Education Lighting Brochure

Page 17

energy saving controls 100

Percentage Illumination Required

To illustrate the potential for energy saving using daylight linked dimming, we can model a typical 60m² classroom and consider the penetration of natural light as a percentage of the required illuminance across the space. If we assume 3 rows of lighting, each row comprising of 3 zones typically window row, centre row and inner row, we can assess the benefit from investing in dimming capability in each zone.

Inner Row

90

Centre Row

80 70

Window Row

60 50 40 30 20 10 0 J

F

M

A

M

J

J

A

S

O

N

D

Months

The graph opposite illustrates the amount of illumination required at each row of luminaires on a monthly basis. The table below details the energy use and savings that can be made by investing in this technology.

Installed load (KW)

running hours

annual energy use (KWh)

Annual energy saving (KWh)

No Controls

0.558

1800

1004

0

Detection

0.558

1200

670

334

Detection/Window Dimming

0.558

1200

486

518

Detection/All Dimming

0.558

1200

323

681

based on a classroom with 9, 4 X 14W (62 circuit watts recessed luminaires)