Toyota 7fbe18 forklift service repair manual

Page 62

2-24 3. The magnetic switch is not suctioned when the charging button is pressed. NG

Display screen check

(No display) OK (Charging screen display) NG

Inspection 1 Magnetic switch voltage check

See "2.The charging screen does not appear though the AC power plug is connected." on page 2-23.

Inspection 2 Charging button check

OK

OK

Magnetic switch (MSch) defect

Display defect

NG

Switch box defect

INSPECTION 1. Magnetic switch voltage inspection (See page 2-20.) INSPECTION 2. Charging button inspection (See page 2-21.) 4. Charging completes normally but the charge is insufficient.

Battery and transformer capacity compatibility check (See page 2-2.)

NG

Capacity incompatibility

OK

Tap voltage check (See page 2-6.)

NG

Tap adjustment defect

OK

NG

Individual transformer check (See page 2-12.)

ANL : I/O MONITOR1 I/O1-8 NG Battery voltage check (other than OK) (comparison between displayed value and actually measured value)

Transformer defect

CPU board defect

± %

OK within 2 from the actually measured value Battery electrolyte specific garvity and temperature check after completion of charging

NG

Battery defect (Check if corrected by equal charging)

OK

×Decreased capacity due to lowering of electrolyte temperature ×Decreased capacity due to battery service life 5. Charging progress indicator does not proceed during the timer test. Display defect


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.