Maintenance and inspection schedule
Service Manual
A 934 C-HD Litronic, 31793 - log loader Maintenance/inspection at operating hours
WORK TO BE CARRIED OUT A 934 C-HD Litronic, type 1053 by maintenance personnel (machine operator) Initial and single interval Repeat interval Annually, at the start of the cold season when required
with authorised specialist technician Initial and single interval Repeat interval
Belt drive: Check belt; replace, if necessary / V-ribbed belt: check tension; adjust, if necessary Check intake and exhaust systems for general condition, fixture and leakage Grease the flywheel ring gear Replace filter insert at the crankcase ventilation Check oil pan, engine bearings and diesel engine support for proper fixture Check / readjust valve play Check heating flange 3000
Check vibration dampers for deformation RADIATOR Checking the coolant level Check cooling and heating systems for general condition and leakage Check corrosion inhibitor and antifreeze agent concentration in coolant
3000
Change coolant (at least every 2 years) FUEL SYSTEM Check water separator at the fuel pre-filter and drain off water, if necessary Drain water and deposit from fuel tank
4)
Check fuel system for leakage and general state
4)
Change fuel pre-filter
4)
Change fuel fine filter Bleed fuel system AIR FILTER Check underpressure indicator of the air filter Clean dust removal valve of the air filter Change main element of the dry air filter (according to maintenance indication / annually)
3.21.2 copyright by
MJFCIFSS