ARDEX Guide To Waterproofing Sheet Membranes

Page 10

ARDEX Torch Applied Membrane Installation Details OUTSIDE CORNER

ONE WAY VENT INSTALLATION

Mineral Cap Sheet ST EP 2

Base Sheet

One Way Roof Vent

Fillet

EP

1

ST

ARDEX Torch Applied Membrane Base Sheet torched to Substrate

Substrate One Way Roof Vent Mineral Cap Sheet

Vented Base Sheet

Sealant

Vented Base Sheet

Screw Fixings

PIPE FLASHING

Flashing prior to installation

Aerators Parallel Cuts

Pipe

ARDEX Torch Applied Membrane flashing torched in place

Top ARDEX Torch Applied Membrane sheet cut to fit around pipe

Substrate

10

July 2007

Vapour Membranes Vent Sheet

Porous Concrete Decking Partial Bonding through Vapour Equalisation Layer