3174

Built-in contact check function for both withstanding voltage and insulation resistance  100VA capacity for withstanding voltage testing  Accurate test voltage generation by PWM method  Full remote operation  Store up to 8 settings in memory

STANDARD

Safety Standards Measuring Instruments

[Timer] Range and accuracy Delay/Ramp timer Interface Function

SPECIFICATIONS [Withstanding voltage test] 0.2 to 5.00kV AC, 100 VA Output voltage Digital setting, 0.01kV resolution Voltage setting method Sine wave (5% or less distortion with no load), 50/60Hz Waveform, Frequency selectable 0.01mA to 20.0mA, True RMS Measurement range True RMS, ±1.5%rdg. (1000V or higher), ±15V (1000V or lower) Voltage meter Window comparator method Judgment method [Insulation resistance test] 500, 1000V DC Testing voltage 1 to 1.2 times than the testing voltage No load voltage 1 to 1.2mA, Short circuit current: 4 to 5mA (500V) / 2 to 3mA (1000V) Rated testing current 0.5MΩ to 999MΩ (500V), 1MΩ to 999MΩ (1000V): ±4%rdg. Measurement range and 1000MΩ to 2000MΩ: ±8%rdg. accuracy Window comparator method Judgment method

DIGITAL MΩ HiTESTER

Monitor function Power supply Dimensions, mass Accessories

OPTIONS

REMOTE CONTROL BOX (single) 9613 REMOTE CONTROL BOX (dual) 9614 SAFETY TEST DATA MANAGEMENT SOFTWARE 9267 RS-232C CABLE 9637 (Dsub 9pin-9pin, cross,1.8m)

SPECIFICATIONS Measurement function Insulation resistance (Applied DC voltage method) 25, 50, 100, 250, 500, 1000 V DC Testing voltage Measurement range 25 to 50 V: 2MΩ to 200 MΩ, 3 ranges 100 to 250 V: 2MΩ to 2000 MΩ, 4 ranges 500 to 1000 V: 2MΩ to 4000 MΩ, 4 ranges ±2 % rdg. ±5 dgt. (at 25 to 100 V testing voltage, 0 to 20.00 MΩ) Accuracy (at 250 V testing voltage, 0 to 100.0 MΩ) (at 500 to 1000 V testing voltage, 0 to 999 MΩ) ±5 % rdg. (at 25 to 50V testing voltage, 19.0 to 200.0MΩ) (at 100V testing voltage, 19.0 to 2000MΩ) (at 250V testing voltage, 100.1 to 2000MΩ) (at 500 to 1000V testing voltage, 1000 to 4000MΩ) Fast: less than 0.7 second, Slow:less than 1.5 seconds (at manual ranging) Response times Fast: 10 samples/s, Slow:1 sample/s Sampling rates Comparator functions: judgments PASS or FAIL Test time timer Functions functions: 0.5 to 99 second Delay time timer functions: 0.1 to 99 second LED Display 100 to 240 V AC (50/60 Hz) Power supply Dimensions and mass 215W × 61H × 213D mm, 1.1 kg Power cord (1) Accessories

OPTIONS

39

RS-232C CABLE 9638 (Dsub 9pin-25pin,cross,1.8m) GP-IB CONNECTOR CABLE (2m) 9151-02

3154

For the laboratory to the production line, six test voltages from 25 to 1000V

STANDARD

0.3 to 999s (0.3 to 99.9s: ±50ms, 100 to 999s: ±0.5s) 0.1 to 99.9s (±50ms) EXT I/O, EXT SW, RS-232C 8 settings memory, Hold, Beeper, Contact check (withstanding voltage, insulation resistance) Output voltage, Measured current, Insulation resistance 100 to 240V AC (50/60Hz), 200VA max. 320W × 155H × 395D mm, 15kg High Voltage Test Lead 9615 (1 each for HV and Return), Power cord (1)

TEST PROBE L9787 SWITCHED PROBE 9299 RS-232C CABLE (1.8 m) (9pin-9pin/Cross) 9637 RS-232C CABLE (1.8 m) (9pin-25pin/Cross) 9638 SAFETY TEST DATA MANAGEMENT SOFTWARE 9267 OUTPUT CORD 9094