Point Operation Press MSch: ON

[Point I] Inspection: Magnet switch contact continuity inspection Tester range Measurement terminals Standard

T-W, S-V, R-U

MSch ON MSch OFF

Inspection: Magnet switch contact continuity inspection Tester range Measurement terminals CLK20JT (Togami) Standard FW-1S (Fuji) CLK50JT (Togami)

R XI A1-A2

700 R 400 R 350 R

Inspection: Thermal relay contact continuity inspection Tester range Measurement terminals Standard

@

(Fuji Electric)

Test switch

Reset switch (Togami Electric)

Operated

Not operated Operated

Inspection: Inspect if the thermal relay is deactivated upon pressing the reset switch when the thermal relay is activated. Do not adjust the thermal relay operating current. If charging stops due to thermal relay activation while the charger is in use, always check the thermal relay activating cause and perform resetting after taking the corrective action. Pres the reset switch lightly to reset the thermal relay. * Test the thermal relay as follows: Togami: Press the reset switch. Use a thin screwdriver and move the reset Fuji: switch to the left.

+!*!Not operated