ARDEX Guide To Waterproofing Sheet Membranes

Page 8

ARDEX Torch Applied Membrane Installation Details CUT IN FLASHING

CONSTRUCTION JOINT ARDEX Torch Applied Membrane top layer fully bonded except over 250mm strip

Cap Layer Cut into Wall

Cap Layer Sheet Base Layer Sheet 250mm ARDEX Torch Applied Membrane strip stuck to one side of the joint only

Concrete Slab

EXPANSION JOINT LIQUID MEMBRANE FLASHING ARDEX WPM 330 or ARDEX WPM 310 Facade Coating

ARDEX Torch Applied Membrane top layer fully bonded except over 330mm underflashing

Foam Backing Rod

ARDEX WPM 320 with Deckweb reinforcement

Expansion Joint

Concrete Slab

330mm ARDEX Torch Applied Membrane underflashing fully bonded each side of joint

Bitumen Sheet Membrane System

Coving

ALTERNATE EXPANSION JOINT Capping

Sealant Bituminous Fibreboard

CAPPING DETAIL

Sand Cement Fillet Ballast Slipsheet Insulation Membrane

Metal Capping Membrane Sand Cement Fillet

Primer Screed

Concrete

Concrete

GARDEN BED/PLANTER BOX DETAIL Capping

ARDEX WPM 330 or ARDEX WPM 310 Facade Coating

ARDEX Protection Board ARDEX WPM 186 Garden Membrane

See Liquid Flashing Detail ARDEX ARDEX WPM 120 WPM 180

Coving

8

July 2007

Drainage Cell