Push sealer and housing into cylinder housing, carefully tighten nut. If necessary, use the counter part of the connector as a retainer.
To retain all parts, loosen nut by 1/4 turn and retighten properly, secure with adhesive.
On electronic wiring harness, insert heat seal (Ray-blocker) on end of insulation and adhere during the following shrinking procedure.
Pull shrink fit sleeve over housing and evenly heat with hot air blower until all parts are tightly covered.
Caution:
Do not pull the wires during the shrink fit procedure. Do not apply heat above 125° C (257° F).
4. Installation Guidelines KPSE plug Connector
4.1. Design A = Socket B = plug Item listing 1 Insulator 1.1 Contact retainer (integrated in insulator) 2 Barrel 2.1 Seal ring 3 Cone ring 4 Housing 5 Bayonet coupling nut 6 Socket type contact with crimped wire 7 Pin type contact with crimped wire Tightening torque for end bell: Size:
KPSE
06
E
22-
21PB – DN Other specifications Size Classification Type of housing Model
8, 10
max. 4 Nm
12,14,16
max. 6 Nm
18, 20, 22, 24
max. 10 Nm