120118 gct test data summary flexure & shear proof

Page 1

Test Data Summary: Flexure & Shear

SBCRI Tested the Flexural Capacities of Panels • Followed techniques defined in ASTM E72 Specimen Name

Specimen Length (ft)

PSM80 PSM HP80 PSM160 PSM160-Roof PSG3-140 PSG3-240 PSG6-140

10 10 10 17 17 17 17

• Determined an allowable flexural strength

Flexural Strength Design Allowable Allowable Shear Panel Total Allowable Applied Load at a Self-Weight Load (PSF)5 4 1 (PSF) Load (PSF) Support (PLF) 2

1,400 2 1,400 2 1,400 2 1,400 3 2,337 3 4,208 3 3,783

30 50 35 60 60 90 75

80 180 140 35 215 405 370

110 225 175 95 275 495 445

L/360

Allowable Applied Load (PSF)4 65 155 135 35 125 395 225

L/240

Total Allowable Load (PSF)5 95 205 170 95 185 485 305

Allowable Applied Load (PSF)4 75 180 140 35 165 405 305

• Determined allowable loads at deflection limits

Flexural Serviceability Design

Total Allowable Load (PSF)5 105 225 175 95 230 495 380

L/180 Allowable Total Allowable Applied Load Load (PSF)5 4 (PSF) 80 110 180 225 140 175 35 95 210 270 405 495 370 445

L/120 Allowable Total Allowable Applied Load Load (PSF)5 4 (PSF) 80 110 180 225 140 175 215 275 405 495 370 445

1) The maximum allowed reaction 2) Value derived from shear testing a PSM80 panel 3) Value derived from flexural testing the given panel. Larger values possible via shear testing. Contact manufacturer for information. 4) Allowable Applied Load is the total load, not including the self-weight of the panel, that can be applied to the panel 5) Total Allowable Applied Load is the total load, including the self-weight of the panel, that can be applied to the panel

GCT Contact Information Victor Camacho, PE - Sales & Operations VP: 787-643-2684 or vcamacho@carmelo.com

Vist us on the web at gulfconcretechnology.com

www.sbcri.info


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.