Bs6883&bs7917 offshore & marine cable

Page 1

Caledonian Caledonian Offshore & Marine Cables

BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

www.caledonian-cables.co.uk www.addison-cables.com


Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. Our superior products provide leading edge within every cable series and for every application. Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard, ISO Standard etc. Caledonian Cables offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia. Caledonian & Addison, produces a wide range of cables for communication, power and electronics in its primary plants in UK, Italy and Spain. To stay in front, we continually keep expanding our manufacturing capabilities in more low cost region such as Romania, Taiwan, Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible, scalable global system that delivers superior operational performance and optimal results for our customers. Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing, logistic services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market. Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning, we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured. Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industryspecific solutions. Caledonian & Addison has established an extensive network of design, manufacturing, and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers.


CONTENT MV Flame Retardant Power & Control Cables 1.9/3.3kV, 3.3/3.3kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables ......................................................................................................................................3 3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control Cables (Radial Field) .................................................................................6 3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Radial Field) ..................................................................................................9 3.8/6.6kV, 6.6/6.6kV, 6.35/11kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Non Radial Field) ........................................................................................12

MV Fire Resistant Power & Control Cables 1.9/3.3kV, 3.3/3.3kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Fire Resistant Power & Control Cables ....................................................................................................................................15

LV Flame Retardant Power & Control Cables 0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control Cables .................................................................................................................................................18 0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables .............................................................................................................................................................21

LV Fire Resistant Power & Control Cables 0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control Cables .............................................................................................................................................................24 0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Fire Resistant Power & Control Cables .............................................................................................................................................................27

Flame Retardant Instrumentation & Control Cables 150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Unarmoured Flame Retardant Instrumentation & Control Cables ......................................................................................30

www.addison-cables.com

ADDISON

1


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Content www.caledonian-cables.co.uk

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation & Control Cables ......................................................................................32 150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation & Control Cables .......................................................................................................34 150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Armoured Flame Retardant Instrumentation & Control Cables .......................................................................................................36

Fire Resistant Instrumentation & Control Cables 150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Unarmoured Fire Resistant Instrumentation & Control Cables .......................................................................................................38 150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Unarmoured Fire Resistant Instrumentation & Control Cables .......................................................................................................40 150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Armoured Fire Resistant Instrumentation & Control Cables .......................................................................................................42 150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Armoured Fire Resistant Instrumentation & Control Cables .......................................................................................................44

Technical Information Cores IdentiďŹ cation ..............................................................................................................................46

2

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

1.9/3.3kV, 3.3/3.3kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables Application These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards BS 6883  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 607542 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Stranded Tinned Copper Conductor HF-EPR GP5 Insulation SW2/SW4 Inner Sheath Galvanized Steel Wire/Tinned Bronze Wire Braid SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Insulation: HF-EPR GP5 according to BS 7655 1.2.  Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  Armour: Galvanized steel wire braid or tinned bronze wire braid (single core).  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

Mechanical and Thermal Properties Minimum Internal Bending Radius: 6×OD Temperature Range: -40℃ ~ +90℃

www.addison-cables.com

ADDISON

3


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight 1.9/3.3kV Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 1×630 3×10 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 3×300

2.2 2.2 2.2 2.2 2.2 2.2 2.4 2.4 2.4 2.4 2.4 2.4 2.6 2.8 2.8 2.2 2.2 2.2 2.2 2.2 2.2 2.4 2.4 2.4 2.4 2.4 2.4

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.1 1.2 1.2 1.3 1.3 1.4 1.5 1.6 1.6 1.7 1.8 1.9 2.0 2.2 2.3 1.5 1.6 1.8 1.8 1.9 2.1 2.3 2.4 2.6 2.7 3.0 3.2

10.2 11.4 13.0 14.1 15.3 17.2 19.4 21.3 22.8 24.8 27.5 30.0 33.8 37.6 41.2 20.4 22.8 26.6 28.4 31.2 35.3 40.2 44.0 47.6 51.7 57.7 63.1

11.9 13.1 14.8 15.9 17.2 19.2 21.9 23.8 25.4 27.4 30.3 33.2 37.1 41.1 45.2 22.9 25.3 29.3 31.2 34.4 38.7 44.1 48.1 51.8 56.4 62.9 68.6

Nominal Armour Wire Diameter mm

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.3 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45

1.3 1.3 1.4 1.4 1.5 1.6 1.7 1.7 1.8 1.9 2.0 2.1 2.3 2.5 2.6 1.7 1.8 2.0 2.1 2.2 2.4 2.6 2.7 2.9 3.0 3.3 3.5

14.2 15.4 17.1 18.2 19.6 21.7 24.2 26.0 28.4 30.6 33.5 36.2 40.3 44.5 48.4 25.1 27.7 32.6 34.6 37.6 42.1 47.4 51.4 55.3 59.6 66.2 72.0

16.2 17.6 19.5 20.6 22.4 24.6 27.2 29.1 31.6 34.3 37.3 40.1 44.8 49.2 53.6 28.2 30.8 36.3 38.5 41.6 46.7 52.1 56.7 60.8 65.7 72.6 79.0

398 499 675 793 970 1269 1623 1983 2423 2917 3654 4428 5416 6726 8562 1052 1357 2032 2382 2936 3877 4995 6118 7284 8750 11118 13531

Nominal Armour Wire Diameter mm

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

0.3 0.3 0.3 0.3 0.3

1.4 1.4 1.5 1.5 1.6

16.1 17.1 19.1 19.9 21.5

18.4 19.4 21.5 22.8 24.4

483 579 774 885 1082

3.3/3.3kV Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×10 1×16 1×25 1×35 1×50

4

3.0 3.0 3.0 3.0 3.0

ADDISON

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.2 1.2 1.3 1.3 1.4

12.0 13.0 14.7 15.6 17.0

www.addison-cables.com

13.7 14.7 16.7 17.6 19.0


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 1×630 3×10 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240

3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.2 3.2 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.5 1.5 1.6 1.7 1.7 1.8 1.9 2.1 2.2 2.4 1.7 1.8 1.9 2.0 2.1 2.2 2.4 2.5 2.7 2.8 3.1

18.9 20.6 22.5 24.1 26.0 28.7 31.2 34.7 38.4 42.2 24.1 26.5 30.1 32.1 34.9 38.9 42.9 46.7 50.3 54.4 60.4

21.0 23.1 25.0 26.8 28.6 31.8 34.4 38.1 41.9 46.2 26.7 29.2 33.2 35.4 38.3 42.7 46.9 50.9 54.9 59.2 65.7

Nominal Armour Wire Diameter mm

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45

1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.5 2.6 1.9 2.0 2.1 2.2 2.3 2.5 2.7 2.8 3.0 3.2 3.4

23.4 25.3 27.4 30.0 32.0 34.8 37.6 41.3 45.3 49.4 29.9 32.5 36.3 38.5 41.5 45.8 50.2 54.2 58.2 62.7 69.1

26.4 28.4 30.5 33.6 35.7 38.7 41.5 45.8 50.0 54.6 33.6 36.2 40.2 42.9 46.0 50.5 55.5 59.7 64.2 68.9 76.0

1377 1699 2081 2550 3032 3780 4563 5514 6807 8691 1404 1738 2314 2701 3278 4226 5297 6442 7631 9158 11526

www.addison-cables.com

ADDISON

5


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control Cables (Radial Field) Application These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards

Stranded Tinned Copper Conductor

BS 6883  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Conductor Screen HF-EPR GP5 Insulation Insulation Screen SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Conductor Screen: Semiconducting layer or tape.  Insulation: HF-EPR GP5 according to BS 7655 1.2.  Insulation Screen: Semiconducting layer or tape +Tinned copper tape.  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

Mechanical and Thermal Properties Minimum Internal Bending Radius: 15×OD (single core); 20×OD (three core) Temperature Range: -40℃ ~ +90℃

6

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight 3.8/6.6kV Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 1×630 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240

3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.2 3.2 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.3 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.8 1.9 2.0 2.1 2.3 2.4 1.8 2.0 2.0 2.2 2.3 2.5 2.6 2.7 2.9 3.1

16.0 17.6 18.7 19.9 21.8 23.7 25.4 27.0 29.0 31.7 34.3 37.6 41.4 45.1 32.7 36.5 38.4 41.3 45.3 49.3 53.1 56.5 60.8 66.6

18.0 19.7 20.8 22.3 24.3 26.3 28.0 29.8 32.1 35.0 37.6 41.1 45.5 49.2 36.0 39.9 41.9 45.3 49.4 53.9 57.8 61.4 66.1 72.2

492 658 776 942 1229 1546 1890 2242 2713 3427 4177 5145 6408 8134 1482 2031 2359 2918 3788 4776 5868 6933 8401 10616

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.3 1.4 1.4 1.5 1.5 1.6 1.7 1.7 1.8 1.9

16.8 18.6 19.4 20.8 22.6 24.4 26.3 27.8 29.8 32.5

18.8 20.7 21.9 23.3 25.1 27.1 29.0 30.6 32.9 35.8

524 704 813 994 1272 1592 1956 2294 2769 3487

6.35/11kV Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240

3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4

www.addison-cables.com

ADDISON

7


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm 1×300 1×400 1×500 1×630 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240

3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

2.0 2.1 2.3 2.4 1.9 2.0 2.1 2.2 2.4 2.5 2.7 2.8 3.0 3.2

35.0 38.4 41.8 45.5 34.5 38.2 40.2 43.0 47.1 51.0 55.0 58.4 62.7 68.5

38.4 41.9 45.8 49.6 37.9 41.6 44.1 47.0 51.3 55.6 59.8 63.3 68.1 74.1

4242 5208 6442 8176 1601 2139 2497 3040 3949 4919 6055 7132 8613 10848

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter Mm

Approx. Weight kg/km

1.5 1.5 1.5 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.4 2.5 2.2 2.3 2.4 2.6 2.7 2.9 3.0 3.2

20.9 21.7 22.9 24.9 26.7 28.6 30.1 32.1 34.8 37.3 40.7 44.1 47.8 43.1 45.2 47.9 52.1 55.9 59.9 63.3 67.6

23.4 24.3 25.5 27.5 29.5 31.4 33.3 35.3 38.2 40.8 44.6 48.2 52.0 47.1 49.2 52.1 56.7 60.7 64.9 68.7 73.2

808 921 1110 1396 1726 2099 2445 2929 3661 4429 5390 6638 8415 2458 2832 3395 4336 5334 6500 7602 9116

8.7/15kV Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 1×630 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185

8

ADDISON

4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

3.8/6.6kV, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Radial Field) Application These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards BS 6883  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 607542 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

SW2/SW4 Inner Sheath Stranded Tinned Copper Conductor Conductor Screen HF-EPR GP5 Insulation Insulation Screen Galvanized Steel Wire/Tinned Bronze Wire Braid SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Conductor Screen: Semiconducting layer or tape.  Insulation: HF-EPR GP5 according to BS 7655 1.2.  Insulation Screen: Semiconducting layer or tape +Tinned copper tape.  Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  Armour: Galvanized steel wire braid or tinned bronze wire braid (single core).  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

Mechanical and Thermal Properties Minimum Internal Bending Radius: 15×OD (single core); 20×OD (three core) Temperature Range: -40℃ ~ +90℃ www.addison-cables.com

ADDISON

9


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight 3.8/6.6kV Construction No. of cores×Cross section(mm²)

Nominal Insulation Thickness mm

1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 1×630 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240

3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.2 3.2 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0

6.35/11kV Construction No. of cores×Cross section(mm²)

Nominal Insulation Thickness mm

1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150

3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4

10

ADDISON

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.3 16.0 18.0 1.3 17.6 19.7 1.4 18.7 20.8 1.4 19.9 22.3 1.5 21.8 24.3 1.6 23.7 26.3 1.6 25.4 28.0 1.7 27.0 29.8 1.8 29.0 32.1 1.9 31.7 35.0 2.0 34.3 37.6 2.1 37.6 41.4 2.3 41.4 45.4 45.1 49.2 2.4 1.8 32.7 36.0 2.0 36.5 39.9 2.0 38.4 41.9 2.2 41.3 45.3 2.3 45.3 49.4 2.5 49.3 53.9 2.6 53.1 57.8 2.7 56.6 61.4 2.9 60.8 66.1 3.1 66.6 72.2

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 1.4 1.5 1.5 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.4 2.5 2.7 2.1 2.2 2.3 2.4 2.6 2.8 2.9 3.1 3.2 3.5

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.3 16.8 18.8 1.4 18.6 20.7 1.4 19.4 21.9 1.5 20.8 23.3 1.5 22.6 25.1 1.6 24.4 27.1 1.7 26.3 29.0 1.7 27.8 30.6

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45

Nominal Outer Sheath Thickness mm 1.5 1.5 1.6 1.6 1.7 1.8 1.9 2.0

www.addison-cables.com

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

20.2 21.9 23.0 24.4 26.5 28.6 30.2 32.8 35.0 37.9 40.6 44.4 48.4 52.4 38.9 42.9 44.9 48.1 52.4 56.8 60.8 64.6 69.1 75.5

23.0 24.9 26.0 27.4 29.6 31.8 33.9 36.6 38.9 41.9 45.1 49.0 53.6 57.8 43.3 47.5 49.6 53.3 57.4 62.4 67.0 70.9 76.0 82.6

790 950 1060 1320 1610 1930 2260 2760 3210 3960 4660 5470 6610 8230 2610 3220 3700 4360 5410 6710 7770 9160 10430 12840

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

21.1 22.9 24.0 25.3 27.3 29.3 32.1 33.8

24 25.9 27.0 28.4 30.4 33.0 35.9 37.6

810 980 1110 1360 1660 1970 2360 2810


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Construction No. of cores×Cross section(mm²)

Nominal Insulation Thickness mm

1×185 1×240 1×300 1×400 1×500 1×630 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240

3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4

8.7/15kV Construction No. of cores×Cross section(mm²)

Nominal Insulation Thickness mm

1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 1×630 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185

4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.8 29.8 32.9 1.9 32.5 35.8 38.4 2.0 35.0 2.1 38.4 41.9 2.3 41.8 45.8 2.4 45.5 49.6 1.9 34.5 37.9 2.0 38.2 41.6 2.1 40.2 44.1 2.2 43.0 47.0 2.4 47.1 51.3 2.5 51.0 55.6 2.7 55.0 59.8 2.8 58.4 63.3 3.0 62.7 68.1 3.2 68.5 74.1

Nominal Armour Wire Diameter mm 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 2.0 2.2 2.3 2.4 2.5 2.7 2.1 2.3 2.4 2.5 2.7 2.8 3.0 3.1 3.3 3.6

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.5 20.9 23.4 1.5 21.7 24.3 1.5 22.9 25.5 1.6 24.9 27.5 1.7 26.7 29.5 1.8 28.6 31.4 1.8 30.1 33.3 1.9 32.1 35.3 2.0 34.8 38.2 2.1 37.3 40.8 2.2 40.7 44.6 2.4 44.1 48.2 2.5 47.8 52.0 2.2 43.1 47.1 2.3 45.2 49.2 2.4 47.9 52.1 2.6 52.1 56.7 2.7 55.9 60.7 2.9 59.9 64.9 3.0 63.3 68.7 3.2 67.6 73.2

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 1.6 1.7 1.7 1.8 1.9 2.0 2.1 2.1 2.2 2.4 2.5 2.6 2.8 2.5 2.6 2.7 2.9 3.0 3.2 3.3 3.5

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

35.8 38.9 41.6 45.1 48.8 52.8 40.7 44.7 47.0 50.0 54.4 58.5 62.9 66.5 71.2 77.5

39.7 43.3 46.1 49.8 54.0 58.2 45.2 49.4 51.7 55.2 59.9 64.5 69.1 72.8 78.1 85.2

3260 4020 4760 5610 6820 8480 2660 3310 3960 4570 5610 6820 8070 9260 10960 13390

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

25.4 26.4 27.6 29.8 32.6 34.6 36.3 38.3 41.2 44.1 47.6 51.3 55.3 50.1 52.3 55.3 59.8 63.8 68.2 71.8 76.5

28.5 29.6 30.8 33.4 36.3 38.5 40.2 42.3 45.7 48.7 52.4 56.6 60.8 55.4 57.7 60.8 65.9 70.1 75.1 78.8 83.7

1150 1260 1510 1770 2270 2730 3020 3490 4260 4810 6160 7330 8800 3610 4510 5210 6390 7660 8810 10070 11420

www.addison-cables.com

ADDISON

11


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

3.8/6.6kV, 6.6/6.6kV, 6.35/11kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables (Non Radial Field) Application These medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards BS 6883  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 607542 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Stranded Tinned Copper Conductor Conductor Screen HF-EPR GP5 Insulation SW2/SW4 Inner Sheath Galvanized Steel Wire/Tinned Bronze Wire Braid SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Conductor Screen: Semiconducting layer or tape.  Insulation: HF-EPR GP5 according to BS 7655 1.2.  Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  Armour: Galvanized steel wire braid or tinned bronze wire braid (single core).  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

Mechanical and Thermal Properties Minimum Internal Bending Radius: 12×OD Temperature Range: -40℃ ~ +90℃ 12

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight 3.8/6.6kV Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 1×630 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240

3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4

6.6/6.6kV Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185

5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.3 13.9 15.7 1.3 15.5 17.5 1.4 16.6 18.6 1.4 17.8 19.8 1.5 19.7 22.1 1.6 21.6 24.1 1.6 23.2 25.8 1.7 24.9 27.6 1.8 26.9 29.6 1.9 29.6 32.8 2.0 32.1 35.4 2.1 35.5 38.9 2.2 38.7 42.6 42.6 46.6 2.4 1.8 28.1 30.9 2.0 31.9 35.2 2.0 33.8 37.1 2.2 36.8 40.2 2.3 40.7 44.6 2.5 44.7 48.8 2.6 48.6 53.1 2.7 51.9 56.6 2.9 56.2 61.1 3.1 62.0 67.4

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 1.4 1.5 1.5 1.6 1.7 1.8 1.8 1.9 2.0 2.1 2.2 2.4 2.5 2.7 2.1 2.2 2.3 2.4 2.6 2.8 2.9 3.1 3.2 3.5

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.5 19.9 22.4 1.5 20.8 23.3 1.6 22.2 24.7 1.7 24.1 26.7 1.7 25.8 28.5 1.8 27.7 30.4 1.9 29.3 32.5 1.9 31.1 34.3

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 1.7 1.7 1.8 1.9 2.0 2.0 2.1 2.2

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

18.0 19.8 20.9 22.3 24.4 26.5 28.1 30.7 32.9 35.8 38.5 42.2 45.7 49.9 34.3 38.3 40.4 43.5 47.9 52.3 56.3 60.1 64.6 70.9

20.4 22.7 23.8 25.2 27.4 29.6 31.3 34.4 36.7 39.7 42.9 46.8 50.4 55.2 38.2 42.3 44.9 48.2 52.7 57.7 61.8 66.2 70.8 77.9

703 899 1029 1223 1547 1903 2266 2760 3282 4059 4872 5844 7113 9093 2109 2747 3133 3772 4771 5900 7098 8304 9895 12358

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

24.6 25.5 27.1 29.9 31.8 33.7 35.5 37.5

27.7 28.6 30.2 33.6 35.5 37.5 39.4 41.5

1211 1338 1565 2017 2383 2794 3213 3737

www.addison-cables.com

ADDISON

13


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×240 1×300 1×400 1×500 1×630 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240

5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5

6.35/11kV Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 1×630 3×35 3×50 3×70 3×95 3×120 3×150 3×185

14

6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5

ADDISON

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 2.0 33.8 37.2 2.1 36.4 39.8 43.8 2.3 39.9 2.4 43.2 47.2 2.5 46.8 51.0 2.3 41.2 45.1 2.4 43.3 47.3 2.5 46.1 50.2 2.7 50.2 54.8 2.8 54.0 58.8 3.0 58.0 63.0 3.1 61.4 66.8 3.3 65.7 71.3 3.5 71.5 77.6

Nominal Armour Wire Diameter mm 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 2.3 2.4 2.6 2.7 2.8 2.6 2.7 2.8 3.0 3.1 3.3 3.4 3.6 3.9

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.6 22.9 25.5 1.7 24.3 26.9 1.7 26.0 28.7 1.8 27.9 30.7 1.9 29.8 32.9 1.9 31.2 34.5 2.0 33.3 36.5 2.1 36.0 39.4 2.2 38.5 42.3 2.4 42.0 46.0 2.5 45.3 49.4 2.6 48.9 53.5 2.6 47.8 52.0 2.7 50.6 55.2 2.8 54.5 59.3 3.0 58.6 63.5 3.1 62.4 67.8 3.3 66.0 71.5 3.4 70.1 76.1

Nominal Armour Wire Diameter mm 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 1.8 1.9 2.0 2.1 2.1 2.2 2.3 2.4 2.5 2.6 2.8 2.9 2.9 3.0 3.2 3.3 3.5 3.6 3.8

www.addison-cables.com

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

40.4 43.1 47.0 50.5 54.3 48.4 50.6 53.6 58.1 62.1 66.5 70.1 74.8 81.2

44.9 47.7 51.8 55.8 59.8 53.6 55.9 59.0 64.1 68.3 72.9 77.0 81.9 89.0

4548 5392 6384 7689 9709 3746 4204 4872 5992 7130 8486 9723 11448 14038

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

27.8 30.1 32.0 34.1 36.0 37.6 39.8 42.7 45.4 49.2 52.8 56.6 55.5 58.5 62.8 67.0 71.3 75.0 79.5

31.0 33.8 35.8 37.9 39.9 41.6 44.3 47.3 50.1 54.4 58.2 62.2 61.1 64.6 69.0 73.4 78.2 82.2 87.2

1514 1751 2201 2600 3021 3427 3987 4814 5674 6637 7986 10057 4793 5489 6612 7829 9182 10498 12218


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Fire Resistant Power & Control Cables www.caledonian-cables.co.uk

1.9/3.3kV, 3.3/3.3kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Fire Resistant Power & Control Cables Application These fire resistant medium voltage elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.

Standards BS 7917  IEC 60331-31 Fire resistant  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Stranded Tinned Copper Conductor Mica Tape+HF-EPR GP5 Insulation SB1 Inner Sheath Galvanized Steel Wire/Tinned Bronze Wire Braid SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228. Insulation: Mica tape + HF-EPR GP5 according to BS 7655 1.2.  Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.  Armour: Galvanized steel wire braid or tinned bronze wire braid (single core).  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  

Mechanical and Thermal Properties Minimum Internal Bending Radius: 6×OD Temperature Range: -40℃ ~ +90℃

www.addison-cables.com

ADDISON

15


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Fire Resistant Power & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight 1.9/3.3kV Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300 1×400 1×500 1×630 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 3×300

2.2 2.2 2.2 2.2 2.4 2.4 2.4 2.4 2.4 2.4 2.6 2.8 2.8 2.2 2.2 2.2 2.2 2.4 2.4 2.4 2.4 2.4 2.4

3.3/3.3kV Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240

16

3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0

ADDISON

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.2 13.4 15.2 1.3 14.4 16.4 1.3 15.6 17.6 1.4 17.6 19.6 1.5 19.8 22.3 1.6 21.7 24.2 1.6 23.2 25.8 1.7 25.2 27.8 1.8 27.9 30.7 1.9 30.4 33.6 2.0 34.1 37.5 2.2 38.0 41.5 2.3 41.6 45.6 27.4 30.1 1.8 1.8 29.3 32.4 1.9 32.1 35.3 2.1 36.2 39.6 2.3 41.0 44.9 2.4 44.9 48.9 2.6 48.4 53.0 2.7 52.5 57.2 3.0 58.5 63.8 3.2 64.0 69.4

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 1.4 1.4 1.5 1.6 1.7 1.7 1.8 1.9 2.0 2.1 2.3 2.5 2.6 2.0 2.1 2.2 2.4 2.6 2.7 2.9 3.0 3.3 3.5

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.3 15.1 17.1 1.3 16.0 18.0 1.4 17.4 19.4 1.5 19.3 21.7 1.5 21.0 23.5 1.6 22.9 25.4 1.7 24.5 27.2 1.7 26.3 29.0 1.8 29.0 32.2

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 1.5 1.5 1.6 1.6 1.7 1.8 1.9 2.0 2.1

www.addison-cables.com

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

17.5 18.6 20.0 22.1 24.5 26.4 28.8 31.0 33.9 36.6 40.7 44.9 48.8 33.4 35.5 38.4 42.9 48.2 52.2 56.2 60.5 67.0 72.8

19.9 21.0 22.8 25.0 27.6 29.5 32.0 34.7 37.7 40.5 45.2 49.6 54.0 37.2 39.3 42.8 47.5 53.4 57.6 61.7 66.6 73.4 79.9

687 806 983 1283 1637 1997 2439 2933 3671 4446 5435 6746 8583 2072 2422 2977 3920 5041 6165 7333 8800 11172 13587

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

19.4 20.3 21.9 23.8 25.7 27.8 30.3 32.3 35.2

22.3 23.2 24.8 26.8 28.8 30.9 34.0 36.1 39.1

789 900 1097 1392 1715 2097 2568 3050 3798


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Fire Resistant Power & Control Cables www.caledonian-cables.co.uk

Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×300 1×400 1×500 1×630 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 3×300

3.0 3.0 3.2 3.2 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.9 31.6 34.8 2.1 35.1 38.5 42.6 2.2 38.7 2.4 43.6 46.6 1.9 30.9 34.1 2.0 33.0 36.2 2.1 35.8 39.1 2.2 39.7 43.5 2.4 43.7 47.7 2.5 47.5 51.7 2.7 51.1 55.7 2.8 55.2 60.0 3.1 61.2 66.6 3.3 66.6 72.2

Nominal Armour Wire Diameter mm 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 2.2 2.3 2.5 2.6 2.1 2.2 2.3 2.5 2.7 2.8 3.0 3.2 3.4 3.6

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

37.9 41.7 45.7 49.7 37.1 39.4 42.3 46.6 51.1 55.1 59.0 63.5 69.9 75.7

41.9 46.2 50.4 55.0 41.1 43.8 46.9 51.4 56.4 60.6 65.1 69.8 76.8 82.9

4582 5533 6828 8712 2358 2747 3325 4274 5347 6493 7684 9213 11583 14031

www.addison-cables.com

ADDISON

17


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control Cables Application These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards BS 6883  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request)

Stranded Tinned Copper Conductor

HF-EPR GP4 Insulation SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Insulation: HF-EPR GP4 according to BS 7655 1.2.  Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

Mechanical and Thermal Properties Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm) Temperature Range: -40℃ ~ +90℃

18

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight Single core cables Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm 1×4 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300

1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4

Nominal Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.3 1.4 1.5 1.6 1.7 1.8 1.9

6.3 6.8 7.7 8.9 11.1 12.0 13.7 15.5 17.7 19.6 21.6 24.0 27.1 30.0

7.6 8.1 9.1 10.3 12.8 13.7 15.5 17.4 19.8 22.0 24.2 26.6 29.9 33.2

85 120 165 230 345 445 600 810 1100 1360 1650 2070 2670 3340

Nominal Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.5 1.6 1.7 1.9 2.1 2.2 1.1 1.1 1.1 1.2 1.2 1.3 1.4

7.5 8.2 9.0 11.0 12.1 14.1 16.3 20.4 22.4 25.7 29.6 34.1 37.7 8.2 8.7 9.6 11.7 12.9 15.0 17.4

8.8 9.6 10.4 12.7 13.8 15.9 18.3 22.9 24.9 28.4 32.7 37.4 41.1 9.5 10.1 11.0 13.4 14.7 17.0 19.4

100 125 160 235 300 415 590 890 1150 1570 2140 2930 3600 110 150 190 280 370 505 750

Multicore cables Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm 2×1 2×1.5 2×2.5 2×4 2×6 2×10 2×16 2×25 2×35 2×50 2×70 2×95 2×120 3×1 3×1.5 3×2.5 3×4 3×6 3×10 3×16

0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 0.8 0.8 0.8 1.0 1.0 1.0 1.0

www.addison-cables.com

ADDISON

19


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 3×300 4×1 4×1.5 4×2.5 4×4 4×6 4×10 4×16 4×25 4×35 4×50 4×70 4×95 4×120 4×150 4×185 4×240 5×1.5 7×1.5 12×1.5 19×1.5 27×1.5 37×1.5 5×2.5 7×2.5 12×2.5 19×2.5

20

ADDISON

1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

Nominal Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.6 1.7 1.8 2.0 2.2 2.3 2.5 2.7 2.9 3.2 1.1 1.1 1.1 1.2 1.3 1.4 1.5 1.7 1.8 1.9 2.1 2.3 2.5 2.7 2.9 3.2 1.1 1.2 1.3 1.4 1.6 1.7 1.2 1.2 1.4 1.5

22.0 24.1 27.7 31.8 36.7 40.5 44.9 50.1 56.7 63.1 8.9 9.5 10.5 12.9 14.4 16.7 19.4 24.5 26.8 30.8 35.4 40.8 45.2 50.1 55.8 63.4 10.4 11.5 15.2 18.0 21.9 24.7 11.7 12.7 17.1 20.2

24.6 26.7 30.5 35.1 40.1 44.4 49.0 54.6 61.5 68.6 10.3 10.9 12.1 14.6 16.2 18.7 21.8 27.1 29.5 34.0 38.8 44.7 49.3 54.7 60.7 68.9 12.0 13.2 17.2 20.1 24.5 27.3 13.3 14.4 19.1 22.7

1150 1490 2030 2790 3820 4710 5710 7180 9310 10860 140 175 225 340 465 640 960 1550 1920 2600 3570 4900 6070 7360 9260 12030 200 255 405 600 850 1120 270 335 550 830

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Flame Retardant Power & Control Cables Application These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications.

Standards BS 6883  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 607542 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Stranded Tinned Copper Conductor HF-EPR GP4 Insulation SW2/SW4 Inner Sheath Galvanized Steel Wire/Tinned Bronze Wire Braid SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Insulation: HF-EPR GP4 according to BS 7655 1.2.  Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  Armour: Galvanized steel wire braid or tinned bronze wire braid (single core). Copper wire braid can be offered upon request.  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

Mechanical and Thermal Properties Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm) Temperature Range: -40℃ ~ +90℃

www.addison-cables.com

ADDISON

21


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight Single core cables Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 1×4 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300

1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4

Multicore cables Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 2×1 2×1.5 2×2.5 2×4 2×6 2×10 2×16 2×25 2×35 2×50 2×70 2×95 2×120 3×1 3×1.5 3×2.5 3×4 3×6

22

0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 0.8 0.8 0.8 1.0 1.0

ADDISON

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.0 6.3 7.6 1.0 6.8 8.1 9.1 1.0 7.7 1.1 8.9 10.3 1.2 11.1 12.8 1.2 12.0 13.7 1.3 13.7 15.5 1.3 15.5 17.4 1.4 17.7 19.8 1.5 19.6 22.0 1.6 21.6 24.2 1.7 24.0 26.6 1.8 27.1 29.9 1.9 30.0 33.2

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 1.1 1.1 1.2 1.2 1.3 1.4 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.0 7.5 8.8 1.1 8.2 9.6 1.1 9.0 10.4 1.2 11.0 12.7 1.2 12.1 13.8 1.3 14.1 15.9 1.4 16.3 18.3 1.5 20.4 22.9 1.6 22.4 24.9 1.7 25.7 28.4 1.9 29.6 32.7 2.1 34.1 37.4 2.2 37.7 41.1 1.1 8.2 9.5 1.1 8.7 10.1 1.1 9.6 11.0 1.2 11.7 13.4 1.2 12.9 14.7

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.3 0.3 0.3 0.3 0.3

Nominal Outer Sheath Thickness mm 1.2 1.2 1.2 1.3 1.4 1.4 1.5 1.7 1.8 2.0 2.1 2.3 2.5 1.2 1.2 1.3 1.3 1.4

www.addison-cables.com

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

9.8 10.4 11.5 12.7 15.0 16.1 17.9 19.8 22.2 24.3 26.5 29.8 33.1 36.2

11.7 12.2 13.4 14.6 17.3 18.4 20.2 22.6 25.2 27.3 29.7 33.5 36.9 40.1

220 250 310 400 570 660 870 1110 1460 1770 2110 2720 3410 4180

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

11.3 12.0 12.8 15.0 16.3 18.2 20.6 25.2 27.3 31.7 35.8 40.7 44.6 11.9 12.5 13.5 15.7 17.0

13.1 13.9 14.7 17.2 18.5 20.6 23.5 28.2 30.4 35.5 39.7 45.2 49.3 13.8 14.4 15.5 17.9 19.4

230 270 320 430 530 660 840 1310 1600 2240 2900 3860 4650 250 305 360 495 600


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm 3×10 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 3×300 4×1 4×1.5 4×2.5 4×4 4×6 4×10 4×16 4×25 4×35 4×50 4×70 4×95 4×120 4×150 4×185 4×240 5×1.5 7×1.5 12×1.5 19×1.5 27×1.5 37×1.5 5×2.5 7×2.5 12×2.5 19×2.5

1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4 0.8 0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.3 15.0 17.0 1.4 17.4 19.4 1.6 22.0 24.6 1.7 24.1 26.7 1.8 27.7 30.5 2.0 31.8 35.1 2.2 36.7 40.1 2.3 40.5 44.4 2.5 44.9 49.0 2.7 50.1 54.6 2.9 56.7 61.5 3.2 63.1 68.6 1.1 8.9 10.3 9.5 10.9 1.1 1.1 10.5 12.1 1.2 12.9 14.6 1.3 14.4 16.2 1.4 16.7 18.7 1.5 19.4 21.8 1.7 24.5 27.1 1.8 26.8 29.5 1.9 30.8 34.0 2.1 35.4 38.8 2.3 40.8 44.7 49.3 2.5 45.2 2.7 50.1 54.7 2.9 55.8 60.7 3.2 63.4 68.9 1.1 10.4 12.0 1.2 11.5 13.2 1.3 15.2 17.2 1.4 18.0 20.1 1.6 21.9 24.5 1.7 24.7 27.3 1.2 11.7 13.3 1.2 12.7 14.4 1.4 17.1 19.1 1.5 20.2 22.7

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3

Nominal Outer Sheath Thickness mm 1.5 1.6 1.8 1.9 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.5 1.2 1.3 1.3 1.4 1.5 1.6 1.7 1.9 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.5 1.3 1.3 1.5 1.6 1.8 1.9 1.3 1.4 1.6 1.7

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

19.4 21.9 26.9 29.9 33.7 38.2 43.5 47.7 52.5 58.0 65.0 72.0 12.6 13.5 14.4 17.0 18.7 21.3 24.1 30.3 32.8 37.2 42.2 47.9 52.8 58.1 64.1 72.3 14.3 15.4 19.6 22.5 26.8 30.5 15.6 16.8 21.6 24.9

22.2 24.8 30.1 33.6 37.5 42.2 48.1 52.5 57.8 64.0 71.3 79.0 14.6 15.4 16.4 19.3 21.1 24.1 27.1 34.0 36.6 41.2 46.7 52.7 58.2 64.1 70.4 79.3 16.3 17.7 22.4 25.5 30.0 34.2 17.8 19.1 24.5 28.0

810 1070 1620 2130 2750 3660 4740 5950 7120 8820 11280 13640 280 350 410 570 730 990 1330 2150 2600 3410 4530 5940 7390 8700 10780 13840 395 460 680 930 1270 1740 480 570 880 1220

www.addison-cables.com

ADDISON

23


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Fire Resistant Power & Control Cables www.caledonian-cables.co.uk

0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Fire Resistant Power & Control Cables Application These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.

Standards BS 7917  IEC 60331-31 Fire resistant  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request)

Stranded Tinned Copper Conductor

Mica Tape+HF-EPR GP4 Insulation SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.  Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

Mechanical and Thermal Properties Minimum Internal Bending Radius: 6×OD (OD>25mm); 4×OD (OD ≤25mm) Temperature Range: -40℃ ~ +90℃

24

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Fire Resistant Power & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight Single core cables Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm 1×4 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300

1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4

Nominal Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.0 1.0 1.0 1.1 1.2 1.2 1.3 1.3 1.4 1.5 1.6 1.7 1.8 1.9

6.7 7.2 8.1 9.3 11.5 12.3 14.1 15.8 18.1 20.0 22.0 24.4 27.5 30.4

8.0 8.5 9.5 10.7 13.2 14.1 15.9 17.8 20.2 22.4 24.6 27.0 30.3 33.6

90 135 180 315 550 715 830 1110 1470 2130 2475 2870 3120 4060

Nominal Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.1 1.1 1.2 1.2 1.3 1.4 1.5 1.6 1.7 1.9 2.1 2.2 1.1 1.1 1.2 1.2 1.3 1.4 1.6 1.7

9.0 9.8 11.8 12.9 14.9 17.1 21.2 23.1 26.5 30.3 34.9 38.4 9.6 10.4 12.6 13.8 15.9 18.2 22.9 24.9

10.4 11.4 13.5 14.6 16.8 19.1 23.7 25.7 29.2 33.5 38.2 42.2 11.0 12.1 14.3 15.5 17.8 20.3 25.4 27.6

145 180 260 325 445 630 930 1210 1630 2210 3010 3690 170 210 310 395 590 830 1270 1540

Multicore cables Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm 2×1.5 2×2.5 2×4 2×6 2×10 2×16 2×25 2×35 2×50 2×70 2×95 2×120 3×1.5 3×2.5 3×4 3×6 3×10 3×16 3×25 3×35

0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2

www.addison-cables.com

ADDISON

25


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Fire Resistant Power & Control Cables www.caledonian-cables.co.uk

Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm 3×50 3×70 3×95 3×120 3×150 3×185 3×240 4×1.5 4×2.5 4×4 4×6 4×10 4×16 4×25 4×35 4×50 4×70 4×95 4×120 5×1.5 7×1.5 12×1.5 19×1.5 27×1.5 37×1.5 5×2.5 7×2.5 12×2.5 19×2.5

26

ADDISON

1.4 1.4 1.6 1.6 1.8 2.0 2.2 0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

Nominal Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.8 2.0 2.2 2.3 2.5 2.7 2.9 1.1 1.1 1.2 1.3 1.4 1.5 1.7 1.8 1.9 2.1 2.3 2.5 1.1 1.2 1.3 1.4 1.6 1.7 1.2 1.2 1.4 1.5

28.5 32.7 37.5 41.3 45.8 50.9 57.5 10.5 11.4 13.8 15.3 17.7 20.3 25.5 27.7 31.8 36.3 41.7 46.2 11.4 12.6 16.8 19.9 24.3 27.4 12.7 13.9 18.7 22.1

31.3 35.9 41.0 45.3 49.9 55.5 62.4 12.1 13.1 15.6 17.3 19.7 22.8 28.1 30.5 35.0 39.7 45.7 50.3 13.1 14.4 18.8 22.4 26.9 30.4 14.4 15.6 20.8 24.7

2100 2870 3910 4800 5810 7290 9440 200 250 375 495 740 1050 1580 1960 2570 3530 4850 5990 220 285 465 680 960 1260 310 375 610 895

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Fire Resistant Power & Control Cables www.caledonian-cables.co.uk

0.6/1kV HF-EPR Insulated, SW2/SW4 Sheathed Armoured Fire Resistant Power & Control Cables Application These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in power and control applications where fire integrity is essential.

Standards BS 7917  IEC 60331-31 Fire resistant  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Stranded Tinned Copper Conductor Mica Tape+HF-EPR GP4 Insulation SB1 Inner Sheath Galvanized Steel Wire/Tinned Bronze Wire Braid SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.  Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.  Armour: Galvanized steel wire braid or tinned bronze wire braid (single core). Copper wire braid can be offered upon request.  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

Mechanical and Thermal Properties Minimum Internal Bending Radius: 6×OD Temperature Range: -40℃ ~ +90℃

www.addison-cables.com

ADDISON

27


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Fire Resistant Power & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight Single core cables Construction No. of cores×Cross section(mm²)

Nominal Insulation Thickness mm

1×4 1×6 1×10 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150 1×185 1×240 1×300

1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 2.4

Multicore cables Construction No. of cores×Cross section(mm²)

Nominal Insulation Thickness mm

2×1.5 2×2.5 2×4 2×6 2×10 2×16 2×25 2×35 2×50 2×70 2×95 2×120 3×1.5 3×2.5 3×4 3×6 3×10 3×16

0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 0.8 0.8 1.0 1.0 1.0 1.0

28

ADDISON

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.0 6.7 8.0 1.0 7.2 8.5 1.0 8.1 9.5 1.1 9.3 10.7 1.2 11.5 13.2 1.2 12.3 14.1 1.3 14.1 15.9 1.3 15.8 17.8 1.4 18.1 20.2 1.5 20.0 22.4 1.6 22.0 24.6 1.7 24.4 27.0 1.8 27.5 30.3 1.9 30.4 33.6

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45

Nominal Outer Sheath Thickness mm 1.1 1.1 1.2 1.2 1.3 1.4 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.1 9.0 10.4 1.1 9.8 11.4 1.2 11.8 13.5 1.2 12.9 14.6 1.3 14.9 16.8 1.4 17.1 19.1 1.5 21.2 23.7 1.6 23.1 25.7 1.7 26.5 29.2 1.9 30.3 33.5 2.1 34.9 38.2 2.2 38.4 42.2 1.1 9.6 11.0 1.1 10.4 12.1 1.2 12.6 14.3 1.2 13.8 15.5 1.3 15.9 17.8 1.4 18.2 20.3

Nominal Armour Wire Diameter mm 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.3 0.3 0.3 0.3 0.3 0.3

Nominal Outer Sheath Thickness mm 1.2 1.2 1.3 1.4 1.4 1.5 1.7 1.8 2.0 2.1 2.3 2.5 1.2 1.3 1.3 1.4 1.5 1.6

www.addison-cables.com

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

10.2 10.8 11.9 13.1 15.4 16.5 18.2 20.2 22.6 24.7 26.9 30.2 33.5 36.6

12.1 12.6 13.8 15.0 17.7 18.8 20.6 23.0 25.6 27.7 30.1 33.9 37.3 40.5

245 275 355 440 600 720 910 1170 1510 1830 2160 2790 3530 4280

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

12.7 13.6 15.7 17.0 19.0 21.4 25.9 28.0 32.5 36.5 41.4 45.4 13.3 14.4 16.5 17.9 20.2 22.8

14.7 15.5 18.0 19.3 21.4 24.3 29.0 31.2 36.3 40.5 46.0 50.1 15.3 16.4 18.8 20.2 23.0 25.7

310 355 475 580 750 980 1380 1710 2370 3100 4020 4870 345 405 540 660 910 1200


BS 6883&BS 7917 Caledonian Offshore & Marine Cables LV Fire Resistant Power & Control Cables www.caledonian-cables.co.uk

Construction No. of cores×Cross section(mm²)

Nominal Insulation Thickness mm

3×25 3×35 3×50 3×70 3×95 3×120 3×150 3×185 3×240 4×1.5 4×2.5 4×4 4×6 4×10 4×16 4×25 4×35 4×50 4×70 4×95 4×120 5×1.5 7×1.5 12×1.5 19×1.5 27×1.5 37×1.5 5×2.5 7×2.5 12×2.5 19×2.5

1.2 1.2 1.4 1.4 1.6 1.6 1.8 2.0 2.2 0.8 0.8 1.0 1.0 1.0 1.0 1.2 1.2 1.4 1.4 1.6 1.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

Nominal Minimum Maximum Inner Diameter Diameter Sheath Over Inner Over Inner Thickness Sheath Sheath mm mm mm 1.6 22.9 25.4 1.7 24.9 27.6 1.8 28.5 31.3 2.0 32.7 35.9 2.2 37.5 41.0 2.3 41.3 45.3 2.5 45.8 49.9 2.7 50.9 55.5 2.9 57.5 62.4 1.1 10.5 12.1 1.1 11.4 13.1 1.2 13.8 15.6 1.3 15.3 17.3 19.7 1.4 17.7 1.5 20.3 22.8 1.7 25.5 28.1 1.8 27.7 30.5 1.9 31.8 35.0 2.1 36.3 39.7 2.3 41.7 45.7 2.5 46.2 50.3 1.1 11.4 13.1 1.2 12.6 14.4 1.3 16.8 18.8 1.4 19.9 22.4 1.6 24.3 26.9 1.7 27.4 30.4 1.2 12.7 14.4 1.2 13.9 15.6 1.4 18.7 20.8 1.5 22.1 24.7

Nominal Armour Wire Diameter mm 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.3 0.3 0.3 0.3 0.3 0.3 0.45 0.45 0.45 0.45 0.45 0.45 0.3 0.3 0.3 0.3 0.3 0.45 0.3 0.3 0.3 0.3

Nominal Outer Sheath Thickness mm 1.8 1.9 2.0 2.2 2.4 2.6 2.8 3.0 3.2 1.3 1.3 1.4 1.5 1.6 1.7 1.9 2.0 2.2 2.4 2.6 2.8 1.3 1.3 1.5 1.6 1.8 1.9 1.3 1.4 1.6 1.7

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

27.8 30.7 34.5 39.0 44.3 48.5 53.3 58.8 65.8 14.4 15.4 17.9 19.6 22.2 25.0 31.3 33.7 38.1 43.1 48.9 53.7 15.4 16.6 21.2 24.4 29.2 33.2 16.6 18.0 23.2 26.8

30.9 34.4 38.4 43.5 48.9 53.7 58.7 64.9 72.2 16.4 17.6 20.3 22.5 25.1 28.1 35.0 37.5 42.1 47.7 54.1 59.2 17.6 18.9 24.0 27.5 32.8 37.0 18.9 20.3 26.2 30.0

1760 2260 2880 3800 4890 6070 7270 8970 1350 395 465 640 790 1070 1460 2140 2670 3630 4740 6290 7670 455 530 790 1080 1460 1990 560 650 970 1360

www.addison-cables.com

ADDISON

29


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flame Retardant Instrumentation & Control Cables www.caledonian-cables.co.uk

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Unarmoured Flame Retardant Instrumentation & Control Cables Application These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits.

Standards

Stranded Tinned Copper Conductor

BS 6883  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

HF-EPR GP4 Insulation Aluminium/Polyester Tape + Drain Wire SW4/SW2 Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Insulation: HF-EPR GP4 according to BS 7655 1.2.  Lay-up: Pairs, triples, quads.  Individual Screen: Aluminium/polyester tape + drain wire tinned copper.  Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

Mechanical and Thermal Properties Minimum Internal Bending Radius: 8×OD Temperature Range: -40℃ ~ +90℃

30

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flame Retardant Instrumentation & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm

Nominal Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

7.3 12.6 16.9 21.2 27.0 30.8 35.9 7.7 13.5 18.0 22.8 28.8 32.8 38.5

9.0 14.5 19.0 23.7 29.8 33.9 39.3 9.5 15.5 20.1 25.4 31.6 36.0 42.3

90 200 390 630 1010 1320 1560 100 240 470 780 1230 1630 2180

7.7 14.2 19.7 24.4 8.4 15.0 21.0 26.2

9.4 16.2 22.1 27.1 10.1 17.2 23.5 28.9

100 250 500 830 120 300 610 1020

8.6 16.4 22.1 9.1 17.5 23.6

10.4 18.5 24.7 10.9 19.6 26.2

120 310 620 140 360 740

Multipair 1×2×0.75 3×2×0.75 7×2×0.75 12×2×0.75 20×2×0.75 27×2×0.75 37×2×0.75 1×2×1 3×2×1 7×2×1 12×2×1 20×2×1 27×2×1 37×2×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1.0 1.2 1.4 1.6 1.9 2.0 2.2 1.0 1.3 1.4 1.7 1.9 2.1 2.3

1×3×0.75 3×3×0.75 7×3×0.75 12×3×0.75 1×3×1 3×3×1 7×3×1 12×3×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1.0 1.3 1.5 1.7 1.1 1.3 1.5 1.8

1×4×0.75 3×4×0.75 7×4×0.75 1×4×1 3×4×1 7×4×1

0.8 0.8 0.8 0.8 0.8 0.8

1.1 1.4 1.6 1.1 1.4 1.6

Multitriple

Multiquad

www.addison-cables.com

ADDISON

31


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flame Retardant Instrumentation & Control Cables www.caledonian-cables.co.uk

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation & Control Cables Application These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits.

Standards

Stranded Tinned Copper Conductor

BS 6883  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

HF-EPR GP4 Insulation Aluminium/Polyester Tape + Drain Wire SW4/SW2 Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Insulation: HF-EPR GP4 according to BS 7655 1.2.  Lay-up: Pairs, triples.  Collective Screen: Aluminium/polyester tape + drain wire tinned copper.  Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

Mechanical and Thermal Properties Minimum Internal Bending Radius: 8×OD Temperature Range: -40℃ ~ +90℃

32

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flame Retardant Instrumentation & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm

Nominal Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

12.6 16.6 21.7 27.3 31.1 34.4 13.3 17.6 23.1 29.1 33.3 36.9

14.5 18.7 24.2 30.1 34.2 37.7 15.3 19.8 25.7 31.9 36.6 40.3

175 330 530 830 1070 1430 185 360 590 920 1220 1630

14.2 19.4 24.2 15.1 20.9 25.8

16.2 21.9 26.8 17.1 23.4 28.5

230 440 730 260 510 840

Multipair 3×2×0.75 7×2×0.75 12×2×0.75 20×2×0.75 27×2×0.75 37×2×0.75 3×2×1 7×2×1 12×2×1 20×2×1 27×2×1 37×2×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1.2 1.4 1.6 1.8 1.9 2.1 1.2 1.4 1.6 1.8 2.0 2.2

3×3×0.75 7×3×0.75 12×3×0.75 3×3×1 7×3×1 12×3×1

0.8 0.8 0.8 0.8 0.8 0.8

1.3 1.4 1.7 1.3 1.5 1.7

Multitriple

www.addison-cables.com

ADDISON

33


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flame Retardant Instrumentation & Control Cables www.caledonian-cables.co.uk

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Armoured Flame Retardant Instrumentation & Control Cables Application These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits.

Standards BS 6883  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Stranded Tinned Copper Conductor HF-EPR GP4 Insulation Aluminium/Polyester Tape + Drain Wire SW2/SW4 Inner Sheath Galvanized Steel Wire Braid SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Insulation: HF-EPR GP4 according to BS 7655 1.2.  Lay-up: Pairs, triples, quads.  Individual Screen: Aluminium/polyester tape + drain wire tinned copper.  Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  Armour: Galvanized steel wire braid. Tinned bronze wire braid can be offered upon request.  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

34

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flame Retardant Instrumentation & Control Cables www.caledonian-cables.co.uk

Mechanical and Thermal Properties Minimum Internal Bending Radius: 8×OD Temperature Range: -40℃ ~ +90℃

Dimensions and Weight Construction No. of cores×Cross section(mm²)

Nominal Insulation Thickness mm

1×2×0.75 3×2×0.75 7×2×0.75 12×2×0.75 20×2×0.75 27×2×0.75 37×2×0.75 1×2×1 3×2×1 7×2×1 12×2×1 20×2×1 27×2×1 37×2×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1×3×0.75 3×3×0.75 7×3×0.75 12×3×0.75 1×3×1 3×3×1 7×3×1 12×3×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1×4×0.75 3×4×0.75 7×4×0.75 1×4×1 3×4×1 7×4×1

0.8 0.8 0.8 0.8 0.8 0.8

Nominal Minimum Maximum Nominal Inner Diameter Diameter Armour Sheath Over Inner Over Inner Wire Thickness Sheath Sheath Diameter mm mm mm mm Multipair 1.0 7.3 9.0 0.3 1.2 12.6 14.5 0.3 1.4 16.9 19.0 0.3 1.6 21.3 23.7 0.3 1.9 27.0 29.8 0.45 2.0 30.8 33.9 0.45 2.2 35.9 39.3 0.45 1.0 7.7 9.5 0.3 1.3 13.5 15.5 0.3 1.4 18.0 20.1 0.3 1.7 22.8 25.4 0.45 1.9 28.8 31.6 0.45 32.8 36.0 0.45 2.1 2.3 38.5 42.3 0.45 Multitriple 1.0 7.7 9.4 0.3 1.3 14.2 16.2 0.3 1.5 19.7 22.1 0.3 1.7 24.4 27.1 0.45 1.1 8.4 10.1 0.3 1.3 15.0 17.2 0.3 1.5 21.0 23.5 0.3 1.8 26.2 28.9 0.45 Multiquad 1.1 8.6 10.4 0.3 1.4 16.4 18.5 0.3 1.6 22.1 24.7 0.3 1.1 9.1 10.9 0.3 1.4 17.5 19.6 0.3 1.6 23.6 26.2 0.45

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.2 1.4 1.6 1.8 2.1 2.3 2.5 1.2 1.4 1.6 1.9 2.2 2.4 2.6

11.1 16.7 21.4 26.1 33.2 37.3 42.9 11.5 17.6 22.5 28.6 35.2 39.5 45.7

12.9 19.0 24.3 29.2 37.0 41.3 47.5 13.4 20.0 25.4 31.8 39.0 44.0 50.4

250 440 730 1090 1750 2190 2780 260 490 810 1370 2010 2570 3290

1.2 1.5 1.7 2.0 1.2 1.5 1.7 2.0

11.5 18.6 24.4 30.4 12.1 19.4 25.7 32.2

13.3 20.9 27.4 34.1 14.0 22.3 28.8 36.0

270 540 910 1500 290 600 1030 1740

1.2 1.5 1.7 1.2 1.6 1.8

12.4 20.9 27.0 12.9 22.0 29.4

14.3 23.8 30.2 14.8 24.9 32.0

290 610 1060 330 680 1290

www.addison-cables.com

ADDISON

35


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flame Retardant Instrumentation & Control Cables www.caledonian-cables.co.uk

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Armoured Flame Retardant Instrumentation & Control Cables Application These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits.

Standards BS 6883  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Stranded Tinned Copper Conductor HF-EPR GP4 Insulation Aluminium/Polyester Tape + Drain Wire SW2/SW4 Inner Sheath Galvanized Steel Wire Braid SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.  Insulation: HF-EPR GP4 according to BS 7655 1.2.  Lay-up: Pairs, triples.  Collective Screen: Aluminium/polyester tape + drain wire tinned copper.  Inner Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  Armour: Galvanized steel wire braid. Tinned bronze wire braid can be offered upon request.  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6. 

36

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flame Retardant Instrumentation & Control Cables www.caledonian-cables.co.uk

Mechanical and Thermal Properties Minimum Internal Bending Radius: 8×OD Temperature Range: -40℃ ~ +90℃

Dimensions and Weight Construction No. of cores×Cross section(mm²)

Nominal Insulation Thickness mm

3×2×0.75 7×2×0.75 12×2×0.75 20×2×0.75 27×2×0.75 37×2×0.75 3×2×1 7×2×1 12×2×1 20×2×1 27×2×1 37×2×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

3×3×0.75 7×3×0.75 12×3×0.75 3×3×1 7×3×1 12×3×1

0.8 0.8 0.8 0.8 0.8 0.8

Nominal Minimum Maximum Nominal Inner Diameter Diameter Armour Sheath Over Inner Over Inner Wire Thickness Sheath Sheath Diameter mm mm mm mm Multipair 1.2 12.6 14.5 0.3 1.4 16.6 18.7 0.3 1.6 21.7 24.2 0.3 1.8 27.3 30.1 0.45 1.9 31.1 34.2 0.45 2.1 34.4 37.7 0.45 1.2 13.3 15.3 0.3 1.4 17.6 19.8 0.3 1.6 23.1 25.7 0.3 1.8 29.0 31.9 0.45 2.0 33.3 36.6 0.45 2.2 36.9 40.3 0.45 Multitriple 1.3 14.2 16.2 0.3 1.4 19.4 21.9 0.3 1.7 24.2 26.8 0.45 1.3 15.1 17.1 0.3 1.5 20.9 23.4 0.3 1.7 25.8 28.5 0.45

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.4 1.5 1.7 2.0 2.2 2.3 1.4 1.6 1.8 2.1 2.2 2.4

16.7 20.9 26.4 33.3 37.4 41.0 17.4 22.1 28.0 35.3 39.7 43.7

19.0 23.8 29.5 37.1 41.4 45.5 19.8 25.1 31.2 39.2 44.2 48.3

390 620 930 1460 1810 2270 410 680 1010 1600 2000 2540

1.4 1.6 1.9 1.5 1.7 2.0

18.3 24.0 29.3 19.4 25.6 31.8

20.7 27.0 32.9 22.2 28.7 35.5

480 780 1320 530 890 1480

www.addison-cables.com

ADDISON

37


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Fire Resistant Instrumentation & Control Cables www.caledonian-cables.co.uk

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Unarmoured Fire Resistant Instrumentation & Control Cables Application These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.

Standards

Stranded Tinned Copper Conductor

BS 7917  IEC 60331-31 Fire resistant  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Mica Tape+HF-EPR GP4 Insulation Aluminium/Polyester Tape + Drain Wire SW4/SW2 Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228. Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.  Lay-up: Pairs, triples, quads.  Individual Screen: Aluminium/polyester tape + drain wire tinned copper.  Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  

Mechanical and Thermal Properties Minimum Internal Bending Radius: 8×OD Temperature Range: -40℃ ~ +90℃

38

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flire Resistant Instrumentation & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm

Nominal Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

8.1 14.0 19.0 23.8 30.4 34.6 40.5 8.5 15.0 20.0 25.4 32.1 36.8 43.0

9.8 16.0 21.1 26.4 33.5 37.9 44.3 10.3 17.0 22.5 28.0 35.3 40.2 47.0

97 227 449 740 1183 1555 1846 108 264 522 865 1377 1814 2432

8.1 15.0 20.8 25.8 8.7 15.8 22.0 27.5

9.8 17.0 23.3 28.5 10.5 17.9 24.5 30.2

104 269 527 880 124 310 622 1032

9.1 17.4 23.5 9.6 18.4 24.9

10.9 19.5 26.1 11.4 20.6 27.6

137 366 725 148 413 843

Multipair 1×2×0.75 3×2×0.75 7×2×0.75 12×2×0.75 20×2×0.75 27×2×0.75 37×2×0.75 1×2×1 3×2×1 7×2×1 12×2×1 20×2×1 27×2×1 37×2×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1.0 1.2 1.4 1.6 1.9 2.0 2.2 1.0 1.3 1.4 1.7 1.9 2.1 2.3

1×3×0.75 3×3×0.75 7×3×0.75 12×3×0.75 1×3×1 3×3×1 7×3×1 12×3×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1.0 1.3 1.5 1.7 1.1 1.3 1.5 1.8

1×4×0.75 3×4×0.75 7×4×0.75 1×4×1 3×4×1 7×4×1

0.8 0.8 0.8 0.8 0.8 0.8

1.1 1.4 1.6 1.1 1.4 1.6

Multitriple

Multiquad

www.addison-cables.com

ADDISON

39


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Fire Resistant Instrumentation & Control Cables www.caledonian-cables.co.uk

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Unarmoured Fire Resistant Instrumentation & Control Cables Application These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.

Standards

Stranded Tinned Copper Conductor

BS 7917  IEC 60331-31 Fire resistant  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Mica Tape+HF-EPR GP4 Insulation Aluminium/Polyester Tape + Drain Wire SW4/SW2 Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228. Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.  Lay-up: Pairs, triples.  Collective Screen: Aluminium/polyester tape + drain wire tinned copper.  Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  

Mechanical and Thermal Properties Minimum Internal Bending Radius: 8×OD Temperature Range: -40℃ ~ +90℃

40

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flire Resistant Instrumentation & Control Cables www.caledonian-cables.co.uk

Dimensions and Weight Construction Nominal Insulation No. of cores×Cross Thickness section(mm²) mm

Nominal Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

14.0 18.6 24.4 30.8 35.0 38.8 14.8 19.6 25.8 32.6 37.3 41.3

16.0 20.7 27.0 34.0 38.4 42.6 16.8 22.0 28.5 35.8 40.8 45.2

202 383 615 841 1265 1707 208 413 683 1070 1421 1912

15.0 20.5 25.6 15.8 21.9 27.1

17.0 23.0 28.3 17.8 24.4 29.8

244 457 758 270 521 857

Multipair 3×2×0.75 7×2×0.75 12×2×0.75 20×2×0.75 27×2×0.75 37×2×0.75 3×2×1 7×2×1 12×2×1 20×2×1 27×2×1 37×2×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1.2 1.4 1.6 1.8 1.9 2.1 1.2 1.4 1.6 1.8 2.0 2.2

3×3×0.75 7×3×0.75 12×3×0.75 3×3×1 7×3×1 12×3×1

0.8 0.8 0.8 0.8 0.8 0.8

1.3 1.4 1.7 1.3 1.5 1.7

Multitriple

www.addison-cables.com

ADDISON

41


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Fire Resistant Instrumentation & Control Cables www.caledonian-cables.co.uk

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Individually Screened Armoured Fire Resistant Instrumentation & Control Cables Application These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.

Standards BS 7917  IEC 60331-31 Fire resistant  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Stranded Tinned Copper Conductor Mica Tape+HF-EPR GP4 Insulation Aluminium/Polyester Tape + Drain Wire SB1 Inner Sheath Galvanized Steel Wire Braid SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228. Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.  Lay-up: Pairs, triples.  Individual Screen: Aluminium/polyester tape + drain wire tinned copper.  Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.  Armour: Galvanized steel wire braid. Tinned bronze wire braid can be offered upon request.  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  

42

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flire Resistant Instrumentation & Control Cables www.caledonian-cables.co.uk

Mechanical and Thermal Properties Minimum Internal Bending Radius: 8×OD Temperature Range: -40℃ ~ +90℃

Dimensions and Weight Construction No. of cores×Cross section(mm²)

Nominal Insulation Thickness mm

1×2×0.75 3×2×0.75 7×2×0.75 12×2×0.75 20×2×0.75 27×2×0.75 37×2×0.75 1×2×1 3×2×1 7×2×1 12×2×1 20×2×1 27×2×1 37×2×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1×3×0.75 3×3×0.75 7×3×0.75 12×3×0.75 1×3×1 3×3×1 7×3×1 12×3×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

1×4×0.75 3×4×0.75 7×4×0.75 1×4×1 3×4×1 7×4×1

0.8 0.8 0.8 0.8 0.8 0.8

Nominal Minimum Maximum Nominal Inner Diameter Diameter Armour Sheath Over Inner Over Inner Wire Thickness Sheath Sheath Diameter mm mm mm mm Multipair 1.0 8.1 9.8 0.3 1.2 14.0 16.0 0.3 1.4 19.0 21.1 0.3 1.6 23.8 26.4 0.3 1.9 30.4 33.5 0.45 2.0 34.6 37.9 0.45 2.2 40.5 44.3 0.45 1.0 8.5 10.3 0.3 1.3 15.0 17.0 0.3 1.4 20.0 22.5 0.3 1.7 25.4 28.0 0.45 1.9 32.1 35.3 0.45 40.2 0.45 2.1 36.8 2.3 43.0 47.0 0.45 Multitriple 1.0 8.1 9.8 0.3 1.3 15.0 17.0 0.3 1.5 20.8 23.3 0.3 1.7 25.8 28.5 0.45 1.1 8.7 10.5 0.3 1.3 15.8 17.9 0.3 1.5 22.0 24.5 0.3 1.8 27.5 30.2 0.45 Multiquad 1.1 9.1 10.9 0.3 1.4 17.4 19.5 0.3 1.6 23.5 26.1 0.3 1.1 9.6 11.4 0.3 1.4 18.4 20.6 0.3 1.6 24.9 27.6 0.45

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.2 1.4 1.6 1.8 2.1 2.3 2.5 1.2 1.4 1.6 1.9 2.2 2.4 2.6

11.9 18.1 23.5 28.7 36.5 41.2 47.4 12.3 19.1 24.5 31.2 38.5 43.6 50.2

13.7 20.5 26.4 31.9 40.5 45.7 52.2 14.2 21.5 27.6 34.9 42.9 48.2 55.5

270 500 840 1280 2050 2580 3290 280 540 900 1520 2250 2860 3670

1.2 1.5 1.7 2.0 1.2 1.5 1.7 2.0

11.9 19.3 25.5 31.8 12.5 20.1 26.7 33.5

13.7 22.1 28.6 35.6 14.4 23.0 29.8 37.3

280 580 960 1590 300 620 1050 1760

1.2 1.5 1.7 1.2 1.6 1.8

12.8 21.9 28.4 13.3 22.9 30.8

14.8 24.8 31.6 15.3 25.9 34.0

330 720 1240 350 780 1470

www.addison-cables.com

ADDISON

43


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Fire Resistant Instrumentation & Control Cables www.caledonian-cables.co.uk

150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Armoured Fire Resistant Instrumentation & Control Cables Application These fire resistant elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits where fire integrity is essential.

Standards BS 7917  IEC 60331-31 Fire resistant  IEC 60332-3A Flame retardant  IEC 60754-1; IEC 60754-2 Corrosivity  IEC 61034-2 Smoke density  Cold bend and impact (-40°C) (on request)  CSA C22.2 No. 38-95 (on request) 

Stranded Tinned Copper Conductor Mica Tape+HF-EPR GP4 Insulation Aluminium/Polyester Tape + Drain Wire SB1 Inner Sheath Galvanized Steel Wire Braid SW2/SW4 Outer Sheath

Construction Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228. Insulation: Mica tape + HF-EPR GP4 according to BS 7655 1.2.  Lay-up: Pairs, triples.  Collective Screen: Aluminium/polyester tape + drain wire tinned copper.  Inner Sheath: Halogen free thermosetting compound SB1 according to BS 7917.  Armour: Galvanized steel wire braid. Tinned bronze wire braid can be offered upon request.  Outer Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.  

44

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Flire Resistant Instrumentation & Control Cables www.caledonian-cables.co.uk

Mechanical and Thermal Properties Minimum Internal Bending Radius: 8×OD Temperature Range: -40℃ ~ +90℃

Dimensions and Weight Construction Nominal No. of Insulation cores×Cross Thickness section(mm²) mm

Nominal Minimum Maximum Nominal Inner Diameter Diameter Armour Sheath Over Inner Over Inner Wire Thickness Sheath Sheath Diameter mm mm mm mm Multipair 1.2 14.0 16.0 0.3 1.4 18.6 20.7 0.3 1.6 24.4 27.0 0.3 1.8 30.8 34.0 0.45 1.9 35.0 38.4 0.45 2.1 38.8 42.6 0.45 1.2 14.8 16.8 0.3 1.4 19.6 22.0 0.3

Nominal Outer Sheath Thickness mm

Minimum Overall Diameter mm

Maximum Overall Diameter mm

Approx. Weight kg/km

1.4 1.5 1.7 2.0 2.2 2.3 1.4 1.6

18.1 22.9 29.1 36.8 41.4 45.4 18.9 24.1

20.5 25.8 32.7 40.7 45.9 50.1 21.3 27.1

450 720 1080 1480 2140 2710 460 780

3×2×0.75 7×2×0.75 12×2×0.75 20×2×0.75 27×2×0.75 37×2×0.75 3×2×1 7×2×1

0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8

12×2×1

0.8

1.6

25.8

28.5

0.3

1.8

30.7

34.4

1170

20×2×1 27×2×1 37×2×1

0.8 0.8 0.8

1.8 2.0 2.2

32.6 37.3 41.3

0.45 0.45 0.45

2.1 2.2 2.4

38.8 43.7 48.1

43.2 48.3 53.3

1860 2330 2980

3×3×0.75 7×3×0.75 12×3×0.75 3×3×1 7×3×1 12×3×1

0.8 0.8 0.8 0.8 0.8 0.8

1.3 1.4 1.7 1.3 1.5 1.7

15.0 20.5 25.6 15.8 21.9 27.1

35.8 40.8 45.2 Multitriple 17.0 23.0 28.3 17.8 24.4 29.8

0.3 0.3 0.45 0.3 0.3 0.45

1.4 1.6 1.9 1.5 1.7 2.0

19.1 25.1 31.4 20.1 26.6 33.1

21.5 28.1 35.1 22.9 29.7 36.9

510 810 1370 550 910 1510

www.addison-cables.com

ADDISON

45


BS 6883&BS 7917 Caledonian Offshore & Marine Cables Technical Information www.caledonian-cables.co.uk

Cores Identification Insulation Colour Scheme MV cables Single core

Natural colour of the compound

Three core

Coloured tape or thread (e.g.: red - yellow - blue)

0.6/1 kV Power and Control Cables 1 core

According to BS 6883/BS 7917 Red or Black

Alternatives White and numbered

2 cores

Red - Black

White and numbered

3 cores

Red - Yellow - Blue

White and numbered

4 cores

Red - Yellow - Blue - Black

White and numbered

Above 4 cores

black numbers on white background

150/250 V Instrumentation Cables Pair

Black - White

Triple

Black - White - Red

Quad

Black - White - Red - Blue

Pairs/Triples/Quads are numbered with numbers printed directly on the insulated conductors (1-1; 2-2; ‌) or buy numbered tape

Outer Sheath Standard Colours MV power and control

Red

LV power and control

Black

Instrumentation and control

Grey

Other colours available on request

46

ADDISON

www.addison-cables.com


BS 6883&BS 7917 Caledonian Offshore & Marine Cables MV Flame Retardant Power & Control Cables www.caledonian-cables.co.uk

UNITED KINGDOM

HONG KONG

Marchants Industrial Centre, Mill Lane, Laughton, Lewes, East Sussex, BN8 6AJ, UK Tel: 44 (0) 207 419 5087 Fax: 44 (0) 207 831 9489 Email: sales@caledonian-cables.co.uk www.caledonian-cables.co.uk

Unit B 22/F CMA Building, 64-66 Connaught Road Central, Hong Kong Tel: 852 36527508 Fax: 852 35834834 Email: hk@caledonian-cables.co.uk www.caledonian-cables.co.uk

www.addison-cables.com

ADDISON

47


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.