Toyota 7fbcu55 forklift service repair manual

Page 51

2-16

TRAVELING CONTROLLER ASSY REMOVAL-INSTALLATION (35

- 55 MODEL)

Caution: Before starting the job, measure the voltage between P4 and N1; if there is any voltage, insert a resistor at approx. 100 Q between P4 and N1 to discharge the capacitor. T = N-m (kgf-cm) [ft-lbfl

Nut connecting controller to cable

M8 M10

- 15 (112 - 153) [8.1 - 11.11 T = 15 - 19 (153 - 194) [11.1 - 14.01

T = 11

Removal Procedure 1 Disconnect the battery plug. 2 Remove the side cover RH. 3 Remove the duct. 4 Disconnect the connectors and terminals from the traveling controller ASSY. 5 Remove the controller ASSY.

Installation Procedure The installation procedure is the reverse of the removal procedure.


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.