Jcb 536 60 telescopic handler service repair manual sn:1522577 to tba

Page 123

Section 2-2 - Care and Safety General Procedures Battery Disconnection/Connection

Battery Disconnection/Connection

!MWARNING Keep metal watch straps and any metal fasteners on your clothes, clear of the positive (+) battery terminal. Such items can short between the terminal and nearby metal work. If it happens you can get burned. 5-2-2-4

Disconnection 1

Get access to Topics ( T 2-2-2)

the

battery.

See

K Related

2

Remove the leads. Disconnect the earth (-) terminal first.

Connection 1

Check the battery. a

If the terminal is dirty, clean the post.

Fig 7.

797650

b If the terminal post is corroded and generates white powder wash the terminal with hot water. If considerable corrosion is detected, clean with a wire brush or abrasive paper. c

After cleaning, apply a thin coat of petroleum jelly to the terminal.

2

Re-connect the leads. Connect the earth (-) terminal last.

3

Close and lock the access panels.

2-2-13

9813/0900-2 (2-02-05)