Section 3
Routine Maintenance
Section 3
Service Schedules
2-5
2-5
Revised Service Schedules Rockbreaker or Crusher Usage Note: The following servicing intervals should be adopted instead of those called for in the main Service Schedules, when a rockbreaker or crusher is used regularly. Servicing Intervals (hours) Servicing Operation 100% usage
40% usage
20% usage
10% usage
10 600
10 1500
10 3000
10 4000
Return Filter Element - change+
100
300
600
800
Suction Strainer
- clean - change
100 600
300 1500
600 3000
800 4000
Servo Oil Filter
- change
100
300
600
800
Drain Filter
- change
100
300
600
800
Nephron Filter
- change
100
300
600
800
Breaker In-line Filter
- change
100
300
600
800
Hydraulic Oil
- sampling
200
300
600
800
100
300
600
800
Hydraulic Oil
*
Steering Filter +
- check level - change
It is recommended that oil samples are taken and analysed immediately prior to each Return Filter Element change.
9803/6310
Issue 2*