Australasian Hydrographer March 2012

Page 7

Australasian Hydrographer, March 2012

+/-% Measurement Uncertainty of Calculated Average Velocity (for discharge)

If we fit a power curve to these points and extrapolate backwards for lesser numbers of verticals (such as used in sewer pipe gauging), then we get even higher measurement uncertainties for less than 5 verticals, as shown in Figure 2: • ±82.5% for 1 vertical only • ±41.7% for 2 verticals • ±28.0% for 3 verticals • ±21.1% for 4 verticals 50 45 40 35 30 25 20 AS3778 Based Estimate

15 10 5 0 0

5

10

15

20

25

30

35

40

45

50

Number of Verticals Used

+/-% Measurement Uncertainty of Calculated Average Velocity (for discharge)

Figure 1 Measurement uncertainty versus number of verticals (from AS3778 Part 3.1 table E.6)

50.0 45.0 40.0 35.0 30.0 25.0 Extrapolated Curve

20.0

AS3778 Based Estimate

15.0 10.0 5.0 0.0 0

5

10

15

20

25

30

35

40

Number of Verticals Used Figure 2 Fitted curve and extrapolated portion for less than 5 verticals