Mitsubishi fgc15n forklift trucks chassis, mast and options service repair manual sn:af81f 10121 up

Page 33

ELECTRIC SYSTEM

(emergency energization)

3 Âą 2 mm

Refer to the brake system.

Indicator or ON activating position

2.2.5 Brake fluid sensor

213465

2.2.6 Stop lamp switch Connect a tester across the terminals and check that the lamps turn ON and OFF when the push rod extended projection is to the specified value. Measure the insulation resistance value across the terminals when the push rod is pushed in. Replace the switch if the measured insulation resistance value is less than the value listed below. Insulation resistance value

1 M ohm or more (with megger tester at 500V)

Push rod

4 mm

M10Ă—1.25

2mm

OFF ON

213466

Rated voltage DC12V

3-8