Glulam Beam Connectors
LGU / MGU / HGU
Girder Hangers
Glulam Beam Connectors
Specialty Options Chart – refer to Specialty Options pages 220 and 222 for additional details Option
USP Series
Range
LGU MGU HGU LGU
Factored Resistance
MGU HGU LGU MGU HGU
Ordering
Skewed1
Inverted Flange
1˚ to 45˚
One Inverted-Flange option available on some sizes. See footnotes 2 and 3.
55% of table value. 30% of uplift. 65% of table value. 30% of uplift. 70% of table value. 30% of uplift.
100% of table value
Add SK , angle required, right (R) or left (L) , and square cut (SQ) or bevel cut (BV) to product number. Ex. LGU525_H=18_SK45R_SQ
Add 1IF and right (R) or left (L) to product number. Ex. LGU525_H=18_1IFR
1) Skewed hangers with skews greater than 15° may have all joist fasteners on outside flange. 2) One inverted-flange (1IF) is available on the following sizes: LGU363, LGU525 MGU525, MGU550, MGU563, MGU700 HGU525, HGU550, HGU562, HGU700, HGU725, HGU900 3) T he inverted flange option is not available on skewed LGU, MGU or HGU hangers. 4) Bevel cut required on skewed parts to meet table loads. 5) Skewed hangers typically require a bevel cut however, a square cut option may be available as a custom when requested. New products or updated product information are designated in blue font.
1) Skewed hangers with skews greater than 15° may have all joist fasteners on outside flange. 2) One inverted-flange (1IF) is available on the following sizes: LGU363, LGU525 MGU525, MGU550, MGU563, MGU700 HGU525, HGU550, HGU562, HGU700, HGU725, HGU900 3) The inverted flange option is not available on skewed LGU, MGU or HGU hangers. 4) Bevel cut rquired on skewed parts to meet table loads. 5) Skewed hangers typically require a bevel cut however, a square cut option may be available as a custom when requested. New products or updated product information are designated in blue font.
GHF
Glulam Face Mount Hangers
Materials: See chart Finish: USP primer Options: See Specialty Options Chart on page 159.
2-1/8"
Installation: • Use all specified fasteners. See Product Notes, page 15. • WS Wood Screws are supplied with GHF hangers.
H
D
W
Typical GHF51135 installation
Glulam Size 3-1/8 x 6 3-1/8 x 7-1/2 3-1/8 x 9 3-1/8 x 10-1/2 3-1/8 x 12 3-1/8 x 13-1/2 3-1/8 x 15 3-1/8 x 16-1/2 3-1/8 x 18 3-1/4 x 9 3-1/4 x 12
USP Stock No. GHF31600 GHF31750 GHF31900 GHF31105 GHF31120 GHF31135 GHF31150 GHF31165 GHF31178 GHF32900 GHF32120
Steel Ref. No. Gauge -12 -12 -12 -12 -12 -12 -12 -12 -12 -12 -12
W 3-3/16 3-3/16 3-3/16 3-3/16 3-3/16 3-3/16 3-3/16 3-3/16 3-3/16 3-5/16 3-5/16
H 5-7/8 7-3/8 8-7/8 10-3/8 11-7/8 13-3/8 14-7/8 16-3/8 17-3/4 8-7/8 11-7/8
Fastener Schedule2 Header Joist
D Qty Type Qty Type 2-3/8 10 WS25 4 WS25 2-3/8 12 WS25 4 WS25 2-3/8 16 WS25 5 WS25 2-3/8 20 WS25 6 WS25 2-3/8 22 WS25 6 WS25 2-3/4 24 WS25 6 WS25 2-3/4 26 WS25 7 WS25 2-3/4 28 WS25 9 WS25 2-3/4 30 WS25 11 WS25 2-3/8 16 WS25 5 WS25 2-3/8 22 WS25 6 WS25
DF Factored Resistance1 Lbs kN
S-P-F Factored Resistance1 Lbs kN
Floor
Uplift3
Floor
Uplift3
Floor
Uplift3
Floor
Uplift3
100% 3980 4770 6360 7950 8420 8420 9770 10565 11360 6360 8420
115% 2340 2340 2920 3505 3505 3505 4100 5270 6435 2920 3505
100% 17.70 21.22 28.29 35.36 37.45 37.45 43.46 47.00 50.53 28.29 37.45
115% 10.41 10.41 12.99 15.59 15.59 15.59 18.24 23.44 28.62 12.99 15.59
100% 3125 3745 4995 6240 6610 6610 7670 8295 8920 4995 6610
115% 1835 1835 2295 2755 2755 2755 3220 4135 5055 2295 2755
100% 13.90 16.66 22.22 27.76 29.40 29.40 34.12 36.90 39.68 22.22 29.40
115% 8.16 8.16 10.21 12.25 12.25 12.25 14.32 18.39 22.49 10.21 12.25
1) Factored resistances based on seat bearing calculated at 560 psi perpendicular to grain. 2) WS25 Wood Screws are 1/4" x 2-1/2" long and the WS3 Wood Screws are 1/4" x 3" long and are included with GHF hangers. 3) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code. New products or updated product information are designated in blue font. Dimensions (in)
158
Glulam Size 5-1/8 x 6 5-1/8 x 7-1/2 5-1/8 x 9
USP Stock No. GHF51600 GHF51750 GHF51900
Steel Ref. No. Gauge -12 -12 -12
W 5-3/16 5-3/16 5-3/16
H 5-7/8 7-3/8 8-7/8
Fastener Schedule2 Header Joist
D Qty Type Qty Type 2-3/8 10 WS3 4 WS3 2-3/8 14 WS3 4 WS3 2-3/8 18 WS3 5 WS3
DF Factored Resistance1 Lbs kN
S-P-F Factored Resistance1 Lbs kN
Floor
Uplift3
Floor
Uplift3
Floor
Uplift3
100% 3980 5570 7160
115% 2340 2340 2920
100% 17.70 24.78 31.85
115% 10.41 10.41 12.99
100% 3125 4370 5620
115% 100% 115% 1835 13.90 Continued on next8.16 page 1835 19.44 8.16 2295 25.00 10.21
Floor
Uplift3
© 2015 MiTek. All rights reserved.
Dimensions (in)
GHF