Door Assemblies 2. Disconnect heater switch connector from heater switch plate. 3. Remove four screws from heater valve and switch plate and remove plate.

0100 YRM 1290 5. Disconnect supply hose at heater valve and disconnect return hose from heater coil. See Figure 43 for lift truck models •

4. Disconnect AC rocker switch. See Figure 43 for lift truck models •

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (G813, H813)

See Figure 44 for lift truck models •

See Figure 44 for lift truck models •

1. 2. 3. 4. 5. 6.

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (G813, H813)

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (J813)

GLP/GDP40VX5/VX6; GLP/GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (J813)

SCREW AC ROCKER SWITCH HEATER VALVE LOCKNUT SWITCH PLATE AC/ HEATER UNIT

7. 8. 9. 10. 11. 12.

AC HOSES HEATER SUPPLY HOSE HEATER RETURN HOSE HEATER COIL AC EXPANSION VALVE MOUNTING BRACKET

Figure 44. Air Conditioner/Heater Unit Assembly Removal, Lift Truck Models GLP/GDP40VX5/VX6; GLP/ GDP45SVX5, GLP/GDP45VX6; GLP/GDP50-55VX (GP/GLP/GDP080, 090, 100, 110, 120VX) (J813)