Adj. Steel Column Products
T2JP
Type 2 Adjustable Support Columns
Type 2 Adjustable Support Columns are designed and tested to meet or exceed the CAN/CGSB-7.2-94 Adjustable Steel Columns standard. Materials: Top & Bottom Plates (4-1⁄2" x 6") – 3 gauge T2JPLD Tube (2-1⁄2" x 2-1⁄2") – 11 gauge T2JPMD Tube (3" x 3") – 10 gauge T2JPHD Tube (3" x 3") – 8 gauge Finish: T2JPLD & T2JPHD Tube – Powder-Coated Red Paint T2JPMD Tube – Powder-Coated Black Paint Plates – Grey Primer Paint
REDJACK
REDJACK 2.5 USP Stock No. T2JPLD84 T2JPLD88 T2JPLD90 T2JPLD96 T2JPLD102 T2JPLD108 T2JPLD114 T2JPLD120
Adjustable Height
Extended Length
Allowable Load1,3
Factored Resistance2,3
in
mm
in
mm
lb
kN
kg
lb
kN
kg
80 - 84 84 - 88 86 - 90 92 - 96 98 - 102 104 - 108 110 -114 116 - 120
2032 - 2134 2134 - 2235 2184 - 2286 2337 - 2438 2489 - 2591 2642 - 2743 2794 - 2896 2946 - 3048
84 88 90 96 102 108 114 120
2134 2235 2286 2438 2591 2743 2896 3048
16900 15500 15000 13600 12800 12200 11500 10900
75 69 67 60 57 54 51 48
7665 7030 6805 6170 5805 5535 5215 4945
26000 24300 23700 21800 20050 18400 17000 15600
116 108 105 97 89 82 76 70
11815 11020 10750 9935 9095 8385 7710 7120
BLACKJACK
9/16" hole for height adjustment
Adj. Steel Column Products
Installation: Turn threaded collar to extend the column to the desired height. Secure the top plate to wood beam with four (4) ¼” x 2” lag screws. • Ensure column is installed in a vertical and plumb position. • Column base shall be aligned and secured to a proper supporting slab. • Top plate shall cover the full width of the supported beam. Beam shall be centered on the top plate and continuous across the entire length of the plate.
Adjustment assembly
© 2015 MiTek. All rights reserved.
BLACKJACK 3.0 USP Stock No. T2JPMD84 T2JPMD88 T2JPMD90 T2JPMD96 T2JPMD102 T2JPMD108 T2JPMD114 T2JPMD120
Adjustable Height
Extended Length
Allowable Load1,3
Factored Resistance2,3
in
mm
in
mm
lb
kN
kg
lb
kN
kg
80 - 84 84 - 88 86 - 90 92 - 96 98 - 102 104 - 108 110 - 114 116 - 120
2032 - 2134 2134 - 2235 2184 - 2286 2337 - 2438 2489 - 2591 2642 - 2743 2794 - 2896 2946 - 3048
84 88 90 96 102 108 114 120
2134 2235 2286 2438 2591 2743 2896 3048
30400 27600 26400 24000 22900 22300 22000 21900
135 123 117 107 102 99 98 97
13790 12520 11975 10885 10385 10115 9980 9935
41500 39600 38600 36100 33650 31400 29900 27200
185 176 172 161 150 140 133 121
18825 17960 17510 16375 15265 14245 13560 12340
Square tube design
REDJACK 3.0 USP Stock No. T2JPHD84 T2JPHD88 T2JPHD90 T2JPHD96 T2JPHD102 T2JPHD108 T2JPHD114 T2JPHD120 T2JPHD144
Adjustable Height
Extended Length
Allowable Load1,3
Factored Resistance2,3
in
mm
in
mm
lb
kN
kg
lb
kN
kg
80 - 84 84 - 88 86 - 90 92 - 96 98 - 102 104 - 108 110 -114 116 - 120 140 - 144
2032 - 2134 2134 - 2235 2184 - 2286 2337 - 2438 2489 - 2591 2642 - 2743 2794 - 2896 2946 - 3048 3556 - 3658
84 88 90 96 102 108 114 120 144
2134 2235 2286 2438 2591 2743 2896 3048 3658
39600 36600 35500 32100 30000 28300 27500 26800 21300
176 163 158 143 133 126 122 119 95
17960 16600 16100 14560 13610 12835 12475 12155 9660
49900 47300 46400 43400 40300 37600 35100 32700 24800
222 210 206 193 179 168 156 145 111
22685 21455 21045 19730 18280 17105 15920 14840 11250
1) The Allowable Load values have been determined thru testing standards prescribed in the National Research Council Evaluation Directive for Adjustable Steel Columns using a safety factor of 2.25. 2) The Factored Resistance (ΦPn) values are established in accordance with the Canadian Standards Association S16, Design of Steel Structures, using a Resistance Factor Φ = 0.90. 3) The bearing resistance of the supported beam should be checked by the building designer using the appropriate CSA standard. New products or updated product information are designated in blue font.
Universal plate
HEAVY DUTY ADJUSTMENT ASSEMBLY FOR MAXIMUM LOADS MODULAR DESIGN FOR GREATEST JOB SITE FLEXIBILITY SQUARE POST FOR EASY AND ACCURATE CUT DOWN USE REBAR/ROD THROUGH 9/16" HOLE FOR HEIGHT ADJUSTMENT
43