You can depend on most chlorine residual analyzers not to work.

TORRENS INDUSTRIES Tl 1003 GENERAL ALARM MONITOR AND PAGING SYSTEM

FIELD PROVEN The Tl 1003 is a field-proven alarm monitoring and alerting system which amongst other applications is particularly suited lor monitoring waste water pump stations. MICROPROCESSOR BASED The system is microprocessor based and wi ll report and log alarms from up to 64 pump stations with 8 inputs each. UHF RADIO PAGER Unattended alerting is via self-conlained UHF Radio Transmitter and pockel pagers which have a lypical ra nge of 30 ki lometres .

Or you can rely on one that does.

SYNTHESISED VOICE When an alarm occurs and the system is in lhe " remote" mode , lhe microprocessor " speaks " the synthesised station an d alarm inlormation via the pocket pager units and also by phone , whe n the operator acknowledges receipl ol the alarm.

Unfortunately, a typical analyzer spends most of its working life not working. No matter what any manufacturer might claim. But then , Capital Controls is not just any manufacturer. And our ADVANCE Series 870 is no ordinary analyzer. In fact, we consider it the most reliable in the industry. We believe you will, too. The 870 offers some rather unique features such as a positively driven electrode cleaning mechanism that eliminates signal drift and greatly reduces maintenance requirements . For normal service, the 870 needs only a weekly comparison check, no zero or calibration adjustments. With our analyzer, sample and reagents are gravity fed continuously, so metering pumps (often responsible for interrupted operation) are not required. -Better signal strength is achieved by the 870's gold and copper electrodes, which are many times bigger than others on the market. And a special thermistor ensures signal accuracy by automatically compensating for sample temperature variations. Whatever your specific needs, ~ Series 870 has versatility to match reliability. We offer two analyzer models that measure either free or total chlorine residual and monitor in seven ranges (from 0-0,5 mg/I to 0-20 mg/I) . They are available singly, with an indicator or chart recorder, or as part of any size ADVANCE chlorine residual, compound loop, or skid mounted gas feed system. Most companies who make analyzers also make excuses. We prefer to build analyzers that work.

FUTURE EXPANSION An important feature ol the system allows unskilled person nel 10 add future stations by pl ugging a circuit card into the base and adding a Transponder in the remot e station. The microprocessor is pre-programmed 10 accept up to 64 slations . No adjustments ate required . DATA GATHERING PAN EL Allows unskilled operators 10 expand system tram 1 to 64 pump stations by plug -in cards and addi ng remote Transponders . front panel LED 's display all alarm points . the system is lully Telecom approved (No. C79¡26¡41) .

,

MICROPROCESSOR MODULE Incorporates printer , date and time display, voice syn thesiser, phone acknowledge circ uit . audible alarm sounder and accept key . All station and alarm inlormation is printed together with date and time . PAGER MODULE Includes pager encoder and UHF radio transm itter. Fron t panel keyboard allows manual page tacility lor contacting personnel within a lypical 30 km radius.

Ill

Ill

CHARGER AND BATTERY MODULE Separate vented enclosure includes " no maintenance " ba tt ery wh ich ensures 24 hour continued operation in the event ot power lailure . No power is required in th e lield. as all Transponders receive their power from the base of Telecom lines .

Torrens Industries manufactures a full ra nge ol equipmenl including 7000 series V. F. Remote control and indicalions equipmenl. Tl t 000 Fire Reporting Systems and Tl 1010 Portable Evacuation Ala rm Units .

For more information on the Tl 1003 or other product lines, contact:

- . .-/'

Field Transponders

ADVANCE ... at your service.

~:!';2,~'~;;: w;,-m,,"

~

i;! ROM

II

ACROMET CAUST.J PTY. LTD.

26

l~l Torrens Industries E-;J

Telephone : (03) 544 7333 . Telex: AA 30918 N.S.W.: 19 G1bbes St., Chatswood , 2067 . Telephone : (02) 407 0201 Telex : AA 22586 ACR1 3

SEPTEMBER 1982

Orb House, 95 Wollongong Street, Fyshwick A.C.T. 2609. Telex: 62044 P.O. Box 41, Torrens, A.C.T. 2607, Au s tralia Telephone: (062) 80 6609, 80 6897

WATER


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.