Toyota 7fbe18 forklift service repair manual

Page 73

2-35

SERVICE STANDARDS Item Power supply voltage

Service Standard V

No-load secondary voltage (The values are the same for 200 V and 400 V.)

AC V

No-load secondary voltage

DC V

MSch coil resistance

For 200 V

200 to 230 V

For 400 V

340 to 460 V

SG3-69-45JBY-2

Approx. 56

SG3-69-60JBY-2

Approx. 55

SG3-69-80JBY-2

Approx. 57

SG3-69-100JBY-2

Approx. 58

SG3-69-130JBY-2

Approx. 56

SG3-100-100JBY-2

Approx. 85

24 V

Approx. 37

36 V

Approx. 56

48 V

74 to 78

72 V

Approx. 114

CLK-11HT·15HT

Approx. 970

CLK-20HT·25HT

Approx. 490

CLK-35HT

Approx. 300

CLK-50HT

Approx. 250

Dch resistance in forward

Approx. 25

Dch resistance in reverse

Dch tightening torque

20M10·20MA10

2.35 (24) [1.74]

20M20·20MA20

2.35 (24) [1.74]

20M30·20MA30

2.35 (24) [1.74]

N·m (kgf·cm) [ft-lb] 45M10·45MA10

16.7 (170) [12.3]

45M20·45MA20

16.7(170) [12.3]

45M30·45MA30

16.7 (170) [12.3]

70M10·70MA10

22.0 (224) [16.2]

Insulation resistance(500 V Megger)

MΩ

0.2 or more