURER SUR PLACE ET COORDONNER TOUT LES NIVEAUX, TOUTES LES PENTES ET TOUTES LES DIMENSIONS SUR LE CHANTIER AVANT L'ÉXÉCUTION DES TRAVAUX.

VENTILATEUR

3' - 4"

5' - 7" 6' - 10"

18' - 8"

DÉTECTEUR DE FUMÉE ÉLECTRIQUE TYPE

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS.

NOTES IMPORTANTES:

32" X 80"

DISPOSITIF D'INTÉRRUPTION TEMPORAIRE

HAUT

1

72" X 82"

CHUTE À LINGE

SÉCHEUSE

LAVEUSE SÉCHEUSE

11' - 10"

LINGERIE 14"

6' - 0" 11' - 10"

GARDE-MANGER

5' - 10"

RANGEMENT

3' - 0"

DÉTECTEUR DE MONOXYDE DE CARBONE

POUTRELLES 12" DE HAUT (VOIR FABRICANT)

40' - 4"

15' - 4 3/4" 20' - 0"

C A109

VENTILATEUR

1' - 1"

FOSSE DE RETENUE

6'-3" X 5'-2"

MUR EN 2"X6" POUR PLOMBERIE

6'-3" X 5'-6"

11'-0" X 12'-4"

GARAGE

SALLE DE LAVAGE

6'-3" X 5'-2"

SALLE D'EAU

SALLE À MANGER

14'-4" X 18'-8"

32" X 72"

LINTEAU DE BOIS D'INGÉNIERIE (VOIR FABRICANT)

32" X 80"

POTEAU DE BOIS D'INGÉNIERIE POUR CHARGE DE 8500 lbs (VOIR FABRICANT)

32" X 80"

SALLE DE LAVAGE

CHAUFE-EAU

3' - 0"

FENÊTRE AUVENT

32" X 72"

5' - 8"

12'-0" X 11'-4"

COMPTOIR LUNCH

17' - 6 1/2"

CUISINIÈRE + VENTILATEUR

13' - 4 1/2"

*SORTIE POUR APPAREIL MÉNAGER À COORDONNER SUR PLACE.

CUISINE DINETTE LAVE-VAISSELLE

REF.

*SORTIE POUR HOTTE DE CUISINIÈRE À COORDONNER SUR PLACE.

POUTRELLES 12" DE HAUT (VOIR FABRICANT)

À NOTER

PRÉVOIR PANNEAU ÉLECTRIQUE 200 AMP.

20" X 56"

8"

POUTRELLES 12" DE HAUT (VOIR FABRICANT)

20" X 56"

POUTRELLES 12" DE HAUT (VOIR FABRICANT)

32" X 72"

-LES COTES ET LES DIMENSIONS ONT PRIORITÉ SUR LES DESSINS CERTAINES COTES SONT SUJETTES À UN AJUSTEMENT EN FONCTIONS DES MATÉRIAUX ET/OU MÉTHODES CHOISIS PAR L'ENTREPRENEUR. - SI L'ENTREPRENEUR VENAIT À CONSTATER DES DIFFÉRENCES ENTRE LE CHANTIER ET LE PRÉSENT PLAN, IL EST INVITÉ À CONTACTER LE RESPONSABLE DES PLANS DANS LES PLUS BREFS DÉLAIS.

GARDE-CORPS 3'-0" MIN.

POUTRELLES 12" DE HAUT (VOIR FABRICANT)

72" X 82" LINTEAU DE BOIS D'INGÉNIERIE (VOIR FABRICANT)

*SYSTÈME ÉCHANGEUR D'AIR OBLIGATOIRE DEPUIS 2012 ENTRÉE ET SORTIE POUR ÉCHANGEUR D'AIR À COORDONNER SUR PLACE

1) VÉRIFIER TOUTES LES DIMENSIONS AVANT DE DÉBUTER LES TRAVAUX. 2) RESPECTER S'IL Y A LIEU TOUTES LES EXIGENCES DES DOCUMENTS CONNEXES AU PLANS ET INFORMER LE CLIENT DE TOUTES CONSÉQUENCES DUES AUX CHANGEMENTS QUI SERONT APPORTÉS AUX PLANS.

GARDE-CORPS 3'-0" MIN.

GARDE-CORPS 3'-0" MIN.

B

HAUT

ENTRÉE EN VIGUEUR AU CODE DU CNB 2010 MODIFIÉ UN AVERTISSEUR DE FUMÉE DOIT ÊTRE INSTALLÉ DANS CHAQUE PIÈCE OÙ L'ON DORT (1X CHAMBRE) AINSI QUE UN PAR ÉTAGE DANS LES CORRIDORS INCLUANT LE SOUS-SOL. UN DÉTECTEUR DE MONOXYDE DE CARBONE (CO) EST REQUIS S'IL Y A UN FOYER AU GAZ OU AU BOIS OU UN GARAGE ANNEXÉ À LA MAISON.UN DÉTECTEUR COMBINÉ EST AUTORISÉ IL DOIT ÊTRE SITUÉ DANS LE CORRIDOR À MOINS DE 5 M DES CHAMBRES À COUCHER.(VOIR ARTICLE 9.32.3.9 DU CNB).


IMPORTANT: SELON LE C.N.B. POUR LES ESCALIERS ART.8.8.2.2 - ÉCHAPÉE MESURER À PARTIR DU BORD EXTÉRIEUR DU NEZ DE MARCHE 1950 MM (77 PO) MIN. ART.9.8.8.4 - HAUTEUR GARDE-CORPS INTÉRIEUR DES LOGEMENTS ET SI MAX.71 PO AUDESSUS DU SOL 900 MM (36 PO DE HAUT) 1070 MM (41 PO DE HAUT) POUR PLUS DE 71 PO AU-DESSUS DU SOL. ART.9.8.8.5 - OUVERTURES ENTRE LES BAROTINS 100 MM MAX(4 PO) ENTRE LES BAROTINS. ART 9.8.7.1 - MAINS COURANTES EXIGÉES UNE MAIN COURANTE DOIT ÊTRE INSTALLÉE SUR AU MOINS 1 CÔTÉ D'UN ESCALIER. SUR LES 2 CÔTÉS POUR UN ESCALIER TOURNANT.

www.emsom.qc.ca

ART 9.8.7.4 - HAUTEUR DES MAINS COURANTES DOIVENT AVOIR UNE HAUTEUR D'AU MOINS 800 MM ET D'AU PLUS 965 MM (30 À 34 PO DE HAUT).

40' - 0" 20' - 0"

20' - 0" 10' - 8" 5' - 1"

32" X 42"

32" X 42"

(LOI EGRESS)

(LOI EGRESS)

LINTEAU DE BOIS D'INGÉNIERIE (VOIR FABRICANT)

D

A108

A109

10' - 7"

32" X 42"

PRÉVOIR UN MAÎTRE ÉLECTRICIEN POUR L'INSTALLATION ÉLECTRIQUE.

18' - 10"

30" X 80"

3' - 2"

12

3' - 10"

15' - 2"

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

3

2

2

3' - 10"

1' - 4"

3' - 8"

" -8

2' - 4"

CHAMBRE # 2 10,-4" X 10'-8"

5' - 6"

WALK-IN

9' - 10"

30" X 80"

PLANCHERS POUTRELLES:

FERMES DE TOIT LE BOIS UTILISÉS À LA FABRICATION DES FERMES PRÉFABRIQUÉES DOIVENT ÊTRE CONFORMES À LA NORME CAN3-086 ET AU CODE NATIONAL DU BÂTIMENT DU CANADA. SE RÉFÉRER AU PLAN DE TOITURE FOURNI PAR LE FABRICANT DES FERMES DE TOIT POUR L'EMPLACEMENT EXACT DES APPUIS ET DES POUTRES ET/OU DES FERMES MAÎTRESSES.

7' - 8"

60" X 80"

14'-0" X 12'-0"

MUR DE MACONNERIE -DANS UN MUR DE MACONNERIE, LES ATTACHES DE MÉTAL SERONT ESPACÉES DE 3'-0" MAX. À L'HORIZONTALE ET À 16" MA. À LA VERTICALE, LA GROSSEUR DES LINTEAUX D'ACIER AU-DESSUS DES OUVERTURES SERA DÉTERMINÉE PAR LE MAÇON.

32" X 42"

64" X 16"

18" X 42"

18" X 42"

64" X 16"

32" X 42"

(LOI EGRESS)

(LOI EGRESS)

(LOI EGRESS)

(LOI EGRESS)

(LOI EGRESS)

(LOI EGRESS)

8' - 5 7/8" 14' - 10"

4' - 2 1/4"

4' - 2 1/4"

5' - 2"

8' - 5 7/8"

4' - 8"

5' - 2"

20' - 0"

MAISON MULTIFAMILIALE

2' - 8"

14' - 10" 20' - 0"

40' - 0"

Plan de l'Étage PLAN DE L'ÉTAGE ÉCHELLE : 1/4" = 1'-0"

0001

Numéro de projet Date Dessiné par Vérifié par

Novembre 2018 Cindy Okino Nathalie Martel

A104 Echelle

1/4" = 1'-0"

2018-12-05 10:08:27

4' - 8"

POUTRES: LA POUTRE AU SOUS-SOL DE TYPE W EN ACIER SERA À CALCULER ET VÉRIFIER PAR FABRICANT.

CHOISIR LA FLEXIBILITÉ DES POUTRELLES EN FONCTION DES REVÊTEMENTS DE PLANCHER, VOIR CLIENT. DOUBLER LES POUTRELLES AU POURTOUR DES PUITS D'ESCALIER.

POTEAU 3-2"X6" TYPE

2' - 8"

EMPATTEMENT: LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉ SELON LA NATURE DU SOL. VÉRIFIÉ PAR INGÉNIEUR.

LES POTEAUX DANS LES MURS INTÉRIEURS DOIVENT ÊTRE MIN 3-2"X4" SAUF INDICATION CONTRAIRE.

11' - 2"

CHAMBRE # 1

A109

TOUTES LES STRUCTURES DOIVENT ÊTRE VÉRIFIÉES ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURES.

POTEAUX TYPES: LES POTEAUX DANS LES MURS EXTÉRIEURES DOIVENT ÊTRE MIN 3-2"X6 SAUF INDICATION CONTRAIRE.

4'-6" X 8'-8"

4'-6" X 6'-6"

NOTES STRUCTURES:

BOIS: LE BOIS UTILISÉ SERA DE L'ÉPINETTE, DE GRADE #1 OU MEILLEUR.

WALK-IN

14'-0" X 12'-0"

E

6' - 1"

30" X 80"

17' - 7"

CHAMBRE # 1 A108

1' - 7"

3' - 8"

ACCÈS À L'ATIQUE 22" X 30"

A

3' - 6"

1'

30" X 80"

5' - 2"

-LES DIMENSIONS DES FENÊTRES AU PLAN PEUVENT VARIER SELON LE FABRICANT CHOISI, LES FENÊTRES DOIVENT RESPECTER LA NORME NORD-AMÉRICAINE (AAMA/WDMA/CSA), LA CATÉGORIE R EST LE NIVEAU DE CLASSIFICATION MINIMUM ACCEPTÉ. -LES PARE-VAPEURS MENTIONNÉS AUX PLANS DEVRONT ÊTRE SCELLÉS LORSQU'ILS SERONT SUPERPOSÉS ET AUTOUR DES OUVERTURES.IL EST IMPORTANT D'INSTALLER UN PARE-VAPEUR À L'ARRIÈRE DES BOITES ÉLECTRIQUES ET DE LE SCELLER.

30" X 80"

1 MUR EN 2"X6" POUR PLOMBERIE

-IL EST OBLIGATOIRE DE VENTILER ADÉQUATEMENT LA TOITURE. LES VENTILATEURS CHOISIS PAR LE CLIENT ET/OU L'ENTREPRENEUR DEVRONT RESPECTER LE CODE EN VIGUEUR.

2' - 4"

13

12

30" X 80"

14

13

21' - 6"

28" X 80"

OUVERT SUR LE RDC

GARDE-CORPS 3'-0" MIN.

32" X 40"

VANITÉ 22" X 78"

DOUCHE 51" X 34"

14

-LA PROFONDEUR MINIMALE DES FONDATIONS EN-DESSOUS DU NIVEAU DU SOL FINI EST DE 4'-6".CETTE PROFONDEUR PEUT VARIER SELON LES RÉGIONS ET LE CODE EN VIGUEUR.

60" X 80"

13' - 2"

11' - 11"

30" X 80"

VENTILATEUR

15

11

8'-6" X 11'-6"

30" X 80"

OUVERT SUR LE RDC

3' - 8"

15

11' - 10"

9' - 4"

SALLE DE BAIN

DÉTECTEUR DE MONOXYDE DE CARBONE

3' - 10"

2' - 9"

-LE BÉTON UTILISÉ DOIT ÊTRE PRODUIT ET LIVRÉ PAR UNE USINE DÉTENANT UN CERTIFICAT DE CONFORMITÉ.

GARDE-CORPS 3'-0" MIN.

7' - 11"

PRÉVOIR UN PLOMBIER CERTIFIÉ POUR L'INSTALLATION DE LA TUYAUTERIE.

60" X 80"

BAS

3' - 6"

BAS

5' - 10"

3' - 10"

2' - 4"

DÉTECTEUR DE MONOXYDE DE CARBONE

TOUTES LES STRUCTURES DEVRONT ÊTRES VÉRIFIÉS ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURE.

10,-4" X 10'-8"

40' - 4"

22' - 9"

DOUCHE 51" X 34"

BAIGNOIRE 60" X 30"

13' - 3"

CHAMBRE # 3

VENTILATEUR 30" X 80"

50" X 80"

DÉTECTEUR DE FUMÉE ÉLECTRIQUE TYPE

40' - 4"

MUR EN 2"X6" POUR PLOMBERIE

L'ENTREPRENEUR OU MAITRE D'OEUVRE AVANT D'ENTREPRENDRE LES TRAVAUX DEVRA MESURER SUR PLACE ET COORDONNER TOUT LES NIVEAUX, TOUTES LES PENTES ET TOUTES LES DIMENSIONS SUR LE CHANTIER AVANT L'ÉXÉCUTION DES TRAVAUX.

11' - 6"

6' - 10"

8'-1" X 10'-8"

4' - 8"

10'-1" X 10'-8"

NOTES IMPORTANTES:

SALLE DE BAIN

4' - 7"

CHAMBRE # 3

8'-6" X 12'-0"

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS.

PANNEAU ÉLECTRIQUE

30" X 80"

12' - 10"

CHAMBRE # 2

-LES COTES ET LES DIMENSIONS ONT PRIORITÉ SUR LES DESSINS CERTAINES COTES SONT SUJETTES À UN AJUSTEMENT EN FONCTIONS DES MATÉRIAUX ET/OU MÉTHODES CHOISIS PAR L'ENTREPRENEUR. - SI L'ENTREPRENEUR VENAIT À CONSTATER DES DIFFÉRENCES ENTRE LE CHANTIER ET LE PRÉSENT PLAN, IL EST INVITÉ À CONTACTER LE RESPONSABLE DES PLANS DANS LES PLUS BREFS DÉLAIS.

LINTEAU DE BOIS D'INGÉNIERIE (VOIR FABRICANT)

ACCÈS À L'ATTIQUE 22" X 30"

C

*SORTIE POUR APPAREIL MÉNAGER À COORDONNER SUR PLACE.

1) VÉRIFIER TOUTES LES DIMENSIONS AVANT DE DÉBUTER LES TRAVAUX. 2) RESPECTER S'IL Y A LIEU TOUTES LES EXIGENCES DES DOCUMENTS CONNEXES AU PLANS ET INFORMER LE CLIENT DE TOUTES CONSÉQUENCES DUES AUX CHANGEMENTS QUI SERONT APPORTÉS AUX PLANS.

32" X 42"

BAIGNOIRE 60" X 30"

A109

*SORTIE POUR HOTTE DE CUISINIÈRE À COORDONNER SUR PLACE.

L'ENTREPENEUR DOIT:

(LOI EGRESS)

6' - 11"

*SYSTÈME ÉCHANGEUR D'AIR OBLIGATOIRE DEPUIS 2012 ENTRÉE ET SORTIE POUR ÉCHANGEUR D'AIR À COORDONNER SUR PLACE PRÉVOIR PANNEAU ÉLECTRIQUE 200 AMP.

4' - 4"

CHUTE À LINGE

PANNEAU ÉLECTRIQUE

À NOTER

B

NOTES GÉNÉRALES

11' - 2"

5' - 1"

VANITÉ 22" X 78"

ENTRÉE EN VIGUEUR AU CODE DU CNB 2010 MODIFIÉ UN AVERTISSEUR DE FUMÉE DOIT ÊTRE INSTALLÉ DANS CHAQUE PIÈCE OÙ L'ON DORT (1X CHAMBRE) AINSI QUE UN PAR ÉTAGE DANS LES CORRIDORS INCLUANT LE SOUS-SOL. UN DÉTECTEUR DE MONOXYDE DE CARBONE (CO) EST REQUIS S'IL Y A UN FOYER AU GAZ OU AU BOIS OU UN GARAGE ANNEXÉ À LA MAISON.UN DÉTECTEUR COMBINÉ EST AUTORISÉ IL DOIT ÊTRE SITUÉ DANS LE CORRIDOR À MOINS DE 5 M DES CHAMBRES À COUCHER.(VOIR ARTICLE 9.32.3.9 DU CNB).

10' - 7"

11' - 0"

4' - 4"

8' - 10"

32" X 42"

9' - 4"

PRÉVOIR UN DÉTECTEUR DE FUMÉE À L'ÉTAGE, DANS TOUS LES CHAMBRES (OU À MOINS DE 16'-0" DE LA PORTE DE DE CELLE-CI DANS UN CORRIDOR). L'INSATALLATION SERA CONFORME AU CNB DU QUÉBEC

(LOI EGRESS)

SELON LE C.N.B. POUR NORMES INCENDIES


IMPORTANT: SELON LE C.N.B. POUR LES ESCALIERS ART.8.8.2.2 - ÉCHAPÉE MESURER À PARTIR DU BORD EXTÉRIEUR DU NEZ DE MARCHE 1950 MM (77 PO) MIN. ART.9.8.8.4 - HAUTEUR GARDE-CORPS INTÉRIEUR DES LOGEMENTS ET SI MAX.71 PO AUDESSUS DU SOL 900 MM (36 PO DE HAUT) 1070 MM (41 PO DE HAUT) POUR PLUS DE 71 PO AU-DESSUS DU SOL. ART.9.8.8.5 - OUVERTURES ENTRE LES BAROTINS 100 MM MAX(4 PO) ENTRE LES BAROTINS. ART 9.8.7.1 - MAINS COURANTES EXIGÉES UNE MAIN COURANTE DOIT ÊTRE INSTALLÉE SUR AU MOINS 1 CÔTÉ D'UN ESCALIER. SUR LES 2 CÔTÉS POUR UN ESCALIER TOURNANT.

www.emsom.qc.ca

ART 9.8.7.4 - HAUTEUR DES MAINS COURANTES DOIVENT AVOIR UNE HAUTEUR D'AU MOINS 800 MM ET D'AU PLUS 965 MM (30 À 34 PO DE HAUT).

SELON LE C.N.B. POUR NORMES INCENDIES

NOTES GÉNÉRALES

PRÉVOIR UN DÉTECTEUR DE FUMÉE À L'ÉTAGE, DANS TOUS LES CHAMBRES (OU À MOINS DE 16'-0" DE LA PORTE DE DE CELLE-CI DANS UN CORRIDOR). L'INSATALLATION SERA CONFORME AU CNB DU QUÉBEC

L'ENTREPENEUR DOIT:

70' - 0" 15' - 0"

ENTRÉE EN VIGUEUR AU CODE DU CNB 2010 MODIFIÉ UN AVERTISSEUR DE FUMÉE DOIT ÊTRE INSTALLÉ DANS CHAQUE PIÈCE OÙ L'ON DORT (1X CHAMBRE) AINSI QUE UN PAR ÉTAGE DANS LES CORRIDORS INCLUANT LE SOUS-SOL. UN DÉTECTEUR DE MONOXYDE DE CARBONE (CO) EST REQUIS S'IL Y A UN FOYER AU GAZ OU AU BOIS OU UN GARAGE ANNEXÉ À LA MAISON.UN DÉTECTEUR COMBINÉ EST AUTORISÉ IL DOIT ÊTRE SITUÉ DANS LE CORRIDOR À MOINS DE 5 M DES CHAMBRES À COUCHER.(VOIR ARTICLE 9.32.3.9 DU CNB).

20' - 0"

20' - 0"

B

D

A108

A109

1) VÉRIFIER TOUTES LES DIMENSIONS AVANT DE DÉBUTER LES TRAVAUX. 2) RESPECTER S'IL Y A LIEU TOUTES LES EXIGENCES DES DOCUMENTS CONNEXES AU PLANS ET INFORMER LE CLIENT DE TOUTES CONSÉQUENCES DUES AUX CHANGEMENTS QUI SERONT APPORTÉS AUX PLANS.

15' - 0"

-LES COTES ET LES DIMENSIONS ONT PRIORITÉ SUR LES DESSINS CERTAINES COTES SONT SUJETTES À UN AJUSTEMENT EN FONCTIONS DES MATÉRIAUX ET/OU MÉTHODES CHOISIS PAR L'ENTREPRENEUR. - SI L'ENTREPRENEUR VENAIT À CONSTATER DES DIFFÉRENCES ENTRE LE CHANTIER ET LE PRÉSENT PLAN, IL EST INVITÉ À CONTACTER LE RESPONSABLE DES PLANS DANS LES PLUS BREFS DÉLAIS.

PANNEAU DE BÉTON LÉGER SOUS LA CORNICHE ET FIXER AU FERME DE TOIT DE CHAQUE CÔTÉ POUR SUPPORTER LA LAINE.

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS.

À NOTER

NOTES IMPORTANTES:

*SYSTÈME ÉCHANGEUR D'AIR OBLIGATOIRE DEPUIS 2012 ENTRÉE ET SORTIE POUR ÉCHANGEUR D'AIR À COORDONNER SUR PLACE

L'ENTREPRENEUR OU MAITRE D'OEUVRE AVANT D'ENTREPRENDRE LES TRAVAUX DEVRA MESURER SUR PLACE ET COORDONNER TOUT LES NIVEAUX, TOUTES LES PENTES ET TOUTES LES DIMENSIONS SUR LE CHANTIER AVANT L'ÉXÉCUTION DES TRAVAUX.

PRÉVOIR PANNEAU ÉLECTRIQUE 200 AMP.

AUCUNE VENTILATION PERMISE ENTRE LES DEUX LOGEMENTS, REMPLIR LES CAVITÉS DE LAINE ET L'ENCLOISONNER DE PANNEAU DE BÉTON LÉGER.

*SORTIE POUR HOTTE DE CUISINIÈRE À COORDONNER SUR PLACE. *SORTIE POUR APPAREIL MÉNAGER À COORDONNER SUR PLACE.

TOUTES LES STRUCTURES DEVRONT ÊTRES VÉRIFIÉS ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURE. PRÉVOIR UN MAÎTRE ÉLECTRICIEN POUR L'INSTALLATION ÉLECTRIQUE. PRÉVOIR UN PLOMBIER CERTIFIÉ POUR L'INSTALLATION DE LA TUYAUTERIE.

C A109

-LE BÉTON UTILISÉ DOIT ÊTRE PRODUIT ET LIVRÉ PAR UNE USINE DÉTENANT UN CERTIFICAT DE CONFORMITÉ. -LA PROFONDEUR MINIMALE DES FONDATIONS EN-DESSOUS DU NIVEAU DU SOL FINI EST DE 4'-6".CETTE PROFONDEUR PEUT VARIER SELON LES RÉGIONS ET LE CODE EN VIGUEUR.

17' - 6 1/2"

17' - 6 1/2"

ARRÊTER LE MUR MITOYEN SOUS LA SOUS-FACE DU CONTREPLAQUÉ DE TOITURE.

FERMES (VOIR FABRICANT)

-IL EST OBLIGATOIRE DE VENTILER ADÉQUATEMENT LA TOITURE. LES VENTILATEURS CHOISIS PAR LE CLIENT ET/OU L'ENTREPRENEUR DEVRONT RESPECTER LE CODE EN VIGUEUR. -LES DIMENSIONS DES FENÊTRES AU PLAN PEUVENT VARIER SELON LE FABRICANT CHOISI, LES FENÊTRES DOIVENT RESPECTER LA NORME NORD-AMÉRICAINE (AAMA/WDMA/CSA), LA CATÉGORIE R EST LE NIVEAU DE CLASSIFICATION MINIMUM ACCEPTÉ.

FERMES (VOIR FABRICANT)

-LES PARE-VAPEURS MENTIONNÉS AUX PLANS DEVRONT ÊTRE SCELLÉS LORSQU'ILS SERONT SUPERPOSÉS ET AUTOUR DES OUVERTURES.IL EST IMPORTANT D'INSTALLER UN PARE-VAPEUR À L'ARRIÈRE DES BOITES ÉLECTRIQUES ET DE LE SCELLER.

NOTES STRUCTURES: TOUTES LES STRUCTURES DOIVENT ÊTRE VÉRIFIÉES ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURES. EMPATTEMENT: LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉ SELON LA NATURE DU SOL. VÉRIFIÉ PAR INGÉNIEUR.

FERME RENFORCÉE (VOIR FABRICANT)

FERME RENFORCÉE (VOIR FABRICANT)

FERME RENFORCÉE (VOIR FABRICANT)

40' - 4"

40' - 4"

FERME RENFORCÉE (VOIR FABRICANT)

FERMES (VOIR FABRICANT)

VENTILATEUR D'ENTRETOIT

BOIS: LE BOIS UTILISÉ SERA DE L'ÉPINETTE, DE GRADE #1 OU MEILLEUR. POTEAUX TYPES: LES POTEAUX DANS LES MURS EXTÉRIEURES DOIVENT ÊTRE MIN 3-2"X6 SAUF INDICATION CONTRAIRE. LES POTEAUX DANS LES MURS INTÉRIEURS DOIVENT ÊTRE MIN 3-2"X4" SAUF INDICATION CONTRAIRE. POUTRES: LA POUTRE AU SOUS-SOL DE TYPE W EN ACIER SERA À CALCULER ET VÉRIFIER PAR FABRICANT.

FERMES

(VOIR FABRICANT)

CHOISIR LA FLEXIBILITÉ DES POUTRELLES EN FONCTION DES REVÊTEMENTS DE PLANCHER, VOIR CLIENT. DOUBLER LES POUTRELLES AU POURTOUR DES PUITS D'ESCALIER.

20' - 0"

FERMES (VOIR FABRICANT)

(VOIR FABRICANT)

FERMES (VOIR FABRICANT)

20' - 0"

PLANCHERS POUTRELLES:

FERMES

FERMES DE TOIT LE BOIS UTILISÉS À LA FABRICATION DES FERMES PRÉFABRIQUÉES DOIVENT ÊTRE CONFORMES À LA NORME CAN3-086 ET AU CODE NATIONAL DU BÂTIMENT DU CANADA. SE RÉFÉRER AU PLAN DE TOITURE FOURNI PAR LE FABRICANT DES FERMES DE TOIT POUR L'EMPLACEMENT EXACT DES APPUIS ET DES POUTRES ET/OU DES FERMES MAÎTRESSES.

2' - 0" TYPE

A

4' - 4"

A108

15' - 8"

15' - 8"

MUR DE MACONNERIE -DANS UN MUR DE MACONNERIE, LES ATTACHES DE MÉTAL SERONT ESPACÉES DE 3'-0" MAX. À L'HORIZONTALE ET À 16" MA. À LA VERTICALE, LA GROSSEUR DES LINTEAUX D'ACIER AU-DESSUS DES OUVERTURES SERA DÉTERMINÉE PAR LE MAÇON.

4' - 4"

E A109

2' - 9 1/2"

PENTE 3/8" SUR 12"

Plan de la Toiture

MEMBRANE (VOIR MANUFACTURIER)

15' - 0"

11' - 4"

8' - 8"

8' - 8" 70' - 0"

11' - 4"

15' - 0"

SE RÉFÉRER AU PLAN DE TOITURE FOURNI PAR LE FABRICANT DES FERMES DE TOIT POUR L'EMPLACEMENT EXACT DES APPUIS ET DES POUTRES ET/OU DES FERMES MAITRESSES

PLAN DE LA TOITURE ÉCHELLE : 1/4" = 1'-0"

0001

Numéro de projet Date Dessiné par Vérifié par

Novembre 2018 Cindy Okino Nathalie Martel

A105 Echelle

1/4" = 1'-0"

2018-12-05 10:24:30

PENTE 3/8" SUR 12"

MAISON MULTIFAMILIALE 4' - 4"

4' - 4"

2' - 9 1/2"

PANNEAU DE BÉTON LÉGER SOUS LA CORNICHE ET FIXER AU FERME DE TOIT DE CHAQUE CÔTÉ POUR SUPPORTER LA LAINE.


VENTILATEUR D'ENTRETOIT

12

12

5

5

6" TYPE

BARDEAUX D'ASPHALTE

www.emsom.qc.ca

DESSUS SABLIÈRE 2' - 0" TYPE

8' - 2"

FIXE

FIXE

NOTES GÉNÉRALES L'ENTREPENEUR DOIT:

FIXE

FIXE

12

ALLÈGE DE PIERRE 2" SOLIN TYPE

BARDEAUX D'ASPHALTE

6

1) VÉRIFIER TOUTES LES DIMENSIONS AVANT DE DÉBUTER LES TRAVAUX. 2) RESPECTER S'IL Y A LIEU TOUTES LES EXIGENCES DES DOCUMENTS CONNEXES AU PLANS ET INFORMER LE CLIENT DE TOUTES CONSÉQUENCES DUES AUX CHANGEMENTS QUI SERONT APPORTÉS AUX PLANS.

12 REVËTEMENT VINYLE

BRIQUE

6

MEMBRANES ELASTOMERES AUTOCOLLANTES

SOLIN + LINTEAU D'ACIER TYPE

DESSUS SABLIÈRE

-LES COTES ET LES DIMENSIONS ONT PRIORITÉ SUR LES DESSINS CERTAINES COTES SONT SUJETTES À UN AJUSTEMENT EN FONCTIONS DES MATÉRIAUX ET/OU MÉTHODES CHOISIS PAR L'ENTREPRENEUR. - SI L'ENTREPRENEUR VENAIT À CONSTATER DES DIFFÉRENCES ENTRE LE CHANTIER ET LE PRÉSENT PLAN, IL EST INVITÉ À CONTACTER LE RESPONSABLE DES PLANS DANS LES PLUS BREFS DÉLAIS.

6" TYPE

2' - 8"

BARDEAUX D'ASPHALTE TOLE D'ACIER PREPEINTE

DESSUS PLANCHER

DESSUS SABLIÈRE GARAGE

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS.

1' - 0"

2' - 0" TYPE

FIXE

FIXE ALLÈGE DE PIERRE 2" TYPE

FIXE

3. LINTEAUX AU DESSUS DES OUVERTURES 3.2"X12" INDIQUÉ SUR LES PLANS.

2' - 9"

DESSUS FONDATION

4. PROTECTION DES OUVERTURES: POUR UNE MEILLEURE PROTECTION ON RECOMMANDE L'UTILISATION DE MEMBRANES AUTOCOLLANTES CONFORMES À LA NORMES ASTM D 779 POUR LES JAMBAGES ET LE HAUT DE LA BAIE, EN PLUS DE CELLE REQUISE POUR LA LISSE D'APPUI. LES COINS DOIVENT ÉGALEMENT ÊTRE RENFORCÉS PAR UNE MEMBRANE DE COIN.

DESSUS FONDATION GARAGE

SOL FINI 8' - 0"

PRÉVOIR PENTE VERS L'EXTÉRIEUR SUR 10'-0" (MIN. 6")

SOL FINI 4' - 6"

6" MIN.

8" MIN.

5' - 2"

6' - 6"

PERRON

8' - 0"

1.LES DIMENSIONS DES PORTES ET FENÊTRES SONT À TITRE INDICATIF. L'ENTREPRENEUR DEVRA AVOIR LES DIMENSIONS EXACTES DU FOURNISSEUR AFIN DE FAIRE LES OUVERTURES EN CONSÉQUENCES. 2. LINTEAUX AU DESSUS DES OUVERTURES 2.2"X10" SAUF AVIS CONTRAIRE.

FIXE BLOCS ARCHITECTURAUX

1' - 4"

100' - 0"

OUVERTURES: 9' - 0"

8' - 8"

8' - 2"

7' - 0" TYPE

REVËTEMENT VINYLE

DESSUS EMPATTEMENTS

DESSUS EMPATTEMENTS

ÉLÉVATION AVANT ÉCHELLE : 1/4" = 1'-0"

VENTILATEUR D'ENTRETOIT

12

12

5

5

6" TYPE

BARDEAUX D'ASPHALTE

DESSUS SABLIÈRE 2' - 0" TYPE

6

FIXE

FIXE

FIXE

FIXE

12 BARDEAUX D'ASPHALTE

6

MAISON MULTIFAMILIALE

6" TYPE

BARDEAUX D'ASPHALTE

7' - 0" TYPE

8' - 2"

REVËTEMENT VINYLE

12

DESSUS PLANCHER DESSUS SABLIÈRE

DESSUS SABLIÈRE GARAGE 2' - 0" TYPE

Élévation Avant et Élévation Arrière

DESSUS FONDATION

DESSUS EMPATTEMENTS

6' - 8" PRÉVOIR UN APPUI POUR LES ESCALIERS ET AJUSTER LES CONTREMARCHES EN FONCTION DU TERRAIN.

Date

DESSUS EMPATTEMENTS

Dessiné par Vérifié par

Novembre 2018 Cindy Okino Nathalie Martel

A106

ÉLÉVATION ARRIÈRE ÉCHELLE : 1/4" = 1'-0"

Echelle

1/4" = 1'-0"

12/17/2018 8:58:09 PM

2 M. À 10" = 1'-8" 3 CM. À ± 7 5/6" = 1'-10"

SOL FINI 4' - 6"

6' - 8" PRÉVOIR UN APPUI POUR LES ESCALIERS ET AJUSTER LES CONTREMARCHES EN FONCTION DU TERRAIN.

DESSUS FONDATION GARAGE PRÉVOIR PENTE VERS L'EXTÉRIEUR SUR 10'-0" (MIN. 6")

6" MIN.

6' - 6"

2 M. À 10" = 1'-8" 3 CM. À ± 7 5/6" = 1'-10"

0001

Numéro de projet

2' - 0"

PATIO

SOL FINI

4' - 6" MIN.

100' - 0"

REVËTEMENT VINYLE

9' - 0"

8' - 2"

7' - 0" TYPE

GARDE-CORPS 3'-0" MIN.


VENTILATEUR D'ENTRETOIT

12

12

5

5

6" TYPE

BARDEAUX D'ASPHALTE

www.emsom.qc.ca

DESSUS SABLIÈRE

DESSUS SABLIÈRE 2' - 0" TYPE

NOTES GÉNÉRALES 12

6

ALLÈGE DE PIERRE 2" TYPE

8' - 2"

8' - 2"

12

6 FIXE BARDEAUX D'ASPHALTE

REVÊTEMENT VINYLE

DESSUS SABLIÈRE

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS.

4"

2' - 0" TYPE

FIXE

5' - 0"

BLOCS ARCHITECTURAUX BRIQUE 4"

OUVERTURES:

GARDE-CORPS 3'-0" MIN.

7' - 0" TYPE

9' - 0"

9' - 6"

MEMBRANES ELASTOMERES AUTOCOLLANTES

8' - 2"

TOLE D'ACIER PREPEINTE

1.LES DIMENSIONS DES PORTES ET FENÊTRES SONT À TITRE INDICATIF. L'ENTREPRENEUR DEVRA AVOIR LES DIMENSIONS EXACTES DU FOURNISSEUR AFIN DE FAIRE LES OUVERTURES EN CONSÉQUENCES. 2. LINTEAUX AU DESSUS DES OUVERTURES 2.2"X10" SAUF AVIS CONTRAIRE. 3. LINTEAUX AU DESSUS DES OUVERTURES 3.2"X12" INDIQUÉ SUR LES PLANS.

ALLÈGE DE PIERRE 2" TYPE

100' - 0"

4. PROTECTION DES OUVERTURES: POUR UNE MEILLEURE PROTECTION ON RECOMMANDE L'UTILISATION DE MEMBRANES AUTOCOLLANTES CONFORMES À LA NORMES ASTM D 779 POUR LES JAMBAGES ET LE HAUT DE LA BAIE, EN PLUS DE CELLE REQUISE POUR LA LISSE D'APPUI. LES COINS DOIVENT ÉGALEMENT ÊTRE RENFORCÉS PAR UNE MEMBRANE DE COIN.

SOL FINI PRÉVOIR PENTE VERS L'EXTÉRIEUR SUR 10'-0" (MIN. 6")

DESSUS EMPATTEMENTS

6' - 6"

2 M. À 10" = 1'-8" 3 CM. À ± 7 5/6" = 1'-10"

4' - 6" MIN.

5' - 2"

8" MIN.

SOL FINI

REVÊTEMENT VINYLE

6" MIN.

DESSUS DALLE ENTRÉE

2' - 0"

1' - 4"

DESSUS FONDATION 98' - 8"

1) VÉRIFIER TOUTES LES DIMENSIONS AVANT DE DÉBUTER LES TRAVAUX. 2) RESPECTER S'IL Y A LIEU TOUTES LES EXIGENCES DES DOCUMENTS CONNEXES AU PLANS ET INFORMER LE CLIENT DE TOUTES CONSÉQUENCES DUES AUX CHANGEMENTS QUI SERONT APPORTÉS AUX PLANS. -LES COTES ET LES DIMENSIONS ONT PRIORITÉ SUR LES DESSINS CERTAINES COTES SONT SUJETTES À UN AJUSTEMENT EN FONCTIONS DES MATÉRIAUX ET/OU MÉTHODES CHOISIS PAR L'ENTREPRENEUR. - SI L'ENTREPRENEUR VENAIT À CONSTATER DES DIFFÉRENCES ENTRE LE CHANTIER ET LE PRÉSENT PLAN, IL EST INVITÉ À CONTACTER LE RESPONSABLE DES PLANS DANS LES PLUS BREFS DÉLAIS.

DESSUS PLANCHER

1' - 0"

DESSUS SABLIÈRE

6" TYPE

SOLIN + CONTRE-SOLIN TYPE

DESSUS PLANCHER

L'ENTREPENEUR DOIT:

DESSUS EMPATTEMENT

ÉLÉVATION DROITE ÉCHELLE : 1/4" = 1'-0"

VENTILATEUR D'ENTRETOIT

12

12

5

5

6" TYPE

BARDEAUX D'ASPHALTE

DESSUS SABLIÈRE

DESSUS SABLIÈRE

8' - 2"

8' - 2"

2' - 0" TYPE

12 6

REVÊTEMENT VINYLE

12 BARDEAUX D'ASPHALTE

ALLÈGE DE PIERRE 2" TYPE

6 SOLIN + CONTRE-SOLIN TYPE

DESSUS SABLIÈRE

4"

TOLE D'ACIER PREPEINTE

FIXE

9' - 6"

MEMBRANES ELASTOMERES AUTOCOLLANTES

9' - 0"

8' - 2"

7' - 0" TYPE

2' - 0" GARDE-CORPS 3'-0" MIN.

MAISON MULTIFAMILIALE

DESSUS PLANCHER DESSUS SABLIÈRE

1' - 0"

6" TYPE

DESSUS PLANCHER

BLOCS ARCHITECTURAUX BRIQUE 4"

Élévation Droite et Élévation Gauche

ALLÈGE DE PIERRE 2" TYPE

1' - 4"

98' - 8"

DESSUS EMPATTEMENTS

DESSUS EMPATTEMENTS

Date

SOL FINI

Dessiné par Vérifié par

Novembre 2018 Cindy Okino Nathalie Martel

A107

ÉLÉVATION GAUCHE ÉCHELLE : 1/4" = 1'-0"

Echelle

1/4" = 1'-0"

12/17/2018 8:59:36 PM

2 M. À 10" = 1'-8" 3 CM. À ± 7 5/6" = 1'-10"

0001

Numéro de projet DESSUS DALLE ENTRÉE

5' - 2"

6' - 6"

PRÉVOIR PENTE VERS L'EXTÉRIEUR SUR 10'-0" (MIN. 6")

REVÊTEMENT VINYLE

8" MIN.

SOL FINI

6" MIN.

2' - 0"

DESSUS FONDATION

4' - 6" MIN.

100' - 0"


POUR LES MURS EXTÉRIEURS, SCELLER LES JOINTS DES PIÈCES DE BOIS DOUBLÉES (EX.: LISSE, CADRAGE, POTEAUX, ETC.)

1 BARDEAUX D'ASPHALTE FERMES DE TOIT PRÉFABRIQUÉ (VOIR FABRICANT)

FERME RENFORCÉE (VOIR FABRICANT)

www.emsom.qc.ca

DESSUS SABLIÈRE

2

10

NOTES GÉNÉRALES

8' - 2"

1 FERMES DE TOIT PRÉFABRIQUÉ (VOIR FABRICANT)

BARDEAUX D'ASPHALTE

5

L'ENTREPENEUR DOIT: 1) VÉRIFIER TOUTES LES DIMENSIONS AVANT DE DÉBUTER LES TRAVAUX. 2) RESPECTER S'IL Y A LIEU TOUTES LES EXIGENCES DES DOCUMENTS CONNEXES AU PLANS ET INFORMER LE CLIENT DE TOUTES CONSÉQUENCES DUES AUX CHANGEMENTS QUI SERONT APPORTÉS AUX PLANS.

FERME RENFORCÉE (VOIR FABRICANT)

BARDEAUX D'ASPHALTE

-LES COTES ET LES DIMENSIONS ONT PRIORITÉ SUR LES DESSINS CERTAINES COTES SONT SUJETTES À UN AJUSTEMENT EN FONCTIONS DES MATÉRIAUX ET/OU MÉTHODES CHOISIS PAR L'ENTREPRENEUR. - SI L'ENTREPRENEUR VENAIT À CONSTATER DES DIFFÉRENCES ENTRE LE CHANTIER ET LE PRÉSENT PLAN, IL EST INVITÉ À CONTACTER LE RESPONSABLE DES PLANS DANS LES PLUS BREFS DÉLAIS.

DESSUS PLANCHER DESSUS SABLIÈRE DESSUS SABLIÈRE GARAGE

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS.

9' - 0"

8' - 2"

OUVERTURES:

4 DESSUS FONDATION 2 1

SOL FINI

2

2

1

1

3. LINTEAUX AU DESSUS DES OUVERTURES 3.2"X12" INDIQUÉ SUR LES PLANS.

2

4. PROTECTION DES OUVERTURES: POUR UNE MEILLEURE PROTECTION ON RECOMMANDE L'UTILISATION DE MEMBRANES AUTOCOLLANTES CONFORMES À LA NORMES ASTM D 779 POUR LES JAMBAGES ET LE HAUT DE LA BAIE, EN PLUS DE CELLE REQUISE POUR LA LISSE D'APPUI. LES COINS DOIVENT ÉGALEMENT ÊTRE RENFORCÉS PAR UNE MEMBRANE DE COIN.

DESSUS FONDATION GARAGE

1

4' - 6"

6' - 6"

SOL FINI

3 DESSUS EMPATTEMENTS

DESSUS EMPATTEMENTS

LONGITUDINALE A COUPE ÉCHELLE : 1/4" = 1'-0"

NOTES STRUCTURES: TOUTES LES STRUCTURES DOIVENT ÊTRE VÉRIFIÉES ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURES.

DEVIS TECHNIQUES DES COMPOSANTES 1

COUPE BRISÉE

1 FERMES DE TOIT PRÉFABRIQUÉ (VOIR FABRICANT)

ACCÉS À L'ATTIQUE

TOITURE & PLAFOND (R-41) - BARDEAUX D'ASPHALTE IKO 25 ANS - BANDE DE DÉPART 3'-0" (TYPE WATER SHIELD) - MEMBRANE ÉLASTOMÈRE SOUS-COUCHE (TYPE DECKGARD) - CONTREPLAQUÉ 1/2″ AVEC COULISSEAUX (AGRAFES EN "H") - FERMES DE TOIT PRÉFABRIQUÉ @ 24" c/c (VOIR FABRICANT) - ISOLANT CELLULOSE GICLÉ (R-40 AVEC 2" MIN.) - CARTON FIBRE INT. 1/2″ (OPTIONNEL) - PARE-VAPEUR SCELLÉ - FOURRURES 1″X3″ @ 16″ c/c - GYPSE 1/2″ VISSÉ

2

MUR EXTÉRIEUR - LÉGER - REVËTEMENT EXTÉRIEUR LÉGER (CHOIX DU CLIENT) - FOURRURES 1″X3″ @ 16 c/c - MEMBRANE PARE-AIR (TYPE TYVEK) - REVËTEMENT INTERMÉDIAIRE TYPE R-5 - MONTANT 2″X6″ @ 16 c/c - LAINE R-20 MIN. (R-24 SI REQUIS) - PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm SCELLÉ - FOURRURES 1″X3″ @ 16 c/c - GYPSE 1/2″ VISSÉ

6

8' - 2"

STRUCTURE DU PLANCHER REINFORCÉ AUTOUR DU PUITS D'ÉSCALIER

7

3

MUR FONDATION - LÉGER

5

PLANCHER ÉTAGE

8' - 2"

2

5 DESSUS PLANCHER

DESSOUS PLAFOND

7"

14

13

4

PLANCHER DALLE REZ-DE-CHAUSSÉE - FINITION (CHOIX DU CLIENT) - DALLE DE BÉTON 4" AVEC TREILLIS MÉTALIQUE - PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm SCELLÉ - ISOLANT RIGIDE 2" (TYPE 4) R-5 - PIERRE CONCASSÉE 3/4" NET (6" ÉP.) - REMBLAIE

10

3' - 0"

9

8' - 2"

7 6

5

4" MI N.

4 DESSUS FONDATION

GARDE-CORPS

6

CLOISONS INTÉRIEURES - GYPSE 1/2" VISSÉ - 2"X4" @ 12" c/c (+ ENTREMISES MI-HAUTEUR SI PORTEUR) - 2"X6" @ 16" c/c (SI PLOMBERIE) - ISOLATION EN LAINE - GYPSE 1/2" VISSÉ

9' - 6"

11

8

POUTRE DE BOIS D'INGÉNIÉRIE ENCASTRÉE DANS LE PLANCHER TYPE (VOIR FABRICANT)

ÉCHAPÉE 6' - 8" MIN.

12

- FINI DE PLANCHER (CHOIX DU CLIENT) - CONTREPLAQUÉ 5/8" EMBOUVETÉ - POUTRELLES DE PLANCHER 11 7/8" @ 16" c/c (VOIR FABRICANT) - FOURRURE 1"X3" @ 16" c/c - GYPSE 1/2" VISSÉ

4 3

NEZ 1" TYPE

7

2 1

DESSUS DALLE ENTRÉE

SOL FINI

98' - 8"

3

5' - 2"

6' - 6"

SOL FINI

8

MUR EXTÉRIEUR - BRIQUE - GYPSE 1/2″ VISSÉ - FOURRURES 1″X3″ @ 16 c/c - PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm SCELLÉ - LAINE R-20 MIN. (R-24 SI REQUIS) - MONTANT 2″X6″ @ 16 c/c - REVËTEMENT INTERMÉDIAIRE TYPE R-5 - MEMBRANE PARE-AIR (TYPE TYVEK) - ESPACE D'AIR 1" - BRIQUE DE 4" AVEC ATTACHE MÉTALIQUE

BOIS: LE BOIS UTILISÉ SERA DE L'ÉPINETTE, DE GRADE #1 OU MEILLEUR. POTEAUX TYPES: LES POTEAUX DANS LES MURS EXTÉRIEURES DOIVENT ÊTRE MIN 3-2"X6 SAUF INDICATION CONTRAIRE. LES POTEAUX DANS LES MURS INTÉRIEURS DOIVENT ÊTRE MIN 3-2"X4" SAUF INDICATION CONTRAIRE. POUTRES: LA POUTRE AU SOUS-SOL DE TYPE W EN ACIER SERA À CALCULER ET VÉRIFIER PAR FABRICANT. PLANCHERS POUTRELLES: CHOISIR LA FLEXIBILITÉ DES POUTRELLES EN FONCTION DES REVÊTEMENTS DE PLANCHER, VOIR CLIENT. DOUBLER LES POUTRELLES AU POURTOUR DES PUITS D'ESCALIER.

LE BOIS UTILISÉS À LA FABRICATION DES FERMES PRÉFABRIQUÉES DOIVENT ÊTRE CONFORMES À LA NORME CAN3-086 ET AU CODE NATIONAL DU BÂTIMENT DU CANADA.

DESSUS PLANCHER

10" 15

DESSUS SABLIÈRE

- CRÉPI DE BÉTON, HORS SOL - MEMBRANE BITUMINEUSE GOUDRONNÉE - MUR DE BÉTON 8" + ARMATURE - ISOLANT RIGIDE 2" (TIPE 2) 4'-0" DANS LE SOL - REMBLAIE

EMPATTEMENT: LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉ SELON LA NATURE DU SOL. VÉRIFIÉ PAR INGÉNIEUR.

FERMES DE TOIT

DESSUS SABLIÈRE

DESSUS SABLIÈRE

100' - 0"

2. LINTEAUX AU DESSUS DES OUVERTURES 2.2"X10" SAUF AVIS CONTRAIRE.

8

MUR FONDATION - BRIQUE - REMBLAIE - ISOLANT RIGIDE 2" (TIPE 2) 4'-0" DANS LE SOL - MUR DE BÉTON 12" + ARMATURE - MEMBRANE BITUMINEUSE GOUDRONNÉE - CRÉPI DE BÉTON, HORS SOL

SE RÉFÉRER AU PLAN DE TOITURE FOURNI PAR LE FABRICANT DES FERMES DE TOIT POUR L'EMPLACEMENT EXACT DES APPUIS ET DES POUTRES ET/OU DES FERMES MAÎTRESSES. MUR DE MACONNERIE -DANS UN MUR DE MACONNERIE, LES ATTACHES DE MÉTAL SERONT ESPACÉES DE 3'-0" MAX. À L'HORIZONTALE ET À 16" MA. À LA VERTICALE, LA GROSSEUR DES LINTEAUX D'ACIER AU-DESSUS DES OUVERTURES SERA DÉTERMINÉE PAR LE MAÇON.

MAISON MULTIFAMILIALE Coupe Longitudinale et Coupe Transversale

Dessiné par

DESSUS EMPATTEMENTS

DESSUS EMPATTEMENTS

9 B

COUPE TRANSVERSALE ÉCHELLE : 1/4" = 1'-0"

PLANCHER DALLE GARAGE - DALLE DE BÉTON 4" AVEC TREILLIS D'ACIER 6"X6" - PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm SCELLÉ - ISOLANT RIGIDE 2" (TYPE 4) R-7.5 - PIERRE CONCASSÉE 3/4" NET (10" ÉP.) - REMBLAIE

10

MUR MITOYEN - 2 GYPSES 1/2" FIRE COLD - BARRIÈRERÉSILIENTE 1/2" @ 16" c/c - LAINE INSONORISANTE (RACUL) - ESPACE D'AIR 1" - LAINE INSONORISANTE (RACUL) - BARRIÈRERÉSILIENTE 1/2" @ 16" c/c - 2 GYPSES 1/2" FIRE COLD

0001

Numéro de projet Date

Vérifié par

Novembre 2018 Cindy Okino Nathalie Martel

A108 Echelle

1/4" = 1'-0"

2018-12-05 10:23:45

100' - 0"

9

1.LES DIMENSIONS DES PORTES ET FENÊTRES SONT À TITRE INDICATIF. L'ENTREPRENEUR DEVRA AVOIR LES DIMENSIONS EXACTES DU FOURNISSEUR AFIN DE FAIRE LES OUVERTURES EN CONSÉQUENCES.


MUR MITOYEN NOTE: LE GYPSE EST POSÉ JUSQU'À LA SOUS-FACE OU SUPPORT DE REVËTEMENT DE TOIT

-

GYPSE 5/8" FIRE COLD FERME DE TOIT ESPACE D'AIR 1" FERME DE TOIT GYPSE 5/8" FIRE COLD

ESPACE D'AIR 2 1/2" MIN.

ESPACE D'AIR 2 1/2" MIN.

METTRE UNE MEMBRANE AUTOCOLLANTE SUR TOUTES SECTIONS DE TOITURE AYANT UNE PENTE DE MOINS DE 4/12.

MEMBRANE AUTOCOLLANTE

MEMBRANE AUTOCOLLANTE

DÉFLECTEUR DE VENTILATION POUR ISOLANT (VOIR FABRICANT)

DÉFLECTEUR DE VENTILATION POUR ISOLANT (VOIR FABRICANT)

FASCIA D'ALUMINIUM

TOITURE & PLAFOND (R-41) -

FERMES DE TOIT PRÉFABRIQUÉ @ 24" c/c (VOIR FABRICANT) ISOLANT CELLULOSE GICLÉ (R-40 AVEC 2" MIN.) CARTON FIBRE INT. 1/2″ (OPTIONNEL) PARE-VAPEUR SCELLÉ FOURRURES 1″X3″ @ 16″ c/c GYPSE 1/2″ VISSÉ

MUR MITOYEN -

www.emsom.qc.ca

SOLIN D'ALUMINIUM

SOLIN D'ALUMINIUM

FASCIA D'ALUMINIUM

12" MIN.

12" MIN.

NOTES GÉNÉRALES SOFFITE PERFORÉ ET MOULURE EN "J"

SOFFITE PERFORÉ ET MOULURE EN "J"

SABLIÈRE DOUBLE 2-2"X6"

VOIR ÉLÉVATIONS

SABLIÈRE DOUBLE 2-2"X6"

VOIR ÉLÉVATIONS

TOITURE & PLAFOND (R-41) -

PRÉVOIR DU CONTREVENTEMENT DANS LES MURS EXTÉRIEURS. LE CONTREVENTEMENT PEUT ËTRE UN CONTREPLAQUÉ 1/2", UN OSB 1/2" OU DES BARRES MÉTALLIQUES EN "T" INSTALLÉES À 45°.

BARDEAUX D'ASPHALTE IKO 25 ANS BANDE DE DÉPART 3'-0" (TYPE WATER SHIELD) MEMBRANE ÉLASTOMÈRE SOUS-COUCHE (TYPE DECKGARD) CONTREPLAQUÉ 1/2″ AVEC COULISSEAUX (AGRAFES EN "H") FERMES DE TOIT PRÉFABRIQUÉ @ 24" c/c (VOIR FABRICANT) ISOLANT CELLULOSE GICLÉ (R-40 AVEC 2" MIN.) CARTON FIBRE INT. 1/2″ (OPTIONNEL) PARE-VAPEUR SCELLÉ FOURRURES 1″X3″ @ 16″ c/c GYPSE 1/2″ VISSÉ

CALFEUTRAGE + ISOLATION

TOITURE & PLAFOND (R-41)

L'ENTREPENEUR DOIT:

-

1) VÉRIFIER TOUTES LES DIMENSIONS AVANT DE DÉBUTER LES TRAVAUX. 2) RESPECTER S'IL Y A LIEU TOUTES LES EXIGENCES DES DOCUMENTS CONNEXES AU PLANS ET INFORMER LE CLIENT DE TOUTES CONSÉQUENCES DUES AUX CHANGEMENTS QUI SERONT APPORTÉS AUX PLANS.

BARDEAUX D'ASPHALTE IKO 25 ANS BANDE DE DÉPART 3'-0" (TYPE WATER SHIELD) MEMBRANE ÉLASTOMÈRE SOUS-COUCHE (TYPE DECKGARD) CONTREPLAQUÉ 1/2″ AVEC COULISSEAUX (AGRAFES EN "H") FERMES DE TOIT PRÉFABRIQUÉ @ 24" c/c (VOIR FABRICANT) ISOLANT CELLULOSE GICLÉ (R-40 AVEC 2" MIN.) CARTON FIBRE INT. 1/2″ (OPTIONNEL) PARE-VAPEUR SCELLÉ FOURRURES 1″X3″ @ 16″ c/c GYPSE 1/2″ VISSÉ

MUR EXTÉRIEUR BRIQUE

MUR EXTÉRIEUR LÉGER

GYPSE 1/2" FIRE COLD GYPSE 1/2" FIRE COLD BARRIÈRERÉSILIENTE 1/2" @ 16" c/c LAINE INSONORISANTE (RACUL) ESPACE D'AIR 1" LAINE INSONORISANTE (RACUL) BARRIÈRERÉSILIENTE 1/2" @ 16" c/c GYPSE 1/2" FIRE COLD GYPSE 1/2" FIRE COLD

-

PLINTHE

REVËTEMENT EXTÉRIEUR LÉGER (CHOIX DU CLIENT) FOURRURES 1″X3″ @ 16 c/c MEMBRANE PARE-AIR (TYPE TYVEK) REVËTEMENT INTERMÉDIAIRE TYPE R-5 MONTANT 2″X6″ @ 16 c/c LAINE R-20 MIN. (R-24 SI REQUIS) PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm SCELLÉ FOURRURES 1″X3″ @ 16 c/c GYPSE 1/2″ VISSÉ

PRÉVOIR DU CONTREVENTEMENT DANS LES MURS EXTÉRIEURS. LE CONTREVENTEMENT PEUT ËTRE UN CONTREPLAQUÉ 1/2", UN OSB 1/2" OU DES BARRES MÉTALLIQUES EN "T" INSTALLÉES À 45°.

-

PLINTHE

BRIQUE DE 4" AVEC ATTACHE MÉTALIQUE ESPACE D'AIR 1" MEMBRANE PARE-AIR (TYPE TYVEK) REVËTEMENT INTERMÉDIAIRE TYPE R-5 MONTANT 2″X6″ @ 16 c/c LAINE R-20 MIN. (R-24 SI REQUIS) PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm SCELLÉ FOURRURES 1″X3″ @ 16 c/c GYPSE 1/2″ VISSÉ

-LES COTES ET LES DIMENSIONS ONT PRIORITÉ SUR LES DESSINS CERTAINES COTES SONT SUJETTES À UN AJUSTEMENT EN FONCTIONS DES MATÉRIAUX ET/OU MÉTHODES CHOISIS PAR L'ENTREPRENEUR. - SI L'ENTREPRENEUR VENAIT À CONSTATER DES DIFFÉRENCES ENTRE LE CHANTIER ET LE PRÉSENT PLAN, IL EST INVITÉ À CONTACTER LE RESPONSABLE DES PLANS DANS LES PLUS BREFS DÉLAIS. - LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS.

OUVERTURES: 1.LES DIMENSIONS DES PORTES ET FENÊTRES SONT À TITRE INDICATIF. L'ENTREPRENEUR DEVRA AVOIR LES DIMENSIONS EXACTES DU FOURNISSEUR AFIN DE FAIRE LES OUVERTURES EN CONSÉQUENCES. 2. LINTEAUX AU DESSUS DES OUVERTURES 2.2"X10" SAUF AVIS CONTRAIRE. 3. LINTEAUX AU DESSUS DES OUVERTURES 3.2"X12" INDIQUÉ SUR LES PLANS.

BRIQUE

REVËTEMENT LÉGER -

GYPSE 5/8" FIRE COLD GYPSE 5/8" FIRE COLD LAINE (RACUL) R-14 POUTRELLES ESPACE D'AIR 1" POUTRELLES LAINE (RACUL) R-14 GYPSE 5/8" FIRE COLD GYPSE 5/8" FIRE COLD

PLANCHER ÉTAGE

SABLIÈRE DOUBLE 2-2"X6"

- FINI DE PLANCHER (CHOIX DU CLIENT) - CONTREPLAQUÉ 5/8" EMBOUVETÉ - POUTRELLES DE PLANCHER 11 7/8" @ 16" c/c (VOIR FABRICANT) - FOURRURE 1"X3" @ 16" c/c - GYPSE 1/2" VISSÉ

4. PROTECTION DES OUVERTURES: POUR UNE MEILLEURE PROTECTION ON RECOMMANDE L'UTILISATION DE MEMBRANES AUTOCOLLANTES CONFORMES À LA NORMES ASTM D 779 POUR LES JAMBAGES ET LE HAUT DE LA BAIE, EN PLUS DE CELLE REQUISE POUR LA LISSE D'APPUI. LES COINS DOIVENT ÉGALEMENT ÊTRE RENFORCÉS PAR UNE MEMBRANE DE COIN.

URÉTHANE

URÉTHANE

LINTEAU 2-2"X10" TYPE OU TEL QUE INDIQUÉ SUR LE PLAN

SOLIN

- 1er RANGE DE BRIQUE JOINT OUVERTES @ 24" c/c - SOLIN 18" DE HAUT - LINTEAU D'ACIER

PLANCHER ÉTAGE - FINI DE PLANCHER (CHOIX DU CLIENT) - CONTREPLAQUÉ 5/8" EMBOUVETÉ - POUTRELLES DE PLANCHER 11 7/8" @ 16" c/c (VOIR FABRICANT) - FOURRURE 1"X3" @ 16" c/c - GYPSE 1/2" VISSÉ

PLANCHER ÉTAGE

SABLIÈRE DOUBLE 2-2"X6"

- FINI DE PLANCHER (CHOIX DU CLIENT) - CONTREPLAQUÉ 5/8" EMBOUVETÉ - POUTRELLES DE PLANCHER 11 7/8" @ 16" c/c (VOIR FABRICANT) - FOURRURE 1"X3" @ 16" c/c - GYPSE 1/2" VISSÉ

LINTEAU 2-2"X10" TYPE OU TEL QUE INDIQUÉ SUR LE PLAN CALFEUTRAGE + ISOLATION

CALFEUTRAGE + ISOLATION

NOTES STRUCTURES: TOUTES LES STRUCTURES DOIVENT ÊTRE VÉRIFIÉES ET APPROUVÉES PAR UN INGÉNIEUR EN STRUCTURES.

POUR LES MURS EXTÉRIEURS , SCÉLLER LES JOINTS DES PIÈCES DE BOIS DOUBLÉES (EX.: LISSE, CADRAGE, POTEAUX, ETC.)

CALFEUTRAGE + ISOLATION

EMPATTEMENT: LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉ SELON LA NATURE DU SOL. VÉRIFIÉ PAR INGÉNIEUR.

SOLIN

BOIS: LE BOIS UTILISÉ SERA DE L'ÉPINETTE, DE GRADE #1 OU MEILLEUR. POTEAUX TYPES: LES POTEAUX DANS LES MURS EXTÉRIEURES DOIVENT ÊTRE MIN 3-2"X6 SAUF INDICATION CONTRAIRE. CALFEUTRAGE + ISOLATION

LES POTEAUX DANS LES MURS INTÉRIEURS DOIVENT ÊTRE MIN 3-2"X4" SAUF INDICATION CONTRAIRE.

PIERRE ARTIFICIELLE + LARMIER EN-DESSOUS

PLINTHE

PLANCHER DALLE REZ-DE-CHAUSSÉE

PLANCHER DALLE REZ-DE-CHAUSSÉE

-

-

FINITION (CHOIX DU CLIENT) DALLE DE BÉTON 4" AVEC TREILLIS MÉTALIQUE PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm SCELLÉ ISOLANT RIGIDE 2" (TYPE 4) R-5 PIERRE CONCASSÉE 3/4" NET (6" ÉP.) REMBLAIE

PLINTHE

FINITION (CHOIX DU CLIENT) DALLE DE BÉTON 4" AVEC TREILLIS MÉTALIQUE PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm SCELLÉ ISOLANT RIGIDE 2" (TYPE 4) R-5 PIERRE CONCASSÉE 3/4" NET (6" ÉP.) REMBLAIE

PLANCHER DALLE REZ-DE-CHAUSSÉE -

BLOCS ARCHITECTURAUX

PLINTHE

LISSE D'ASSISE 2"X6" + BANDE D'ÉTHAFOAM

LISSE D'ASSISE 2"X6" + BANDE D'ÉTHAFOAM

ANCRAGES Ø1/2" X 6" LA. @ 4'-0" c/c

ANCRAGES Ø1/2" X 6" LA. @ 4'-0" c/c

FINITION (CHOIX DU CLIENT) DALLE DE BÉTON 4" AVEC TREILLIS MÉTALIQUE PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm SCELLÉ ISOLANT RIGIDE 2" (TYPE 4) R-5 PIERRE CONCASSÉE 3/4" NET (6" ÉP.) REMBLAIE

POUTRES: LA POUTRE AU SOUS-SOL DE TYPE W EN ACIER SERA À CALCULER ET VÉRIFIER PAR FABRICANT. PLANCHERS POUTRELLES: CHOISIR LA FLEXIBILITÉ DES POUTRELLES EN FONCTION DES REVÊTEMENTS DE PLANCHER, VOIR CLIENT. DOUBLER LES POUTRELLES AU POURTOUR DES PUITS D'ESCALIER. FERMES DE TOIT

6"

PRÉVOIR DES RENFORCEMENTS EN ACIER DANS LES MURS DE FONDATION, DES SEMELLES, DE LA DALLE DE BÉTON OU SUIVRE LES RECOMMANDATIONS D'UN INGÉNIEUR, SAUF INDICATION CONTRAIRE.

LE BOIS UTILISÉS À LA FABRICATION DES FERMES PRÉFABRIQUÉES DOIVENT ÊTRE CONFORMES À LA NORME CAN3-086 ET AU CODE NATIONAL DU BÂTIMENT DU CANADA.

2"

SE RÉFÉRER AU PLAN DE TOITURE FOURNI PAR LE FABRICANT DES FERMES DE TOIT POUR L'EMPLACEMENT EXACT DES APPUIS ET DES POUTRES ET/OU DES FERMES MAÎTRESSES.

PRÉVOIR DES RENFORCEMENTS EN ACIER DANS LES MURS DE FONDATION, DES SEMELLES, DE LA DALLE DE BÉTON OU SUIVRE LES RECOMMANDATIONS D'UN INGÉNIEUR, SAUF INDICATION CONTRAIRE.

4 1/2"

CRÉPI

MUR DE MACONNERIE -DANS UN MUR DE MACONNERIE, LES ATTACHES DE MÉTAL SERONT ESPACÉES DE 3'-0" MAX. À L'HORIZONTALE ET À 16" MA. À LA VERTICALE, LA GROSSEUR DES LINTEAUX D'ACIER AU-DESSUS DES OUVERTURES SERA DÉTERMINÉE PAR LE MAÇON.

7 1/2"

CRÉPI

SOL FINI 12"

8"

8"

REMBLAIE ISOLANT RIGIDE 2" (TIPE 2) 4'-0" DANS LE SOL MUR DE BÉTON 8" + ARMATURE ISOLANT RIGIDE 2" (TIPE 2) 4'-0" DANS LE SOL REMBLAIE

MUR FONDATION - LÉGER -

- MEMBRANE GEOTËXTILE - PIERRE CONCASSÉE 3/4" PROPRE DB - DRAIN Ø4" PERFORÉ

CRÉPI DE BÉTON, HORS SOL MEMBRANE BITUMINEUSE GOUDRONNÉE MUR DE BÉTON 8" + ARMATURE ISOLANT RIGIDE 2" (TIPE 2) 4'-0" DANS LE SOL REMBLAIE

- MEMBRANE D'ÉTANCHEITÉ SOUS LE NIVEAU DU SOL FINI (MEMBRANE AUTOUT DES PILASTRES ET DES ANGLES DE BÉTON) -MEMBRANE DE DRAINAGE DE TYPE DELTA OU ÉQUIVALENTE (OPTIONELLE)

MUR FONDATION - LÉGER -

- MEMBRANE GEOTËXTILE - PIERRE CONCASSÉE 3/4" PROPRE DB - DRAIN Ø4" PERFORÉ

10"

10"

-

- MEMBRANE D'ÉTANCHEITÉ SOUS LE NIVEAU DU SOL FINI (MEMBRANE AUTOUT DES PILASTRES ET DES ANGLES DE BÉTON) -MEMBRANE DE DRAINAGE DE TYPE DELTA OU ÉQUIVALENTE (OPTIONELLE)

10"

MUR FONDATION

CAPACITÉ PORTANTE DU SOL

MAISON MULTIFAMILIALE

CRÉPI DE BÉTON, HORS SOL MEMBRANE BITUMINEUSE GOUDRONNÉE MUR DE BÉTON 8" + ARMATURE ISOLANT RIGIDE 2" (TIPE 2) 4'-0" DANS LE SOL REMBLAIE

Détails Coupes de Murs

Date

CAPACITÉ PORTANTE DU SOL EST ASSUMÉE À 2000 lb/pi.ca. POUR UNE CAPACITÉ INFÉRIEURE, L'ENTREPENEUR APPORTERA LES AJUSTEMENTS REQUIS AUX DIMENSIONS DES EMPATTEMENTS, SELON LES RECOMMANDATIONS DU CODE EN VIGUEUR ET/OU INGÉNIEUR.

24"

24"

36"

Dessiné par Vérifié par

MITOYEN À OSSATURE DE BOIS C MUR ÉCHELLE : 1/2" = 1'-0"

D

MUR LÉGER TYPE ÉCHELLE : 1/2" = 1'-0"

0001

Numéro de projet

UN TEST DE CAPACITÉ DU SOL ESTFORTEMENT SUGGÉRÉ

EMPATTEMENTS

Novembre 2018 Cindy Okino Nathalie Martel

A109

BRIQUE TYPE E MUR ÉCHELLE : 1/2" = 1'-0" Echelle

Comme indiqué

2018-12-05 10:23:26

SOL FINI


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.