Maintenance free terminals give an answer where accessibility is an issue. Tests, including long haul vibration, stun test, long haul association test, haul out, voltage drop; temperature rise and introduction to destructive climates approve the appropriateness of these terminals. Similarly reasonable are arrangements, for example, a 'joint made by a pressure instrument'.

Upkeep free terminals have the extra preferences of permitting the immediate addition of strong, stranded or adaptable conductors, and permitting the association of up to four conductors from 0.5mm2 to 4.0mm2.

Maintenance Free Connections


Junction boxes are regularly utilized amid alterations and augmentations to an establishment. With specific exemptions control 526.3 requires that each association might be accessible for assessment, testing and upkeep. The Electrical Safety Council Technical Manual expresses that "a junction box with screw terminals is a case of where associations must be accessible". The reason is to permit review of joints which could have casual or slackened after some time, a perceived issue with screwed terminals. Unless arrangement is made for access, where boarding, cover or other comparative covering is laid over a junction box with screw terminals, it may not be viewed as accessible and upkeep free terminals ought to be utilized. This is additionally fortified of the Wiring Regulations which states "Junction boxes with screw terminals must be accessible for assessment, testing and support or, alternatively, utilize upkeep free terminals/association"

Old Junction Boxes As we have talked about, unless utilizing an answer, for example, support free terminals, the access to electrical associations ought to be satisfactory for their protected and legitimate investigation, testing and upkeep. In this regard, associations ought to be in an area where they can sensibly be reached and where there is satisfactory working space.


Where associations are made in rooftop spaces and between floor spaces the fenced in areas containing the associations ought to ordinarily be settled and arrangement must be made for their access. Giving these two requirements are conformed to, at that point the proceeded with utilization of standard round electric boxes stays acceptable.