Service manual
Product description Technical data
Pre-glow system Valid for:
L506 - 1108 / from 22400; L507 - 1109 / from 22400; L508 - 1111 / from 22400; L509 - 1112 / from 22400; L510 - 1114 / from 22400; L507 - 1110 / from 22400; L509 - 1113 / from 22400;
Description
Value Unit
Power consumption per plug
20
8
Amp
L514 intake air pre-heater Valid for:
L514 - 1115 / from 21019
Description
Value Unit
Heating flange current consumption
120
20
Amp
Vacuum switch Description Air filter contamination vacuum switch activation point
Value Unit 50 mbar
Coupling torsion damper Valid for:
L506 - 1108 / from 22400; L507 - 1109 / from 22400; L507 - 1110 / from 22400; L508 - 1111 / from 22400;
Description
Value Unit CF-KE-093-6.5- 65603
Type Tightening torque for elastic element fixing screws (6 x) Valid for:
23 Nm
L509 - 1112 / from 22400; L509 - 1113 / from 22400; L510 - 1114 / from 22400;
Description
Value Unit CF-KE-093- 6.5- 65921
Type Tightening torque for elastic element fixing screws (6 x) Valid for:
23 Nm
L514 - 1115 / from 22400;
Description
Value Unit
Type
BOWEX 65 - 10" -
Tightening torque for elastic element fixing screws (8 x) Tightening torque for coupling star fixing screws (2 x)
L506 - 1108 / from 22400 L507 - 1109 / from 22400 L508 - 1111 / from 22400 L509 - 1112 / from 22400
L510 - 1114 / from 22400 L507 - 1110 / from 22400 L509 - 1113 / from 22400 L514 - 1115 / from 21019
40 Nm 45+5 Nm
2.1-17 of 17 copyright of
MJFCIFSS