Case ih maxxum 125 multicontroller tractor service repair manual

Page 118

HYDRAULIC, PNEUMATIC, ELECTRICAL, ELECTRONIC SYSTEMS - PRIMARY HYDRAULIC POWER SYSTEM

7.

8.

Set the remote control valve number 1 in the `Extend' position. Set the engine speed to 1500 rev/min to observe the system operation pressure or 2200 rev/min for the maximum system pressure. The pressure reading should be 205 - 215 bar (2973 - 3118 psi) and is the `Maximum Pressure`.

BVE0159C

6

BVE0154B

7

BSE2607A

8

If the pressure reading is not to specification adjust the pressure compensating valve (2).

Charge Pressure 9.

Remove the charge pressure switch and install the adaptor 380000572 (1) and the quick release fitting 380000492 (2). - Test port thread M10 x 1.0 Attach a 0 - 10 bar (0 - 145 psi) pressure gauge 380000551, using the quick release coupler 380000543 and the hose 380000545.

MAXXUM-T3-DRAFT 02/11/2011

A.10.A / 100